Pasar al contenido principal

Gemelos digitales cardíacos personalizados para mejorar el desarrollo de dispositivos médicos y tratamientos antiarrítmicos cardíacos (DIDIMO)

PLEC2021-007614

•
Nombre agencia financiadora Agencia Estatal de Investigación
Acrónimo agencia financiadora AEI
Programa Programa Estatal de I+D+i Orientado a los Retos de la Sociedad
Convocatoria Proyectos de I+D+i en Líneas Estratégicas
Año convocatoria 2021
Plan Estatal 2017-2020 Plan Estatal de Investigación Científica y Técnica y de Innovación
Centro beneficiario UNIVERSITAT POLITÈCNICA DE VALÈNCIA

Resultados relacionados

Resultados totales (Incluyendo duplicados): 7
Encontrada(s) 1 página(s)

RiuNet. Repositorio Institucional de la Universitat Politécnica de Valéncia
Publicación Artículo científico (JournalArticle)

Electrocardiographic Imaging: A New Tool to Ensure Cardiac Resynchronization During Left Bundle Branch Pacing Implant

  • Pujol-López, Margarida
  • Regany-Closa, Mariona
  • Pellicer-Sendra, Berta
  • Martínez-Pérez, Marta
  • Molero, Ruben
  • Graterol, Freddy R.
  • Guasch, Eduard
  • Tolosana, José M.
  • Mont, Lluís
  • Guillem Sánchez, María Salud|||0000-0001-5660-3693
[EN] Left bundle branch pacing (LBBP) has emerged as an alternative to biventricular pacing for cardiac resynchronization therapy (CRT). The objective is to pursue and ensure resynchronization. However, LBBP capture could fail to achieve adequate resynchronization in some patients, in whom biventricular pacing should be attempted., M.P.-L. is currently funded (2023-2025) through a Rio Hortega contract CM22/00107 [Instituto de Salud Carlos III (ISCIII); Fondo Social Europeo(FSE)]. J.M.T. and M.P.-L. received funding for Project in Conduction System Pacing (FIS PI21/00615) from Instituto de Salud Carlos III (Madrid, Spain). L.M.was funded by a 2021 Support for Research Groups grant from the Catalan government (2021_SGR_01350, SGR21/GENCAT), Catalonia, Spain. J.M.T., L.M.,M.R.-C., M.P.-L., and M.S.G. were funded by "La Marato de TV3 Fundacio", project: 202335 10, Barcelona, Catalonia, Spain. The authors thank the CERCAProgramme/Generalitat de Catalunya for the support to Institut d'Investigacions Biomediques August Pi i Sunyer (IDIBAPS). M.S.G and M.M.-P were funded byEIT Health and H2020 Grant n & zcaron; 230129. R.M. was funded by PTQ2023-012972 and CPP2021-008562 (CARE-ECGI). B.P.-S and M.S.G were supported byPLEC2021-007614 funded by MCIN/AEI/10.13039/501100011033 and EU NextGenerationEU/PRTR. This publication is part of the CPP2021-008562 CARE-ECGIproject -Cardiac resynchronization therapy based on electrocardiographic imaging-, funded by MCIN/AEI/10.13039/501100011033 and by the European Union"NextGenerationEU/PRTR".
RiuNet. Repositorio Institucional de la Universitat Politécnica de Valéncia
Publicación Artículo científico (JournalArticle)

Modeling heart flow dynamics using numerical simulations to identify the vortex ring: A practical guide

