CALIDAD DE IMAGEN Y CUANTIFICACION EN TOMOGRAFIA POR EMISION DE POSITRONES

FPA2010-14891

•
Nombre agencia financiadora Ministerio de Ciencia e Innovación
Acrónimo agencia financiadora MICINN
Programa Programa Nacional de Proyectos de Investigación Fundamental
Subprograma Subprograma de Proyectos de Investigación Fundamental no Orientada
Convocatoria Proyectos I+D
Año convocatoria 2010
Plan Estatal 2008-2011 Plan Nacional de Investigación Científica, Desarrollo e Innovación Tecnológica
Unidad de gestión Subdirección General de Proyectos de Investigación
Centro beneficiario UNIVERSITAT DE VALÈNCIA
Identificador persistente http://dx.doi.org/10.13039/501100004837

Resultados relacionados

Resultados totales (Incluyendo duplicados): 6
Encontrada(s) 1 página(s)

RiuNet. Repositorio Institucional de la Universitat Politécnica de Valéncia
Publicación Artículo científico (JournalArticle)

First Images of a Three-layer compton Telescope prototype for Treatment Monitoring in hadron Therapy

  • Llosá, Gabriela
  • Trovato, Marco
  • Etxebeste, Ane
  • Muñoz, Enrique
  • Lacasta, C.
  • Rafecas, Magdalena
  • Solaz, Carles
  • Solevi, Paola
  • Barrio-Toala, John|||0000-0001-5181-2146
  • Oliver-Guillén, José Francisco|||0000-0002-8585-9345
[EN] A Compton telescope for dose monitoring in hadron therapy is under development at IFIC. The system consists of three layers of LaBr3 crystals coupled to silicon photomulti-plier arrays. Na-22 sources have been successfully imaged reconstructing the data with an ML-EM code. Calibration and temperature stabilization are necessary for the prototype operation at low coincidence rates. A spatial resolution of 7.8 mm FWHM has been obtained in the first imaging tests., This work was supported in part by the European Commissions 7th Framework Programme through the ENVISION (G. A. num 241851) project and the Marie Curie ITN ENTERVISION (G. A. num 264552), by the Spanish Ministerio de Economia y Competitividad (FPA2010-14891, FIS2011-14585-E, and FPA2014-53599-R), the UVEG (UV-INV-PRECOMP12-80755), and the Generalitat Valenciana (GV/2013/133 and GVISIC/ 2012/020). Group members are supported by Ramón y Cajal, UVEG Atraccio de Talent, and Generalitat Valenciana contracts.
RiuNet. Repositorio Institucional de la Universitat Politécnica de Valéncia
Publicación Artículo científico (JournalArticle)

First Compton telescope prototype based on continuous LaBr3-SiPM detectors

  • Llosá, G.
  • Cabello, J.
  • Callier, S.
  • Gillam, J.E.
  • Lacasta, C.
  • Rafecas, M.
  • Raux, L.
  • Solaz, C.
  • Stankova, V.
  • de la Taille, C.
  • Trovato, M.
  • Barrio-Toala, John|||0000-0001-5181-2146
[EN] A first prototype of a Compton camera based on continuous scintillator crystals coupled to silicon photomultiplier (SiPM) arrays has been successfully developed and operated. The prototype is made of two detector planes. The first detector is made of a continuous 16 x 18 x 5 mm(3) LaBr3 crystal coupled to a 16-elements SiPM array. The elements have a size of 3 x 3 mm (3) in a 4.5 x 4.05 mm(2) pitch. The second detector, selected by availability, consists of a continuous 16 x 18 x 5 mm(3) LYSO crystal coupled to a similar SiPM array. The SPIROC1 ASIC is employed in the readout electronics. Data have been taken with a Na-22 source placed at different positions and images have been reconstructed with the simulated one-pass list-mode (SOPL) algorithm. Detector development for the construction of a second prototype with three detector planes is underway. LaBr3 crystals of 32 x 36 mm(2) size and 5/10 mm thickness have been acquired and tested with a PMT. The resolution obtained is 3.5% FWHM at 511 keV. Each crystal will be coupled to four MPPC arrays. Different options are being tested for the prototype readout., This work was supported in part by the ENVISION project (Grant Agreement num 241851), and ENTERVISION ITN (Grant Agreement num 264552), funded by the European Commission under FP7, and through a Research project of the Spanish Ministerio de Economia y Competitividad/Plan Nacional de IþDþi (FPA2010-14891). Several group members are supported through the Juan de la Cierva (CSIC), JAE-DOC (CSIC) and Atraccio de Talent (UV) programs.
RiuNet. Repositorio Institucional de la Universitat Politécnica de Valéncia
Publicación Artículo científico (JournalArticle)

