Pasar al contenido principal

Resultados relacionados

Resultados totales (Incluyendo duplicados): 4
Encontrada(s) 1 página(s)

RiuNet. Repositorio Institucional de la Universitat Politécnica de Valéncia
Publicación Artículo científico (JournalArticle)

Electrocardiographic Imaging: A New Tool to Ensure Cardiac Resynchronization During Left Bundle Branch Pacing Implant

  • Pujol-López, Margarida
  • Regany-Closa, Mariona
  • Pellicer-Sendra, Berta
  • Martínez-Pérez, Marta
  • Molero, Ruben
  • Graterol, Freddy R.
  • Guasch, Eduard
  • Tolosana, José M.
  • Mont, Lluís
  • Guillem Sánchez, María Salud|||0000-0001-5660-3693
[EN] Left bundle branch pacing (LBBP) has emerged as an alternative to biventricular pacing for cardiac resynchronization therapy (CRT). The objective is to pursue and ensure resynchronization. However, LBBP capture could fail to achieve adequate resynchronization in some patients, in whom biventricular pacing should be attempted., M.P.-L. is currently funded (2023-2025) through a Rio Hortega contract CM22/00107 [Instituto de Salud Carlos III (ISCIII); Fondo Social Europeo(FSE)]. J.M.T. and M.P.-L. received funding for Project in Conduction System Pacing (FIS PI21/00615) from Instituto de Salud Carlos III (Madrid, Spain). L.M.was funded by a 2021 Support for Research Groups grant from the Catalan government (2021_SGR_01350, SGR21/GENCAT), Catalonia, Spain. J.M.T., L.M.,M.R.-C., M.P.-L., and M.S.G. were funded by "La Marato de TV3 Fundacio", project: 202335 10, Barcelona, Catalonia, Spain. The authors thank the CERCAProgramme/Generalitat de Catalunya for the support to Institut d'Investigacions Biomediques August Pi i Sunyer (IDIBAPS). M.S.G and M.M.-P were funded byEIT Health and H2020 Grant n & zcaron; 230129. R.M. was funded by PTQ2023-012972 and CPP2021-008562 (CARE-ECGI). B.P.-S and M.S.G were supported byPLEC2021-007614 funded by MCIN/AEI/10.13039/501100011033 and EU NextGenerationEU/PRTR. This publication is part of the CPP2021-008562 CARE-ECGIproject -Cardiac resynchronization therapy based on electrocardiographic imaging-, funded by MCIN/AEI/10.13039/501100011033 and by the European Union"NextGenerationEU/PRTR".
RiuNet. Repositorio Institucional de la Universitat Politécnica de Valéncia
Publicación Artículo científico (JournalArticle)

Real-Time Cardiac Mapping with a Noninvasive Imageless Electrocardiographic Imaging System

