Pasar al contenido principal

Resultados relacionados

Resultados totales (Incluyendo duplicados): 4
Encontrada(s) 1 página(s)

RiuNet. Repositorio Institucional de la Universitat Politécnica de Valéncia
Publicación Artículo científico (JournalArticle)

Mechanical, structural, and biological evaluation of multilayer HA-Ag/ TiO2/TiN/Ti coatings on Ti6Al4V obtained by magnetron sputtering for implant applications

  • Lenis, J.A.
  • Contreras Romero, Elbert
  • Hurtado Macías, Abel
  • Pacha-Olivenza, M.A.
  • González-Martín, M.L.
  • Bolívar, F.J.
  • Rico Tortosa, Patricia María
  • Gómez Ribelles, José Luís|||0000-0001-9099-0885
[EN] In the present work the surface of Ti6Al4V alloy, widely used for the fabrication of implants, was modified by incorporating a novel biocompatible and antibacterial coating composed of multiple layers of hydroxyapatite (HA) and Ag deposited on a TiO2/TiN/Ti trilayer. During the characterization of the coatings, their chemical and phase compositions were evaluated by energy dispersive X-ray spectroscopy and X-ray diffraction. Structural, topographical, and morphological studies were performed by focused ion beam, field emission scanning electron microscopy, transmission electron microscopy and atomic force microscopy. Mechanical properties were determined by nano indentation and micro scratch test. Finally, the in vitro biological response was evaluated by cell viability tests with mouse mesenchymal stem cells, while bacterial viability was evaluated with Staphylo-coccus aureus strain. The results obtained show great chemical and compositional control, identifying HA (Ca/P close to 1.67) and anatase phases for TiO2. Additionally, an architecture composed of nanometric layers forming a HA-Ag/TiO2/TiN/Ti coating with granular morphology was obtained. The incorporation of multiple Ag layers in the HA structure led to a decrease of about 44 % in its hardness, obtaining values of up to 6.3 GPa. Meanwhile, there was a relief in the residual stresses of >50 %, which generated increases of up to 74 % in the adhesion of the coatings to the substrate The biological tests showed that biocompatible coatings with high antibacterial potential were obtained., We thank the University of Antioquia, the Centro de Investigacion, Innovacion y Desarrollo de materiales (CIDEMAT) group, the Departamento Administrativo de Ciencia, Tecnologia e Innovacion (COLCIENCIAS) for financing the Project 15-1696, the scholarship program of Enlazamundos, the Agencia de Educacion Superior de Medellin (Sapiencia). The experimental work performed at the CBIT was funded by the Spanish State Research Agency (AEI) through the PID2019-106099RBC41/AEI/10.13039/501100011033 and RTI2018-096794-B-I00 projects. CIBER-BBN is an initiative funded by the VI National R&D&I Plan 2008-2011, Iniciativa Ingenio 2010, Consolider Program. CIBER Actions were financed by the Instituto de Salud Carlos III with assistance from the European Regional Development Fund. The Microscopy Service of the UPV (Universitat Politècnica de València) is gratefully acknowledged. The authors are grateful to Junta de Extremadura and FEDER for grants GR18153 and IB20092. The project RTI2018-096862B-I00, supported by MCIN/AEI/10.13039/501100011033/and by FEDER "Una manera de hacer Europa", is also highly appreciated.
RiuNet. Repositorio Institucional de la Universitat Politécnica de Valéncia
Publicación Artículo científico (JournalArticle)

Determination of synergistic effect between roughness and surface chemistry on cell adhesion of a multilayer Si- Hydroxyapatite coating on Ti6Al4V obtained by magnetron sputtering

