Laparoscopic partial splenectomy for giant cyst using a radiofrequency-assisted device: a case report

  • Quesada Diez, Rita
  • Poves Prim, José Ignacio
  • Iglesias Coma, Mar
  • Berjano, Enrique J.
  • Grande Posa, Luís
  • Burdío Pinilla, Fernando
Background: Although radiofrequency-assisted devices have sometimes been used in partial splenectomy, this is not a common technique. This report describes the first case of laparoscopic partial splenectomy using an RF-assisted device (Coolinside) which allows both coagulation and transection of the parenchyma and eventually the protective coagulation of the remnant side. Case presentation: A 27-year-old woman was found to have a giant hydatic cyst measuring 12.0 × 14.0 × 16.6 cm that mainly occupied the lower pole of the spleen and retroperitoneal space. The patient underwent a laparoscopic partial splenectomy using an RF-based device designed to accomplish both the coagulation and dissection of the splenic tissue. The estimated blood loss was less than 200 mL. Conclusions: Even though RF ablation has traditionally been used for hepatic parenchymal transection, it seems equally suited to partial splenectomy. This device seems to provide good results, minimizing blood loss during partial splenectomy; however, randomized trials will be necessary to see if the results are superior to those of other techniques., This work was partially supported by the Spanish “Programa Estatal de Investigación, Desarrollo e Innovación Orientada a los Retos de la Sociedad” under Grant TEC2014-52383-C3-R (TEC2014-52383-C3-1-R and TEC2014-52383-C3-3-R).
Repositorio Digital de la UPF
Publication Artículo científico (JournalArticle)

Long-term effectiveness of irreversible electroporation in a murine model of colorectal liver metastasis

  • Ivorra Cano, Antoni, 1974-
  • Sánchez Velázquez, Patricia, 1985-
  • Castellví Fernández, Quim
  • Villanueva, Alberto
  • Iglesias Coma, Mar
  • Quesada Diez, Rita
  • Pañella Vilamú, Clara, 1987-
  • Cáceres Aguilar, Mario
  • Dorcaratto, Dimitri
  • Andaluz, Anna
  • Moll, Xavier
  • Burdío, José M.
  • Grande Posa, Luís
  • Burdío Pinilla, Fernando
Irreversible electroporation (IRE) has recently gained in popularity as an ablative technique, however little is known about its oncological long-term outcomes. To determine the long-time survival of animals treated with a high dose of IRE and which histological changes it induces in tumoral tissue, IRE ablation was performed in forty-six athymic-nude mice with KM12C tumors implanted in the liver by applying electric current with different voltages (2000 V/cm, 1000 V/cm). The tumors were allowed to continue to grow until the animals reached the end-point criteria. Histology was harvested and the extent of tumor necrosis was semi-quantitatively assessed. IRE treatment with the 2000 V/cm protocol significantly prolonged median mouse survival from 74.3 ± 6.9 days in the sham group to 112.5 ± 15.2 days in the 2000 V/cm group. No differences were observed between the mean survival of the 1000 V/cm and the sham group (83.2 ± 16.4 days, p = 0.62). Histology revealed 63.05% ± 23.12 of tumor necrosis in animals of the 2000 V/cm group as compared to 17.50% ± 2.50 in the 1000 V/cm group and 25.6% ± 22.1 in the Sham group (p = 0.001). IRE prolonged the survival of animals treated with the highest electric field (2000 V/cm). The animals in this group showed significantly higher rate of tumoral necrosis., This research was supported by the spanish government under grants TEC2011-27133-c02 and TEC2010-17285, and by the spanish “plan estatal de investigación, desarrollo e innovación orientada a los retos de la sociedad” under grant TEC2014–52383-c3-r (TEC2014–52383-c3-2-r and TEC2014–52383-c3-3-r).
Repositorio Digital de la UPF
Publication Artículo científico (JournalArticle)

Development of a catheter-based technique for endoluminal radiofrequency sealing of pancreatic duct

