Pasar al contenido principal

Resultados relacionados

Resultados totales (Incluyendo duplicados): 15
Encontrada(s) 1 página(s)

Repisalud
Publicación Artículo científico (JournalArticle)

A clinical perspective on the utility of alpha 1 antichymotrypsin for the early diagnosis of calcific aortic stenosis

  • Martin-Rojas, Tatiana
  • Mourino-Alvarez, Laura
  • Gil-Dones, Felix
  • de la Cuesta, Fernando
  • Rosello-Lleti, Esther
  • Laborde, Carlos M.
  • Rivera, Miguel
  • Fernando Lopez-Almodovar, Luis
  • Lopez, Juan Antonio
  • Akerstrom, Finn
  • Padial, Luis R.
  • Barderas, Maria G
Background: Calcific aortic stenosis (CAS) is the most common heart valve disease in the elderly, representing an important economic and social burden in developed countries. Currently, there is no way to predict either the onset or progression of CAS, emphasizing the need to identify useful biomarkers for this condition. Methods: We performed a multi-proteomic analysis on different kinds of samples from CAS patients and healthy donors: tissue, secretome and plasma. The results were validated in an independent cohort of subjects by immunohistochemistry, western blotting and selected reaction monitoring. Results: Alpha 1 antichymotrypsin (AACT) abundance was altered in the CAS samples, as confirmed in the validation phase. The significant changes observed in the amounts of this protein strongly suggest that it could be involved in the molecular mechanisms underlying CAS. In addition, our results suggest there is enhanced release of AACT into the extracellular fluids when the disease commences. Conclusions: The significant increase of AACT in CAS patients suggests it fulfils an important role in the physiopathology of this disease. These results permit us to propose that AACT may serve as a potential marker for the diagnosis of CAS, with considerable clinical value.
Repisalud
Publicación Artículo científico (JournalArticle)

Kalirin and CHD7: novel endothelial dysfunction indicators in circulating extracellular vesicles from hypertensive patients with albuminuria

  • de la Cuesta, Fernando
  • Baldan-Martin, Montserrat
  • Moreno-Luna, Rafael
  • Alvarez-Llamas, Gloria
  • Gonzalez-Calero, Laura
  • Mourino-Alvarez, Laura
  • Sastre-Oliva, Tamara
  • Lopez, Juan Antonio
  • Vazquez, Jesus
  • Ruiz-Hurtado, Gema
  • Segura, Julian
  • Vivanco, Fernando
  • Ruilope, Luis M
  • Barderas, Maria G
Despite of the great advances in anti-hypertensive therapies, many patients under Renin-Angiotensin-System (RAS) suppression develop albuminuria, which is a clear indicator of therapeutic inefficiency. Hence, indicators of vascular function are needed to assess patients' condition and help deciding future therapies. Proteomic analysis of circulating extracellular vesicles (EVs) showed two proteins, kalirin and chromodomain-helicase-DNA-binding protein 7 (CHD7), increased in albuminuric patients. A positive correlation of both with the expression of the endothelial activation marker E-selectin was found in EVs. In vitro analysis using TNFa-treated adult human endothelial cells proved their involvement in endothelial cell activation. Hence, we propose protein levels of kalirin and CHD7 in circulating EVs as novel endothelial dysfunction markers to monitor vascular condition in hypertensive patients with albuminuria.
RiuNet. Repositorio Institucional de la Universitat Politécnica de Valéncia
Publicación Artículo científico (JournalArticle)

Lanthanum tungstate membranes for H-2 extraction and CO2 utilization: Fabrication strategies based on sequential tape casting and plasma-spray physical vapor deposition