  • Pérez Zapata, K.
  • Lenis, J.A.
  • Bolívar, F.J.
  • Rico Tortosa, Patricia María
  • Gómez Ribelles, José Luís|||0000-0001-9099-0885
[EN] Ti alloys are widely used in the biomedical field because they have an adequate balance between mechanical properties, corrosion resistance and biocompatibility. However, when this material is incorporated in the human body, unfavorable reactions can be obtained which do not allow a good osseointegration due to the formation of a fibrous and non-adherent layer between the biomaterial and the bone, which can lead to failure or rejection of the implant. In this study, the influence of surface modification of Ti6Al4V alloy with a hydroxyapatite (HA) and silicon (Si) coating on its biological response in vitro was evaluated. The deposition process was performed by sputtering on two Ti6Al4V surfaces with different root mean square roughness values, the first one with 3.8 nm and the second one with 48.7 nm. The surface morphology of the coatings was observed by Scanning Electron Microscopy and Atomic Force Microscopy, the chemical composition was evaluated by X-ray Energy Dispersive Spectrometry and micro-Raman Spectroscopy. The in vitro biological response of the coatings was evaluated by cell metabolic activity assay and cell adhesion tests, using mouse mesenchymal stem cells. The control of the process parameters allowed obtaining a multilayer HA-Si coating with good compositional balance (Ca/P ratio very close to 1.67 and characteristic vibrations of the HA phase). Roughness values of 27 +/- 5 nm and 52 +/- 6 nm were obtained for the multilayer coatings obtained on Ti6Al4V (smooth surface) and Ti6Al4V (rough surface), respectively. Biological assays indicated a potentially non-toxic character of the coatings, moreover, the cell adhesion of Ti6Al4V was favored both by the incorporation of the HA-Si multilayer coating and by the increase in the roughness of the substrate., We thank the University of Antioquia, the Centro de Investigacion, Innovacion y Desarrollo de materiales (CIDEMAT) group, the Departamento Administrativo de Ciencia, Tecnologia e Innovacion (COLCIEN-CIAS) for financing the Project 15-1696, the scholarship program of Enlazamundos, the Agencia de Educacion Superior de Medellin (Sapiencia), JLGR acknowledges financial support from the Spanish Ministry of Economy and Competitiveness (MINECO) through the project MAT2016-76039-C4-1-R and MAT 2015-63974-C4-3-R (AEI/FEDER, UE) (including the FEDER financial support). PR acknowledges support from the Spanish Ministry of Science, Innovation and Universities (RTI2018-096794), and Fondo Europeo de Desarrollo Regional (FEDER). CIBER-BBN is an initiative funded by the VI National R & D & I Plan 2008-2011, Iniciativa Ingenio 2010, Consolider Program. CIBER Actions are financed by the Instituto de Salud Carlos III with assistance from the European
RiuNet. Repositorio Institucional de la Universitat Politécnica de Valéncia
Publicación Artículo científico (JournalArticle)

Structure, morphology, adhesion and in vitro biological evaluation of antibacterial multi-layer HA-Ag/SiO2/TiN/Ti coatings obtained by RF magnetron sputtering for biomedical applications

