Pasar al contenido principal

Resultados relacionados

Resultados totales (Incluyendo duplicados): 5
Encontrada(s) 1 página(s)

Dipòsit Digital de Documents de la UAB
Publicación Artículo científico (JournalArticle)

Switchless multiplexing of graphene active sensor arrays for brain mapping

  • Garcia Cortadella, Ramon|||0000-0002-1506-6534
  • Schaefer, Nathan|||0000-0002-2392-3858
  • Cisneros-Fernández, Jose|||0000-0002-5497-7103
  • Ré, Lucia
  • Illa, Xavi|||0000-0002-3212-1128
  • Schwesig, Gerrit
  • Moya Lara, Ana|||0000-0001-6793-9133
  • Santiago Malagon, Sara|||0000-0002-1206-1455
  • Guirado, Gonzalo|||0000-0003-2128-7007
  • Villa, Rosa|||0000-0003-2735-3204
  • Sirota, Anton|||0000-0002-4700-6587
  • Serra Graells, Francesc|||0000-0002-7274-1911
  • Garrido, Jose|||0000-0001-5621-1067
  • Guimerà Brunet, Anton|||0000-0003-1768-3293
Sensor arrays used to detect electrophysiological signals from the brain are paramount in neuroscience. However, the number of sensors that can be interfaced with macroscopic data acquisition systems currently limits their bandwidth. This bottleneck originates in the fact that, typically, sensors are addressed individually, requiring a connection for each of them. Herein, we present the concept of frequency-division multiplexing (FDM) of neural signals by graphene sensors. We demonstrate the high performance of graphene transistors as mixers to perform amplitude modulation (AM) of neural signals in situ, which is used to transmit multiple signals through a shared metal line. This technology eliminates the need for switches, remarkably simplifying the technical complexity of state-of-the-art multiplexed neural probes. Besides, the scalability of FDM graphene neural probes has been thoroughly evaluated and their sensitivity demonstrated in vivo. Using this technology, we envision a new generation of high-count conformal neural probes for high bandwidth brain machine interfaces.
Dipòsit Digital de Documents de la UAB
Publicación Artículo científico (JournalArticle)

Distortion-free sensing of neural activity using graphene transistors

  • Garcia Cortadella, Ramon|||0000-0002-1506-6534
  • Masvidal Codina, Eduard|||0000-0002-9579-8603
  • De la Cruz, Jose|||0000-0001-9656-9653
  • Schaefer, Nathan|||0000-0002-2392-3858
  • Schwesig, Gerrit
  • Jeschke, C.
  • Martínez-Aguilar, Javier
  • Sánchez Vives, María V.|||0000-0002-8437-9083
  • Villa, Rosa|||0000-0003-2735-3204
  • Illa, Xavi|||0000-0002-3212-1128
  • Sirota, Anton|||0000-0002-4700-6587
  • Guimerà Brunet, Anton|||0000-0003-1768-3293
  • Garrido, Jose|||0000-0001-5621-1067
Graphene solution-gated field-effect transistors (g-SGFETs) are promising sensing devices to transduce electrochemical potential signals in an electrolyte bath. However, distortion mechanisms in g-SGFET, which can affect signals of large amplitude or high frequency, have not been evaluated. Here, a detailed characterization and modeling of the harmonic distortion and non-ideal frequency response in g-SGFETs is presented. This accurate description of the input-output relation of the g-SGFETs allows to define the voltage- and frequency-dependent transfer functions, which can be used to correct distortions in the transduced signals. The effect of signal distortion and its subsequent calibration are shown for different types of electrophysiological signals, spanning from large amplitude and low frequency cortical spreading depression events to low amplitude and high frequency action potentials. The thorough description of the distortion mechanisms presented in this article demonstrates that g-SGFETs can be used as distortion-free signal transducers not only for neural sensing, but also for a broader range of applications in which g-SGFET sensors are used.
Dipòsit Digital de Documents de la UAB
Publicación Artículo científico (JournalArticle)

Multiplexed neural sensor array of graphene solution-gated field-effect transistors

  • Schaefer, Nathan|||0000-0002-2392-3858
  • Garcia Cortadella, Ramon|||0000-0002-1506-6534
  • Martínez-Aguilar, Javier
  • Schwesig, Gerrit
  • Illa, Xavi|||0000-0002-3212-1128
  • Moya Lara, Ana|||0000-0001-6793-9133
  • Santiago Malagon, Sara|||0000-0002-1206-1455
  • Hébert, Clément|||0000-0001-9667-033X
  • Guirado, Gonzalo|||0000-0003-2128-7007
  • Villa, Rosa|||0000-0003-2735-3204
  • Sirota, Anton|||0000-0002-4700-6587
  • Guimerà Brunet, Anton|||0000-0003-1768-3293
  • Garrido, Jose|||0000-0001-5621-1067
Electrocorticography (ECoG) is a well-established technique to monitor electrophysiological activity from the surface of the brain and has proved crucial for the current generation of neural prostheses and brain-computer interfaces. However, existing ECoG technologies still fail to provide the resolution necessary to accurately map highly localized activity across large brain areas, due to the rapidly increasing size of connector footprint with sensor count. This work demonstrates the use of a flexible array of graphene solution-gated field-effect transistors (gSGFET), exploring the concept of multiplexed readout using an external switching matrix. This approach does not only allow for an increased sensor count, but due to the use of active sensing devices (i.e. transistors) over microelectrodes it makes additional buffer transistors redundant, which drastically eases the complexity of device fabrication on flexible substrates. The presented results pave the way for upscaling the gSGFET technology towards large-scale, high-density μECoG-arrays, eventually capable of resolving neural activity down to a single neuron level, while simultaneously mapping large brain regions.
Dipòsit Digital de Documents de la UAB
Publicación Artículo científico (JournalArticle)

