Pasar al contenido principal

Cardiac Electrophysiology Biomedical Engineering

RYC2018-024346-I

•
Nombre agencia financiadora Agencia Estatal de Investigación
Acrónimo agencia financiadora AEI
Programa Programa Estatal de Promoción del Talento y su Empleabilidad en I+D+i
Subprograma Subprograma Estatal de Incorporación
Convocatoria Ramón y Cajal
Año convocatoria 2018
Plan Estatal 2017-2020 Plan Estatal de Investigación Científica y Técnica y de Innovación
Centro beneficiario UNIVERSITAT POLITÈCNICA DE VALÈNCIA

Resultados relacionados

Resultados totales (Incluyendo duplicados): 9
Encontrada(s) 1 página(s)

RiuNet. Repositorio Institucional de la Universitat Politécnica de Valéncia
Publicación Artículo científico (JournalArticle)

Validation of an imageless electrocardiographic imaging technique for the non-invasive mapping of regular atrial tachyarrhythmias

  • Reventós-Presmanes, Jana
  • Cano-Cabañero, Andrea
  • Invers-Rubio, Eric
  • Pellicer-Sendra, Berta
  • Serrano-Campaner, Jaume
  • Zacur, Ernesto
  • Althoff, Till F
  • Hernández-Romero, Ismael
  • Borràs, Roger
  • Regany-Closa, Mariona
  • Arbelo, Elena
  • Guasch, Eduard
  • Tolosana, Jose María
  • Porta-Sánchez, Andreu
  • Herrero-Martín, Clara|||0000-0001-5053-296X
  • Andreu M. Climent|||0000-0002-7260-8811
  • Guillem Sánchez, María Salud|||0000-0001-5660-3693
[EN] This study validates the clinical performance of an imageless ECGi system for the characterization of regular atrial tachyarrhythmias. Its ability to provide rapid, full-chamber activation maps from a single beat may make it a potential solution for mapping transient arrhythmias or rhythm changes during ablation procedures., This project has been funded by grants PID2023-149812OB-I00, DIN2024-013365, PTQ2023-013018, PTQ2022-012632, RYC2018-024346-I, CNS2022-135512, and CPP2023-010504 funded by Ministerio de Ciencia, Innovacion y Universidades MCIN/AEI/10.13039/501100011033 and by the European Union NextGenerationEU/Plan de Recuperacion, Transformacion y Resiliencia. This project has been funded by Generalitat Valenciana by grants ACIF/2021/205 and CIAICO/2022/020 and by European Social Fund Investing in Your Future. This project also received funding from European Institute of Innovation and Technology (EIT Health) (activity codes 220385, 230129, and 250027). Additionally, this work was supported by a research grant from Instituto de Salud Carlos III, which is co-funded by the European Union (grant PI22/00441). J.-B.G. acknowledges support from the grants 'Contractes d'Investigacio Avancada Fundacio BBVA' - Hospital Clinic Barcelona Joan Rodes-Josep Baselga 2022' (HCB_BIO_001/2) and the 'Daniel Bravo Andreu Private Foundation 2024 Grants' for short stays abroad in biomedical research.
RiuNet. Repositorio Institucional de la Universitat Politécnica de Valéncia
Publicación Artículo científico (JournalArticle)

Regional conduction velocities determined by noninvasive mapping are associated with arrhythmia-free survival after atrial fibrillation ablation