  • Ewertowska, Elżbieta
  • Andaluz, Anna
  • Moll, Xavier
  • Aguilar, Adrià
  • Garcia, Felix
  • Fondevila, Dolors
  • Quesada Diez, Rita
  • Trujillo Guillén, Macarena
  • Burdío Pinilla, Fernando
  • Berjano, Enrique J.
introduction: Endoluminal sealing of the pancreatic duct by glue or sutures facilitates the management of the pancreatic stump. Our objective was to develop a catheter-based alternative for endoluminal radiofrequency (RF) sealing of the pancreatic duct. Materials and methods: We devised a novel RF ablation technique based on impedance-guided catheter pullback. First, bench tests were performed on ex vivo models to tune up the technique before the in vivo study, after which endoluminal RF sealing of a ∼10 cm non-transected pancreatic duct was conducted on porcine models using a 3 Fr catheter. After 30 days, sealing effectiveness was assessed by a permeability test and a histological analysis. Results: The RF technique was feasible in all cases and delivered ∼5 W of power on an initial impedance of 308 ± 60 Ω. Electrical impedance evolution was similar in all cases and provided guidance for modulating the pullback speed to avoid tissue sticking and achieve a continuous lesion. During the follow-up the animals rate of weight gain was significantly reduced (p < 0.05). Apart from signs of exocrine atrophy, no other postoperative complications were found. At necropsy, the permeability test failed and the catheter could not be reintroduced endoluminally, confirming that sealing had been successful. The histological analysis revealed a homogeneous exocrine atrophy along the ablated segment in all the animals. Conclusions: Catheter-based RF ablation could be used effectively and safely for endoluminal sealing of the pancreatic duct. The findings suggest that a fully continuous lesion may not be required to obtain complete exocrine atrophy., This work was supported by the Spanish Ministerio de Economía, Industria y Competitividad under “Plan Estatal de Investigación, Desarrollo e Innovación Orientada a los Retos de la Sociedad” (Grant TEC2014–52383–C3–R) and by the Spanish Ministerio de Ciencia, Innovación y Universidades under “Programa Estatal de I + D + i Orientada a los Retos de la Sociedad" (Grant: RTI2018-094357-B-C21 and –C22). Elżbieta Ewertowska has a Predoctoral Grant (BES-2015–073285) from the Ministry of Economy, Industry and Competitiveness (Government of Spain). Also funding was received from Secretaría de Estado de Investigación, Desarrollo e Innovación.
Repositorio Digital de la UPF
Publication Artículo científico (JournalArticle)

Impact of monopolar radiofrequency coagulation on intraoperative blood loss during liver resection: a prospective randomised controlled trial

  • Quesada Diez, Rita
  • Poves Prim, José Ignacio
  • Berjano, Enrique J.
  • Vilaplana, Carles
  • Andaluz, Anna
  • Moll, Xavier
  • Dorcaratto, Dimitri
  • Grande Posa, Luís
  • Burdío Pinilla, Fernando
PURPOSE: To evaluate the impact of using monopolar thermal coagulation based on radiofrequency (RF) currents on intraoperative blood loss during liver resection. MATERIALS AND METHODS: A prospective randomised controlled trial was planned. Patients undergoing hepatectomy were randomised into two groups. In the control group (n = 10), hemostasis was obtained with a combination of stitches, vessel-sealing bipolar RF systems, sutures or clips. In the monopolar radiofrequency coagulation (MRFC) group (n = 18), hemostasis was mainly obtained using an internally cooled monopolar RF electrode. RESULTS: No differences in demographic or clinical characteristics were found between groups. Mean blood loss during liver resection in the control group was more than twice that of the MRFC group (556 ± 471 ml vs. 225 ± 313 ml, p = .02). The adjusted mean bleeding/transection area was also significantly higher in the control group (7.0 ± 3.3 ml/cm2 vs. 2.8 ± 4.0 ml/cm2, p = .006). No significant differences were observed in the rate of complications between the groups. CONCLUSIONS: The findings suggest that the monopolar electrocoagulation created with an internally cooled RF electrode considerably reduces intraoperative blood loss during liver resection., This work was supported by a medical research grant from the Spanish Government (FIS PI080934) and by Spanish “Programa Estatal de Investigación, Desarrollo e Innovación Orientada a los Retos de la Sociedad” under Grant TEC2014–52383-C3-R (TEC2014–52383-C3–1-R and TEC2014–52383-C3–3-R)
Repositorio Digital de la UPF
Publication Artículo científico (JournalArticle)