  • Ivanova, M. E.
  • Deibert, W.
  • Marcano, D.
  • Mauer, G.
  • Meulenberg, W. A.
  • Bram, M.
  • Vassen, R.
  • Guillon, O.
  • Escolástico Rozalén, Sonia|||0000-0002-7097-2425
  • Serra Alfaro, José Manuel|||0000-0002-1515-1106
[EN] In the context of energy conversion efficiency and decreasing greenhouse gas emissions from power generation and energy-intensive industries, membrane technologies for H-2 extraction and CO2 capture and utilization become pronouncedly important. Mixed protonic-electronic conducting ceramic membranes are hence attractive for the pre-combustion integrated gasification combined cycle, specifically in the water gas shift and H-2 separation process, and also for designing catalytic membrane reactors. This work presents the fabrication, microstructure and functional properties of Lanthanum tungstates (La28-xW4+xO54+delta, LaWO) asymmetric membranes supported on porous ceramic and porous metallic substrates fabricated by means of the sequential tape casting route and plasma spray-physical vapor deposition (PS-PVD). Pure LaWO and W site substituted LaWO were employed as membrane materials due to the promising combination of properties: appreciable mixed protonic-electronic conductivity at intermediate temperatures and reducing atmospheres, good sinterability and noticeable chemical stability under harsh operating conditions. As substrate materials porous LaWO (non-substituted), MgO and Crofer22APU stainless steel were used to support various LaWO membrane layers. The effect of fabrication parameters and material combinations on the assemblies' microstructure, LaWO phase formation and gas tightness of the functional layers was explored along with the related fabrication challenges for shaping LaWO layers with sufficient quality for further practical application. The two different fabrication strategies used in the present work allow for preparing all-ceramic and ceramic-metallic assemblies with LaWO membrane layers with thicknesses between 25 and 60 mu m and H-2 flux of ca. 0.4 ml/min cm(2) measured at 825 degrees C in 50 vol% H-2 in He dry feed and humid Ar sweep configuration. Such a performance is an exceptional achievement for the LaWO based H-2 separation membranes and it is well comparable with the H-2 flux reported for other newly developed dual phase cer-cer and cer-met membranes., ProtOMem Project under the BMBF grant 03SF0537 is gratefully acknowledged. Furthermore, the authors thank Ralf Laufs for his assistance in operating the PS-PVD facility. Dr. A. Schwedt from the Central Facility for Electron Microscopy (Gemeinschaftslabor fur Elektronenmikroskopie GFE), RWTH Aachen University is acknowledged for performing the EBSD analysis on the PS-PVD samples.
RiuNet. Repositorio Institucional de la Universitat Politécnica de Valéncia
Publicación Artículo científico (JournalArticle)

About the stability of self-accelerating parameters in vectorial iterative methods without memory

  • Cordero Barbero, Alicia|||0000-0002-7462-9173
  • Torregrosa Sánchez, Juan Ramón|||0000-0002-9893-0761
  • Maimó, Javier G.
  • Rodriguez Cabral, Antmel
[EN] This study is motivated by the need to improve the efficiency of iterative methods for solving nonlinear systems, overcoming some limitations of Newton's method and other classical schemes. Building on the recent work of Singh, Sharma, and Kumar-which introduced a self-accelerating parameter dependent on the last iterate-an in-depth stability analysis of these without memory methods in a vectorial framework is proposed. The main objective is to evaluate how parameters' selection and variation affect the process's convergence and stability using tools from discrete dynamical systems, bifurcation diagrams, and dynamical planes. The results demonstrate that certain members of the family, particularly those with fourth-order convergence, exhibit superior stability properties compared to the initially proposed fifth-order scheme. Additionally, numerical tests on various nonlinear systems confirm the theoretical stability results. The stable methods of these families can be successfully applied on realistic problems such as preliminary orbit determination and on the nonlinear systems resulting from the discretization of Fisher's equation used in population genetics and ecology, convection-diffusion equations appearing in engineering problems, etc., The author(s) disclosed receipt of the following financial support for the research, authorship, and/or publication of this article: This research was financed by Fondo Nacional de Innovacion y Desarrollo Cientifico y Tecnologico (FONDOCYT) of Ministerio de Educacion Superior Ciencia y Tecnologia de la Republica Dominicana (MESCYT), grant number FONDOCYT 2023-1-1D2-0537.
RiuNet. Repositorio Institucional de la Universitat Politécnica de Valéncia
Publicación Artículo científico (JournalArticle)

High-level convergence order accelerators of iterative methods for nonlinear problems

