RiuNet. Repositorio Institucional de la Universitat Politécnica de Valéncia
Publicación Artículo científico (JournalArticle)

Validation of an imageless electrocardiographic imaging technique for the non-invasive mapping of regular atrial tachyarrhythmias

  • Reventós-Presmanes, Jana
  • Cano-Cabañero, Andrea
  • Invers-Rubio, Eric
  • Pellicer-Sendra, Berta
  • Serrano-Campaner, Jaume
  • Zacur, Ernesto
  • Althoff, Till F
  • Hernández-Romero, Ismael
  • Borràs, Roger
  • Regany-Closa, Mariona
  • Arbelo, Elena
  • Guasch, Eduard
  • Tolosana, Jose María
  • Porta-Sánchez, Andreu
  • Herrero-Martín, Clara|||0000-0001-5053-296X
  • Andreu M. Climent|||0000-0002-7260-8811
  • Guillem Sánchez, María Salud|||0000-0001-5660-3693
[EN] This study validates the clinical performance of an imageless ECGi system for the characterization of regular atrial tachyarrhythmias. Its ability to provide rapid, full-chamber activation maps from a single beat may make it a potential solution for mapping transient arrhythmias or rhythm changes during ablation procedures., This project has been funded by grants PID2023-149812OB-I00, DIN2024-013365, PTQ2023-013018, PTQ2022-012632, RYC2018-024346-I, CNS2022-135512, and CPP2023-010504 funded by Ministerio de Ciencia, Innovacion y Universidades MCIN/AEI/10.13039/501100011033 and by the European Union NextGenerationEU/Plan de Recuperacion, Transformacion y Resiliencia. This project has been funded by Generalitat Valenciana by grants ACIF/2021/205 and CIAICO/2022/020 and by European Social Fund Investing in Your Future. This project also received funding from European Institute of Innovation and Technology (EIT Health) (activity codes 220385, 230129, and 250027). Additionally, this work was supported by a research grant from Instituto de Salud Carlos III, which is co-funded by the European Union (grant PI22/00441). J.-B.G. acknowledges support from the grants 'Contractes d'Investigacio Avancada Fundacio BBVA' - Hospital Clinic Barcelona Joan Rodes-Josep Baselga 2022' (HCB_BIO_001/2) and the 'Daniel Bravo Andreu Private Foundation 2024 Grants' for short stays abroad in biomedical research.
RiuNet. Repositorio Institucional de la Universitat Politécnica de Valéncia
Publicación Artículo científico (JournalArticle)

Complexity and recurrence of body surface electrocardiograms correlate with estimated reentrant atrial activity using electrocardiographic imaging in atrial fibrillation patients

  • Molero-Alabau, Rubén
  • Meste, Olivier
  • Peeters, Ralf
  • Karel, Joël
  • Bonizzi, Pietro
  • Guillem Sánchez, María Salud|||0000-0001-5660-3693
[EN] Background Complexity and signal recurrence metrics obtained from body surface potential mapping (BSPM) allow quantifying atrial fibrillation (AF) substrate complexity. This study aims to correlate electrocardiographic imaging (ECGI) detected reentrant patterns with BSPM-calculated signal complexity and recurrence metrics. Methods BSPM signals were recorded from 28 AF patients (17 male, 11 women, 62.69 +/- 8.09 y.o.), followed by ECGI calculation. Signal complexity and recurrence metrics were computed on BSPM and ECGI signals. Rotors per second and rotor duration were computed on ECGI signals for each atrium and the whole atrial surface. Correlation between BSPM metrics and ECGI reentrant patterns for the entire atrial surface and for left atrium (LA) and right atrium (RA) were analyzed. Results Atrial complexity and recurrence metrics strongly correlated when computed on BSPM and ECGI. Higher sample entropy and relative harmonic energy (RHE) correlated with rotors of short duration. The highest dominant frequency of the ECGI signals did not correlate with the reentrant activity of the ECGI. Higher short- and long-term recurrence of BSPM signals correlated with longer duration rotors, particularly for long-term recurrence (r(LA)=0.74 vs. r(RA)=0.42). Only ECGI-based reentrant parameters showed higher LA complexity compared to RA (p < 0.05). Conclusions BSPM metrics strongly correlate with metrics measured on ECGI signals. BSPM metrics indicate a more elevated atrial electro-structural remodeling aligned with more short-duration rotors from ECGI computations. Although BSPM delivers qualitative AF reentry data, ECGI remains essential for identifying regional substrate complexity., This work was supported by: Instituto de Salud Carlos III (supported by FEDER Fondo Europeo de Desarrollo Regional PI17/01106), Generalitat Valenciana and European Social Fund (ACIF/2020/265, BEFPI/2021/062, CIAICO/2022/020), Agencia Estatal de Investigacion PID2020-119364RB-I00, PID2023-149812OB-I00 and CPP2021-008562 by "European Union NextGenerationEU/PRTR". This research has received funding from the European Institute of Innovation and Technology (EIT) under grant agreement No 220385. This European body receives support from the Horizon 2020 research and innovation programme.
RiuNet. Repositorio Institucional de la Universitat Politécnica de Valéncia
Publicación Artículo científico (JournalArticle)

