Repositorio Digital de la UPF
Publication Artículo científico (JournalArticle)

Long-term effectiveness of irreversible electroporation in a murine model of colorectal liver metastasis

  • Ivorra Cano, Antoni, 1974-
  • Sánchez Velázquez, Patricia, 1985-
  • Castellví Fernández, Quim
  • Villanueva, Alberto
  • Iglesias Coma, Mar
  • Quesada Diez, Rita
  • Pañella Vilamú, Clara, 1987-
  • Cáceres Aguilar, Mario
  • Dorcaratto, Dimitri
  • Andaluz, Anna
  • Moll, Xavier
  • Burdío, José M.
  • Grande Posa, Luís
  • Burdío Pinilla, Fernando
Irreversible electroporation (IRE) has recently gained in popularity as an ablative technique, however little is known about its oncological long-term outcomes. To determine the long-time survival of animals treated with a high dose of IRE and which histological changes it induces in tumoral tissue, IRE ablation was performed in forty-six athymic-nude mice with KM12C tumors implanted in the liver by applying electric current with different voltages (2000 V/cm, 1000 V/cm). The tumors were allowed to continue to grow until the animals reached the end-point criteria. Histology was harvested and the extent of tumor necrosis was semi-quantitatively assessed. IRE treatment with the 2000 V/cm protocol significantly prolonged median mouse survival from 74.3 ± 6.9 days in the sham group to 112.5 ± 15.2 days in the 2000 V/cm group. No differences were observed between the mean survival of the 1000 V/cm and the sham group (83.2 ± 16.4 days, p = 0.62). Histology revealed 63.05% ± 23.12 of tumor necrosis in animals of the 2000 V/cm group as compared to 17.50% ± 2.50 in the 1000 V/cm group and 25.6% ± 22.1 in the Sham group (p = 0.001). IRE prolonged the survival of animals treated with the highest electric field (2000 V/cm). The animals in this group showed significantly higher rate of tumoral necrosis., This research was supported by the spanish government under grants TEC2011-27133-c02 and TEC2010-17285, and by the spanish “plan estatal de investigación, desarrollo e innovación orientada a los retos de la sociedad” under grant TEC2014–52383-c3-r (TEC2014–52383-c3-2-r and TEC2014–52383-c3-3-r).
Repositorio Digital de la UPF
Publication Artículo científico (JournalArticle)

Dynamics of cell death after conventional IRE and H-FIRE treatments

  • Mercadal, Borja
  • Beitel White, Natalie
  • Aycock, Kenneth N.
  • Castellví Fernández, Quim
  • Davalos, Rafael Vidal
  • Ivorra Cano, Antoni, 1974-
High-frequency irreversible electroporation (H-FIRE) has emerged as an alternative to conventional irreversible electroporation (IRE) to overcome the issues associated with neuromuscular electrical stimulation that appear in IRE treatments. In H-FIRE, the monopolar pulses typically used in IRE are replaced with bursts of short bipolar pulses. Currently, very little is known regarding how the use of a different waveform affects the cell death dynamics and mechanisms. In this study, human pancreatic adenocarcinoma cells were treated with a typical IRE protocol and various H-FIRE schemes with the same energized time. Cell viability, membrane integrity and Caspase 3/7 activity were assessed at different times after the treatment. In both treatments, we identified two different death dynamics (immediate and delayed) and we quantified the electric field ranges that lead to each of them. While in the typical IRE protocol, the electric field range leading to a delayed cell death is very narrow, this range is wider in H-FIRE and can be increased by reducing the pulse length. Membrane integrity in cells suffering a delayed cell death shows a similar time evolution in all treatments, however, Caspase 3/7 expression was only observed in cells treated with H-FIRE., This work was supported by the Ministry of Economy and Competitiveness of Spain (Grant No. TEC2014-52383-C3-2-R), the Pancreatic Cancer Action Network (Grant No. 16-65-IANN) and Cures Within Reach (Grant No. PUJFSANY). Antoni Ivorra gratefully acknowledges financial support by ICREA under the ICREA Academia programme.
Repositorio Digital de la UPF
Publication Artículo científico (JournalArticle)

Modeling methods for treatment planning in overlapping electroporation treatments

  • Perera Bel, Enric
  • Mercandal, Borja
  • Garcia-Sanchez, Tomas
  • González Ballester, Miguel Ángel, 1973-
  • Ivorra Cano, Antoni, 1974-
Objective: Irreversible electroporation (IRE) is a non thermal tissue ablation therapy which is induced by applying high voltage waveforms across electrode pairs. When multiple electrode pairs are sequentially used, the treatment volume (TV) is typically computed as the geometric union of the TVs of individual pairs. However, this method neglects that some regions are exposed to overlapping treatments. Recently, a model describing cell survival probability was introduced which effectively predicted TV with overlapping fields in vivo. However, treatment overlap has yet to be quantified. This study characterizes TV overlap in a controlled in vitro setup with the two existing methods which are compared to an adapted logistic model proposed here. Methods: CHO cells were immobilized in agarose gel. Initially, we characterized the electric field threshold and the cell survival probability for overlapping treatments. Subsequently, we created a 2D setup where we compared and validated the accuracy of the different methods in predicting the TV. Results: Overlap can reduce the electric field threshold required to induce cell death, particularly for treatments with low pulse number. However, it does not have a major impact on TV in the models assayed here, and all the studied methods predict TV with similar accuracy. Conclusion: Treatment overlap has a minor influence in the TV for typical protocols found in IRE therapies. Significance: This study provides evidence that the modeling method used in most pre-clinical and clinical studies seems adequate.
Repositorio Digital de la UPF
Publication Artículo científico (JournalArticle)

Avoiding nerve stimulation in irreversible electroporation: a numerical modeling study