  • Invers-Rubio, Eric
  • Hernández-Romero, Ismael
  • Reventós-Presmanes, Jana
  • Ferró, Elisenda
  • Guichard, Jean Baptiste
  • Regany-Closa, Mariona
  • Pellicer-Sendra, Berta
  • Borrás, Roger
  • Tolosana, José María
  • Prat-Gonzalez, Susanna
  • Porta-Sanchez, Andreu
  • Arbelo, Elena
  • Guasch, Eduard
  • Sitges, Marta
  • Brugada, Josep
  • Roca-Luque, Ivo
  • Lluís Mont
  • TF Althoff
  • Guillem Sánchez, María Salud|||0000-0001-5660-3693
  • Andreu M. Climent|||0000-0002-7260-8811
[EN] BACKGROUND Atrial arrhythmogenic substrate is a key determinant of atrial fibrillation (AF) recurrence after pulmonary vein isolation (PVI), and reduced conduction velocities have been linked to adverse outcome. However, a noninvasive method to assess such electrophysiologic substrate is not available to date. OBJECTIVE This study aimed to noninvasively assess regional conduction velocities and their association with arrhythmia-free survival after PVI. METHODS A consecutive 52 patients scheduled for AF ablation (PVI only) and 19 healthy controls were prospectively included and received electrocardiographic imaging (ECGi) to noninvasively determine regional atrial conduction velocities in sinus rhythm. A novel ECGi technology obviating the need of additional computed tomography or cardiac magnetic resonance imaging was applied and validated by invasive mapping. RESULTS Mean ECGi-determined atrial conduction velocities were significantly lower in AF patients than in healthy controls (1.45 6 0.15 m/s vs 1.64 6 0.15 m/s; P < .0001). Differences were particularly pronounced in a regional analysis considering only the segment with the lowest average conduction velocity in each patient (0.8 6 0.22 m/s vs 1.08 6 0.26 m/s; P < .0001). This average conduction velocity of the ¿slowest¿ segment was independently associated with arrhythmia recurrence and better discriminated between PVI responders and nonresponders than previously proposed predictors, including left atrial size and late gadolinium enhancement (magnetic resonance imaging). Patients without slow-conduction areas (mean conduction velocity <0.78 m/s) showed significantly higher 12-month arrhythmia-free survival than those with 1 or more slow-conduction areas (88.9% vs 48.0%; P 5 .002). CONCLUSION This is the first study to investigate regional atrial conduction velocities noninvasively. The absence of ECGi-determined slow-conduction areas well discriminates PVI responders from nonresponders. Such noninvasive assessment of electrical arrhythmogenic substrate may guide treatment strategies and be a step toward personalized AF therapy., This work is supported in part by grants from the European Union s Horizon Research and Innovation Programme under the Marie Sk1odowska-Curie Grant Agreement (860974; to M.S.G.); Instituto de Salud Carlos III, Spanish Government, Madrid, Spain (FIS_PI16/00435 FIS_CIBER16; to L.M.); Ministerio de Ciencia e Innovación (supported by FEDER Fondo Europeo de Desarrollo Regional PI17/01106, PEJ2018-003617, and RYC2018-024346-I; to A.M.C.), EIT Health (SAVE-COR Activity code 220385, EIT Health is supported by EIT, a body of the European Union), Generalitat Valenciana Conselleria d Educació, Investigació, Cultura i Esport (ACIF/2020/265; to A.C.), and Spanish Agencia Estatal de Investigación (AEI), part of the Ministerio de Ciencia e Innovación, reference PID2020-119364RB-I00 (to A.C.).
RiuNet. Repositorio Institucional de la Universitat Politécnica de Valéncia
Publicación Artículo científico (JournalArticle)

Effects of torso mesh density and electrode distribution on the accuracy of electrocardiographic imaging during atrial fibrillation