Regional conduction velocities determined by noninvasive mapping are associated with arrhythmia-free survival after atrial fibrillation ablation

  • Invers-Rubio, Eric
  • Hernández-Romero, Ismael
  • Reventós-Presmanes, Jana
  • Ferró, Elisenda
  • Guichard, Jean Baptiste
  • Regany-Closa, Mariona
  • Pellicer-Sendra, Berta
  • Borrás, Roger
  • Tolosana, José María
  • Prat-Gonzalez, Susanna
  • Porta-Sanchez, Andreu
  • Arbelo, Elena
  • Guasch, Eduard
  • Sitges, Marta
  • Brugada, Josep
  • Roca-Luque, Ivo
  • Lluís Mont
  • TF Althoff
  • Guillem Sánchez, María Salud|||0000-0001-5660-3693
  • Andreu M. Climent|||0000-0002-7260-8811
[EN] BACKGROUND Atrial arrhythmogenic substrate is a key determinant of atrial fibrillation (AF) recurrence after pulmonary vein isolation (PVI), and reduced conduction velocities have been linked to adverse outcome. However, a noninvasive method to assess such electrophysiologic substrate is not available to date. OBJECTIVE This study aimed to noninvasively assess regional conduction velocities and their association with arrhythmia-free survival after PVI. METHODS A consecutive 52 patients scheduled for AF ablation (PVI only) and 19 healthy controls were prospectively included and received electrocardiographic imaging (ECGi) to noninvasively determine regional atrial conduction velocities in sinus rhythm. A novel ECGi technology obviating the need of additional computed tomography or cardiac magnetic resonance imaging was applied and validated by invasive mapping. RESULTS Mean ECGi-determined atrial conduction velocities were significantly lower in AF patients than in healthy controls (1.45 6 0.15 m/s vs 1.64 6 0.15 m/s; P < .0001). Differences were particularly pronounced in a regional analysis considering only the segment with the lowest average conduction velocity in each patient (0.8 6 0.22 m/s vs 1.08 6 0.26 m/s; P < .0001). This average conduction velocity of the ¿slowest¿ segment was independently associated with arrhythmia recurrence and better discriminated between PVI responders and nonresponders than previously proposed predictors, including left atrial size and late gadolinium enhancement (magnetic resonance imaging). Patients without slow-conduction areas (mean conduction velocity <0.78 m/s) showed significantly higher 12-month arrhythmia-free survival than those with 1 or more slow-conduction areas (88.9% vs 48.0%; P 5 .002). CONCLUSION This is the first study to investigate regional atrial conduction velocities noninvasively. The absence of ECGi-determined slow-conduction areas well discriminates PVI responders from nonresponders. Such noninvasive assessment of electrical arrhythmogenic substrate may guide treatment strategies and be a step toward personalized AF therapy., This work is supported in part by grants from the European Union s Horizon Research and Innovation Programme under the Marie Sk1odowska-Curie Grant Agreement (860974; to M.S.G.); Instituto de Salud Carlos III, Spanish Government, Madrid, Spain (FIS_PI16/00435 FIS_CIBER16; to L.M.); Ministerio de Ciencia e Innovación (supported by FEDER Fondo Europeo de Desarrollo Regional PI17/01106, PEJ2018-003617, and RYC2018-024346-I; to A.M.C.), EIT Health (SAVE-COR Activity code 220385, EIT Health is supported by EIT, a body of the European Union), Generalitat Valenciana Conselleria d Educació, Investigació, Cultura i Esport (ACIF/2020/265; to A.C.), and Spanish Agencia Estatal de Investigación (AEI), part of the Ministerio de Ciencia e Innovación, reference PID2020-119364RB-I00 (to A.C.).
RiuNet. Repositorio Institucional de la Universitat Politécnica de Valéncia
Publicación Artículo científico (JournalArticle)