  • Mercadal, Borja
  • Arena, Christopher B.
  • Davalos, Rafael Vidal
  • Ivorra Cano, Antoni, 1974-
Electroporation based treatments consist in applying one or multiple high voltage pulses to the tissues to be treated. As an undesired side effect, these pulses cause electrical stimulation of excitable tissues such as nerves and muscles. This increases the complexity of the treatments and may pose a risk to the patient. To minimize electrical stimulation during electroporation based treatments, it has been proposed to replace the commonly used monopolar pulses by bursts of short bipolar pulses. In the present study, we have numerically analyzed the rationale for such approach. We have compared different pulsing protocols in terms of their electroporation efficacy and their capability to trigger action potentials in nerves. For that, we have developed a modeling framework that combines numerical models of nerve fibers and experimental data on irreversible electroporation. Our results indicate that, by replacing the conventional relatively long monopolar pulses by bursts of short bipolar pulses, it is possible to ablate a large tissue region without triggering action potentials in a nearby nerve. Our models indicate that this is possible because, as the pulse length of these bipolar pulses is reduced, the stimulation thresholds raise faster than the irreversible electroporation thresholds. We propose that this different dependence on the pulse length is due to the fact that transmembrane charging for nerve fibers is much slower than that of cells treated by electroporation because of their geometrical differences., This work was supported by the Ministry of Economy and Competitiveness of Spain through the grant TEC2014-52383-C3-2-R. RVD’s research is supported by the National Institutes of Health under award number NIH 1R21 CA192041-01.
Repositorio Digital de la UPF
Publication Contribución de congreso (ConferenceOutput)

Modeling liver electrical conductivity during hypertonic injection

  • Castellví Fernández, Quim
  • Sánchez Velázquez, Patricia, 1985-
  • Moll, Xavier
  • Berjano, Enrique J.
  • Andaluz, Anna
  • Burdío Pinilla, Fernando
  • Bijnens, Bart
  • Ivorra Cano, Antoni, 1974-
Metastases in the liver frequently grow as scattered tumor nodules which neither can be removed by surgical resection nor focally ablated. Previously, we have proposed a novel technique based on irreversible electroporation which may be able to simultaneously treat all nodules in the liver while sparing healthy tissue. The proposed technique requires increasing the electrical conductivity of healthy liver by injecting a hypersaline solution through the portal vein. Aiming to assess the capability of increasing the global conductivity of the liver by means of hypersaline fluids, here it is presented a mathematical model which estimates the NaCl distribution within the liver and the resulting conductivity change. The model fuses wellestablished compartmental pharmacokinetic models of the organ with saline injection models employed for resuscitation treatments and it considers changes in sinusoidal blood viscosity due to the hypertonicity of the solution. Here it is also described a pilot experimental study in pigs in which different volumes of NaCl 20% (from 100 to 200 ml) were injected through the portal vein at different flow rates (from 53 to 171 ml/min). The in vivo conductivity results fit those obtained by the model, both quantitatively and qualitatively, being able to predict the maximum conductivity with a 14.6% average relative error. The maximum conductivity value was 0.44 S/m which corresponds to increasing four times the mean basal conductivity (0.11 S/m). The results suggest that the presented model is well suited for predicting on liver conductivity changes during hypertonic saline injection., Spanish Government; contract/grant number: TEC2014-52383-C3-1-R, TEC2014-52383-C3-2-R and TEC2014-52383-C3-3-R
Repositorio Digital de la UPF
Publication Contribución de congreso (ConferenceOutput)

Charge counter for performing active charge-balance in miniaturized electrical stimulators

  • Becerra Fajardo, Laura
  • Ivorra Cano, Antoni, 1974-
Functional Electrical Stimulation (FES) has been explored in order to restore the capabilities of the nervous system in patients that suffer from paralysis. This area of research and of clinical practice greatly benefits from any technological improvement yielding miniaturization. In this regard, we recently proposed and demonstrated an innovative electrical stimulation method based on implanted microstimulators that operate as rectifiers of bursts of innocu-ous high frequency current supplied by skin electrodes, gener-ating low frequency currents that are capable of stimulating excitable tissues. We envision flexible ultrathin implants (di-ameters < 300 μm) containing ASICs that have advanced ca-pabilities, such as addressability and current control. As min-iaturization is the main aim of this method, the use of bulky DC-blocking capacitors (e.g. 10 μF) to accomplish zero net charge injection and avoid electrochemical tissue and electrode damage is highly inconvenient. As an alternative, here we present an active charge-balance method based on the use of a digital charge quantifier, whose operation is inspired in the functioning of the tipping bucket rain gauge. The system moni-tors the charge injection, matching the charge injected in the cathodal phase, with the charge injected in the anodal phase, generating a biphasic current waveform that adapts itself to possible current source mismatches. We have implemented a prototype built with discrete components which uses a capaci-tor of only 100 pF for the charge counter., AI’s research is supported by a Ramón y Cajal fellowship/nfrom the Spanish government and a Marie Curie grant/n(IRG 256376) from the European Commission. LBF’s research/nis supported by a scholarship from the UPF.
Repositorio Digital de la UPF
Publication Artículo científico (JournalArticle)