  • Cordero Barbero, Alicia|||0000-0002-7462-9173
  • Torregrosa Sánchez, Juan Ramón|||0000-0002-9893-0761
  • Rojas-Hiciano, Renso V.
  • Vassileva, María P.
[EN] We present an efficient strategy to increase, under certain conditions, the order of convergence of iterative methods to solve nonlinear systems of equations. We analytically compare the new accelerator with others and establish the conditions under which this technique is more efficient. We perform an analysis of the efficiency of some one-step accelerators that increase the convergence order by two units. New concepts about efficiency are introduced which allow us to compare different iterative schemes from other points of view. We demonstrate that our proposal is a good alternative to the existing ones. As a consequence, we propose two new maximally efficient, damped Newton-Traub type schemes of order 5 and 6. These are an improvement of two other maximally efficient methods. Their numerical performance is better than that of known methods of the same order, and we find that it is a very economical way to achieve high order. Some numerical examples confirm the theoretical results., This research was partially financed by Fondo Nacional de Innovacion y Desarrollo Cientifico y Tecnologico (FONDOCYT) of Ministerio de Educacion Superior Ciencia y Tecnologia de la Republica Dominicana (MESCYT) grant number FONDOCYT 2023-1-1D2-0537.
RiuNet. Repositorio Institucional de la Universitat Politécnica de Valéncia
Publicación Artículo científico (JournalArticle)

Efficiency and Stability of a New Hybrid Unconstrained Optimization Algorithm with Quasi-Newton Updates and Higher-Order Methods

  • Cordero Barbero, Alicia|||0000-0002-7462-9173
  • Torregrosa Sánchez, Juan Ramón|||0000-0002-9893-0761
  • Maimo, Javier G.
  • Ureña Castillo, Natanael
[EN] We propose the higher-order quasi-Newton (HOQN) method, a hybrid algorithm for unconstrained optimization that combines Newtonian predictors with higher-order correctors derived from vector extensions of the Traub, Chun, and Ostrowski methods, along with quasi-Newton updates of the inverse Hessian using Broyden-Fletcher-Goldfarb-Shanno (BFGS) or Davidon-Fletcher-Powell (DFP) formulas. We demonstrate that the resulting scheme achieves cubic local convergence order, representing a substantial improvement over the superlinear convergence typical of classical quasi-Newton methods, while maintaining a cost of On2 per iteration. We also analyze variants that incorporate two successive quasi-Newton updates, and show that they retain the same cubic order. Numerical experiments with the benchmark functions of Himmelblau and Freudenstein-Roth confirm the theoretical convergence order and show that the hybrid variants consistently require fewer iterations than BFGS, DFP, and Symmetric Rank-One (SR1). In the case of the Booth function, given its strictly convex quadratic structure, the proposed hybrid methods reach the global minimum in just two iterations and exhibit numerical accuracy superior to that of classical quasi-Newton methods. In addition, limited-memory variants (L-HOQN) are introduced; these are evaluated during the training of a convolutional neural network on the MNIST dataset, where they achieve test accuracies exceeding 99% and outperform L-BFGS and standard stochastic gradient descent (SGD) at all tested learning rates., This research was funded by the Fondo Nacional de Innovacion y Desarrollo Cientifico y Tecnologico (FONDOCYT) of the Ministerio de Educacion Superior, Ciencia y Tecnologia de la Republica Dominicana (MESCyT), under grant number FONDOCYT 2023-1-1D2-0537.
Academica-e. Repositorio Institucional de la Universidad Pública de Navarra
Publicación Artículo científico (JournalArticle)

A deep learning image analysis method for renal perfusion estimation in pseudo-continuous arterial spin labelling MRI