  • Molero-Alabau, Rubén
  • Gonzalez-Ascaso, Ana
  • Hernández-Romero, Ismael
  • Lundbäck-Mompó, David
  • Andreu M. Climent|||0000-0002-7260-8811
  • Guillem Sánchez, María Salud|||0000-0001-5660-3693
[EN] Introduction: Electrocardiographic Imaging (ECGI) allows computing the electrical activity in the heart non-invasively using geometrical information of the patient and multiple body surface signals. In the present study we investigate the influence of the number of nodes of geometrical meshes and recording ECG electrodes distribution to compute ECGI during atrial fibrillation (AF).Methods: Torso meshes from 100 to 2000 nodes heterogeneously and homogeneously distributed were compared. Signals from nine AF realistic mathematical simulations were used for computing the ECGI. Results for each torso mesh were compared with the ECGI computed with a 4,000 nodes reference torso. In addition, real AF recordings from 25 AF patients were used to compute ECGI in torso meshes from 100 to 1,000 nodes. Results were compared with a reference torso of 2000 nodes. Torsos were remeshed either by reducing the number of nodes while maximizing the overall shape preservation and then assigning the location of the electrodes as the closest node in the new mesh or by forcing the remesher to place a node at each electrode location. Correlation coefficients, relative difference measurements and relative difference of dominant frequencies were computed to evaluate the impact on signal morphology of each torso mesh.Results: For remeshed torsos where electrodes match with a geometrical node in the mesh, all mesh densities presented similar results. On the other hand, in torsos with electrodes assigned to closest nodes in remeshed geometries performance metrics were dependent on mesh densities, with correlation coefficients ranging from 0.53 +/- 0.06 to 0.92 +/- 0.04 in simulations or from 0.42 +/- 0.38 to 0.89 +/- 0.2 in patients. Dominant frequency relative errors showed the same trend with values from 1.14 +/- 0.26 to 0.55 +/- 0.21 Hz in simulations and from 0.91 +/- 0.56 to 0.45 +/- 0.41 Hz in patients.Conclusion: The effect of mesh density in ECGI is minimal when the location of the electrode is preserved as a node in the mesh. Torso meshes constructed without imposing electrodes to constitute nodes in the torso geometry should contain at least 400 nodes homogeneously distributed so that a distance between nodes is below 4 cm., This work was supported by: Instituto de Salud Carlos III, and Ministerio de Ciencia e Innovacion (supported by FEDER Fondo Europeo de Desarrollo Regional PI17/01106, PEJ2018003617 and RYC2018-024346-I), EIT Health (Activity code 220385, EIT Health is supported by EIT, a body of the European Union), Generalitat Valenciana Conselleria d'Educacio, Investigacio, Cultura i Esport (ACIF/2020/265) and Spanish Agencia Estatal de Investigacion (AEI), part of the Ministerio de Ciencia e Innovacion, reference PID2020-119364RB-I00.
RiuNet. Repositorio Institucional de la Universitat Politécnica de Valéncia
Publicación Artículo científico (JournalArticle)

Real-Time Cardiac Mapping with a Noninvasive Imageless Electrocardiographic Imaging System