Electrical modeling of the influence of medium conductivity on electroporation

  • Ivorra Cano, Antoni, 1974-
  • Villemejane, Julien
  • Mir, Lluis M.
Electroporation is the phenomenon in which cell membrane permeability is increased by exposing the cell to short high electric field pulses. Experimental data show that the amount of permeabilization depends on the conductivity of the extracellular medium. If medium conductivity decreases then it is necessary to deliver a pulse of larger field amplitude in order to achieve the same effect. Models that do not take into account the permeabilization effect on the membrane conductivity cannot reproduce qualitatively the experimental observations. Here we employ an exponential function for describing the strong dependence of membrane conductivity on transmembrane potential. Combining that model with numerical methods we demonstrate that the dependence on medium conductivity can be explained as being the result of increased membrane conductance due to electroporation. As experimentally observed, extracellular conductivities of about 1 and 0.1 S m−1 yield very similar results, however, for lower conductivities (<0.01 S m−1) the model predicts that significantly higher field magnitudes will be required to achieve the same amount of permeabilization., This work was supported by grants from: CNRS, Institute of cancerology Gustave-Roussy, University Paris Sud, INCa (National Institute of Cancer, France—contract number 07/3D1616/Doc-54-3NG-NC) and French National Agency (ANR) through Nanoscience and Nanotechnology program (Nanopulsebiochip no. ANR-08-NANO-024). AI’s research is currently supported by a Ramon y Cajal/nfellowship from the Spanish Ministry for Science and Innovation.
Repositorio Digital de la UPF
Publication Artículo científico (JournalArticle)

EView: an electric field visualization web platform for electroporation-based therapies

  • Perera Bel, Enric
  • Yagüe, Carlos
  • Mercadal, Borja
  • Ceresa, Mario
  • Beitel White, Natalie
  • Davalos, Rafael Vidal
  • González Ballester, Miguel Ángel, 1973-
  • Ivorra Cano, Antoni, 1974-
Background and objectives: Electroporation is the phenomenon by which cell membrane permeability to ions and macromolecules is increased when the cell is briefly exposed to high electric fields. In electroporation-based treatments, such exposure is typically performed by delivering high voltage pulses across needle electrodes in tissue. For a given tissue and pulsing protocol, an electric field magnitude threshold exists that must be overreached for treatment efficacy. However, it is hard to preoperatively infer the treatment volume because the electric field distribution intricately depends on the electrodes’ positioning and length, the applied voltage, and the electric conductivity of the treated tissues. For illustrating such dependencies, we have created EView (https://eview.upf.edu), a web platform that estimates the electric field distribution for arbitrary needle electrode locations and orientations and overlays it on 3D medical images. Methods: A client-server approach has been implemented to let the user set the electrode configuration easily on the web browser, whereas the simulation is computed on a dedicated server. By means of the finite element method, the electric field is solved in a 3D volume. For the sake of simplicity, only a homogeneous tissue is modeled, assuming the same properties for healthy and pathologic tissues. The non-linear dependence of tissue conductivity on the electric field due to the electroporation effect is modeled. The implemented model has been validated against a state of the art finite element solver, and the server has undergone a heavy load test to ensure reliability and to report execution times. Results: The electric field is rapidly computed for any electrode and tissue configuration, and alternative setups can be easily compared. The platform provides the same results as the state of the art finite element solver (Dice = 98.3 ± 0.4%). During the high load test, the server remained responsive. Simulations are computed in less than 2 min for simple cases consisting of two electrodes and take up to 40 min for complex scenarios consisting of 6 electrodes. Conclusions: With this free platform we provide expert and non-expert electroporation users a way to rapidly model the electric field distribution for arbitrary electrode configurations., This work was supported by the Ministry of Economy and Competitiveness of Spain (grant number TEC2014-52383-C3-2-R), the María de Maeztu Units of Excellence Programme (grant number MDM-2015-0502) and by the Spanish Ministry of Economy and Competitiveness under the Programme for the Formation of Doctors (grant number BES-2017-081164). Antoni Ivorra gratefully acknowledges the financial support by ICREA under the ICREA Academia programme.
Repositorio Digital de la UPF
Publication Artículo científico (JournalArticle)

Dependence of electroporation detection threshold on cell radius: an explanation to observations non compatible with Schwan’s equation model

  • Mercadal, Borja
  • Vernier, P. Thomas
  • Ivorra Cano, Antoni, 1974-
It is widely accepted that electroporation occurs when the cell transmembrane voltage induced by an external applied electric field reaches a threshold. Under this assumption, in order to trigger electroporation in a spherical cell, Schwan’s equation leads to an inversely proportional relationship between the cell radius and the minimum magnitude of the applied electric field. And, indeed, several publications report experimental evidences of an inverse relationship between the cell size and the field required to achieve electroporation. However, this dependence is not always observed or is not as steep as predicted by Schwan’s equation. The present numerical study attempts to explain these observations that do not fit Schwan’s equation on the basis of the interplay between cell membrane conductivity, permeability, and transmembrane voltage. For that, a single cell in suspension was modeled and the electric field necessary to achieve electroporation with a single pulse was determined according to two effectiveness criteria: a specific permeabilization level, understood as the relative area occupied by the pores during the pulse, and a final intracellular concentration of a molecule due to uptake by diffusion after the pulse, during membrane resealing. The results indicate that plausible model parameters can lead to divergent dependencies of the electric field threshold on the cell radius. These divergent dependencies were obtained through both criteria and using two different permeabilization models. This suggests that the interplay between cell membrane conductivity, permeability, and transmembrane voltage might be the cause of results which are noncompatible with the Schwan’s equation model., This work was supported by the Ministry of Economy and Competitiveness of Spain through Grant TEC2014-52383-C3-2-R. PTV received support from the Old Dominion University Frank Reidy Research Center for Bioelectrics and the Air Force Office of Scientific Research (FA9550-15-1-0517, FA9550-14-1-0123).
Repositorio Digital de la UPF
Publication Artículo científico (JournalArticle)

Avoiding neuromuscular stimulation in liver irreversible electroporation using radiofrequency electric fields