  • Oyarzun Domeño, Anne
  • Cia Alonso, Izaskun
  • Echeverría Chasco, Rebeca
  • Fernández Seara, María Asunción
  • Martín Moreno, Paloma L.
  • Bastarrika, Gorka
  • Navallas Irujo, Javier
  • Villanueva Larre, Arantxa
Accurate segmentation of renal tissues is an essential step for renal perfusion estimation and postoperative assessment of the allograft. Images are usually manually labeled, which is tedious and prone to human error. We present an image analysis method for the automatic estimation of renal perfusion based on perfusion magnetic resonance imaging. Specifically, non-contrasted pseudo-continuous arterial spin labeling (PCASL) images are used for kidney transplant evaluation and perfusion estimation, as a biomarker of the status of the allograft. The proposed method uses machine/deep learning tools for the segmentation and classification of renal cortical and medullary tissues and automates the estimation of perfusion values. Data from 16 transplant patients has been used for the experiments. The automatic analysis of differentiated tissues within the kidney, such as cortex and medulla, is performed by employing the time-intensity-curves of non-contrasted T1-weighted MRI series. Specifically, using the Dice similarity coefficient as a figure of merit, results above 93%, 92% and 82% are obtained for whole kidney, cortex, and medulla, respectively. Besides, estimated cortical and medullary perfusion values are considered to be within the acceptable ranges within clinical practice., Project PC181-182 RM-RENAL, supported by the Department of University, Innovation and Digital Transformation (Government of Navarre). The author would also like to acknowledge the Department of University, Innovation and Digital Transformation (Government of Navarre) for the predoctoral grant number 0011-0537-2021-000050. Open access funding provided by Universidad Pública de Navarra.
Academica-e. Repositorio Institucional de la Universidad Pública de Navarra
Publicación Artículo científico (JournalArticle)

Spring with adjustable elastic constant: application to vibration damping of an engine

  • García Vidaurreta, Carlos
  • Pérez Ezcurdia, Amaya
  • Latorre Biel, Juan Ignacio
  • Benito Amurrio, Marta
  • Alfaro López, José Ramón
Planar disk springs have been widely used in recent decades due to their compact geometry, long service life, and low cost. They require no maintenance or lubrication, making them highly efficient components for a variety of applications. In this work, a device was designed and characterized to regulate the elastic constant of a disk spring by varying the effective length of its flexure arms. Its mechanical behavior was simulated using the finite element method and experimentally validated using a tensile testing machine. The ability to vary the effective length of the device’s flexure arms enables adequate performance under varying operating conditions without the need to replace the spring. The proposed device covers a broad range of elastic constants (k) and has been successfully tested as a vibration damper in an engine operating under variable loads. Real-time adjustment of this constant allows for dynamic control of the ratio between the excitation frequency and the system’s natural frequency. Since the elastic constant k is a key variable in determining the resonant frequency, modifying it makes it possible to influence the system’s vibration modes. This capability facilitates the achievement of optimal damping conditions, which are essential for ensuring system stability and preventing structural damage. In addition, two different types of disks were used in the experimental setup, depending on the weight distribution at each support point of the system., This work was supported by the Public University of Navarre under the Promotion Plant of Research Groups 2025 and by the Government of Navarre (Department of University, Innovation, and Digital Transformation) under predoctoral grant 0011-0537-2024-000062.
Academica-e. Repositorio Institucional de la Universidad Pública de Navarra
Publicación Artículo científico (JournalArticle)