Cost-Effectiveness Mathematical Model to Evaluate the Impact of Improved Cardiac Ablation Strategies for Atrial Fibrillation Treatment

  • Sánchez-Périz, Ixeia
  • Barrachina Martínez, Isabel|||0000-0003-3710-1190
  • Javier Diaz Carnicero
  • Andreu M. Climent|||0000-0002-7260-8811
  • Vivas-Consuelo, David|||0000-0003-2945-7525
[EN] Atrial fibrillation (AF) is the most common form of cardiac arrhythmia. Despite the frequency of the disease, the treatment strategies for AF are inefficient. We developed a cost-effectiveness model to evaluate potential improvements in the application of cardiac ablations to treat AF. These are surgical procedures to terminate the arrhythmia and restore Sinus Rhythm. A Markov Model with a time horizon of five years was built to represent the management of patients in AF. A Montecarlo simulation was developed as a sensitivity analysis when the effectiveness increases the estimate of the potential impact of an improvement on the efficacy of cardiac ablation. The result of the analysis showed 44% of patients were untreated in any way. The base case ends up with 45% of patients having sinus rhythm restored after five years. The Montecarlo simulation estimates that in 58% of cases, the alternative of increasing ablation effectiveness by 25% would be cost-effective. If the number of performed ablations is doubled, the robustness increases to 86%. In conclusion, the model of management of AF highlights the importance of not only increasing effectiveness, but also treating more patients. Our study shows that investing in new screening technology to increase the effectiveness of ablations would be cost-effective., This work was supported by Spanish Agencia Estatal de Investigación (AEI) (PID2020- 119364RB-I00 and RYC2018-024346-I) and the EIT Health (SAVE-COR Activity code 220385, EIT Health is supported by EIT, a body of the European Union).
RiuNet. Repositorio Institucional de la Universitat Politécnica de Valéncia
Publicación Artículo científico (JournalArticle)

Atrial Fibrillation Treatment Stratification Based on Artificial Intelligence-Driven Analysis of the Electrophysiological Complexity

  • Sanchez-De la Nava, Ana María
  • Ros, Santiago
  • Carta-Bergaz, Alejandro
  • González-Torrecilla, Esteban
  • Gonzalez Mansilla, Ana
  • Bermejo, Javier
  • Arenal, Ángel
  • Climent, Andreu M.
  • Atienza, Felipe
  • Guillem Sánchez, María Salud|||0000-0001-5660-3693
[EN] Background: Atrial Fibrillation (AF) treatment strategies are suboptimal and clinical predictors of success are limited. Artificial Intelligence (AI) has arisen as a powerful tool for treatment efficacy prediction. Objective: We developed an AI-driven platform for the stratification of patients based on noninvasive Electrocardiographic Imaging (ECGI) biomarkers and clinical parameters to evaluate and predict optimal patient treatment. Methods: We evaluated 204 patients treated according to clinical guidelines and characterized them at the electrophysiological level using ECGI recordings during AF. ECGI signals were calculated to obtain frequency and rotational biomarkers. Baseline clinical characteristics and treatment after inclusion were registered. Results: A clustering algorithm was calibrated taking three different variables for 1 year outcome prediction: (1) AF type (paroxysmal or persistent); (2) ECGI complexity score (calculated based on highest dominant frequency, median dominant frequency, and mean rotor time); and (3) type of treatment: rhythm control (drugs, AF ablation) or rate control. The cluster analysis classified patients into five groups: Low electrophysiological complexity patterns were associated with an improved outcome after ablation, regardless of the time duration of the AF. Intermediate complexity scores in paroxysmal AF had a favourable outcome with rhythm control treatments, but not in persistent AF patients. Cluster patterns with higher electrophysiological complexity were associated with a higher probability of AF recurrence, both in paroxysmal and persistent groups. The performance of the algorithm predicting the outcome was (AUC: 0.73 (0.63-0.81)), increasing overall performance with respect to conventional persistent and paroxysmal classification (AUC: 0.58 (0.48-0.68); p < 0.05). This algorithm was evaluated on the 20% test set, obtaining 90% prediction success. Conclusions: AI-driven analysis that combined clinical information with ECGI biomarkers increased the performance of conventional classification methods for AF treatment stratification., This study was supported in part by the Instituto de Salud Carlos III [PI17/01059, PI17/01106], Centro de Investigación Biomédica en Red de Enfermedades Cardiovasculares (CIBERCV), Spanish Ministry of Science and Innovation, Spain, and cofunded by Fondo Europeo de Desarrollo Regional (FEDER), EIT Health 19600 AFFINE and EIT Health (SAVE&#8208;COR Activity code 220385) a body of the European Union.
RiuNet. Repositorio Institucional de la Universitat Politécnica de Valéncia
Publicación Artículo científico (JournalArticle)