  • Reventós-Presmanes, Jana
  • Cano-Cabañero, Andrea
  • Hernández-Romero, Ismael
  • Lundback, David
  • Martínez, Marta
  • Moler, Ruben
  • Milagro, Javier
  • Pellicer-Sendra, Berta
  • Regany-Closa, Mariona
  • Ros Ruiz, Santiago
  • Fambuena-Santos, Carlos
  • Correas-García, María
  • Herrero-Martín, Clara|||0000-0001-5053-296X
  • Llorente-Lipe, Inés|||0009-0005-3386-0407
  • Moreno-López, Raúl
  • Andreu M. Climent|||0000-0002-7260-8811
[EN] Rapid, safe, and effective cardiac mapping is critical for the management of complex arrhythmias, yet current methods face significant limitations. The 12-lead electrocardiogram (ECG), while essential for initial diagnosis, lacks the spatial resolution and depth needed to guide advanced procedures such as catheter ablation or cardiac resynchronization therapy device implantation. On the other hand, invasive mapping techniques provide detailed electrical activity but require multiple catheter placements, increasing procedural risks and complexity. These methods are time-consuming, expensive, and offer limited real-time assessment, especially in dynamic arrhythmias like atrial fibrillation (AF), unstable arrhythmia, and cardiac resynchronization therapy (CRT). This study introduces a noninvasive, imageless electrocardiographic imaging (Imageless-ECGI) system designed to complement traditional methods by providing real-time, beat-to-beat cardiac maps. Without the need for pre-procedural imaging, this system captures high-resolution electrical activity across the entire heart, offering a safer and more efficient alternative to invasive mapping. By combining the immediacy of surface recordings with the spatial accuracy of modern computational models, the Imageless-ECGI system bridges the gap between traditional ECG and invasive mapping, potentially transforming the workflow in electrophysiology labs., also acknowledge support from the CERCA Programme/Generalitat de Catalunya. MPL funded (2023-2025) through a Rio Hortega contract CM22/00107 [Instituto de Salud Carlos III (ISCIII) ; Fondo Social Europeo (FSE) ] . The authors thank Neus Portella and Sheila Marco for providing secretarial support, and to the medical and nursing teams for their clinical support at Hospital Clinic de Barcelona, Hospital General Universitario Gregorio Maranon, Hospital Universitari i Politecnic La Fe. They also extend they're thanks to Almudena Albertos from Corify Care SL, Madrid, Spain and Arantxa Carrasco from Universitat Politecnica de Valencia.r also acknowledge support from the CERCA Programme/Generalitat de Catalunya. MPL funded (2023-2025) through a Rio Hortega contract CM22/00107 [Instituto de Salud Carlos III (ISCIII) ; Fondo Social Europeo (FSE) ] . The authors thank Neus Portella and Sheila Marco for providing secretarial support, and to the medical and nursing teams for their clinical support at Hospital Clinic de Barcelona, Hospital General Universitario Gregorio Maranon, Hospital Universitari i Politecnic La Fe. They also extend they're thanks to Almudena Albertos from Corify Care SL, Madrid, Spain and Arantxa Carrasco from Universitat Politecnica de Valencia.
RiuNet. Repositorio Institucional de la Universitat Politécnica de Valéncia
Publicación Artículo científico (JournalArticle)

Robustness of imageless electrocardiographic imaging against uncertainty in atrial morphology and location

  • Molero-Alabau, Rubén
  • González-Ascaso, Ana
  • Andreu M. Climent|||0000-0002-7260-8811
  • Guillem Sánchez, María Salud|||0000-0001-5660-3693
[EN] Introduction: Electrocardiographic Imaging is a non-invasive technique that requires cardiac Imaging for the reconstruction of cardiac electrical activity. In this study, we explored imageless ECGI by quantifying the errors of using heart meshes with either an inaccurate location inside the thorax or an inaccurate geometry. Methods: Multiple-lead body surface recordings of 25 atrial fibrillation (AF) patients were recorded. Cardiac atrial meshes were obtained by segmentation of medical images obtained for each patient. ECGI was computed with each patient's segmented atrial mesh and compared with the ECGI obtained under errors in the atrial mesh used for ECGI estimation. We modeled both the uncertainty in the location of the atria inside the thorax by artificially translating the atria inside the thorax and the geometry of the atrial mesh by using an atrial mesh in a reference database. ECGI signals obtained with the actual meshes and the translated or estimated meshes were compared in terms of their correlation coefficients, relative difference measurement star, and errors in the dominant frequency (DF) estimation in epicardial nodes.Results: CC between ECGI signals obtained after translating the actual atrial meshes from the original position by 1 cm was above 0.97. CC between ECGIs obtained with patient specific atrial geometry and estimated atrial geometries was 0.93 +/- 0.11. Mean errors in DF estimation using an estimated atrial mesh were 7.6 +/- 5.9%.Conclusion: Imageless ECGI can provide a robust estimation of cardiac electrophysiological parameters such as activation rates even during complex arrhythmias. Furthermore, it can allow more widespread use of ECGI in clinical practice., This work was supported by: Instituto de Salud Carlos III, and Ministerio de Ciencia e Innovacion (supported by FEDER Fondo Europeo de Desarrollo Regional DIDIMO PLEC2021-007614, ESSENCE PID2020-119364RB-I00, and RYC2018-024346-I) , EIT Health (Activity code SAVE-COR 220385, EIT Health is supported by EIT, a body of the Eu-ropean Union) and Generalitat Valenciana Conselleria d'Educacio, Investigacio, Cultura i Esport (ACIF/2020/265) . The authors want to thank the organizers of the 2022 meeting of the International Society for Computerized Electrocardiology for their invitation to the meeting.
RiuNet. Repositorio Institucional de la Universitat Politécnica de Valéncia
Publicación Artículo científico (JournalArticle)