  • Castellví Fernández, Quim
  • Mercadal, Borja
  • Moll, Xavier
  • Fondevila, Dolors
  • Andaluz, Anna
  • Ivorra Cano, Antoni, 1974-
Electroporation based treatments typically consist in applying high voltage dc pulses. As an undesired side effect, these dc pulses cause electrical stimulation of excitable tissues such as motor nerves. In the present in vivo study, it was explored the use of bursts of sinusoidal voltage in the frequency range from 50 kHz to 2 MHz to induce irreversible electroporation (IRE) whilst avoiding neuromuscular stimulation. Series of 100 dc pulses or sinusoidal bursts, both with an individual duration of 100 μs, were delivered to rabbit liver through thin needles in a monopolar electrode configuration and thoracic movements were recorded with an accelerometer. Tissue samples were harvested three hours after treatment and later postprocessed to determine the dimensions of the IRE lesions. Thermal damage due to Joule heating was ruled out via computer simulations. Sinusoidal bursts with a frequency equal or above 100 kHz did not cause thoracic movements and induced lesions equivalent to those obtained with conventional dc pulses when the applied voltage amplitude was sufficiently high. IRE efficacy dropped with increasing frequency. For 100 kHz bursts, it was estimated that the electric field threshold for IRE is about 1.4 kV/cm whereas that of dc pulses is about 0.5 kV/cm., This work was supported by the Ministry of Economy and Competitiveness of Spain through the grant TEC2014-52383-C3-R (TEC2014-52383-C3-2-R and TEC2014-52383-C3-3-R).
Repositorio Digital de la UPF
Publication Artículo científico (JournalArticle)

Electrochemical prevention of needle-tract seeding

  • Ivorra Cano, Antoni, 1974-
Needle-tract seeding refers to the implantation of tumor cells by contamination when instruments, such as biopsy needles, are employed to examine, excise or ablate a tumor. The incidence of this iatrogenic phenomenon is low but it entails serious consequences. Here, as a new method for preventing neoplasm seeding, it is proposed to cause electrochemical reactions at the instrument surface so that a toxic microenvironment is formed. In particular, the instrument shaft would act as the cathode and the tissues would act as the electrolyte in an electrolysis cell. By employing numerical models and experimental observations reported by researchers on Electrochemical Treatment of tumors, it is numerically showed that a sufficiently toxic environment of supraphysiological pH can be created in a few seconds without excessive heating. Then, by employing an ex vivo model consisting of meat pieces, validity of the conclusions provided by the numerical model concerning pH evolution is confirmed. Furthermore, a simplified in vitro model based on bacteria, instead of tumor cells, is implemented for showing the plausibility of the method. Depending on the geometry of the instrument, suitable current densities will probably range from about 5 mA/cm2 to 200 mA/cm2 and the duration of DC current delivery will range from a few seconds to a few minutes., AI’s research is currently supported by a Ramón y Cajal fellowship from the Spanish Ministry for Science and Innovation.
RiuNet. Repositorio Institucional de la Universitat Politécnica de Valéncia
Publication Artículo científico (JournalArticle)

Irreversible electroporation of the liver: is there a safe limit to the ablation volume?

  • Sánchez-Velázquez, Patricia
  • Castellví, Quim
  • Villanueva, A
  • Quesada, Rita
  • Pañella, C.
  • Cáceres, Marta
  • Dorcaratto, Dimitri
  • Andaluz, Anna
  • Moll, X.
  • Burdío Pinilla, José Miguel
  • Grande, Luis
  • Ivorra, A.
  • Burdío Pinilla, Fernando
  • Trujillo Guillen, Macarena|||0000-0003-4145-2188
  • Berjano, Enrique|||0000-0002-3247-2665
Irreversible electroporation is a fast-growing liver ablation technique. Although safety has been well documented in small ablations, our aim is to assess its safety and feasibility when a large portion of liver is ablated. Eighty-seven mice were subjected to high voltage pulses directly delivered across parallel plate electrodes comprising around 40% of mouse liver. One group consisted in 55 athymicnude, in which a tumor from the KM12C cell line was grown and the other thirty-two C57-Bl6 nontumoral mice. Both groups were subsequently divided into subsets according to the delivered field strength (1000V/cm, 2000V/cm) and whether or not they received anti-hyperkalemia therapy. Early mortality (less than 24hours post-IRE) in the 2000V/cm group was observed and revealed considerably higher mean potassium levels. In contrast, the animals subjected to a 2000V/cm field treated with the anti-hyperkalemia therapy had higher survival rates (OR=0.1, 95%CI=0.02–0.32, p<0.001). Early mortality also depended on the electric field magnitude of the IRE protocol, as mice given 1000V/cm survived longer than those given 2000V/cm (OR=4.7, 95%CI=1.8–11.8, p=0.001). Our findings suggest that ionic disturbances, mainly due to potassium alterations, should be warned and envisioned when large volume ablations are performed by IRE., This research was supported by the Spanish "Plan Estatal de Investigacion, Desarrollo e Innovacion Orientada a los Retos de la Sociedad" under Grant TEC2014-52383-C3 (TEC2014-52383-C3-1-R, TEC2014-52383-C3-2-R, and TEC2014-52383-C3-3-R), and by the Spanish "Plan Nacional de I + D + i del Ministerio de Ciencia e Innovacion" under Grants TEC2011-27133-C02 and TEC2010-17285.
Zaguán. Repositorio Digital de la Universidad de Zaragoza
Publication Artículo científico (JournalArticle)

Irreversible electroporation of the liver: Is there a safe limit to the ablation volume?