High performance detector head for PET and PET/MR with continuous crystals and SiPMs

  • Llosá, G.
  • Barrillon, P.
  • Bisogni, M. G.
  • Cabello, J.
  • Del Guerra, A.
  • Etxebeste, A.
  • Gillam, J.E.
  • Lacasta, C.
  • Rafecas, M.
  • Solaz, C.
  • Stankova, V.
  • de la Taille, C.
  • Barrio-Toala, John|||0000-0001-5181-2146
  • Oliver-Guillén, José Francisco|||0000-0002-8585-9345
[EN] A high resolution PET detector head for small animal PET applications has been developed. The detector is composed of a 12 mm x 12 mm continuous LYSO crystal coupled to a 64-channel monolithic SiPM matrix from FBK-irst. Crystal thicknesses of 5 mm and 10 mm have been tested, both yielding an intrinsic spatial resolution around 0.7 mm FWHM with a position determination algorithm that can also provide depth-of-interaction information. The detectors have been tested in a rotating system that makes it possible to acquire tomographic data and reconstruct images of Na-22 sources. An image reconstruction method specifically adapted for continuous crystals has been employed. The Full Width at Half Maximum measured from a point source reconstructed with ML-EM was 0.7 mm with the 5 mm crystal and 0.8 mm with the 10 mm crystal., This work is partially supported by the European Commission's 7th Framework Programme through a Marie Curie European Reintegration Grant (ASPID GA NUM 239362), and by the Spanish Ministerio de Economia y Competitividad/Plan Nacional de I + D + i Grants TEC2007-61047 and FPA2010-14891. Several group members are supported through the Juan de la Cierva, JAE-DOC and Atraccio de Talent (UV) programs.
RiuNet. Repositorio Institucional de la Universitat Politécnica de Valéncia
Publicación Artículo científico (JournalArticle)

High resolution detectors based on continuous crystals and SiPMs for small animal PET

  • Cabello, J.
  • Barrillon, P.
  • Bisogni, M. G.
  • Del Guerra, A.
  • Lacasta, C.
  • Rafecas, M.
  • Saikouk, H.
  • Solaz, C.
  • Solevi, P.
  • de la Taille, C.
  • Llosá, G.
  • Barrio-Toala, John|||0000-0001-5181-2146
[EN] Sensitivity and spatial resolution are the two main factors to maximize in emission imaging. The improvement of one factor deteriorates the other with pixelated crystals. In this work we combine SiPM matrices with monolithic crystals, using an accurate g-ray interaction position determination algorithm that provides depth of interaction. Continuous crystals provide higher sensitivity than pixelated crystals, while an accurate interaction position determination does not degrade the spatial resolution. Monte Carlo simulations and experimental data show good agreement both demonstrating submillimetre intrinsic spatial resolution. A system consisting in two rotating detectors in coincidence is currently under operation already producing tomographic images., This work is partially supported by the European Commission s 7th Framework Programme through a Marie Curie European Reintegration Grant (ASPID GA NUM 239362), and by the Spanish Ministerio de Ciencia e Innovacio¿n/Plan Nacional de IþDþi Grants TEC2007-61047 and FPA2010-14891. G. Llosa¿ was partly funded by a JAE DOC Grant. H. Saikouk was supported by the Spanish PCI2011 A/035250/11 Project.
RiuNet. Repositorio Institucional de la Universitat Politécnica de Valéncia
Publicación Artículo científico (JournalArticle)