Advancing ASL kidney image registration: a tailored pipeline with VoxelMorph

  • Oyarzun Domeño, Anne
  • Cia Alonso, Izaskun
  • Echeverría Chasco, Rebeca
  • Fernández Seara, María Asunción
  • Martín Moreno, Paloma L.
  • García Fernández, Nuria
  • Bastarrika, Gorka
  • Navallas Irujo, Javier
  • Villanueva Larre, Arantxa
In clinical renal assessment, image registration plays a pivotal role, as patient movement during data acquisition can significantly impede image post-processing and the accurate estimation of hemodynamic parameters. This study introduces a deep learning-based image registration framework specifically for arterial spin labeling (ASL) imaging. ASL is a magnetic resonance imaging technique that modifies the longitudinal magnetization of blood perfusing the kidney using a series of radiofrequency pulses combined with slice-selective gradients. After tagging the arterial blood, label images are captured following a delay, allowing the tagged blood bolus to enter the renal tissue, while control images are acquired without tagging the arterial spins. Given that perfusion maps are generated at the pixel level by subtracting control images from label images and considering the relatively small signal intensity difference, precise alignment of these images is crucial to minimize motion artefacts and prevent significant errors in perfusion calculations. Moreover, due to the extended ASL acquisition times and the anatomical location of the kidneys, renal images are often susceptible to pulsation, peristalsis, and breathing motion. These motion-induced noises and other instabilities can adversely affect ASL imaging outcomes, making image registration essential. However, research on renal MRI registration, particularly with respect to learning-based techniques, remains limited, with even less focus on renal ASL. Our study proposes a learning-based image registration approach that builds upon VoxelMorph and introduces groupwise inference as a key enhancement. The dataset includes 2448 images of transplanted kidneys (TK) and 2456 images of healthy kidneys (HK). We compared the automatic image registration results with the widely recognized optimization method Elastix. The model’s performance was evaluated using the mean structural similarity index (MSSIM), normalized correlation coefficient (NCC), temporal signal-tonoise ratio (TSNR) of the samples, and the mean cortical signal (CSIM) in perfusion-weighted images, thereby extending the evaluation beyond traditional similarity-based metrics. Our method achieved superior image registration performance, with peak NCC (0.987 ± 0.006) and MSSIM (0.869 ± 0.048) values in the kidney region, significantly surpassing Elastix and the unregistered series (p\ 0.05) on TK and HK datasets. Regularization analysis showed that higher k values (1, 2) produced smoother deformation fields, while moderate k values (0.5, 0.9) balanced smoothness and detail, maintaining low non-positive Jacobian percentages (\1%) comparable to Elastix. Additionally, our method improved CSIM by 14.3% (2.304 ± 1.167) and TSNR by 13.1% (3.888 ± 2.170) in TK, and achieved up to 13.2% (CSIM) and 29.8% (TSNR) enhancements in HK, demonstrating robustness and improved signal quality across datasets and acquisition techniques., Open access funding provided by Universidad Pública de Navarra. Project PC181-182 RM-RENAL, supported by the Department of University, Innovation and Digital Transformation (Government of Navarre). The author receives a PhD scholarship number 0011-0537-2021-000050 from Department of University, Innovation and Digital Transformation (Government of Navarre).
Academica-e. Repositorio Institucional de la Universidad Pública de Navarra
Publicación Artículo científico (JournalArticle)

Automatic detection of motor unit fractions in multiscanning EMG recordings

  • Kallingal Muraleedharan, Mahima
  • Mariscal Aguilar, Cristina
  • Rodríguez Falces, Javier
  • Navallas Irujo, Javier
  • Malanda Trigueros, Armando
Purpose This study presents a novel algorithm for the automatic detection of motor unit (MU) fractions within the motor unit potential (MUP) scans derived from multiscanning EMG recordings. MU fractions are spatially distinct regions identif ied in the MUP scans that reflect the distribution of muscle fibres within each MU. Multiscanning EMG allows recording multiple MUPs simultaneously in a single recording, improving efficiency and reducing patient discomfort. Methods The algorithm combines amplitude thresholding, morphological operations, and connected component analysis to identify MU fractions. Algorithm performance was evaluated using MUP scans from tibialis anterior muscles of five healthy individuals. The analysis was performed in two ways: the first included all the fractions detected automatically, and the second included only those fractions detected in both the automatic and the ground truth. Additionally, the association between muscle depth, number of MU fractions, and signal-to-noise ratio (SNR) of the recorded signals was analysed. Results T-tests showed no statistically significant difference between the algorithm and ground truth for both start and end markers. ANOVA indicated that muscle depth did not affect the signal-to-noise ratio (f = 1.06, p = 0.35). Overall, the algorithm reliably identified MU fractions. Conclusion The proposed automatic method accurately detects MU fractions, providing a valuable tool for analysing motor unit activity in clinical and research settings., This work was supported by the predoctoral grant from the Department of Universities, Innovation and Digital Transformation, Govt. of Navarra (Grant number: 0011-0537-2021-000059). This work was also supported by the Ministerio de Ciencia e Innovacion, Spanish Government (Grant number: PID2019-109062RB-100, PID2022-1366200B-100). Ministerio de Ciencia e Innovación, PID2019-109062RB-100, Javier Navallas, Spanish National Plan for Scientific and Technical Research and Innovation, PID2022-136620OB-I00, Javier Navallas, Departamento de Universidad, Innovación y Transformación Digital - Gobierno de Navarra., 0011-0537-2021-000059, Mahima Kallingal Muraleedharan.
Academica-e. Repositorio Institucional de la Universidad Pública de Navarra
Publicación Tesis doctoral (DoctoralThesis)