  • Sánchez-Velázquez, P.
  • Castellví, Q.
  • Villanueva, A.
  • Quesada, R.
  • Pañella, C.
  • Cáceres, M.
  • Dorcaratto, D.
  • Andaluz, A.
  • Moll, X.
  • Trujillo, M.
  • Burdió, J.M.
  • Berjano, E.
  • Grande, L.
  • Ivorra, A.
  • Burdió, F.
Irreversible electroporation is a fast-growing liver ablation technique. Although safety has been well documented in small ablations, our aim is to assess its safety and feasibility when a large portion of liver is ablated. Eighty-seven mice were subjected to high voltage pulses directly delivered across parallel plate electrodes comprising around 40% of mouse liver. One group consisted in 55 athymic-nude, in which a tumor from the KM12C cell line was grown and the other thirty-two C57-Bl6 non-tumoral mice. Both groups were subsequently divided into subsets according to the delivered field strength (1000 V/cm, 2000 V/cm) and whether or not they received anti-hyperkalemia therapy. Early mortality (less than 24 hours post-IRE) in the 2000 V/cm group was observed and revealed considerably higher mean potassium levels. In contrast, the animals subjected to a 2000 V/cm field treated with the anti-hyperkalemia therapy had higher survival rates (OR = 0.1, 95%CI = 0.02-0.32, p < 0.001). Early mortality also depended on the electric field magnitude of the IRE protocol, as mice given 1000 V/cm survived longer than those given 2000 V/cm (OR = 4.7, 95%CI = 1.8-11.8, p = 0.001). Our findings suggest that ionic disturbances, mainly due to potassium alterations, should be warned and envisioned when large volume ablations are performed by IRE.
Zaguán. Repositorio Digital de la Universidad de Zaragoza
Publication Artículo científico (JournalArticle)

Long-term effectiveness of irreversible electroporation in a murine model of colorectal liver metastasis

  • Sánchez-Velázquez, P.
  • Castellví, Q.
  • Villanueva, A.
  • Iglesias, M.
  • Quesada, R.
  • Pañella, C.
  • Cáceres, M.
  • Dorcaratto, D.
  • Andaluz, A.
  • Moll, X.
  • Burdío, J. M.
  • Grande, L.
  • Ivorra, A.
  • Burdío, F.
Irreversible electroporation (IRE) has recently gained in popularity as an ablative technique, however little is known about its oncological long-term outcomes. To determine the long-time survival of animals treated with a high dose of IRE and which histological changes it induces in tumoral tissue, IRE ablation was performed in forty-six athymic-nude mice with KM12C tumors implanted in the liver by applying electric current with different voltages (2000 V/cm, 1000 V/cm). The tumors were allowed to continue to grow until the animals reached the end-point criteria. Histology was harvested and the extent of tumor necrosis was semi-quantitatively assessed. IRE treatment with the 2000 V/cm protocol significantly prolonged median mouse survival from 74.3 ± 6.9 days in the sham group to 112.5 ± 15.2 days in the 2000 V/cm group. No differences were observed between the mean survival of the 1000 V/cm and the sham group (83.2 ± 16.4 days, p = 0.62). Histology revealed 63.05% ± 23.12 of tumor necrosis in animals of the 2000 V/cm group as compared to 17.50% ± 2.50 in the 1000 V/cm group and 25.6% ± 22.1 in the Sham group (p = 0.001). IRE prolonged the survival of animals treated with the highest electric field (2000 V/cm). The animals in this group showed significantly higher rate of tumoral necrosis.
Recercat. Dipósit de la Recerca de Catalunya
Publication Artículo científico (JournalArticle)

Electrical modeling of the influence of medium conductivity on electroporation

  • Ivorra Cano, Antoni, 1974-
  • Villemejane, Julien
  • Mir, Lluis M.
Electroporation is the phenomenon in which cell membrane permeability is increased by exposing the cell to short high electric field pulses. Experimental data show that the amount of permeabilization depends on the conductivity of the extracellular medium. If medium conductivity decreases then it is necessary to deliver a pulse of larger field amplitude in order to achieve the same effect. Models that do not take into account the permeabilization effect on the membrane conductivity cannot reproduce qualitatively the experimental observations. Here we employ an exponential function for describing the strong dependence of membrane conductivity on transmembrane potential. Combining that model with numerical methods we demonstrate that the dependence on medium conductivity can be explained as being the result of increased membrane conductance due to electroporation. As experimentally observed, extracellular conductivities of about 1 and 0.1 S m−1 yield very similar results, however, for lower conductivities (<0.01 S m−1) the model predicts that significantly higher field magnitudes will be required to achieve the same amount of permeabilization., This work was supported by grants from: CNRS, Institute of cancerology Gustave-Roussy, University Paris Sud, INCa (National Institute of Cancer, France—contract number 07/3D1616/Doc-54-3NG-NC) and French National Agency (ANR) through Nanoscience and Nanotechnology program (Nanopulsebiochip no. ANR-08-NANO-024). AI’s research is currently supported by a Ramon y Cajal/nfellowship from the Spanish Ministry for Science and Innovation.
Recercat. Dipósit de la Recerca de Catalunya
Publication Artículo científico (JournalArticle)

Electrochemical prevention of needle-tract seeding

  • Ivorra Cano, Antoni, 1974-
Needle-tract seeding refers to the implantation of tumor cells by contamination when instruments, such as biopsy needles, are employed to examine, excise or ablate a tumor. The incidence of this iatrogenic phenomenon is low but it entails serious consequences. Here, as a new method for preventing neoplasm seeding, it is proposed to cause electrochemical reactions at the instrument surface so that a toxic microenvironment is formed. In particular, the instrument shaft would act as the cathode and the tissues would act as the electrolyte in an electrolysis cell. By employing numerical models and experimental observations reported by researchers on Electrochemical Treatment of tumors, it is numerically showed that a sufficiently toxic environment of supraphysiological pH can be created in a few seconds without excessive heating. Then, by employing an ex vivo model consisting of meat pieces, validity of the conclusions provided by the numerical model concerning pH evolution is confirmed. Furthermore, a simplified in vitro model based on bacteria, instead of tumor cells, is implemented for showing the plausibility of the method. Depending on the geometry of the instrument, suitable current densities will probably range from about 5 mA/cm2 to 200 mA/cm2 and the duration of DC current delivery will range from a few seconds to a few minutes., AI’s research is currently supported by a Ramón y Cajal fellowship from the Spanish Ministry for Science and Innovation.
Recercat. Dipósit de la Recerca de Catalunya
Publication Artículo científico (JournalArticle)