AF driver detection in pulmonary vein area by electropcardiographic imaging: Relation with a favorable outcome of pulmonary vein isolation

  • Fambuena-Santos, Carlos
  • Andreu M. Climent|||0000-0002-7260-8811
  • Guillem Sánchez, María Salud|||0000-0001-5660-3693
  • Hernández-Romero, Ismael
  • Molero-Alabau, Rubén
  • Atienza, Felipe
[EN] Pulmonary vein isolation (PVI) is the most successful treatment for atrial fibrillation (AF) nowadays. However, not all AF patients benefit from PVI. In this study, we evaluate the use of ECGI to identify reentries and relate rotor density in the pulmonary vein (PV) area as an indicator of PVI outcome. Rotor maps were computed in a set of 29 AF patients using a new rotor detection algorithm. The relationship between the distribution of reentrant activity and the clinical outcome after PVI was studied. The number of rotors and proportion of PSs in different atrial regions were computed and compared retrospectively in two groups of patients: patients that remained in sinus rhythm 6 months after PVI and patients with arrhythmia recurrence. The total number of rotors obtained was higher in patients returning to arrhythmia after the ablation (4.31 ± 2.77 vs. 3.58 ± 2.67%, p = 0.018). However, a significantly higher concentration of PSs in the pulmonary veins was found in patients that remained in sinus rhythm (10.20 ± 12.40% vs. 5.19 ± 9.13%, p = 0.011) 6 months after PVI. The results obtained show a direct relationship between the expected AF mechanism and the electrophysiological parameters provided by ECGI, suggesting that this technology offers relevant information to predict the clinical outcome after PVI in AF patients., This project has received funding from the European Union's Horizon 2020 research and innovation program under the Marie Sklodowska-Curie grant agreement No 860974, PersonalizeAF, Ministerio de Ciencia e Innovacion (supported by FEDER Fondo Europeo de Desarrollo Regional PI17/01106, PEJ2018-003617, and RYC2018-024346-I), EIT Health (SAVE-COR Activity code 220385, EIT Health is supported by EIT, a body of the European Union), Generalitat Valenciana Conselleria d'Educacio, Investigacio, Cultura i Esport (ACIF/2020/265) and Spanish Agencia Estatal de Investigacion (AEI), part of the Ministerio de Ciencia e Innovacion, reference PID2020-119364RB-I00. *This publication reflects only the author's view and that the Agency is not responsible for any use that may be made of the information it contains.
RiuNet. Repositorio Institucional de la Universitat Politécnica de Valéncia
Publicación Artículo científico (JournalArticle)

Effects of torso mesh density and electrode distribution on the accuracy of electrocardiographic imaging during atrial fibrillation