Development of α’-hydroxy enones as Michael acceptors for organocatalytic enantioselective conjugate addition of aldehydes and α-branched nitroalkanes

  • Lorea Revilla, Beñat
The development of catalyst-controlled enantioselective conjugate addition methods has experienced spectacular progress nowadays, in part due to implementation of organocatalytic activation strategies, both covalent and non-covalent. Despite huge advances in the field, state of the art methods still present limitations and as such cannot address every single synthetic challenge. For example, while nitroalkenes have been widely used as Michael acceptors in a wide variety of organocatalytic enantioselective conjugate additions, other acceptors such as α,β- unsaturated carbonyl compounds have been less commonly used, probably due to their lower reactivity. Among them, simple acrylates in general lack reactivity in the addition of nucleophiles, making it necessary to prepare and use more reactive acrylates or to employ more elaborate catalysts that lead to a greater activation of this acceptor. On the other hand, the Michael addition involving nitro-containing compounds as donors has been widely explored due to the versatility of the nitro group, which can be afterwards transformed into numerous functionalities. However, the asymmetric Michael addition of α-branched nitroalkanes is still a challenging reaction because this substitution generates steric hindrance that obstructs both deprotonation and the approach to the acceptor. Furthermore, a new quaternary stereocenter is formed in the reaction, which makes the stereocontrol more challenging. Moreover, in the few examples of additions of asymmetric α-branched nitroalkanes to enones reported, the nitroalkanes bear an electron-ithdrawing group at the alpha position. Presumably, the higher acidity of this kind of nitro compounds and their aptitude for catalyst two-point binding are critical for success. We hypothesized that purposely designing α’-hydroxy enones acting as acrylate surrogates may serve to solve some of the above limitations owing to their reactivity and coordinating ability, as it has been previously disclosed by our laboratory. Thus, several α’-hydroxy enones bearing different substituents at Cα’ were prepared and tested in the Michael reactions of aldehydes and α-branched nitroalkanes. In this Doctoral Thesis we have demonstrated that in contrast to simple enones, which usually require additional activation by an external H-bond donor additive or cocatalyst, α’-hydroxy enones react with enolizable aldehydes in the presence of commercially available diphenylprolinol ether catalysts (C1 or C3) as the only promoters affording adducts bearing a tertiary stereocenter, in good yields (up to 82%) and high enantioselectivity (up to 97:3 er) (Scheme 1). Ulterior transformation of adducts into carboxylic acids, ketones and aldehyde building blocks, was also carried out. Additionally, in this study we show the Michael-type enantioselective organocatalytic addition of several asymmetric α-methyl nitroalkanes to different α’-hydroxy enones using N,Ndiacylaminals (developed by our groups and successfully used in various carbon-carbon bond formation reactions) as Brønsted base/hydrogen bond catalysts (Scheme 2). α’-Hydroxy enone bearing geminal 3,5-bis(trifluoromethyl)phenyl groups showed the greatest reactivity with several α-methyl nitroalkanes at 0 °C in presence of C17 (20 mol%), achieving the products in good yield (up to 82%) and high enantiomeric ratio (up to 96:4). The elaboration of adducts into carboxylic acid, ketone, aldehyde and nitrile functionalities was also successfully assessed., Concesión de una beca predoctoral del Gobierno de Navarra (expediente 0011-0537-2019-000009)., Programa de Doctorado en Química Sintética e Industrial (RD 99/2011), Kimika Sintetiko eta Industrialeko Doktoretza Programa (ED 99/2011)
Academica-e. Repositorio Institucional de la Universidad Pública de Navarra
Publicación Artículo científico (JournalArticle)