Dependence of electroporation detection threshold on cell radius: an explanation to observations non compatible with Schwan’s equation model

  • Mercadal, Borja
  • Vernier, P. Thomas
  • Ivorra Cano, Antoni, 1974-
It is widely accepted that electroporation occurs when the cell transmembrane voltage induced by an external applied electric field reaches a threshold. Under this assumption, in order to trigger electroporation in a spherical cell, Schwan’s equation leads to an inversely proportional relationship between the cell radius and the minimum magnitude of the applied electric field. And, indeed, several publications report experimental evidences of an inverse relationship between the cell size and the field required to achieve electroporation. However, this dependence is not always observed or is not as steep as predicted by Schwan’s equation. The present numerical study attempts to explain these observations that do not fit Schwan’s equation on the basis of the interplay between cell membrane conductivity, permeability, and transmembrane voltage. For that, a single cell in suspension was modeled and the electric field necessary to achieve electroporation with a single pulse was determined according to two effectiveness criteria: a specific permeabilization level, understood as the relative area occupied by the pores during the pulse, and a final intracellular concentration of a molecule due to uptake by diffusion after the pulse, during membrane resealing. The results indicate that plausible model parameters can lead to divergent dependencies of the electric field threshold on the cell radius. These divergent dependencies were obtained through both criteria and using two different permeabilization models. This suggests that the interplay between cell membrane conductivity, permeability, and transmembrane voltage might be the cause of results which are noncompatible with the Schwan’s equation model., This work was supported by the Ministry of Economy and Competitiveness of Spain through Grant TEC2014-52383-C3-2-R. PTV received support from the Old Dominion University Frank Reidy Research Center for Bioelectrics and the Air Force Office of Scientific Research (FA9550-15-1-0517, FA9550-14-1-0123).
Recercat. Dipósit de la Recerca de Catalunya
Publication Artículo científico (JournalArticle)

Long-term effectiveness of irreversible electroporation in a murine model of colorectal liver metastasis

  • Ivorra Cano, Antoni, 1974-
  • Sánchez Velázquez, Patricia, 1985-
  • Castellví Fernández, Quim
  • Villanueva, Alberto
  • Iglesias Coma, Mar
  • Quesada Diez, Rita
  • Pañella Vilamú, Clara, 1987-
  • Cáceres Aguilar, Mario
  • Dorcaratto, Dimitri
  • Andaluz, Anna
  • Moll, Xavier
  • Burdío, José M.
  • Grande Posa, Luís
  • Burdío Pinilla, Fernando
Irreversible electroporation (IRE) has recently gained in popularity as an ablative technique, however little is known about its oncological long-term outcomes. To determine the long-time survival of animals treated with a high dose of IRE and which histological changes it induces in tumoral tissue, IRE ablation was performed in forty-six athymic-nude mice with KM12C tumors implanted in the liver by applying electric current with different voltages (2000 V/cm, 1000 V/cm). The tumors were allowed to continue to grow until the animals reached the end-point criteria. Histology was harvested and the extent of tumor necrosis was semi-quantitatively assessed. IRE treatment with the 2000 V/cm protocol significantly prolonged median mouse survival from 74.3 ± 6.9 days in the sham group to 112.5 ± 15.2 days in the 2000 V/cm group. No differences were observed between the mean survival of the 1000 V/cm and the sham group (83.2 ± 16.4 days, p = 0.62). Histology revealed 63.05% ± 23.12 of tumor necrosis in animals of the 2000 V/cm group as compared to 17.50% ± 2.50 in the 1000 V/cm group and 25.6% ± 22.1 in the Sham group (p = 0.001). IRE prolonged the survival of animals treated with the highest electric field (2000 V/cm). The animals in this group showed significantly higher rate of tumoral necrosis., This research was supported by the spanish government under grants TEC2011-27133-c02 and TEC2010-17285, and by the spanish “plan estatal de investigación, desarrollo e innovación orientada a los retos de la sociedad” under grant TEC2014–52383-c3-r (TEC2014–52383-c3-2-r and TEC2014–52383-c3-3-r).
Recercat. Dipósit de la Recerca de Catalunya
Publication Contribución de congreso (ConferenceOutput)

Modeling liver electrical conductivity during hypertonic injection

  • Castellví Fernández, Quim
  • Sánchez Velázquez, Patricia, 1985-
  • Moll, Xavier
  • Berjano, Enrique J.
  • Andaluz, Anna
  • Burdío Pinilla, Fernando
  • Bijnens, Bart
  • Ivorra Cano, Antoni, 1974-
Metastases in the liver frequently grow as scattered tumor nodules which neither can be removed by surgical resection nor focally ablated. Previously, we have proposed a novel technique based on irreversible electroporation which may be able to simultaneously treat all nodules in the liver while sparing healthy tissue. The proposed technique requires increasing the electrical conductivity of healthy liver by injecting a hypersaline solution through the portal vein. Aiming to assess the capability of increasing the global conductivity of the liver by means of hypersaline fluids, here it is presented a mathematical model which estimates the NaCl distribution within the liver and the resulting conductivity change. The model fuses wellestablished compartmental pharmacokinetic models of the organ with saline injection models employed for resuscitation treatments and it considers changes in sinusoidal blood viscosity due to the hypertonicity of the solution. Here it is also described a pilot experimental study in pigs in which different volumes of NaCl 20% (from 100 to 200 ml) were injected through the portal vein at different flow rates (from 53 to 171 ml/min). The in vivo conductivity results fit those obtained by the model, both quantitatively and qualitatively, being able to predict the maximum conductivity with a 14.6% average relative error. The maximum conductivity value was 0.44 S/m which corresponds to increasing four times the mean basal conductivity (0.11 S/m). The results suggest that the presented model is well suited for predicting on liver conductivity changes during hypertonic saline injection., Spanish Government; contract/grant number: TEC2014-52383-C3-1-R, TEC2014-52383-C3-2-R and TEC2014-52383-C3-3-R
Recercat. Dipósit de la Recerca de Catalunya
Publication Contribución de congreso (ConferenceOutput)