  • Lazpita, Eneko
  • Garicano-Mena, Jesús
  • Le clainche, Soledad
  • Mares-Bou, Andrea|||0000-0002-3720-6710
  • Quintero-Igeño, Pedro-Manuel|||0000-0003-4373-2079
[EN] In this study, we present a comprehensive numerical analysis of blood flow within human left ventricle models, with particular emphasis on optimizing simulation conditions to enhance the realism and computational efficiency of heart flow dynamics. The objective is to determine the most effective mesh configurations, flow conditions, and boundary settings necessary for accurately capturing the formation and behavior of the vortex ring¿a pivotal element in ventricular flow dynamics. Utilizing a computational fluid mechanics approach, we review the influence of both idealized and patient-specific geometries on simulation outcomes. It is imperative to consider the necessity of dynamic wall motion and the precise calibration of inlet and outlet boundary conditions, which must be designed to mimic physiological conditions as accurately as possible. These factors are of paramount importance in achieving a balance between computational resource demands and the fidelity of the simulations, thereby providing valuable insights for future cardiovascular modeling efforts. Tutorials explaining details of the simulations and the codes used are included in ModelFLOWs-app website, The authors acknowledge the grants TED2021-129774B-C21 and PLEC2022-009235 funded by MCIN/AEI/10.13039/501100011033 and by the European Union NextGenerationEU /PRTR and the grant PID2023-147790OB-I00 funded by MCIU/AEI/10.13039/ 501100011033/FEDER, UE. The authors gratefully acknowledge the Universidad Politécnica de Madrid (www.upm.es) for providing computing resources on Magerit Supercomputer. P.Q. would like to acknowledge the support of DIDIMO, Grant PLEC2021-007614 funded by MCIN/AEI/10.13039/501100011033 and, as appropriate, by the ERDF A way of making Europe , and the European Union NextGenerationEU/PRTR
RiuNet. Repositorio Institucional de la Universitat Politécnica de Valéncia
Publicación Artículo científico (JournalArticle)

A cyclical fast iterative method for simulating reentries in cardiac electrophysiology using an eikonal-based model

  • Barrios Espinosa, Cristian
  • Appel, Stephanie
  • Becker, Silvia
  • Krauss, Jonathan
  • Martinez Díaz, Patricia
  • Unger, Laura
  • Houillon, Marie
  • Loewe, Axel
  • Sánchez-Arciniegas, Jorge Patricio
[EN] Computer models for simulating cardiac electrophysiology are valuable tools for research and clinical applications. Traditional reaction¿difusion (RD) models used for these purposes are computationally expensive. While eikonal models ofer a faster alternative, they are not well-suited to study cardiac arrhythmias driven by reentrant activity. The present work extends the difusion¿reaction eikonal alternant model (DREAM), incorporating conduction velocity (CV) restitution for simulating complex cardiac arrhythmias. The DREAM modifes the fast iterative method to model cyclical behavior, dynamic boundary conditions, and frequency-dependent anisotropic CV. Additionally, the model alternates with an approximated RD model, using a detailed ionic model for the reaction term and a triple-Gaussian to approximate the difusion term. The DREAM and monodomain models were compared, simulating reentries in 2D manifolds with diferent resolutions. The DREAM produced similar results across all resolutions, while experiments with the monodomain model failed at lower resolutions. CV restitution curves obtained using the DREAM closely approximated those produced by the monodomain simulations. Reentry in 2D sheets yielded similar results in vulnerable window and mean reentry duration for low CV in both models. In the left atrium, most inducing points identifed by the DREAM were also present in the high-resolution monodomain model. DREAM¿s reentry simulations on meshes with an average edge length of 1600 ¿m were 87x faster than monodomain simulations at 200 ¿m. This work establishes the mathematical foundation for using the accelerated DREAM simulation method for cardiac electrophysiology. Cardiac research applications are enabled by a publicly available implementation in the openCARP simulator, This work was supported from the European Union s Horizon research and Innovation programme under the Marie Sklodowska-Curie grant agreement No. 860974, by the Leibniz ScienceCampus Digital Transformation of Research with funds from the programme Strategic Networking in the Leibniz Association , the European High-Performance Computing Joint Undertaking EuroHPC under grant agreement No 955495 (MICROCARD) co-funded by the Horizon 2020 programme of the European Union (EU) and the German Federal Ministry of Education and Research (BMBF), by the Deutsche Forschungsgemeinschaft (DFG, German Research Foundation)-Project-ID 258734477-SFB 1173 and LO 2093/6-1 (SPP 2311) and-Project-ID 394433254 (LU 2294/1-1, DO 637/23-1, WA 4259/1-1), and by the MCIN\AEI and the European Union NextGenerationEU\ RTR under grant PLEC2021-007614.
RiuNet. Repositorio Institucional de la Universitat Politécnica de Valéncia
Publicación Artículo científico (JournalArticle)

Hemocompatibility and hemodynamic comparison of two centrifugal LVADs: HVAD and HeartMate3