Filtering strategies of electrocardiographic imaging signals for stratification of atrial fibrillation patients

  • Molero-Alabau, Rubén
  • Hernández-Romero, Ismael
  • Andreu M. Climent|||0000-0002-7260-8811
  • Guillem Sánchez, María Salud|||0000-0001-5660-3693
[EN] Background and objective: Electrocardiographic imaging (ECGI) has been used for guiding atrial fibrillation (AF) ablation, identifying reentrant activity by phase analysis with promising results. The objective of this study is to identify the best post-processing configuration for reentrant activity detection that better differentiates AF pa-tients with different prognoses after catheter ablation.Methods: ECGI signals of 24 AF patients before pulmonary vein isolation (PVI) were recorded. Patients were classified based on recurrence 6 months after PVI. Reentrant metrics were compared using 3 types of post -processing: none, sinusoidal recomposition (SRC), and narrow band-pass filtering centered at the highest dominant frequency (NB HDF). Different thresholds for rotor duration were also compared (0.5, 1, and 1.5 turns). Results: The use of raw ECGI signals with a threshold of 1 turn presented the optimal processing to identify PVI-positive responders (p < 0.05). NB HDF showed a better ability to find statistical differences between patients than SRC.Conclusion: Aggressive filtering of AF ECGI signals does not improve rotor identification to predict PVI outcome. Restrictive rotor duration thresholds diminish patient stratification. This definition of a post-processing strategy that allows patient stratification can be used for the improvement of the standard of care for finding the best candidates for PVI., This work was supported in part by: Instituto de Salud Carlos III FEDER (Fondo Europeo de Desarrollo Regional PI17/01106) , Agencia Estatal de Investigacion (RYC2018-024346-I and PID2020-119364RB-100) , Generalitat Valenciana Grants (ACIF/2020/265) and EIT Health (Activity code 19600) EIT Health is supported by EIT, a body of the European Union.
RiuNet. Repositorio Institucional de la Universitat Politécnica de Valéncia
Publicación Artículo científico (JournalArticle)

Enhancing premature ventricular contraction localization through electrocardiographic imaging and cardiac digital twins

