Pasar al contenido principal

Resultados relacionados

Resultados totales (Incluyendo duplicados): 2
Encontrada(s) 1 página(s)

DIGITAL.CSIC. Repositorio Institucional del CSIC
Publicación Artículo científico (JournalArticle)

The AX-PET demonstrator - Design, construction and characterization

  • Beltrame, P.
  • Bolle, E.
  • Braem, A.
  • Casella, C.
  • Chesi, E.
  • Clinthorne, N.
  • De Leo, R.
  • Dissertori, G.
  • Djambazov, L.
  • Fanti, V.
  • Heller, M.
  • Joram, C.
  • Kagan, H.
  • Lustermann, W.
  • Meddi, F.
  • Nappi, E.
  • Nessi-Tedaldi, F.
  • Oliver, Josep F.
  • Pauss, F.
  • Rafecas, Magdalena
  • Renker, D.
  • Rudge, A.
  • Schinzel, D.
  • Schneider, T.
  • Séguinot, J.
  • Solevi, P.
  • Stapnes, S.
  • Weilhammer, P.
Axial PET is a novel geometrical concept for Positron Emission Tomography (PET), based on layers of long scintillating crystals axially aligned with the bore axis. The axial coordinate is obtained from arrays of wavelength shifting (WLS) plastic strips placed orthogonally to the crystals. This article describes the design, construction and performance evaluation of a demonstrator set-up which consists of two identical detector modules, used in coincidence. Each module comprises 48 LYSO crystals of 100 mm length and 156 WLS strips. Crystals and strips are readout by Geiger-mode Avalanche Photo Diodes (G-APDs). The signals from the two modules are processed by fully analog front-end electronics and recorded in coincidence by a VME-based data acquisition system. Measurements with point-like <sup>22</sup>Na sources, with the modules used both individually and in coincidence mode, allowed for a complete performance evaluation up to the focal plane reconstruction of point sources. The results obtained are in good agreement with expectations and proved the set-up to be ready for the next evaluation phase with PET phantoms filled with radiotracers. © 2011 Elsevier B.V. All right reserved., The work is partially funded through the Spanish Ministry of Science & Innovation under Grant FPA2008-02419-E and project Grant TEC2007-61047. P. Solevi is supported by the Marie Curie Intra-European Fellowship Grant 237620 for the project INSPET. P. Beltrame is supported through the Marie Curie Initial Training Network MC-PAD (GA no. 214560-2)., No
DIGITAL.CSIC. Repositorio Institucional del CSIC
Publicación Artículo científico (JournalArticle)

Simulated one-pass list-mode: an approach to on-the-fly system matrix calculation

  • Gillam, J. E.
  • Solevi, P.
  • Oliver, Josep F.
  • Rafecas, Magdalena
In the development of prototype systems for positron emission tomography a valid and robust image reconstruction algorithm is required. However, prototypes often employ novel detector and system geometries which may change rapidly under optimization. In addition, developing systems generally produce highly granular, or possibly continuous detection domains which require some level of on-the-fly calculation for retention of measurement precision. In this investigation a new method of on-the-fly system matrix calculation is proposed that provides advantages in application to such list-mode systems in terms of flexibility in system modeling. The new method is easily adaptable to complicated system geometries and available computational resources. Detection uncertainty models are used as random number generators to produce ensembles of possible photon trajectories at image reconstruction time for each datum in the measurement list. However, the result of this approach is that the system matrix elements change at each iteration in a non-repetitive manner. The resulting algorithm is considered the simulation of a one-pass list (SOPL) which is generated and the list traversed during image reconstruction. SOPL alters the system matrix in use at each iteration and so behavior within the maximum likelihood-expectation maximization algorithm was investigated. A two-pixel system and a small two dimensional imaging model are used to illustrate the process and quantify aspects of the algorithm. The two-dimensional imaging system showed that, while incurring a penalty in image resolution, in comparison to a non-random equal-computation counterpart, SOPL provides much enhanced noise properties. In addition, enhancement in system matrix quality is straightforward (by increasing the number of samples in the ensemble) so that the resolution penalty can be recovered when desired while retaining improvement in noise properties. Finally the approach is tested and validated against a standard (highly accurate) system matrix using experimental data from a prototype system--the AX-PET., JG is supported by a ‘Juan de la Cierva’ contract (The Spanish Ministry of Economy and Competitiveness). PS was supported by Marie Curie IEF grant 237620 through the European Commission. JFO was supported by the JAE-Doc modality of the program ‘Junta para la Ampliación de Estudios’, co-financed by FSE. The work was supported by both the European Union and The Spanish Ministry of Economy and Competitiveness through grant number FPA2010-14891., Peer reviewed