Endoluminal radiofrequency ablation of the main pancreatic duct is a secure and effective method to produce pancreatic atrophy and to achieve stump closure

  • Andaluz, Anna
  • Ewertowska, Elżbieta
  • Moll, Xavier
  • Aguilar, Adrià
  • García Arnas, Félix
  • Fondevila, Dolors
  • Quesada Diez, Rita
  • Berjano, Enrique J.
  • Grande Posa, Luís
  • Burdío Pinilla, Fernando
Radiofrequency energy has been used both experimentally and clinically to manage the pancreatic remnant after distal pancreatectomies. Our goal was to determine whether endoluminal radiofrequency (RF) ablation of the main pancreatic duct in large animals would be more efficient than glue occlusion as an exocrine pancreatic atrophy-inducing procedure. Thirty-four Landrace pigs were assigned to either the transpapilar (n = 16) or transection (n = 18) groups. The transection implied the pancreas neck was severed. In each of these groups the remaining distal pancreatic duct was occluded either by RF or by glue. In the transpapilar group complete atrophy was observed in all the RF cases, while atrophy was incomplete in all the members of the glue subgroup. The failure rate of the main pancreatic duct (usually expressed by a pseudocyst) in the transection groups was dramatically higher in the glue subgroup than the RF subgroups (9 out of 9 and 1 out of 9, respectively) and postoperative mortality occurred only in the glue subgroup (3 out of 9). These results show the superiority of endoluminal RF ablation over glue for main pancreatic duct occlusion, as seen by the degree of atrophy and fewer postoperative pancreatic fistulas., This work was supported by the Spanish Ministerio de Economía, Industria y Competitividad under the “Plan Estatal de Investigación, Desarrollo e Innovación Orientada a los Retos de la Sociedad” Grant TEC2014–52383–C3–R (TEC2014–52383–C3–1–R and TEC2014–52383–C3–3–R). Elzbieta Ewertowska has a Predoctoral Grant (BES-2015–073285) from the Ministry of Economy, Industry and Competitiveness (Government of Spain).
Recercat. Dipósit de la Recerca de Catalunya
Publication Artículo científico (JournalArticle)

Development of a catheter-based technique for endoluminal radiofrequency sealing of pancreatic duct

  • Ewertowska, Elżbieta
  • Andaluz, Anna
  • Moll, Xavier
  • Aguilar, Adrià
  • Garcia, Felix
  • Fondevila, Dolors
  • Quesada Diez, Rita
  • Trujillo Guillén, Macarena
  • Burdío Pinilla, Fernando
  • Berjano, Enrique J.
introduction: Endoluminal sealing of the pancreatic duct by glue or sutures facilitates the management of the pancreatic stump. Our objective was to develop a catheter-based alternative for endoluminal radiofrequency (RF) sealing of the pancreatic duct. Materials and methods: We devised a novel RF ablation technique based on impedance-guided catheter pullback. First, bench tests were performed on ex vivo models to tune up the technique before the in vivo study, after which endoluminal RF sealing of a ∼10 cm non-transected pancreatic duct was conducted on porcine models using a 3 Fr catheter. After 30 days, sealing effectiveness was assessed by a permeability test and a histological analysis. Results: The RF technique was feasible in all cases and delivered ∼5 W of power on an initial impedance of 308 ± 60 Ω. Electrical impedance evolution was similar in all cases and provided guidance for modulating the pullback speed to avoid tissue sticking and achieve a continuous lesion. During the follow-up the animals rate of weight gain was significantly reduced (p < 0.05). Apart from signs of exocrine atrophy, no other postoperative complications were found. At necropsy, the permeability test failed and the catheter could not be reintroduced endoluminally, confirming that sealing had been successful. The histological analysis revealed a homogeneous exocrine atrophy along the ablated segment in all the animals. Conclusions: Catheter-based RF ablation could be used effectively and safely for endoluminal sealing of the pancreatic duct. The findings suggest that a fully continuous lesion may not be required to obtain complete exocrine atrophy., This work was supported by the Spanish Ministerio de Economía, Industria y Competitividad under “Plan Estatal de Investigación, Desarrollo e Innovación Orientada a los Retos de la Sociedad” (Grant TEC2014–52383–C3–R) and by the Spanish Ministerio de Ciencia, Innovación y Universidades under “Programa Estatal de I + D + i Orientada a los Retos de la Sociedad" (Grant: RTI2018-094357-B-C21 and –C22). Elżbieta Ewertowska has a Predoctoral Grant (BES-2015–073285) from the Ministry of Economy, Industry and Competitiveness (Government of Spain). Also funding was received from Secretaría de Estado de Investigación, Desarrollo e Innovación.
Recercat. Dipósit de la Recerca de Catalunya
Publication Artículo científico (JournalArticle)