  • Sánchez-Arciniegas, Jorge Patricio
  • Llorente-Lipe, Inés|||0009-0005-3386-0407
  • Guillem Sánchez, María Salud|||0000-0001-5660-3693
  • Barrios Espinosa, Cristian
  • Loewe, Axel
  • Hernández-Romero, Ismael
  • Vicente, Jorge
  • Ros, Santiago
  • Atienza, Felipe
  • Carta-Bergaz, Alejandro
  • Climent, Andreu M.
[EN] Premature ventricular contractions (PVCs) represent a common and clinically significant cardiac arrhythmia, contributing to a spectrum of cardiovascular disorders. Accurate localization of the origin of PVCs is essential for devising targeted therapeutic strategies and refining our comprehension of ventricular arrhythmogenesis. Traditionally, the 12-lead ECG has been the go-to diagnostic tool for PVCs. However, individual anatomical differences and inter-patient electrophysiology variability limit its effectiveness. This study presents a new method that combines electrocardiographic imaging (ECGI) with the concept of cardiac digital twins (ECGIDT) to improve the accuracy of pinpointing the source of PVCs. By simulating a database of PVCs, we developed an ECGI-DT capable of estimating the origins of PVCs with much greater precision than possible previously. This study shows a notable improvement in identifying the initial site of PVC origin using ECGI-DT compared to ECGI alone: the average localization error dropped from 30.69 ± 23.71 mm with standard ECGI to 7.81 ± 3.82 mm using the ECGI-DT method. This marked reduction in error highlights the potential of ECGI-DT in revolutionizing PVC diagnosis and treatment. With its ability to provide more accurate and reliable data, ECGI-DT could improve the planning of catheter ablation treatments, a preferred intervention for managing PVCs that face challenges such as high costs and in some cases long procedure times., This work was supported by grants PLEC2021-007614 funded by MCIN, Spain&#8725;AEI&#8725;10.13039&#8725;501100011033 and by European Union NextGenerationEU&#8725;PRTR . This was supported by grant RYC2018-024346-I and by ESF Investing in your future, Spain . This project has received funding from the European Union s Horizon 2020 research and innovation programme under the Marie Sk&#322;odowska-Curie grant agreement No. 860974. This work was supported by the Leibniz ScienceCampus, Germany Digital Transformation of Research with funds from the programme Strategic Networking in the Leibniz Association . This research was supported by Deutsche Forschungsgemeinschaft, Germany (DFG, German Research Foundation) under grant LO 2093/9-1.
RiuNet. Repositorio Institucional de la Universitat Politécnica de Valéncia
Publicación Artículo científico (JournalArticle)

Volumetric non-invasive cardiac mapping for accessible global arrhythmia characterization

  • Vicente-Puig, Jorge
  • Chamorro-Servent, Judit
  • Zacur, Ernesto
  • Llorente-Lipe, Ines
  • Martinez-Perez, Marta
  • Reventós-Presmanes, Jana
  • Roca-Luque, Ivo
  • Lluís Mont
  • Atienza, Felipe
  • Hernández-Romero, Ismael
  • Sánchez-Arciniegas, Jorge Patricio
  • Andreu M. Climent|||0000-0002-7260-8811
  • Guillem Sánchez, María Salud|||0000-0001-5660-3693
[EN] BackgroundCardiac arrhythmias are a major cause of morbidity and mortality increasing the risk of stroke, heart failure, and sudden cardiac death. Imageless electrocardiographic Imaging has emerged as an accessible non-invasive alternative for cardiac electrical mapping from body surface potentials. However, conventional electrocardiographic imaging is restricted to epicardial reconstructions, reducing its reliability in accurately identifying arrhythmias arising from deeper myocardial structures. We aim to overcome this limitation by reconstructing three-dimensional cardiac activity.MethodsWe introduce a volumetric formulation, which extends beyond epicardial potential estimation by solving an inverse source problem using Green's functions. This technique enables three-dimensional reconstructions of cardiac activation, improving arrhythmia localization in anatomically complex regions. We evaluate the method on simulated premature ventricular beats and on four patients representing clinical challenges, including a premature ventricular contraction from the right ventricular outflow tract, a left bundle branch block, a ventricular tachycardia, and a Wolff-Parkinson-White. We also assess performance on an open-source dataset for myocardial infarction estimation.ResultsOur results indicate that volumetric electrocardiographic imaging reconstructs three-dimensional activation and enhances the localization of arrhythmia origins, yielding a 59.3% reduction in geodesic error between the estimated and simulated origins compared to surface-only approaches. In patient cases, the recovered activation patterns are consistent with the clinical diagnoses.ConclusionsImageless volumetric electrocardiographic imaging enables non-invasive, accessible, three-dimensional mapping of cardiac activation, addressing a fundamental limitation of surface-restricted methods. This capability may support more accurate pre-procedural planning, may help guide ablation targets, and could refine selection and optimization of cardiac resynchronization therapy candidates., This research has received funding from grants n degrees DIN2022-012606, PTQ2022-012632, PTQ2023-013018, PID2023-149812OB-I00, PID2023-149812OB-I00, PI23/01569, CNS2022-135512, RYC2018-024346-I, CNS2022-135512, CERCA Program (Generalitat de Catalunya), AGAUR (2022 DI 022 and GRC-2021 SGR 00113), UAB PPC2023_575610, CPP2021-008562, CPP2024-011368, CPP2023-01050 funded by MCIN/AEI/10.13039/501100011033, by European Union NextGenerationEU/PRTR and by FEDER, EU. This research has also received funding from the European Institute of Innovation and Technology (EIT) under grant agreement No 250027. This European body receives support from the Horizon 2020 research and innovation programme. Additional support has been received by the Generalitat Valenciana with grant CIAICO/2022/020.
RiuNet. Repositorio Institucional de la Universitat Politécnica de Valéncia
Publicación Artículo científico (JournalArticle)