  • Reventós-Presmanes, Jana
  • Cano-Cabañero, Andrea
  • Hernández-Romero, Ismael
  • Lundback, David
  • Martínez, Marta
  • Moler, Ruben
  • Milagro, Javier
  • Pellicer-Sendra, Berta
  • Regany-Closa, Mariona
  • Ros Ruiz, Santiago
  • Fambuena-Santos, Carlos
  • Correas-García, María
  • Herrero-Martín, Clara|||0000-0001-5053-296X
  • Llorente-Lipe, Inés|||0009-0005-3386-0407
  • Moreno-López, Raúl
  • Andreu M. Climent|||0000-0002-7260-8811
[EN] Rapid, safe, and effective cardiac mapping is critical for the management of complex arrhythmias, yet current methods face significant limitations. The 12-lead electrocardiogram (ECG), while essential for initial diagnosis, lacks the spatial resolution and depth needed to guide advanced procedures such as catheter ablation or cardiac resynchronization therapy device implantation. On the other hand, invasive mapping techniques provide detailed electrical activity but require multiple catheter placements, increasing procedural risks and complexity. These methods are time-consuming, expensive, and offer limited real-time assessment, especially in dynamic arrhythmias like atrial fibrillation (AF), unstable arrhythmia, and cardiac resynchronization therapy (CRT). This study introduces a noninvasive, imageless electrocardiographic imaging (Imageless-ECGI) system designed to complement traditional methods by providing real-time, beat-to-beat cardiac maps. Without the need for pre-procedural imaging, this system captures high-resolution electrical activity across the entire heart, offering a safer and more efficient alternative to invasive mapping. By combining the immediacy of surface recordings with the spatial accuracy of modern computational models, the Imageless-ECGI system bridges the gap between traditional ECG and invasive mapping, potentially transforming the workflow in electrophysiology labs., also acknowledge support from the CERCA Programme/Generalitat de Catalunya. MPL funded (2023-2025) through a Rio Hortega contract CM22/00107 [Instituto de Salud Carlos III (ISCIII) ; Fondo Social Europeo (FSE) ] . The authors thank Neus Portella and Sheila Marco for providing secretarial support, and to the medical and nursing teams for their clinical support at Hospital Clinic de Barcelona, Hospital General Universitario Gregorio Maranon, Hospital Universitari i Politecnic La Fe. They also extend they're thanks to Almudena Albertos from Corify Care SL, Madrid, Spain and Arantxa Carrasco from Universitat Politecnica de Valencia.r also acknowledge support from the CERCA Programme/Generalitat de Catalunya. MPL funded (2023-2025) through a Rio Hortega contract CM22/00107 [Instituto de Salud Carlos III (ISCIII) ; Fondo Social Europeo (FSE) ] . The authors thank Neus Portella and Sheila Marco for providing secretarial support, and to the medical and nursing teams for their clinical support at Hospital Clinic de Barcelona, Hospital General Universitario Gregorio Maranon, Hospital Universitari i Politecnic La Fe. They also extend they're thanks to Almudena Albertos from Corify Care SL, Madrid, Spain and Arantxa Carrasco from Universitat Politecnica de Valencia.
RiuNet. Repositorio Institucional de la Universitat Politécnica de Valéncia
Publicación Artículo científico (JournalArticle)

Noninvasive assessment of the ventricular arrhythmogenic substrate using electrocardiographic imaging during sinus rhythm: The NIAVAS study

  • Reventós-Presmanes, Jana
  • Hernández-Romero, Ismael
  • Pecllier-Sendra, B.
  • Guillen-Buisan, E.
  • Serrano-Campaner, J.
  • Invers-Rubio, E.
  • Regany-Closa, M.
  • Garre, Paz
  • Borras, Roger
  • Costafreda, Adriana
  • Arbelo, Elena
  • Tolosana, Jose M.
  • Guasch, E.
  • Althoff, Till F.
  • Guichard, Jean-Baptiste
  • Falzone, Pasquale V.
  • Vázquez-Calvo, Sara
  • Elivhots Ayauja
  • Porta-Sanchez, Andreu
  • Roca-Luque, Ivo
  • Guillem Sánchez, María Salud|||0000-0001-5660-3693
  • Andreu M. Climent|||0000-0002-7260-8811
[EN] Background Late gadolinium enhancement cardiac magnetic resonance (LGE-CMR) identifies structural properties associated with ventricular tachycardia (VT) but lacks functional information. Noninvasive identification of slow conduction regions using electrocardiographic imaging (ECGI) could complement LGE-CMR to aid VT risk stratification. Objective This study aimed to evaluate the relationship between ventricular arrhythmogenic substrate and regional ECGI markers during sinus rhythm in patients with ischemic cardiomyopathy (ICM). Methods Seventy-two patients were included: 29 with ICM evidenced by LGE-CMR referred for VT ablation, 17 with ICM with implantable cardioverter-defibrillator for primary prevention without documented VT, and 26 controls. ECGI-derived regional activation dispersion (rAD) and pseudo-regional conduction velocity (pseudo-rCV) were analyzed and compared between scarred and healthy regions based on LGE, and between patients with ICM with and without previous VT. In a subgroup with electroanatomic mapping (n = 16), deceleration zones were correlated with ECGI. Results Scarred regions showed higher rAD (46.3 ± 2.2 vs 30.1 ± 1.7 ms, P < .001) and reduced pseudo-rCV (149.9 ± 3.0 vs 165.7 ± 2.4 cm/s, P < .001) than healthy regions. In the subgroup with sinus rhythm electroanatomic mapping, regions containing deceleration zones showed increased rAD (64.9 ± 5.4 vs 43.1 ± 3.1 ms, P < .001), and ECGI identified 70.4% of those zones. At the patient level, the mean of the 3 regions with the highest activation dispersion differentiated patients with ICM with and without previous VT (rAD ¿60.0 ms, sensitivity 75.9%, area under the curve [AUC] 0.75, P = .005) and identified patients with ICM from controls (rAD ¿39.5 ms, AUC 0.93). Conclusion This study introduces a novel regional ECGI methodology demonstrating that rAD identifies abnormalities linked to arrhythmogenic substrate and could help identify patients at risk of VT. These findings highlight ECGI¿s potential as a complementary tool to LGE-CMR., This research was funded by the European Institute of Innovation and Technology (EIT Health) under grant agreement no. 230129. In addition, the research was supported by Ministerio de Ciencia, Innovación y Universidades MCIN/AEI/10.13039/501100011033 (grant PID2023-149812OB-I00), European Union NextGenerationEU/Plan de Recuperación, Transformación y Resiliencia (CNS2022-135512, PTQ2023-013018, and CPP2021- 008562), and Fondo Europeo de Desarrollo Regional European Union (CPP2023-010504). Additional support came from Generalitat Valenciana and European Social Fund Investing in Your Future (grants CIAPOS/2021/238 and CIAICO/2022/020), Instituto de Salud Carlos III (grant CIBERCV16 CB16/11/00354), and Catalonia, Spain (grants 2021_SGR_01350 and SGR21/GENCAT).
RiuNet. Repositorio Institucional de la Universitat Politécnica de Valéncia
Publicación Artículo científico (JournalArticle)