Integrated optoelectronic refractometer based on ZnO photodetector with EHD-printed electrodes and PDMS waveguide

  • Villena Salgado, Hiyary
  • Herrera Urrutia, Jakes
  • Matías Maestro, Ignacio
  • Corres Sanz, Jesús María
This letter reports the development of an integrated optoelectronic sensor for refractive index (RI) measurement, based on a zinc oxide metal–semiconductor–metal photodetector with electrohydrodynamic (EHD)-printed interdigitated electrodes and a polydimethylsiloxane (PDMS) waveguide placed on the sensor surface. The sensor detects variations in photocurrent caused by changes in the evanescent field of the PDMS waveguide when an analyte is deposited on it. A higher analyte RI results in decreased photocurrent. This work reports a promising application of conventional ultraviolet photodetectors for RI sensing. The use of scalable techniques, such as EHD printing and sputtering, together with direct integration of the PDMS waveguide, highlights the potential of the device as a compact and versatile sensing platform., This work was supported in part by the Gobierno de Navarra under Grant PC24-DEPLOC-012-002-015 and in part by the Gobierno de Navarra under Ayudas predoctorales para la realización de Programas de Doctorado de Interés para Navarra under Grant 0011-0537-2024-000070. Open access funding provided by the Public University of Navarra.
Academica-e. Repositorio Institucional de la Universidad Pública de Navarra
Publicación Artículo científico (JournalArticle)

Establishment and characterization of an orthotopic implanted lung cancer model to mimic human tumor structure, microenvironment, and metastatic spread

  • Picabea, Beñat
  • Orive, Daniel
  • Rodríguez, Covadonga
  • Mailharin, Miren
  • Sangüesa Recalde, María
  • Houry, Maeva
  • Arricibita, Andrea
  • Echepare, Mirari
  • Álava, Ane
  • Viu-Idocin, Cristina
  • Calvo, Alfonso
  • Fernández Irigoyen, Joaquín
  • Santamaría Martínez, Enrique
  • Ariz Galilea, Mikel
  • Montuenga, Luis M.
  • Valencia, Karmele
Background: Subcutaneous (SC) lung tumor models are widely used in preclinical studies due to their technical simplicity but fail to recapitulate the complex microenvironment, immune landscape, and metastatic behavior of human lung cancers. These limitations hinder the translational value of such models, particularly in evaluating immunotherapies and metastasis-related mechanisms. There is a critical need for more physiologically relevant in vivo models that better reflect clinical tumor characteristics and disease progression. To address these limitations, we sought to develop a reproducible orthotopic lung cancer (LuO) model that enables detailed study of tumor progression, immune infiltration, and metastatic dynamics. Methods: we established and characterized a thoracotomy-based LuO model using a panel of human and murine lung cancer cell lines implanted into the pulmonary parenchyma of immunodeficient and syngeneic mice. Tumor progression was monitored longitudinally using bioluminescence imaging (BLI) and micro-computed tomography (CT). Comparative analyses with SC tumors were performed using immunohistochemistry, multiplexed immunofluorescence, transcriptomic and proteomic analyses. Circulating tumor cells (CTCs) and spontaneous metastases were isolated and functionally characterized. Results: the orthotopic model reliably generated solitary intrapulmonary tumors that closely mimic human lung cancer in growth pattern, vascularization, and progression. Compared to SC tumors, orthotopic tumors exhibited significantly enhanced vascular density, reduced hypoxia and DNA damage, and increased proliferation. Immune profiling revealed enriched and spatially organized infiltrates of CD4+ , CD8+ T cells, dendritic cells (DCs), and myeloid populations in orthotopic tumors, forming structures analogous to those found in patient tumors. Moreover, orthotopic tumors released CTCs capable of forming spontaneous and site-specific metastases to clinically relevant organs. Transcriptomic and proteomic profiling of metastasisderived cell lines uncovered conserved pro-metastatic signatures and niche-specific adaptations. Conclusions: this LuO model offers a reproducible, clinically relevant platform that captures important aspects of human lung cancer biology, including immune landscape, tumor microenvironment (TME), and metastatic progression. Its superior anatomical and immunological fidelity makes it a valuable preclinical tool for evaluating therapeutic strategies and dissecting molecular mechanisms of metastasis., This work was supported by Fundación para la Investigación Médica Aplicada (FIMA), Centro de Investigación Médica en Red de Cáncer (CIBERONC) (CB16/12/00443), Fundación La Caixa, Instituto de Salud Carlos III-Fondo de Investigación Sanitaria (FIS) program (PI22/00451 to L.M.M.), Spanish Ministry of Economy and Innovation and Fondo de Investigación Sanitaria-Fondo Europeo de Desarrollo Regional (PI23/00223 to K.V.), European Union Mission Cancer Program. SPACETIME, HORIZON-MISS-2023-CANCER-01 to L.M.M.
DIGITAL.CSIC. Repositorio Institucional del CSIC
Publicación Artículo científico (JournalArticle)