  • Lenis, J. A.
  • Pacha-Olivenza, M. A.
  • González-Martín, M. L.
  • Bolívar, F. J.
  • Rico Tortosa, Patricia María
  • Gómez Ribelles, José Luís|||0000-0001-9099-0885
[EN] Biocompatible and antibacterial multi-layer coatings of hydroxyapatite (HA)-Ag/SiO2/TiN/Ti were obtained on the Ti-6Al-4V alloy, by means of the magnetron sputtering technique. During characterization of the coatings, the chemical composition was evaluated by energy dispersive X-ray spectroscopy and the phase analysis was carried out by X-ray diffraction. The morphology of the coatings was observed by field emission scanning electron microscopy, while transmission electron microscopy was used to appreciate their structure. The adhesion of the coatings to the substrate was evaluated by micro scratch test. The in vitro biological response was evaluated in terms of cytotoxicity, adhesion and differentiation of mouse mesenchymal stem cells, as well as adhesion and bacterial viability of Staphylococcus aureus strain. Through the compositional study carried out, the deposition of the HA phase was verified, with a Ca/P ratio close to 1.67 and the characteristic diffraction peaks of this compound. The structural study of the coatings evidenced the obtention of multi-layer architectures. The use of an intermediate SiO2/TiN/Ti trilayer was found to improve adhesion between HA-Ag and the substrate by 84%. Finally, the in vitro biological tests carried out indicated a potentially non-toxic character in the coatings. Additionally, an antibacterial effect was registered at low concentrations of Ag (< 0.25 mg/L)., We thank the University of Antioquia, the Centro de Investigacion, Innovacion y Desarrollo de materiales (CIDEMAT) group, the Departamento Administrativo de Ciencia, Tecnologia e Innovacion (COLCIENCIAS) for financing the Project 15-1696, the scholarship program of Enlazamundos, the Agencia de Educacion Superior de Medellin (Sapiencia), JLGR acknowledges financial support from the Spanish Ministry of Economy and Competitiveness (MINECO) through the project MAT2016-76039-C4-1-R and MAT 2015-63974-C4-3-R (AEI/FEDER, UE) (including the FEDER financial support). PR acknowledges support from the Spanish Ministry of Science, Innovation and Universities (RTI2018-096794), and Fondo Europeo de Desarrollo Regional (FEDER). CIBER-BBN is an initiative funded by the VI National R&D&I Plan 2008-2011, Iniciativa Ingenio 2010, Consolider Program. CIBER Actions are financed by the Instituto de Salud Carlos III with assistance from the European Regional Development Fund, M-ERA.NET PCIN-2016-146 and RTI2018-096862-B-I00, Spanish "Junta de Extremadura" for the projects IB16117, TE-0016-18 and GR18153.
RiuNet. Repositorio Institucional de la Universitat Politécnica de Valéncia
Publicación Artículo científico (JournalArticle)

Development of multilayer Hydroxyapatite - Ag/TiN-Ti coatings deposited by radio frequency magnetron sputtering with potential application in the biomedical field

  • Lenis, J.A.
  • Bejarano, G.
  • Bolívar, F.J.
  • Rico Tortosa, Patricia María
  • Gómez Ribelles, José Luís|||0000-0001-9099-0885
[EN] The use of composite coatings is emerging as a great alternative to conventional coatings, allowing the combination of different superficial properties that are widely desired in surgical implants, such as osteointegration and bactericidal character, and cannot be provided by one material alone. In the present investigation the effect of the incorporation of a TiN-Ti intermediate bilayer on the chemical composition, structure, morphology, roughness, residual stresses and adhesion of a multi-layer Hydroxyapatite (HA)-Ag coating deposited on Ti-6Al-4V by magnetron sputtering was evaluated. Additionally, the cytotoxicity of the developed system was evaluated by in vitro tests. According to the results obtained, a decrease in the Ca/P ratio from 1.85 to 1.74 was obtained through the deposition of an HA-Ag system on the intermediate bilayer, and the crystallinity of the developed coating was favored. The multi-layer structure was effectively observed by field emission scanning electron microscopy, where it was possible to identify each of the HA, Ag, TiN and Ti layers. Meanwhile, an increase of 7% in crystallite size, a decrease of 36% in residual stresses and an increase of 32% in adhesion were registered for this composite coating compared to the free intermediate bilayer system. Finally, biological evaluation allowed the non-cytotoxic character of the deposited coatings to be confirmed., We thank the University of Antioquia, the Centro de Investigation, Innovation y Desarrollo de materiales (CIDEMAT) group, the Departamento Administrativo de Ciencia, Tecnologia e Innovation (COLCIENCIAS) for financing the Project 15-1696, the scholarship program of Enlazamundos, PR and JLGR acknowledge financial support from the Spanish Ministry of Economy and Competitiveness (MINECO) through the project MAT2016-76039-C4-1-R (AEI/FEDER, UE) (including the FEDER financial support). CIBER-BBN is an initiative funded by the VI National R&D&I Plan 2008-2011, Iniciativa Ingenio 2010, Consolider Program. CIBER Actions are financed by the Institute de Salud Carlos III with assistance from the European Regional Development Fund.