DYNAMO Framework: Advancing non-invasive, rapid calibration in cardiac digital twin technology

  • Herrero-Martín, Clara|||0000-0001-5053-296X
  • Sánchez-Arciniegas, Jorge Patricio
  • Guillem Sánchez, María Salud|||0000-0001-5660-3693
  • Andreu M. Climent|||0000-0002-7260-8811
  • Molero, Rubén
  • Reventós-Presmanes, Jana
  • Guichard, Jean-Baptiste
  • Althoff, Till
  • Porta-Sanchez, Andreu
  • Roca-Luque, Ivo
  • Mont, Lluís
  • Hernández-Romero, Ismael
[EN] Introduction: Atrial arrhythmias management remains a significant challenge in cardiac electrophysiology. Cardiac digital twins (CDTs) offer a promising solution for individualized treatment. However, existing models are limited by invasive input requirements or long computational times. This paper introduces DYNAMO, a framework that leverages non-invasive electrocardiographic imaging (ECGI) to create CDTs. Methods: DYNAMO utilizes a reaction-diffusion automata model, reducing computational demands while capturing personalized cardiac dynamics using ECGI data. The calibration process maps ECGI data into CDTs by extracting key parameters for personalization, specifically LATs and conduction velocities. The framework was validated against detailed models and patient data in sinus rhythm (SR) and atrial flutter (AFl), comparing local activation times (LATs) and body surface potential maps (BSPM) for models, and focusing on BSPM for patients. Results: In-silico and clinical validation demonstrated the effectiveness of the framework. CDTs closely replicated cardiac dynamics, with an average LAT difference of 3.8 ms for SR models and 8.03 ms for AFl. For patients, CDTs achieved a high BSPM cross-correlation, with values averaging 0.89 for SR and 0.75 for AFl, and successfully replicated the ablation outcome in an AFl scenario. The framework also demonstrated superior computational efficiency compared to traditional models for equivalent simulations. Conclusions: DYNAMO represents a significant advancement in personalized cardiac health management. Using non-invasive ECGI to create CDTs offers an efficient approach to cardiac modeling. Its capability to simulate treatment strategies holds promise for improving clinical outcomes in atrial arrhythmia management. This study lays the basis for the broader application of ECGI in personalized medicine., This work was supported by the Generalitat Valenciana Grants (ACIF/2021/205, CIBEFP/2022/9, CIAPOS/2021/238, CIGE/2022/02, CIAICO/2022/020) and by ESF Invest in your future. This work was supported by MCIN/AEI/10.13039/501100011033 grants PID2020- 119364RB-I00, RYC2018-024346-I, CNS2022-135512, CPP2021- 008562, PTQ2023-013018, PTQ2023-012972 and by European Union NextGenerationEU/PRTR and by FEDER Fondo Europeo de Desarrollo Regional. This research has received funding from the European Institute of Innovation and Technology (EIT) under grant agreements No 220385 and 250027. This European body receives support from the Horizon 2020 research and innovation programme.