Improving the accuracy of Kováts' retention indices in isothermal gas chromatography

  • Lebrón-Aguilar, Rosa
  • Quintanilla-López, Jesús Eduardo
  • García-Domínguez, José Antonio
10 pages, 6 tables, Isothermal Kováts' retention indices are currently reported as whole numbers, and are frequently deduced from a linear least mean squares fitting of the logarithms of adjusted retention times of a number of n-alkanes versus carbon number, following an iterative method that minimises errors. The currently accepted accuracy is about one retention index unit for apolar stationary phases, and lower for polar stationary phases. This paper presents results that show how the accuracy of the retention index may be safely reported to one-tenth of a retention index unit by the use of a non-linear equation, with present day gas chromatographs without electronic flow controllers. Results are presented that prove the correctness of the retention indices found for several substances on one particular capillary column. Hints on the minimum retention times needed to achieve the 0.1 retention index accuracy are mentioned, for retention times recorded in minutes and in seconds. According to results of this paper, two chromatograms, run under the appropriate conditions, are sufficient to obtain the desired accuracy. The method proposed in this paper does not require knowledge of the hold-up time of the chromatogram., The work presented in this paper has been carried out under projects PB97-1214 and PB98-0537-C02´ 01 of the Comision Interministerial de Ciencia y ´ Tecnologıa (CICYT) of Spain. The authors would ´ like to express their gratitude to Asuncion de Diago for her help with some of the experiments and numerical calculations., Peer reviewed
DIGITAL.CSIC. Repositorio Institucional del CSIC
Publicación Artículo científico (JournalArticle)

An accurate and easy procedure to obtain isothermal Kováts retention indices in gas chromatography

  • García-Domínguez, José Antonio
  • Lebrón-Aguilar, Rosa
  • Quintanilla-López, Jesús Eduardo
8 pages, 6 tables, Isothermal Kováts retention indices may be used in GC for identification purposes, but they are also useful in characterisation of stationary phases and for studying structural and physico-chemical properties of both the analyte and the stationary phase. They are currently reported as whole numbers with an accuracy of one index unit for non-polar stationary phases. The method recommended for their calculation uses a linear regression model, although non-linear models have also been applied with good results. In both cases, a computer programme and the retention times of a series of n-alkanes that elute correctly and resolved from the other compounds are needed, conditions which cannot always be fulfilled. However, it is possible to calculate retention indices with an accuracy of 0.1 retention index units (0.2 units for packed columns) with the help of only three n-alkanes using just a pocket calculator or a computer spreadsheet. The main requirement is that at least one of the n-alkanes has a retention index differing by no more than one hundred retention index units from that of the analyte being investigated. Examples are given for different stationary phases., The results presented in this paper have been obtained and elabo-rated under the Projects PB98-0537-C02 and BQU2002-03381 ofthe Dirección General de Investigación of Spain. The authors wishto express their thanks to M. A. de Diago for her help in some ofthe numerical calculations., Peer reviewed