- Lopez Paz, Ivan
- Godignon, Philippe
- Moffat, Neil
- Pellegrini, Giulio
- Rafí, Joan Marc
- Rius, Gemma
Silicon carbide (SiC) has outstanding physical properties therefore, diodes based on SiC are being considered for many radiation detection applications such as particle accelerator experiments and medical dosimetry. Moreover, by reducing the metal on the surface of the diode there is the potential to enhance its performance in some fields where the presence of metal is detrimental. To this end, SiC detectors with an epitaxially-grown graphene layer (EG), that substitutes the metallic contact, in the sensitive region were produced at IMB-CNM, profiting from the conductivity of the mono-atomic layer material. To isolate the effect of the graphene on the charge collection, samples without graphene were produced in parallel. In this paper, the effect of EG on Silicon Carbide p-in-n radiation detectors is studied in terms of charge collection with a radioactive source and by means of the transient current technique (TCT), which allows for position-dependent signal formation analysis. As a result of the former, we show the capability of the EG-SiC sensor for charge collection after signal integration, to a resolution close to that of a sensor fully metallised. Moreover, from the TCT studies, we observe uniform charge collection across the active region, as well as an up-to ∼40% transient amplitude damping which, compared with the ∼90% on the sample containing no metallic contact, proves that the presence of graphene benefits the performance of the device and that the technology is viable for radiation detection as an alternative to metal. © The Author(s) 2024., This work has been funded by the Spanish Ministry of Science and Innovation (MCIN/AEI/10.13039/501100011033/) and by the European Union\u2019s ERDF program \u201CA way of making Europe\u201D.Grant references: PID2021-124660OB-C22 and by the European Union\u2019s Horizon 2020 Research and Innovation funding program, under Grant Agreement No. 101004761 (AIDAInnova). Support from Ayudas Ramon y Cajal Ref. RYC-2016-21412 is also acknowledged., The transient signals obtained under the triple-alpha radioactive source set-up are shown in Fig. 5. The waveforms obtained from all samples showcase a dip after the main transient pulse attributed to an impedance mismatch, causing a reflection. The integration window in Sample-1M was chosen before this undershoot, since the pulses from charge collection are faster. However, as the signals are longer in the other samples, the integration window for the charge determination is chosen longer, which in turn results in an under-estimation of the charge collection. Amplitude distribution for all samples under a bias voltage of -500 V are shown in Fig. 6 (left). Notably, Sample-1 has an overall lower amplitude distribution, although Sample-1M is the only detector showcasing the three peaks expected from the three alpha particle energies from the radioactive source. However - after integration - the same features appear in Sample-1G, as shown in Fig. 6 (right). As it will be observed in the following sections in more detail, the apparent charge collection loss in Sample-1 is a result of the higher resistance observed by the transient signal before reaching the bias ring with respect to the other samples, which reduces the waveform amplitudes away from it, to the point where noise is a large contribution in the integration. A 30 ns extra integration window was used in Sample-1 in order to recover charge levels comparable to Samples-1G and -1M. The same damping effect is seen in Sample-1G to a lesser degree., No