Long-term effectiveness of irreversible electroporation in a murine model of colorectal liver metastasis

  • Ivorra Cano, Antoni, 1974-
  • Sánchez Velázquez, Patricia, 1985-
  • Castellví Fernández, Quim
  • Villanueva, Alberto
  • Iglesias Coma, Mar
  • Quesada Diez, Rita
  • Pañella Vilamú, Clara, 1987-
  • Cáceres Aguilar, Mario
  • Dorcaratto, Dimitri
  • Andaluz, Anna
  • Moll, Xavier
  • Burdío, José M.
  • Grande Posa, Luís
  • Burdío Pinilla, Fernando
Irreversible electroporation (IRE) has recently gained in popularity as an ablative technique, however little is known about its oncological long-term outcomes. To determine the long-time survival of animals treated with a high dose of IRE and which histological changes it induces in tumoral tissue, IRE ablation was performed in forty-six athymic-nude mice with KM12C tumors implanted in the liver by applying electric current with different voltages (2000 V/cm, 1000 V/cm). The tumors were allowed to continue to grow until the animals reached the end-point criteria. Histology was harvested and the extent of tumor necrosis was semi-quantitatively assessed. IRE treatment with the 2000 V/cm protocol significantly prolonged median mouse survival from 74.3 ± 6.9 days in the sham group to 112.5 ± 15.2 days in the 2000 V/cm group. No differences were observed between the mean survival of the 1000 V/cm and the sham group (83.2 ± 16.4 days, p = 0.62). Histology revealed 63.05% ± 23.12 of tumor necrosis in animals of the 2000 V/cm group as compared to 17.50% ± 2.50 in the 1000 V/cm group and 25.6% ± 22.1 in the Sham group (p = 0.001). IRE prolonged the survival of animals treated with the highest electric field (2000 V/cm). The animals in this group showed significantly higher rate of tumoral necrosis., This research was supported by the spanish government under grants TEC2011-27133-c02 and TEC2010-17285, and by the spanish “plan estatal de investigación, desarrollo e innovación orientada a los retos de la sociedad” under grant TEC2014–52383-c3-r (TEC2014–52383-c3-2-r and TEC2014–52383-c3-3-r).
Recercat. Dipósit de la Recerca de Catalunya
Publication Artículo científico (JournalArticle)

Endoluminal radiofrequency ablation of the main pancreatic duct is a secure and effective method to produce pancreatic atrophy and to achieve stump closure

  • Andaluz, Anna
  • Ewertowska, Elżbieta
  • Moll, Xavier
  • Aguilar, Adrià
  • García Arnas, Félix
  • Fondevila, Dolors
  • Quesada Diez, Rita
  • Berjano, Enrique J.
  • Grande Posa, Luís
  • Burdío Pinilla, Fernando
Radiofrequency energy has been used both experimentally and clinically to manage the pancreatic remnant after distal pancreatectomies. Our goal was to determine whether endoluminal radiofrequency (RF) ablation of the main pancreatic duct in large animals would be more efficient than glue occlusion as an exocrine pancreatic atrophy-inducing procedure. Thirty-four Landrace pigs were assigned to either the transpapilar (n = 16) or transection (n = 18) groups. The transection implied the pancreas neck was severed. In each of these groups the remaining distal pancreatic duct was occluded either by RF or by glue. In the transpapilar group complete atrophy was observed in all the RF cases, while atrophy was incomplete in all the members of the glue subgroup. The failure rate of the main pancreatic duct (usually expressed by a pseudocyst) in the transection groups was dramatically higher in the glue subgroup than the RF subgroups (9 out of 9 and 1 out of 9, respectively) and postoperative mortality occurred only in the glue subgroup (3 out of 9). These results show the superiority of endoluminal RF ablation over glue for main pancreatic duct occlusion, as seen by the degree of atrophy and fewer postoperative pancreatic fistulas., This work was supported by the Spanish Ministerio de Economía, Industria y Competitividad under the “Plan Estatal de Investigación, Desarrollo e Innovación Orientada a los Retos de la Sociedad” Grant TEC2014–52383–C3–R (TEC2014–52383–C3–1–R and TEC2014–52383–C3–3–R). Elzbieta Ewertowska has a Predoctoral Grant (BES-2015–073285) from the Ministry of Economy, Industry and Competitiveness (Government of Spain).
Recercat. Dipósit de la Recerca de Catalunya
Publication Artículo científico (JournalArticle)