Improved metal-graphene contacts for low-noise, high-density microtransistor arrays for neural sensing

  • Schaefer, Nathan|||0000-0002-2392-3858
  • Garcia Cortadella, Ramon|||0000-0002-1506-6534
  • Bonaccini Calia, Andrea|||0000-0002-7873-4296
  • Mavredakis, Nikolaos|||0000-0003-3630-9416
  • Illa, Xavi|||0000-0002-3212-1128
  • Masvidal Codina, Eduard|||0000-0002-9579-8603
  • De la Cruz, Jose|||0000-0001-9656-9653
  • Del Corro, Elena|||0000-0001-6452-9139
  • Rodríguez Domínguez, Laura|||0000-0002-6669-1962
  • Prats Alfonso, Elisabet|||0000-0002-7320-1896
  • Bousquet, Jessica|||0000-0001-5721-8092
  • Martínez-Aguilar, Javier
  • Pérez-Marín, Antonio Pablo|||0000-0003-1843-8273
  • Hébert, Clément|||0000-0001-9667-033X
  • Villa, Rosa|||0000-0003-2735-3204
  • Jiménez, David|||0000-0002-8148-198X
  • Guimerà Brunet, Anton|||0000-0003-1768-3293
  • Garrido, Jose|||0000-0001-5621-1067
Poor metal contact interfaces are one of the main limitations preventing unhampered access to the full potential of two-dimensional materials in electronics. Here we present graphene solution-gated field-effect-transistors (gSGFETs) with strongly improved linearity, homogeneity and sensitivity for small sensor sizes, resulting from ultraviolet ozone (UVO) contact treatment. The contribution of channel and contact region to the total device conductivity and flicker noise is explored experimentally and explained with a theoretical model. Finally, in-vitro recordings of flexible microelectrocorticography (μ-ECoG) probes were performed to validate the superior sensitivity of the UVO-treated gSGFET to brain-like activity. These results connote an important step towards the fabrication of high-density gSGFET μ-ECoG arrays with state-of-the-art sensitivity and homogeneity, thus demonstrating the potential of this technology as a versatile platform for the new generation of neural interfaces.
Dipòsit Digital de Documents de la UAB
Publicación Artículo científico (JournalArticle)

Carbon incorporation in MOCVD of MoS2 thin films grown from an organosulfide precursor

  • Schaefer, Christian M.|||0000-0001-7994-2962
  • Caicedo Roque, Jose Manuel|||0000-0002-5192-4989
  • Sauthier, Guillaume|||0000-0003-3566-3878
  • Bousquet, Jessica|||0000-0001-5721-8092
  • Hébert, Clément|||0000-0001-9667-033X
  • Sperling, Justin R.|||0000-0002-1708-2474
  • Perez-Tomas, Amador|||0000-0002-0551-3142
  • Santiso, José|||0000-0003-4274-2101
  • Del Corro, Elena|||0000-0001-6452-9139
  • Garrido, Jose|||0000-0001-5621-1067
With the rise of two-dimensional (2D) transition-metal dichalcogenide (TMD) semiconductors and their prospective use in commercial (opto)electronic applications, it has become key to develop scalable and reliable TMD synthesis methods with well-monitored and controlled levels of impurities. While metal-organic chemical vapor deposition (MOCVD) has emerged as the method of choice for large-scale TMD fabrication, carbon (C) incorporation arising during MOCVD growth of TMDs has been a persistent concern-especially in instances where organic chalcogen precursors are desired as a less hazardous alternative to more toxic chalcogen hydrides. However, the underlying mechanisms of such unintentional C incorporation and the effects on film growth and properties are still elusive. Here, we report on the role of C-containing side products of organosulfur precursor pyrolysis in MoS2 thin films grown from molybdenum hexacarbonyl Mo(CO)6 and diethyl sulfide (CH3CH2)2S (DES). By combining in situ gas-phase monitoring with ex situ microscopy and spectroscopy analyses, we systematically investigate the effect of temperature and Mo(CO)6/DES/H2 gas mixture ratios on film morphology, chemical composition, and stoichiometry. Aiming at high-quality TMD growth that typically requires elevated growth temperatures and high DES/Mo(CO)6 precursor ratios, we observed that temperatures above DES pyrolysis onset (â 600 °C) and excessive DES flow result in the formation of nanographitic carbon, competing with MoS2 growth. We found that by introducing H2 gas to the process, DES pyrolysis is significantly hindered, which reduces carbon incorporation. The C content in the MoS2 films is shown to quench the MoS2 photoluminescence and influence the trion-To-exciton ratio via charge transfer. This finding is fundamental for understanding process-induced C impurity doping in MOCVD-grown 2D semiconductors and might have important implications for the functionality and performance of (opto)electronic devices.