Substrate Mapping for Ventricular Tachycardia Ablation Through High-Density Whole-Chamber Double Extra Stimuli The S3 Protocol

  • Guichard, Jean Baptiste
  • Regany-Closa, Mariona
  • Vázquez-Calvo, Sara
  • Zazu, Blanca
  • Pellicer Sendra, Berta
  • Serrano-Campaner, Jaume
  • Molero-Pereira, Silvia
  • Borras, Roger
  • Ortiz, Jose Tomas
  • Falzone, Pasquale Valerio
  • Eulogio, Frida
  • Reventós-Presmanes, Jana
  • Garre, Paz
  • Arbelo, Elena
  • Althoff, Till Friedrisch
  • Eduard Guasch
[EN] Background: A partial delineation of targets for ablation of ventricular tachycardia (VT) during a stable rhythm is likely responsible for a suboptimal success rate. The abnormal low-voltage near-field functional components may be hidden within the high-amplitude far-field signal. Objectives: The aim of this study was to evaluate the benefit and feasibility of functional substrate mapping using a full-ventricle S3 protocol and to assess its colocalization with arrhythmogenic conducting channels (CCs) on late gadolinium enhancement cardiac magnetic resonance. Methods: An S3 mapping protocol with a drive train of S1 followed by S2 (effective refractory period + 30 ms) and S3 (effective refractory period + 50 ms) from the right ventricular apex was performed in 40 consecutive patients undergoing scar-related VT ablation. Deceleration zones (DZs) and areas of late potentials (LPs) were identified for all maps. A preprocedural noninvasive substrate assessment was done using late gadolinium enhancement cardiac magnetic resonance and postprocessing with automated CC identification. Results: The S3 protocol was completed in 34 of the 40 procedures (85.0%). The S3 protocol enhanced the identification of VT isthmus on the basis of DZ (89% vs 62%; P < 0.01) and LP (93% vs 78%; P = 0.04) assessment. The percentage of CCs unmasked by DZs and LPs using S3 maps was significantly higher than the ones using S2 and S1 maps (78%, 65%, and 48% [P < 0.001] and 88%, 81%, and 68% [P < 0.01], respectively). The functional substrate identified during S3 activation mapping was significantly more extensive than the one identified using S2 and S1, including a greater number of DZs (2.94, 2.47, and 1.82, respectively; P < 0.001) and a wider area of LPs (44.1, 38.2, and 29.4 cm(2), respectively; P < 0.001). After VT ablation, 77.9% of patients have been VT free during a median follow-up period of 13.6 months. Conclusions: The S3 protocol was feasible in 85% of patients, allows a better identification of targets for ablation, and might improve VT ablation results., Dr Guichard has received institutional grant support from the French Federation of Cardiology and from "Contractes d'Investigacio Avan-cada Fundacio BBVA-Hospital Clinic Barcelona Joan Rodes - Josep Baselga 2022" (HCB_BIO_001/2) . This study was supported in part by grant PI20/00693, FEDER (European Commission) /CB16/11/00354, Instituto de Salud Carlos III, and grant 2021_SGR_01350, SGR21/GEN-CAT.