- Oyarzun Domeño, Anne
- Cia Alonso, Izaskun
- Echeverría Chasco, Rebeca
- Fernández Seara, María Asunción
- Martín Moreno, Paloma L.
- García Fernández, Nuria
- Bastarrika, Gorka
- Navallas Irujo, Javier
- Villanueva Larre, Arantxa
In clinical renal assessment, image registration plays a pivotal role, as patient movement during data acquisition can
significantly impede image post-processing and the accurate estimation of hemodynamic parameters. This study introduces
a deep learning-based image registration framework specifically for arterial spin labeling (ASL) imaging. ASL is a
magnetic resonance imaging technique that modifies the longitudinal magnetization of blood perfusing the kidney using a
series of radiofrequency pulses combined with slice-selective gradients. After tagging the arterial blood, label images are
captured following a delay, allowing the tagged blood bolus to enter the renal tissue, while control images are acquired
without tagging the arterial spins. Given that perfusion maps are generated at the pixel level by subtracting control images
from label images and considering the relatively small signal intensity difference, precise alignment of these images is
crucial to minimize motion artefacts and prevent significant errors in perfusion calculations. Moreover, due to the extended
ASL acquisition times and the anatomical location of the kidneys, renal images are often susceptible to pulsation,
peristalsis, and breathing motion. These motion-induced noises and other instabilities can adversely affect ASL imaging
outcomes, making image registration essential. However, research on renal MRI registration, particularly with respect to
learning-based techniques, remains limited, with even less focus on renal ASL. Our study proposes a learning-based image
registration approach that builds upon VoxelMorph and introduces groupwise inference as a key enhancement. The dataset
includes 2448 images of transplanted kidneys (TK) and 2456 images of healthy kidneys (HK). We compared the automatic
image registration results with the widely recognized optimization method Elastix. The model’s performance was evaluated using the mean structural similarity index (MSSIM), normalized correlation coefficient (NCC), temporal signal-tonoise ratio (TSNR) of the samples, and the mean cortical signal (CSIM) in perfusion-weighted images, thereby extending
the evaluation beyond traditional similarity-based metrics. Our method achieved superior image registration performance,
with peak NCC (0.987 ± 0.006) and MSSIM (0.869 ± 0.048) values in the kidney region, significantly surpassing Elastix
and the unregistered series (p\ 0.05) on TK and HK datasets. Regularization analysis showed that higher k values (1, 2)
produced smoother deformation fields, while moderate k values (0.5, 0.9) balanced smoothness and detail, maintaining low
non-positive Jacobian percentages (\1%) comparable to Elastix. Additionally, our method improved CSIM by 14.3%
(2.304 ± 1.167) and TSNR by 13.1% (3.888 ± 2.170) in TK, and achieved up to 13.2% (CSIM) and 29.8% (TSNR)
enhancements in HK, demonstrating robustness and improved signal quality across datasets and acquisition techniques., Open access funding provided by Universidad Pública de Navarra. Project PC181-182 RM-RENAL, supported by the Department of University, Innovation and Digital Transformation (Government of Navarre). The author receives a PhD scholarship number 0011-0537-2021-000050 from Department of University, Innovation and Digital Transformation (Government of Navarre).