  • Gil, A.|||0000-0001-7192-6992
  • Navarro, Roberto|||0000-0003-2587-4954
  • Quintero-Igeño, Pedro-Manuel|||0000-0003-4373-2079
  • Mares-Bou, Andrea|||0000-0002-3720-6710
[EN] Mechanical circulatory support using ventricular assist devices is a common technique for treating patients suffering from advanced heart failure. The latest generation of devices is characterized by centrifugal turbopumps which employ magnetic levitation bearings to ensure a gap clearance between moving and static parts. Despite the increasing use of these devices as a destination therapy, several long-term complications still exist regarding their hemocompatibility. The blood damage associated with different pump designs has been investigated profoundly in the literature, while the hemodynamic performance has been hardly considered. This work presents a novel comparison between the two main devices of the latest generation-HVAD and HM3-from both perspectives, hemodynamic performance and blood damage. Computational fluid dynamics simulations are performed to model the considered LVADs, and computational results are compared to experimental measurements of pressure head to validate the model. Enhanced performance and hemocompatibility are detected for HM3 owing to its design incorporating more conventional blades and larger gap clearances., Open Access funding provided thanks to the CRUE-CSIC agreement with Springer Nature.
RiuNet. Repositorio Institucional de la Universitat Politécnica de Valéncia
Publicación Artículo científico (JournalArticle)

Robustness of imageless electrocardiographic imaging against uncertainty in atrial morphology and location

  • Molero-Alabau, Rubén
  • González-Ascaso, Ana
  • Andreu M. Climent|||0000-0002-7260-8811
  • Guillem Sánchez, María Salud|||0000-0001-5660-3693
[EN] Introduction: Electrocardiographic Imaging is a non-invasive technique that requires cardiac Imaging for the reconstruction of cardiac electrical activity. In this study, we explored imageless ECGI by quantifying the errors of using heart meshes with either an inaccurate location inside the thorax or an inaccurate geometry. Methods: Multiple-lead body surface recordings of 25 atrial fibrillation (AF) patients were recorded. Cardiac atrial meshes were obtained by segmentation of medical images obtained for each patient. ECGI was computed with each patient's segmented atrial mesh and compared with the ECGI obtained under errors in the atrial mesh used for ECGI estimation. We modeled both the uncertainty in the location of the atria inside the thorax by artificially translating the atria inside the thorax and the geometry of the atrial mesh by using an atrial mesh in a reference database. ECGI signals obtained with the actual meshes and the translated or estimated meshes were compared in terms of their correlation coefficients, relative difference measurement star, and errors in the dominant frequency (DF) estimation in epicardial nodes.Results: CC between ECGI signals obtained after translating the actual atrial meshes from the original position by 1 cm was above 0.97. CC between ECGIs obtained with patient specific atrial geometry and estimated atrial geometries was 0.93 +/- 0.11. Mean errors in DF estimation using an estimated atrial mesh were 7.6 +/- 5.9%.Conclusion: Imageless ECGI can provide a robust estimation of cardiac electrophysiological parameters such as activation rates even during complex arrhythmias. Furthermore, it can allow more widespread use of ECGI in clinical practice., This work was supported by: Instituto de Salud Carlos III, and Ministerio de Ciencia e Innovacion (supported by FEDER Fondo Europeo de Desarrollo Regional DIDIMO PLEC2021-007614, ESSENCE PID2020-119364RB-I00, and RYC2018-024346-I) , EIT Health (Activity code SAVE-COR 220385, EIT Health is supported by EIT, a body of the Eu-ropean Union) and Generalitat Valenciana Conselleria d'Educacio, Investigacio, Cultura i Esport (ACIF/2020/265) . The authors want to thank the organizers of the 2022 meeting of the International Society for Computerized Electrocardiology for their invitation to the meeting.
RiuNet. Repositorio Institucional de la Universitat Politécnica de Valéncia
Publicación Artículo científico (JournalArticle)

Enhancing premature ventricular contraction localization through electrocardiographic imaging and cardiac digital twins