Application of Artificial Neural Network for Reducing Random Coincidences in PET

  • Oliver, J,F.
  • Cabello, J.
  • Tortajada Velert, Salvador
  • Rafecas Lopez, Maria Magdalena
  • Fuster García, Elíes|||0000-0002-0716-8960
Positron Emission Tomography (PET) is based on the detection in coincidence of the two photons created in a positron annihilation. In conventional PET, this coincidence identification is usually carried out through a coincidence electronic unit. An accidental coincidence occurs when two photons arising from different annihilations are classified as a coincidence. Accidental coincidences are one of the main sources of image degradation in PET. Some novel systems allow coincidences to be selected post-acquisition in software, or in real time through a digital coincidence engine in an FPGA. These approaches provide the user with extra flexibility in the sorting process and allow the application of alternative coincidence sorting procedures. In this work a novel sorting procedure based on Artificial Neural Network (ANN) techniques has been developed. It has been compared to a conventional coincidence sorting algorithm based on a time coincidence window. The data have been obtained from Monte-Carlo simulations. A small animal PET scanner has been implemented to this end. The efficiency (the ratio of correct identifications) can be selected for both methods. In one case by changing the actual value of the coincidence window used, and in the other by changing a threshold at the output of the neural network. At matched efficiencies, the ANN-based method always produces a sorted output with a smaller random fraction. In addition, two differential trends are found: the conventional method presents a maximum achievable efficiency, while the ANN-based method is able to increase the efficiency up to unity, the ideal value, at the cost of increasing the random fraction. Images reconstructed using ANN sorted data (no compensation for randoms) present better contrast, and those image features which are more affected by randoms are enhanced. For the image quality phantom used in the paper, the ANN method decreases the spillover ratio by a factor of 18%., This work was supported by RD12/0036/0020 Red Tematica de Investigacion Coperativa en Cancer (RTICC) 2012; Ministerio de Ciencia e Innovacion through a JAE-Doc contract associated to CSIC and FSE co-financed; also under projects TEC-2007-61047 and FPA-2010-14891.
DIGITAL.CSIC. Repositorio Institucional del CSIC
Publicación Artículo científico (JournalArticle)

Simulated one-pass list-mode: an approach to on-the-fly system matrix calculation

  • Gillam, J. E.
  • Solevi, P.
  • Oliver, Josep F.
  • Rafecas, Magdalena
In the development of prototype systems for positron emission tomography a valid and robust image reconstruction algorithm is required. However, prototypes often employ novel detector and system geometries which may change rapidly under optimization. In addition, developing systems generally produce highly granular, or possibly continuous detection domains which require some level of on-the-fly calculation for retention of measurement precision. In this investigation a new method of on-the-fly system matrix calculation is proposed that provides advantages in application to such list-mode systems in terms of flexibility in system modeling. The new method is easily adaptable to complicated system geometries and available computational resources. Detection uncertainty models are used as random number generators to produce ensembles of possible photon trajectories at image reconstruction time for each datum in the measurement list. However, the result of this approach is that the system matrix elements change at each iteration in a non-repetitive manner. The resulting algorithm is considered the simulation of a one-pass list (SOPL) which is generated and the list traversed during image reconstruction. SOPL alters the system matrix in use at each iteration and so behavior within the maximum likelihood-expectation maximization algorithm was investigated. A two-pixel system and a small two dimensional imaging model are used to illustrate the process and quantify aspects of the algorithm. The two-dimensional imaging system showed that, while incurring a penalty in image resolution, in comparison to a non-random equal-computation counterpart, SOPL provides much enhanced noise properties. In addition, enhancement in system matrix quality is straightforward (by increasing the number of samples in the ensemble) so that the resolution penalty can be recovered when desired while retaining improvement in noise properties. Finally the approach is tested and validated against a standard (highly accurate) system matrix using experimental data from a prototype system--the AX-PET., JG is supported by a ‘Juan de la Cierva’ contract (The Spanish Ministry of Economy and Competitiveness). PS was supported by Marie Curie IEF grant 237620 through the European Commission. JFO was supported by the JAE-Doc modality of the program ‘Junta para la Ampliación de Estudios’, co-financed by FSE. The work was supported by both the European Union and The Spanish Ministry of Economy and Competitiveness through grant number FPA2010-14891., Peer reviewed