  • Molero-Alabau, Rubén
  • Gonzalez-Ascaso, Ana
  • Hernández-Romero, Ismael
  • Lundbäck-Mompó, David
  • Andreu M. Climent|||0000-0002-7260-8811
  • Guillem Sánchez, María Salud|||0000-0001-5660-3693
[EN] Introduction: Electrocardiographic Imaging (ECGI) allows computing the electrical activity in the heart non-invasively using geometrical information of the patient and multiple body surface signals. In the present study we investigate the influence of the number of nodes of geometrical meshes and recording ECG electrodes distribution to compute ECGI during atrial fibrillation (AF).Methods: Torso meshes from 100 to 2000 nodes heterogeneously and homogeneously distributed were compared. Signals from nine AF realistic mathematical simulations were used for computing the ECGI. Results for each torso mesh were compared with the ECGI computed with a 4,000 nodes reference torso. In addition, real AF recordings from 25 AF patients were used to compute ECGI in torso meshes from 100 to 1,000 nodes. Results were compared with a reference torso of 2000 nodes. Torsos were remeshed either by reducing the number of nodes while maximizing the overall shape preservation and then assigning the location of the electrodes as the closest node in the new mesh or by forcing the remesher to place a node at each electrode location. Correlation coefficients, relative difference measurements and relative difference of dominant frequencies were computed to evaluate the impact on signal morphology of each torso mesh.Results: For remeshed torsos where electrodes match with a geometrical node in the mesh, all mesh densities presented similar results. On the other hand, in torsos with electrodes assigned to closest nodes in remeshed geometries performance metrics were dependent on mesh densities, with correlation coefficients ranging from 0.53 +/- 0.06 to 0.92 +/- 0.04 in simulations or from 0.42 +/- 0.38 to 0.89 +/- 0.2 in patients. Dominant frequency relative errors showed the same trend with values from 1.14 +/- 0.26 to 0.55 +/- 0.21 Hz in simulations and from 0.91 +/- 0.56 to 0.45 +/- 0.41 Hz in patients.Conclusion: The effect of mesh density in ECGI is minimal when the location of the electrode is preserved as a node in the mesh. Torso meshes constructed without imposing electrodes to constitute nodes in the torso geometry should contain at least 400 nodes homogeneously distributed so that a distance between nodes is below 4 cm., This work was supported by: Instituto de Salud Carlos III, and Ministerio de Ciencia e Innovacion (supported by FEDER Fondo Europeo de Desarrollo Regional PI17/01106, PEJ2018003617 and RYC2018-024346-I), EIT Health (Activity code 220385, EIT Health is supported by EIT, a body of the European Union), Generalitat Valenciana Conselleria d'Educacio, Investigacio, Cultura i Esport (ACIF/2020/265) and Spanish Agencia Estatal de Investigacion (AEI), part of the Ministerio de Ciencia e Innovacion, reference PID2020-119364RB-I00.
RiuNet. Repositorio Institucional de la Universitat Politécnica de Valéncia
Publicación Artículo científico (JournalArticle)

Real-Time Cardiac Mapping with a Noninvasive Imageless Electrocardiographic Imaging System

  • Reventós-Presmanes, Jana
  • Cano-Cabañero, Andrea
  • Hernández-Romero, Ismael
  • Lundback, David
  • Martínez, Marta
  • Moler, Ruben
  • Milagro, Javier
  • Pellicer-Sendra, Berta
  • Regany-Closa, Mariona
  • Ros Ruiz, Santiago
  • Fambuena-Santos, Carlos
  • Correas-García, María
  • Herrero-Martín, Clara|||0000-0001-5053-296X
  • Llorente-Lipe, Inés|||0009-0005-3386-0407
  • Moreno-López, Raúl
  • Andreu M. Climent|||0000-0002-7260-8811
[EN] Rapid, safe, and effective cardiac mapping is critical for the management of complex arrhythmias, yet current methods face significant limitations. The 12-lead electrocardiogram (ECG), while essential for initial diagnosis, lacks the spatial resolution and depth needed to guide advanced procedures such as catheter ablation or cardiac resynchronization therapy device implantation. On the other hand, invasive mapping techniques provide detailed electrical activity but require multiple catheter placements, increasing procedural risks and complexity. These methods are time-consuming, expensive, and offer limited real-time assessment, especially in dynamic arrhythmias like atrial fibrillation (AF), unstable arrhythmia, and cardiac resynchronization therapy (CRT). This study introduces a noninvasive, imageless electrocardiographic imaging (Imageless-ECGI) system designed to complement traditional methods by providing real-time, beat-to-beat cardiac maps. Without the need for pre-procedural imaging, this system captures high-resolution electrical activity across the entire heart, offering a safer and more efficient alternative to invasive mapping. By combining the immediacy of surface recordings with the spatial accuracy of modern computational models, the Imageless-ECGI system bridges the gap between traditional ECG and invasive mapping, potentially transforming the workflow in electrophysiology labs., also acknowledge support from the CERCA Programme/Generalitat de Catalunya. MPL funded (2023-2025) through a Rio Hortega contract CM22/00107 [Instituto de Salud Carlos III (ISCIII) ; Fondo Social Europeo (FSE) ] . The authors thank Neus Portella and Sheila Marco for providing secretarial support, and to the medical and nursing teams for their clinical support at Hospital Clinic de Barcelona, Hospital General Universitario Gregorio Maranon, Hospital Universitari i Politecnic La Fe. They also extend they're thanks to Almudena Albertos from Corify Care SL, Madrid, Spain and Arantxa Carrasco from Universitat Politecnica de Valencia.r also acknowledge support from the CERCA Programme/Generalitat de Catalunya. MPL funded (2023-2025) through a Rio Hortega contract CM22/00107 [Instituto de Salud Carlos III (ISCIII) ; Fondo Social Europeo (FSE) ] . The authors thank Neus Portella and Sheila Marco for providing secretarial support, and to the medical and nursing teams for their clinical support at Hospital Clinic de Barcelona, Hospital General Universitario Gregorio Maranon, Hospital Universitari i Politecnic La Fe. They also extend they're thanks to Almudena Albertos from Corify Care SL, Madrid, Spain and Arantxa Carrasco from Universitat Politecnica de Valencia.
RiuNet. Repositorio Institucional de la Universitat Politécnica de Valéncia
Publicación Artículo científico (JournalArticle)