Impact of monopolar radiofrequency coagulation on intraoperative blood loss during liver resection: a prospective randomised controlled trial

  • Quesada Diez, Rita
  • Poves Prim, José Ignacio
  • Berjano, Enrique J.
  • Vilaplana, Carles
  • Andaluz, Anna
  • Moll, Xavier
  • Dorcaratto, Dimitri
  • Grande Posa, Luís
  • Burdío Pinilla, Fernando
PURPOSE: To evaluate the impact of using monopolar thermal coagulation based on radiofrequency (RF) currents on intraoperative blood loss during liver resection. MATERIALS AND METHODS: A prospective randomised controlled trial was planned. Patients undergoing hepatectomy were randomised into two groups. In the control group (n = 10), hemostasis was obtained with a combination of stitches, vessel-sealing bipolar RF systems, sutures or clips. In the monopolar radiofrequency coagulation (MRFC) group (n = 18), hemostasis was mainly obtained using an internally cooled monopolar RF electrode. RESULTS: No differences in demographic or clinical characteristics were found between groups. Mean blood loss during liver resection in the control group was more than twice that of the MRFC group (556 ± 471 ml vs. 225 ± 313 ml, p = .02). The adjusted mean bleeding/transection area was also significantly higher in the control group (7.0 ± 3.3 ml/cm2 vs. 2.8 ± 4.0 ml/cm2, p = .006). No significant differences were observed in the rate of complications between the groups. CONCLUSIONS: The findings suggest that the monopolar electrocoagulation created with an internally cooled RF electrode considerably reduces intraoperative blood loss during liver resection., This work was supported by a medical research grant from the Spanish Government (FIS PI080934) and by Spanish “Programa Estatal de Investigación, Desarrollo e Innovación Orientada a los Retos de la Sociedad” under Grant TEC2014–52383-C3-R (TEC2014–52383-C3–1-R and TEC2014–52383-C3–3-R)
Recercat. Dipósit de la Recerca de Catalunya
Publication Artículo científico (JournalArticle)

Laparoscopic partial splenectomy for giant cyst using a radiofrequency-assisted device: a case report

  • Quesada Diez, Rita
  • Poves Prim, José Ignacio
  • Iglesias Coma, Mar
  • Berjano, Enrique J.
  • Grande Posa, Luís
  • Burdío Pinilla, Fernando
Background: Although radiofrequency-assisted devices have sometimes been used in partial splenectomy, this is not a common technique. This report describes the first case of laparoscopic partial splenectomy using an RF-assisted device (Coolinside) which allows both coagulation and transection of the parenchyma and eventually the protective coagulation of the remnant side. Case presentation: A 27-year-old woman was found to have a giant hydatic cyst measuring 12.0 × 14.0 × 16.6 cm that mainly occupied the lower pole of the spleen and retroperitoneal space. The patient underwent a laparoscopic partial splenectomy using an RF-based device designed to accomplish both the coagulation and dissection of the splenic tissue. The estimated blood loss was less than 200 mL. Conclusions: Even though RF ablation has traditionally been used for hepatic parenchymal transection, it seems equally suited to partial splenectomy. This device seems to provide good results, minimizing blood loss during partial splenectomy; however, randomized trials will be necessary to see if the results are superior to those of other techniques., This work was partially supported by the Spanish “Programa Estatal de Investigación, Desarrollo e Innovación Orientada a los Retos de la Sociedad” under Grant TEC2014-52383-C3-R (TEC2014-52383-C3-1-R and TEC2014-52383-C3-3-R).
Dipòsit Digital de Documents de la UAB
Publication Artículo científico (JournalArticle)