  • Sánchez-Arciniegas, Jorge Patricio
  • Llorente-Lipe, Inés|||0009-0005-3386-0407
  • Guillem Sánchez, María Salud|||0000-0001-5660-3693
  • Barrios Espinosa, Cristian
  • Loewe, Axel
  • Hernández-Romero, Ismael
  • Vicente, Jorge
  • Ros, Santiago
  • Atienza, Felipe
  • Carta-Bergaz, Alejandro
  • Climent, Andreu M.
[EN] Premature ventricular contractions (PVCs) represent a common and clinically significant cardiac arrhythmia, contributing to a spectrum of cardiovascular disorders. Accurate localization of the origin of PVCs is essential for devising targeted therapeutic strategies and refining our comprehension of ventricular arrhythmogenesis. Traditionally, the 12-lead ECG has been the go-to diagnostic tool for PVCs. However, individual anatomical differences and inter-patient electrophysiology variability limit its effectiveness. This study presents a new method that combines electrocardiographic imaging (ECGI) with the concept of cardiac digital twins (ECGIDT) to improve the accuracy of pinpointing the source of PVCs. By simulating a database of PVCs, we developed an ECGI-DT capable of estimating the origins of PVCs with much greater precision than possible previously. This study shows a notable improvement in identifying the initial site of PVC origin using ECGI-DT compared to ECGI alone: the average localization error dropped from 30.69 ± 23.71 mm with standard ECGI to 7.81 ± 3.82 mm using the ECGI-DT method. This marked reduction in error highlights the potential of ECGI-DT in revolutionizing PVC diagnosis and treatment. With its ability to provide more accurate and reliable data, ECGI-DT could improve the planning of catheter ablation treatments, a preferred intervention for managing PVCs that face challenges such as high costs and in some cases long procedure times., This work was supported by grants PLEC2021-007614 funded by MCIN, Spain∕AEI∕10.13039∕501100011033 and by European Union NextGenerationEU∕PRTR . This was supported by grant RYC2018-024346-I and by ESF Investing in your future, Spain . This project has received funding from the European Union s Horizon 2020 research and innovation programme under the Marie Skłodowska-Curie grant agreement No. 860974. This work was supported by the Leibniz ScienceCampus, Germany Digital Transformation of Research with funds from the programme Strategic Networking in the Leibniz Association . This research was supported by Deutsche Forschungsgemeinschaft, Germany (DFG, German Research Foundation) under grant LO 2093/9-1.
RiuNet. Repositorio Institucional de la Universitat Politécnica de Valéncia
Publicación Tesis doctoral (DoctoralThesis)

Estimation of Atrial Electrical Complexity during Atrial Fibrillation by Solving the Inverse Problem of Electrocardiography