Charge counter for performing active charge-balance in miniaturized electrical stimulators

  • Becerra Fajardo, Laura
  • Ivorra Cano, Antoni, 1974-
Functional Electrical Stimulation (FES) has been explored in order to restore the capabilities of the nervous system in patients that suffer from paralysis. This area of research and of clinical practice greatly benefits from any technological improvement yielding miniaturization. In this regard, we recently proposed and demonstrated an innovative electrical stimulation method based on implanted microstimulators that operate as rectifiers of bursts of innocu-ous high frequency current supplied by skin electrodes, gener-ating low frequency currents that are capable of stimulating excitable tissues. We envision flexible ultrathin implants (di-ameters < 300 μm) containing ASICs that have advanced ca-pabilities, such as addressability and current control. As min-iaturization is the main aim of this method, the use of bulky DC-blocking capacitors (e.g. 10 μF) to accomplish zero net charge injection and avoid electrochemical tissue and electrode damage is highly inconvenient. As an alternative, here we present an active charge-balance method based on the use of a digital charge quantifier, whose operation is inspired in the functioning of the tipping bucket rain gauge. The system moni-tors the charge injection, matching the charge injected in the cathodal phase, with the charge injected in the anodal phase, generating a biphasic current waveform that adapts itself to possible current source mismatches. We have implemented a prototype built with discrete components which uses a capaci-tor of only 100 pF for the charge counter., AI’s research is supported by a Ramón y Cajal fellowship/nfrom the Spanish government and a Marie Curie grant/n(IRG 256376) from the European Commission. LBF’s research/nis supported by a scholarship from the UPF.
Recercat. Dipósit de la Recerca de Catalunya
Publication Artículo científico (JournalArticle)

Dynamics of cell death after conventional IRE and H-FIRE treatments

  • Mercadal, Borja
  • Beitel White, Natalie
  • Aycock, Kenneth N.
  • Castellví Fernández, Quim
  • Davalos, Rafael Vidal
  • Ivorra Cano, Antoni, 1974-
High-frequency irreversible electroporation (H-FIRE) has emerged as an alternative to conventional irreversible electroporation (IRE) to overcome the issues associated with neuromuscular electrical stimulation that appear in IRE treatments. In H-FIRE, the monopolar pulses typically used in IRE are replaced with bursts of short bipolar pulses. Currently, very little is known regarding how the use of a different waveform affects the cell death dynamics and mechanisms. In this study, human pancreatic adenocarcinoma cells were treated with a typical IRE protocol and various H-FIRE schemes with the same energized time. Cell viability, membrane integrity and Caspase 3/7 activity were assessed at different times after the treatment. In both treatments, we identified two different death dynamics (immediate and delayed) and we quantified the electric field ranges that lead to each of them. While in the typical IRE protocol, the electric field range leading to a delayed cell death is very narrow, this range is wider in H-FIRE and can be increased by reducing the pulse length. Membrane integrity in cells suffering a delayed cell death shows a similar time evolution in all treatments, however, Caspase 3/7 expression was only observed in cells treated with H-FIRE., This work was supported by the Ministry of Economy and Competitiveness of Spain (Grant No. TEC2014-52383-C3-2-R), the Pancreatic Cancer Action Network (Grant No. 16-65-IANN) and Cures Within Reach (Grant No. PUJFSANY). Antoni Ivorra gratefully acknowledges financial support by ICREA under the ICREA Academia programme.
Recercat. Dipósit de la Recerca de Catalunya
Publication Artículo científico (JournalArticle)

EView: an electric field visualization web platform for electroporation-based therapies

  • Perera Bel, Enric
  • Yagüe, Carlos
  • Mercadal, Borja
  • Ceresa, Mario
  • Beitel White, Natalie
  • Davalos, Rafael Vidal
  • González Ballester, Miguel Ángel, 1973-
  • Ivorra Cano, Antoni, 1974-
Background and objectives: Electroporation is the phenomenon by which cell membrane permeability to ions and macromolecules is increased when the cell is briefly exposed to high electric fields. In electroporation-based treatments, such exposure is typically performed by delivering high voltage pulses across needle electrodes in tissue. For a given tissue and pulsing protocol, an electric field magnitude threshold exists that must be overreached for treatment efficacy. However, it is hard to preoperatively infer the treatment volume because the electric field distribution intricately depends on the electrodes’ positioning and length, the applied voltage, and the electric conductivity of the treated tissues. For illustrating such dependencies, we have created EView (https://eview.upf.edu), a web platform that estimates the electric field distribution for arbitrary needle electrode locations and orientations and overlays it on 3D medical images. Methods: A client-server approach has been implemented to let the user set the electrode configuration easily on the web browser, whereas the simulation is computed on a dedicated server. By means of the finite element method, the electric field is solved in a 3D volume. For the sake of simplicity, only a homogeneous tissue is modeled, assuming the same properties for healthy and pathologic tissues. The non-linear dependence of tissue conductivity on the electric field due to the electroporation effect is modeled. The implemented model has been validated against a state of the art finite element solver, and the server has undergone a heavy load test to ensure reliability and to report execution times. Results: The electric field is rapidly computed for any electrode and tissue configuration, and alternative setups can be easily compared. The platform provides the same results as the state of the art finite element solver (Dice = 98.3 ± 0.4%). During the high load test, the server remained responsive. Simulations are computed in less than 2 min for simple cases consisting of two electrodes and take up to 40 min for complex scenarios consisting of 6 electrodes. Conclusions: With this free platform we provide expert and non-expert electroporation users a way to rapidly model the electric field distribution for arbitrary electrode configurations., This work was supported by the Ministry of Economy and Competitiveness of Spain (grant number TEC2014-52383-C3-2-R), the María de Maeztu Units of Excellence Programme (grant number MDM-2015-0502) and by the Spanish Ministry of Economy and Competitiveness under the Programme for the Formation of Doctors (grant number BES-2017-081164). Antoni Ivorra gratefully acknowledges the financial support by ICREA under the ICREA Academia programme.
Recercat. Dipósit de la Recerca de Catalunya
Publication Artículo científico (JournalArticle)