Focused transhepatic electroporation mediated by hypersaline infusion through the portal vein in rat model, preliminary results on differential conductivity

  • Pañella, Clara
  • Castellví, Quim|||0000-0002-7095-1181
  • Moll, Xavier|||0000-0002-2992-9361
  • Quesada, R.|||0000-0002-8264-0356
  • Villanueva, Alejandro|||0000-0001-5164-0006
  • Iglesias, Mar|||0000-0002-2274-4671
  • Naranjo-Hans, Dolores|||0000-0002-4089-047X
  • Sánchez Velázquez, Patricia|||0000-0002-7902-3920
  • Andaluz Martínez, Anna|||0000-0001-8097-8110
  • Grande, L.|||0000-0001-9146-9004
  • Ivorra, Antoni|||0000-0001-7718-8767
  • Burdío, Fernando|||0000-0003-3038-0086
Spread hepatic tumours are not suitable for treatment either by surgery or conventional ablation methods. The aim of this study was to evaluate feasibility and safety of selectively increasing the healthy hepatic conductivity by the hypersaline infusion (HI) through the portal vein. We hypothesize this will allow simultaneous safe treatment of all nodules by irreversible electroporation (IRE) when applied in a transhepatic fashion. Sprague Dawley (Group A, n = 10) and Athymic rats with implanted hepatic tumour (Group B, n = 8) were employed. HI was performed (NaCl 20%, 3.8 mL/Kg) by trans-splenic puncture. Deionized serum (40 mL/Kg) and furosemide (2 mL/Kg) were simultaneously infused through the jugular vein to compensate hypernatremia. Changes in conductivity were monitored in the hepatic and tumour tissue. The period in which hepatic conductivity was higher than tumour conductivity was defined as the therapeutic window (TW). Animals were monitored during 1-month follow-up. The animals were sacrificed and selective samples were used for histological analysis. The overall survival rate was 82.4% after the HI protocol. The mean maximum hepatic conductivity after HI was 2.7 and 3.5 times higher than the baseline value, in group A and B, respectively. The mean maximum hepatic conductivity after HI was 1.4 times higher than tumour tissue in group B creating a TW to implement selective IRE. HI through the portal vein is safe when the hypersaline overload is compensated with deionized serum and it may provide a TW for focused IRE treatment on tumour nodules.
Dipòsit Digital de Documents de la UAB
Publication Artículo científico (JournalArticle)

Endoluminal radiofrequency ablation of the main pancreatic duct is a secure and effective method to produce pancreatic atrophy and to achieve stump closure

  • Andaluz Martínez, Anna|||0000-0001-8097-8110
  • Ewertowska, Elzbieta
  • Moll, Xavier|||0000-0002-2992-9361
  • Aguilar Catalán, Adrià|||0000-0003-2403-9383
  • García Arnas, Félix|||0000-0001-6651-3173
  • Fondevila, Dolors|||0000-0001-7443-0175
  • Quesada, Rita
  • Berjano, Enrique|||0000-0002-3247-2665
  • Grande, L|||0000-0001-9146-9004
  • Burdío, Fernando|||0000-0003-3038-0086
Radiofrequency energy has been used both experimentally and clinically to manage the pancreatic remnant after distal pancreatectomies. our goal was to determine whether endoluminal radiofrequency (RF) ablation of the main pancreatic duct in large animals would be more efficient than glue occlusion as an exocrine pancreatic atrophy-inducing procedure. thirty-four Landrace pigs were assigned to either the transpapilar (n = 16) or transection (n = 18) groups. The transection implied the pancreas neck was severed. In each of these groups the remaining distal pancreatic duct was occluded either by RF or by glue. In the transpapilar group complete atrophy was observed in all the RF cases, while atrophy was incomplete in all the members of the glue subgroup. the failure rate of the main pancreatic duct (usually expressed by a pseudocyst) in the transection groups was dramatically higher in the glue subgroup than the RF subgroups (9 out of 9 and 1 out of 9, respectively) and postoperative mortality occurred only in the glue subgroup (3 out of 9). These results show the superiority of endoluminal RF ablation over glue for main pancreatic duct occlusion, as seen by the degree of atrophy and fewer postoperative pancreatic fistulas.
Dipòsit Digital de Documents de la UAB
Publication Artículo científico (JournalArticle)