DYNAMO Framework: Advancing non-invasive, rapid calibration in cardiac digital twin technology

  • Herrero-Martín, Clara|||0000-0001-5053-296X
  • Sánchez-Arciniegas, Jorge Patricio
  • Guillem Sánchez, María Salud|||0000-0001-5660-3693
  • Andreu M. Climent|||0000-0002-7260-8811
  • Molero, Rubén
  • Reventós-Presmanes, Jana
  • Guichard, Jean-Baptiste
  • Althoff, Till
  • Porta-Sanchez, Andreu
  • Roca-Luque, Ivo
  • Mont, Lluís
  • Hernández-Romero, Ismael
[EN] Introduction: Atrial arrhythmias management remains a significant challenge in cardiac electrophysiology. Cardiac digital twins (CDTs) offer a promising solution for individualized treatment. However, existing models are limited by invasive input requirements or long computational times. This paper introduces DYNAMO, a framework that leverages non-invasive electrocardiographic imaging (ECGI) to create CDTs. Methods: DYNAMO utilizes a reaction-diffusion automata model, reducing computational demands while capturing personalized cardiac dynamics using ECGI data. The calibration process maps ECGI data into CDTs by extracting key parameters for personalization, specifically LATs and conduction velocities. The framework was validated against detailed models and patient data in sinus rhythm (SR) and atrial flutter (AFl), comparing local activation times (LATs) and body surface potential maps (BSPM) for models, and focusing on BSPM for patients. Results: In-silico and clinical validation demonstrated the effectiveness of the framework. CDTs closely replicated cardiac dynamics, with an average LAT difference of 3.8 ms for SR models and 8.03 ms for AFl. For patients, CDTs achieved a high BSPM cross-correlation, with values averaging 0.89 for SR and 0.75 for AFl, and successfully replicated the ablation outcome in an AFl scenario. The framework also demonstrated superior computational efficiency compared to traditional models for equivalent simulations. Conclusions: DYNAMO represents a significant advancement in personalized cardiac health management. Using non-invasive ECGI to create CDTs offers an efficient approach to cardiac modeling. Its capability to simulate treatment strategies holds promise for improving clinical outcomes in atrial arrhythmia management. This study lays the basis for the broader application of ECGI in personalized medicine., This work was supported by the Generalitat Valenciana Grants (ACIF/2021/205, CIBEFP/2022/9, CIAPOS/2021/238, CIGE/2022/02, CIAICO/2022/020) and by ESF Invest in your future. This work was supported by MCIN/AEI/10.13039/501100011033 grants PID2020- 119364RB-I00, RYC2018-024346-I, CNS2022-135512, CPP2021- 008562, PTQ2023-013018, PTQ2023-012972 and by European Union NextGenerationEU/PRTR and by FEDER Fondo Europeo de Desarrollo Regional. This research has received funding from the European Institute of Innovation and Technology (EIT) under grant agreements No 220385 and 250027. This European body receives support from the Horizon 2020 research and innovation programme.