Modeling methods for treatment planning in overlapping electroporation treatments

  • Perera Bel, Enric
  • Mercandal, Borja
  • Garcia-Sanchez, Tomas
  • González Ballester, Miguel Ángel, 1973-
  • Ivorra Cano, Antoni, 1974-
Objective: Irreversible electroporation (IRE) is a non thermal tissue ablation therapy which is induced by applying high voltage waveforms across electrode pairs. When multiple electrode pairs are sequentially used, the treatment volume (TV) is typically computed as the geometric union of the TVs of individual pairs. However, this method neglects that some regions are exposed to overlapping treatments. Recently, a model describing cell survival probability was introduced which effectively predicted TV with overlapping fields in vivo. However, treatment overlap has yet to be quantified. This study characterizes TV overlap in a controlled in vitro setup with the two existing methods which are compared to an adapted logistic model proposed here. Methods: CHO cells were immobilized in agarose gel. Initially, we characterized the electric field threshold and the cell survival probability for overlapping treatments. Subsequently, we created a 2D setup where we compared and validated the accuracy of the different methods in predicting the TV. Results: Overlap can reduce the electric field threshold required to induce cell death, particularly for treatments with low pulse number. However, it does not have a major impact on TV in the models assayed here, and all the studied methods predict TV with similar accuracy. Conclusion: Treatment overlap has a minor influence in the TV for typical protocols found in IRE therapies. Significance: This study provides evidence that the modeling method used in most pre-clinical and clinical studies seems adequate.
Recercat. Dipósit de la Recerca de Catalunya
Publication Artículo científico (JournalArticle)

Avoiding neuromuscular stimulation in liver irreversible electroporation using radiofrequency electric fields

  • Castellví Fernández, Quim
  • Mercadal, Borja
  • Moll, Xavier
  • Fondevila, Dolors
  • Andaluz, Anna
  • Ivorra Cano, Antoni, 1974-
Electroporation based treatments typically consist in applying high voltage dc pulses. As an undesired side effect, these dc pulses cause electrical stimulation of excitable tissues such as motor nerves. In the present in vivo study, it was explored the use of bursts of sinusoidal voltage in the frequency range from 50 kHz to 2 MHz to induce irreversible electroporation (IRE) whilst avoiding neuromuscular stimulation. Series of 100 dc pulses or sinusoidal bursts, both with an individual duration of 100 μs, were delivered to rabbit liver through thin needles in a monopolar electrode configuration and thoracic movements were recorded with an accelerometer. Tissue samples were harvested three hours after treatment and later postprocessed to determine the dimensions of the IRE lesions. Thermal damage due to Joule heating was ruled out via computer simulations. Sinusoidal bursts with a frequency equal or above 100 kHz did not cause thoracic movements and induced lesions equivalent to those obtained with conventional dc pulses when the applied voltage amplitude was sufficiently high. IRE efficacy dropped with increasing frequency. For 100 kHz bursts, it was estimated that the electric field threshold for IRE is about 1.4 kV/cm whereas that of dc pulses is about 0.5 kV/cm., This work was supported by the Ministry of Economy and Competitiveness of Spain through the grant TEC2014-52383-C3-R (TEC2014-52383-C3-2-R and TEC2014-52383-C3-3-R).
Recercat. Dipósit de la Recerca de Catalunya
Publication Artículo científico (JournalArticle)

Avoiding nerve stimulation in irreversible electroporation: a numerical modeling study

  • Mercadal, Borja
  • Arena, Christopher B.
  • Davalos, Rafael Vidal
  • Ivorra Cano, Antoni, 1974-
Electroporation based treatments consist in applying one or multiple high voltage pulses to the tissues to be treated. As an undesired side effect, these pulses cause electrical stimulation of excitable tissues such as nerves and muscles. This increases the complexity of the treatments and may pose a risk to the patient. To minimize electrical stimulation during electroporation based treatments, it has been proposed to replace the commonly used monopolar pulses by bursts of short bipolar pulses. In the present study, we have numerically analyzed the rationale for such approach. We have compared different pulsing protocols in terms of their electroporation efficacy and their capability to trigger action potentials in nerves. For that, we have developed a modeling framework that combines numerical models of nerve fibers and experimental data on irreversible electroporation. Our results indicate that, by replacing the conventional relatively long monopolar pulses by bursts of short bipolar pulses, it is possible to ablate a large tissue region without triggering action potentials in a nearby nerve. Our models indicate that this is possible because, as the pulse length of these bipolar pulses is reduced, the stimulation thresholds raise faster than the irreversible electroporation thresholds. We propose that this different dependence on the pulse length is due to the fact that transmembrane charging for nerve fibers is much slower than that of cells treated by electroporation because of their geometrical differences., This work was supported by the Ministry of Economy and Competitiveness of Spain through the grant TEC2014-52383-C3-2-R. RVD’s research is supported by the National Institutes of Health under award number NIH 1R21 CA192041-01.