Long-term effectiveness of irreversible electroporation in a murine model of colorectal liver metastasis

  • Sánchez Velázquez, Patricia|||0000-0002-7902-3920
  • Castellví, Quim|||0000-0002-7095-1181
  • Villanueva Garatachea, Alberto
  • Iglesias, Mar|||0000-0002-2274-4671
  • Quesada, R.|||0000-0002-8264-0356
  • Pañella, Clara
  • Cáceres, Marta|||0000-0002-4100-2542
  • Dorcaratto, Dimitri
  • Andaluz Martínez, Anna|||0000-0001-8097-8110
  • Moll, Xavier|||0000-0002-2992-9361
  • Burdio, José Miguel
  • Grande, L.|||0000-0001-9146-9004
  • Ivorra, Antoni|||0000-0001-7718-8767
  • Burdío, Fernando|||0000-0003-3038-0086
Irreversible electroporation (IRE) has recently gained in popularity as an ablative technique, however little is known about its oncological long-term outcomes. To determine the long-time survival of animals treated with a high dose of IRE and which histological changes it induces in tumoral tissue, IRE ablation was performed in forty-six athymic-nude mice with KM12C tumors implanted in the liver by applying electric current with different voltages (2000V/cm, 1000V/cm). The tumors were allowed to continue to grow until the animals reached the end-point criteria. Histology was harvested and the extent of tumor necrosis was semi-quantitatively assessed. IRE treatment with the 2000V/cm protocol significantly prolonged median mouse survival from 74.3±6.9 days in the sham group to 112.5±15.2 days in the 2000V/cm group. No differences were observed between the mean survival of the 1000V/cm and the sham group (83.2±16.4 days, p=0.62). Histology revealed 63.05%±23.12 of tumor necrosis in animals of the 2000V/cm group as compared to 17.50%±2.50 in the 1000V/cm group and 25.6%±22.1 in the Sham group (p=0.001). IRE prolonged the survival of animals treated with the highest electric field (2000V/cm). The animals in this group showed significantly higher rate of tumoral necrosis.
Dipòsit Digital de Documents de la UAB
Publication Artículo científico (JournalArticle)

Hypersaline Infusion Protocol through the Portal Vein may Focus Electroporation on Tumor Tissue, but is it really Safe? Preliminary Results

  • Pañella, Clara
  • Moll, Xavier|||0000-0002-2992-9361
  • Quesada, R.|||0000-0002-8264-0356
  • Villanueva Garatachea, Alberto
  • Iglesias, Mar|||0000-0002-2274-4671
  • Andaluz Martínez, Anna|||0000-0001-8097-8110
  • Lucía, O.
  • Sánchez Velázquez, Patricia|||0000-0002-7902-3920
  • Grande, L.|||0000-0001-9146-9004
  • Burdío, Fernando|||0000-0003-3038-0086
Introduction: Irreversible Electroporation (IRE) is highly dependent on the electrical conductivity of the tissue and the high conductivity of tumor tissue, which leads to a lower field than in the surrounding healthy tissue. Hypersaline Infusion (HI) through the portal vein focuses IRE on scattered liver tumors, by creating a differential conductivity between the different types of tissue. The aim of this study is to determine the effects of the HI protocol on the hepatic and histological biochemical results. Methods: Ten male Sprague Dawley rats were used for HI protocol. Blood samples were collected at pre-, immediately post-, 24-hrs, 72-hrs, 1-week and 3-weeks post-HI. All the animals were sacrificed after one-month follow-up in order to collect histological samples. Results: The mortality rate in this procedure reached 30% (3/10). Only the pH and transaminases at 24-hrs were significantly and directly linked to mortality (p=0.036 and p=0.004, respectively). The three non-surviving animals had a four-time higher AST level at 24-hrs. Natremia normalized at 24-hrs post-HI. Statistically significant differences were found in hepatic necrosis between the non-surviving (n=3) and surviving rats (n=7) (30.67 ± 10.97 vs. 2.86 ± 7.56% respectively, p=0.01). Discussion: HI through the portal system involves a significant risk of possibly lethal cytolysis and acidosis. Therefore, compensatory measures and a reduced saline overload are warranted to improve the survival rates.
Dipòsit Digital de Documents de la UAB
Publication Artículo científico (JournalArticle)

