High performance detector head for PET and PET/MR with continuous crystals and SiPMs

  • Llosá, G.
  • Barrillon, P.
  • Bisogni, M. G.
  • Cabello, J.
  • Del Guerra, A.
  • Etxebeste, A.
  • Gillam, J.E.
  • Lacasta, C.
  • Rafecas, M.
  • Solaz, C.
  • Stankova, V.
  • de la Taille, C.
  • Barrio-Toala, John|||0000-0001-5181-2146
  • Oliver-Guillén, José Francisco|||0000-0002-8585-9345
[EN] A high resolution PET detector head for small animal PET applications has been developed. The detector is composed of a 12 mm x 12 mm continuous LYSO crystal coupled to a 64-channel monolithic SiPM matrix from FBK-irst. Crystal thicknesses of 5 mm and 10 mm have been tested, both yielding an intrinsic spatial resolution around 0.7 mm FWHM with a position determination algorithm that can also provide depth-of-interaction information. The detectors have been tested in a rotating system that makes it possible to acquire tomographic data and reconstruct images of Na-22 sources. An image reconstruction method specifically adapted for continuous crystals has been employed. The Full Width at Half Maximum measured from a point source reconstructed with ML-EM was 0.7 mm with the 5 mm crystal and 0.8 mm with the 10 mm crystal., This work is partially supported by the European Commission's 7th Framework Programme through a Marie Curie European Reintegration Grant (ASPID GA NUM 239362), and by the Spanish Ministerio de Economia y Competitividad/Plan Nacional de I + D + i Grants TEC2007-61047 and FPA2010-14891. Several group members are supported through the Juan de la Cierva, JAE-DOC and Atraccio de Talent (UV) programs.
RiuNet. Repositorio Institucional de la Universitat Politécnica de Valéncia
Publicación Artículo científico (JournalArticle)

High resolution detectors based on continuous crystals and SiPMs for small animal PET

  • Cabello, J.
  • Barrillon, P.
  • Bisogni, M. G.
  • Del Guerra, A.
  • Lacasta, C.
  • Rafecas, M.
  • Saikouk, H.
  • Solaz, C.
  • Solevi, P.
  • de la Taille, C.
  • Llosá, G.
  • Barrio-Toala, John|||0000-0001-5181-2146
[EN] Sensitivity and spatial resolution are the two main factors to maximize in emission imaging. The improvement of one factor deteriorates the other with pixelated crystals. In this work we combine SiPM matrices with monolithic crystals, using an accurate g-ray interaction position determination algorithm that provides depth of interaction. Continuous crystals provide higher sensitivity than pixelated crystals, while an accurate interaction position determination does not degrade the spatial resolution. Monte Carlo simulations and experimental data show good agreement both demonstrating submillimetre intrinsic spatial resolution. A system consisting in two rotating detectors in coincidence is currently under operation already producing tomographic images., This work is partially supported by the European Commission s 7th Framework Programme through a Marie Curie European Reintegration Grant (ASPID GA NUM 239362), and by the Spanish Ministerio de Ciencia e Innovacio¿n/Plan Nacional de IþDþi Grants TEC2007-61047 and FPA2010-14891. G. Llosa¿ was partly funded by a JAE DOC Grant. H. Saikouk was supported by the Spanish PCI2011 A/035250/11 Project.