  • Molero Alabau, Rubén
[ES] La fibrilación auricular (FA) es la arritmia más prevalente en el mundo y está asociada con una elevada morbilidad, mortalidad y costes sanitarios. A pesar de los avances en opciones de tratamiento farmacológico y terapia de ablación, el manejo de la FA todavía tiene margen de mejora. La imagen electrocardiográfica (ECGI) se ha destacado como un prometedor método no invasivo para evaluar la electrofisiología cardíaca y guiar las decisiones terapéuticas en casos de fibrilación auricular. No obstante, el ECGI se enfrenta a desafíos como la necesidad de resolver de manera precisa el denominado problema inverso de la electrocardiografía y de optimizar la calidad de las reconstrucciones de ECGI. Además, la integración del ECGI en los procesos clínicos rutinarios sigue siendo un reto, en gran medida debido a los costos que supone la necesidad de imágenes cardíacas. Por ello, los objetivos principales de esta tesis doctoral son impulsar la tecnología ECGI mediante la determinación de sus requisitos técnicos mínimos y la mejora de las metodologías existentes para obtener señales de ECGI precisas. Asimismo, buscamos evaluar la capacidad de ECGI para cuantificar de forma no invasiva la complejidad de la FA. Para lograr estos objetivos, se han llevado a cabo diversos estudios a lo largo de la tesis, desde el perfeccionamiento del ECGI hasta la evaluación de la FA utilizando esta tecnología. En primer lugar, se han estudiado los requisitos geométricos y de señal del problema inverso mediante el estudio de los efectos de la densidad de la malla del torso y la distribución de electrodos en la precisión del ECGI, lo que ha conducido a la identificación del número mínimo de nodos y su distribución en la malla del torso. Además, hemos identificado que para obtener señales de ECGI de alta calidad, es crucial la correcta disposición de los electrodos en la malla del torso reconstruido. Asimismo, se ha definido y evaluado una nueva metodología de ECGI sin necesidad de usar técnicas de imagen cardiaca. Para ello, hemos comparado métricas derivadas del ECGI calculadas con la geometría original del corazón de los pacientes con las métricas medidas en diferentes geometrías cardíacas. Nuestros resultados han mostrado que el ECGI sin necesidad de imágenes cardíacas es efectivo para la correcta cuantificación y localización de los patrones y zonas que mantienen la FA. En paralelo, hemos optimizado la regularización de Tikhonov de orden cero actual y la optimización de la curva L para el cálculo de las señales ECGI, investigando cómo el ruido eléctrico y las incertidumbres geométricas influyen en la regularización. A partir de ello, propusimos un nuevo criterio que realza la precisión de las soluciones de ECGI en escenarios con incertidumbre debido a condiciones de señal no ideales. En segundo lugar, en esta tesis doctoral, se han llevado a cabo múltiples análisis relativos a diferentes metodologías de procesado de señales y obtención métricas derivadas del ECGI con el fin de caracterizar mejor el sustrato cardíaco y la actividad reentrante en las señales de ECGI de pacientes con FA. Con el objetivo de obtener una comprensión más profunda de los mecanismos electrofisiológicos subyacentes a la FA, hemos establecido la estrategia de filtrado óptima para extraer patrones reentrantes específicos del paciente y métricas derivadas de señales ECGI. Además, hemos investigado la reproducibilidad de los mapas de reentradas derivados de las señales de ECGI y hemos encontrado su relación con el éxito de la ablación de venas pulmonares (PVI). Nuestros resultados han mostrado que una mayor reproducibilidad en los patrones reentrantes de FA detectados con ECGI está relacionada con el éxito de la PVI, creando una metodología para estratificar a los pacientes con FA antes de los procedimientos de ablación., [CA] La fibril·lació auricular (FA) és l'arrítmia més prevalent al món i està associada amb una elevada morbiditat, mortalitat i costos sanitaris. Malgrat els avanços en opcions de tractament farmacològic i teràpies d'ablació, el maneig de la FA encara té marge de millora. La imatge electrocardiogràfica (ECGI) s'ha destacat com un prometedor mètode no invasiu per a avaluar l'electrofisiologia cardíaca i guiar les decisions terapèutiques en casos de fibril·lació auricular. No obstant això, l'ECGI s'enfronta a desafiaments com la necessitat de resoldre de manera precisa el denominat problema invers de la electrocardiografia i d'optimitzar la qualitat de les reconstruccions de ECGI. A més, la integració del ECGI en els processos clínics rutinaris continua sent un repte, en gran manera a causa dels costos que suposa la necessitat d'imatges cardíaques. Per això, els objectius principals d'aquesta tesi doctoral són impulsar la tecnologia de l'ECGI mitjançant la determinació dels seus requisits tècnics mínims i la millora de les metodologies existents per obtenir senyals d'ECGI precises. A més, busquem avaluar la capacitat de l'ECGI per quantificar de forma no invasiva la complexitat de la FA. Per a aconseguir aquests objectius, s'han dut a terme diversos estudis al llarg de la tesi, des del perfeccionament de l'ECGI fins a l'avaluació de la FA utilitzant aquesta tecnologia. En primer lloc, hem estudiat els requisits geomètrics i de senyal del problema invers mitjançant l'estudi dels efectes de la densitat de la malla del tors i la distribució d'elèctrodes en la precisió de l'ECGI, el que ha conduït a la identificació del nombre mínim de nodes i la seva distribució en la malla del tors. A més, hem identificat que per obtindre senyals d'ECGI d'alta qualitat, és crucial la correcta