A clinically oriented computer model for radiofrequency ablation of hepatic tissue with internally cooled wet electrode

  • Ewertowska, Elzbieta
  • Quesada, R.|||0000-0002-8264-0356
  • Radosevic, Aleksandar
  • Andaluz Martínez, Anna|||0000-0001-8097-8110
  • Moll, Xavier|||0000-0002-2992-9361
  • García Arnas, Félix.|||0000-0001-6651-3173
  • Berjano, Enrique|||0000-0002-3247-2665
  • Burdío, Fernando|||0000-0003-3038-0086
  • Trujillo Guillén, Macarena|||0000-0003-4145-2188
Purpose: To improve the computer modelling of radiofrequency ablation (RFA) by internally cooled wet (ICW) electrodes with added clinically oriented features. Methods: An improved RFA computer model by ICW electrode included: (1) a realistic spatial distribution of the infused saline, and (2) different domains to distinguish between healthy tissue, saline-infused tumour, and non-infused tumour, under the assumption that infused saline is retained within the tumour boundary. A realistic saline spatial distribution was obtained from an in vivo pig liver study. The computer results were analysed in terms of impedance evolution and coagulation zone (CZ) size, and were compared to the results of clinical trials conducted on 17 patients with the same ICW electrode. Results: The new features added to the model provided computer results that matched well with the clinical results. No roll-offs occurred during the 4-min ablation. CZ transversal diameter (4.10 ± 0.19 cm) was similar to the computed diameter (4.16 cm). Including the tumour and saline infusion in the model involved (1) a reduction of the initial impedance by 10 - 20 Ω, (2) a delay in roll-off of 20 s and 70 - 100 s, respectively, and (3) 18 - 31% and 22 - 36% larger CZ size, respectively. The saline spatial distribution geometry was also seen to affect roll-off delay and CZ size. Conclusions: Using a three-compartment model and a realistic saline spatial distribution notably improves the match with the outcome of the clinical trials.
Dipòsit Digital de Documents de la UAB
Publication Artículo científico (JournalArticle)

Development of a catheter-based technique for endoluminal radiofrequency sealing of pancreatic duct

  • Ewertowska, Elzbieta
  • Andaluz Martínez, Anna|||0000-0001-8097-8110
  • Moll, Xavier|||0000-0002-2992-9361
  • Aguilar Catalán, Adrià|||0000-0003-2403-9383
  • García Arnas, Félix|||0000-0001-6651-3173
  • Fondevila, Dolors|||0000-0001-7443-0175
  • Quesada, R.|||0000-0002-8264-0356
  • Trujillo Guillén, Macarena|||0000-0003-4145-2188
  • Burdío, Fernando|||0000-0003-3038-0086
  • Berjano, Enrique|||0000-0002-3247-2665
Introduction: Endoluminal sealing of the pancreatic duct by glue or sutures facilitates the management of the pancreatic stump. Our objective was to develop a catheter-based alternative for endoluminal radiofrequency (RF) sealing of the pancreatic duct. Materials and methods: We devised a novel RF ablation technique based on impedance-guided catheter pullback. First, bench tests were performed on ex vivo models to tune up the technique before the in vivo study, after which endoluminal RF sealing of a ∼10 cm non-transected pancreatic duct was conducted on porcine models using a 3 Fr catheter. After 30 days, sealing effectiveness was assessed by a permeability test and a histological analysis. Results: The RF technique was feasible in all cases and delivered ∼5 W of power on an initial impedance of 308 ± 60 Ω. Electrical impedance evolution was similar in all cases and provided guidance for modulating the pullback speed to avoid tissue sticking and achieve a continuous lesion. During the follow-up the animals rate of weight gain was significantly reduced (p < 0.05). Apart from signs of exocrine atrophy, no other postoperative complications were found. At necropsy, the permeability test failed and the catheter could not be reintroduced endoluminally, confirming that sealing had been successful. The histological analysis revealed a homogeneous exocrine atrophy along the ablated segment in all the animals. Conclusions: Catheter-based RF ablation could be used effectively and safely for endoluminal sealing of the pancreatic duct. The findings suggest that a fully continuous lesion may not be required to obtain complete exocrine atrophy.