disposició dels elèctrodes en la malla del tors reconstruïda. També s'ha definit i avaluat una nova metodologia d'ECGI sense necessitat d'utilitzar tècniques d'imatge cardíaca. Per a això, hem comparat mètriques derivades de l'ECGI calculades amb la geometria original del cor dels pacients amb les mètriques mesurades en diferents geometries cardíaques. Els nostres resultats han mostrat que l'ECGI sense necessitat d'imatges cardíaques és efectiu per a la correcta quantificació i localització dels patrons i zones que mantenen la FA. Paral·lelament, hem optimitzat la regularització de Tikhonov d'ordre zero actual i l'optimització de la corba L per al càlcul de les senyals d'ECGI, investigant com el soroll elèctric i les incerteses geomètriques influeixen en la regularització. Addicionalment, vam proposar un nou criteri que reforça la precisió de les solucions d'ECGI en escenaris amb incertesa degut a condicions de senyal no ideals. En segon lloc, en aquesta tesi doctoral, s'han dut a terme múltiples anàlisis relatius a diferents metodologies de processament de senyals i obtenció de mètriques derivades de l'ECGI amb l'objectiu de caracteritzar millor el substrat cardíac i l'activitat reentrant en les senyals d'ECGI de pacients amb FA. Amb l'objectiu d'obtindre una comprensió més profunda dels mecanismes electrofisiològics subjacents a la FA, hem establert l'estratègia de filtrat òptima per extreure patrons reentrants específics del pacient i mètriques derivades de senyals ECGI. A més, hem investigat la reproductibilitat dels mapes de reentrades derivats de les senyals d'ECGI i hem trobat la seva relació amb l'èxit de l'ablació de venes pulmonars (PVI). Els nostres resultats han mostrat que una major reproductibilitat en els patrons reentrants de FA detectats amb ECGI està relacionada amb l'èxit de la PVI, creant una metodologia per estratificar els pacients amb FA abans dels procediments d'ablació., [EN] Atrial fibrillation (AF) is the most prevalent arrhythmia in the world and is associated with significant morbidity, mortality, and healthcare costs. Despite advancements in pharmaceutical treatment alternatives and ablation therapy, AF management remains suboptimal. Electrocardiographic Imaging (ECGI) has emerged as a promising non-invasive method for assessing cardiac electrophysiology and guiding therapeutic decisions in atrial fibrillation. However, ECGI faces challenges in dealing with accurately resolving the ill-posed inverse problem of electrocardiography and optimizing the quality of ECGI reconstructions. Additionally, the integration of ECGI into clinical workflows is still a challenge that is hindered by the associated costs arising from the need for cardiac imaging. For this purpose, the main objectives of this PhD thesis are to advance ECGI technology by determining the minimal technical requirements and refining existing methodologies for acquiring accurate ECGI signals. In addition, we aim to assess the capacity of ECGI for noninvasively quantifying AF complexity. To fulfill these objectives, several studies were developed throughout the thesis, advancing from ECGI enhancement to AF evaluation using ECGI. Firstly, geometric and signal requirements of the inverse problem were addressed by studying the effects of torso mesh density and electrode distribution on ECGI accuracy, leading to the identification of the minimal number of nodes and their distribution on the torso mesh. Besides, we identified that the correct location of the electrodes on the reconstructed torso mesh is critical for the accurate ECGI signal obtention. Additionally, a new methodology of imageless ECGI was defined and assessed by comparing ECGI-derived drivers computed with the original heart geometry of the patients to the drivers measured in different heart geometries. Our results showed the ability of imageless ECGI to the correct quantification and location of atrial fibrillation drivers, validating the use of ECGI without the need for cardiac imaging. Also, the current state of-the-art zero-order Tikhonov regularization and L-curve optimization for computing ECGI signals were improved by investigating the impact of electrical noise and geometrical uncertainties on the regularization. We proposed a new criterion that enhances the accuracy and reliability of ECGI solutions in situations with uncertainty from unfavorable signal conditions. Secondly, in this PhD thesis, several analyses, signal processing methodologies, and ECGIderived metrics were investigated to better characterize the cardiac substrate and reentrant activity in ECGI signals from AF patients. With the objective of obtaining a deeper understanding of the electrophysiological mechanisms underlying AF, we established the optimal filtering strategy to extract patient-specific reentrant patterns and derived metrics in ECGI signals. Furthermore, we investigated the reproducibility of the obtained ECGI-reentrant maps and linked them to the success of PVI ablation. Our results showed that higher reproducibility on AF drivers detected with ECGI is linked with the success of PVI, creating a proof-of-concept mechanism for stratifying AF patients prior to ablation procedures., This work was supported by: Instituto de Salud Carlos III, and Ministerio de Ciencia e Innovación (supported by FEDER Fondo Europeo de Desarrollo Regional DIDIMO PLEC2021- 007614, ESSENCE PID2020-119364RB-I00, and RYC2018- 024346B-750), EIT Health (Activity code SAVE-COR 220385, EIT Health is supported by EIT, a body of the European Union) and Generalitat Valenciana Conselleria d’Educació, Investigació, Cultura i Esport (ACIF/2020/265 and BEFPI/2021/062).