Pasar al contenido principal

Resultados relacionados

Resultados totales (Incluyendo duplicados): 3
Encontrada(s) 1 página(s)

RiuNet. Repositorio Institucional de la Universitat Politécnica de Valéncia
Publicación Artículo científico (JournalArticle)

First Images of a Three-layer compton Telescope prototype for Treatment Monitoring in hadron Therapy

  • Llosá, Gabriela
  • Trovato, Marco
  • Etxebeste, Ane
  • Muñoz, Enrique
  • Lacasta, C.
  • Rafecas, Magdalena
  • Solaz, Carles
  • Solevi, Paola
  • Barrio-Toala, John|||0000-0001-5181-2146
  • Oliver-Guillén, José Francisco|||0000-0002-8585-9345
[EN] A Compton telescope for dose monitoring in hadron therapy is under development at IFIC. The system consists of three layers of LaBr3 crystals coupled to silicon photomulti-plier arrays. Na-22 sources have been successfully imaged reconstructing the data with an ML-EM code. Calibration and temperature stabilization are necessary for the prototype operation at low coincidence rates. A spatial resolution of 7.8 mm FWHM has been obtained in the first imaging tests., This work was supported in part by the European Commissions 7th Framework Programme through the ENVISION (G. A. num 241851) project and the Marie Curie ITN ENTERVISION (G. A. num 264552), by the Spanish Ministerio de Economia y Competitividad (FPA2010-14891, FIS2011-14585-E, and FPA2014-53599-R), the UVEG (UV-INV-PRECOMP12-80755), and the Generalitat Valenciana (GV/2013/133 and GVISIC/ 2012/020). Group members are supported by Ramón y Cajal, UVEG Atraccio de Talent, and Generalitat Valenciana contracts.
RiuNet. Repositorio Institucional de la Universitat Politécnica de Valéncia
Publicación Artículo científico (JournalArticle)

3D position determination in monolithic crystals coupled to SiPMs for PET

  • Etxebeste, Ane
  • Muñoz, Enrique
  • Solaz, Carles
  • Llosá, Gabriela
  • Barrio-Toala, John|||0000-0001-5181-2146
  • Oliver-Guillén, José Francisco|||0000-0002-8585-9345
[EN] The interest in using continuous monolithic crystals in positron emission tomography (PET) has grown in the last years. Coupled to silicon photomultipliers (SiPMs), the detector can combine high sensitivity and high resolution, the two main factors to be maximized in a positron emission tomograph. In this work, the position determination capability of a detector comprised of a 12 x 12 x 10 mm(3) LYSO crystal coupled to an 8 x 8-pixel array of SiPMs is evaluated. The 3D interaction position of.-rays is estimated using an analytical model of the light distribution including reflections on the facets of the crystal. Monte Carlo simulations have been performed to evaluate different crystal reflectors and geometries. The method has been characterized and applied to different cases. Intrinsic resolution obtained with the position estimation method used in this work, applied to experimental data, achieves sub-millimetre resolution values. Average resolution over the detector surface for 5 mm thick crystal is similar to 0.9 mm FWHM and similar to 1.2 mm FWHM for 10 mm thick crystal. Depth of interaction resolution is close to 2 mm FWHM in both cases, while the FWTM is similar to 5.3 mm for 5 mm thick crystal and similar to 9.6 mm for 10 mm thick crystal., This work was supported in part by the Spanish Ministerio de Economia y Competitividad (FPA2014-53599-R), the UVEG (UV-INV-PRECOMP12-80755) and the Generalitat Valenciana (GV/2013/133 and GVISIC/2012/020). Group members are supported by Ramon y Cajal, UVEG Atraccio de Talent and Generalitat Valenciana contracts.
RiuNet. Repositorio Institucional de la Universitat Politécnica de Valéncia
Publicación Artículo científico (JournalArticle)

Performance of VATA64HDR16 ASIC for medical physics applications based on continuous crystals and SiPMs

  • Barrio-Toala, John|||0000-0001-5181-2146
  • Oliver-Guillén, José Francisco|||0000-0002-8585-9345
  • Etxebeste, A.
  • Lacasta, C.
  • Muñoz, E.
  • Solaz, C.
  • Llosá, G.
[EN] Detectors based on Silicon Photomultipliers (SiPMs) coupled to continuous crystals are being tested in medical physics applications due to their potential high resolution and sensitivity. To cope with the high granularity required for a very good spatial resolution, SiPM matrices with a large amount of elements are needed. To be able to read the information coming from each individual channel, dedicated ASICs are employed. The VATA64HDR16 ASIC is a 64-channel, charge-sensitive amplifier that converts the collected charge into a proportional current or voltage signal. A complete assessment of the suitability of that ASIC for medical physics applications based on continuous crystals and SiPMs has been carried out. The input charge range is linear from 20 pC up to 55 pC. The energy resolution obtained at 511 keV is 10% FWHM with a LaBr3 crystal and 16% FWHM with a LYSO crystal. A coincidence timing resolution of 24 ns FWHM is obtained with two LYSO crystals., This work was supported in part by the European Commission's 7th Framework Programme through the ENVISION project (G. A. num 241851), by the Spanish Ministerio de Economia y Competitividad (FPA2014-53599-R), the UVEG (UV-INV-PRECOMP12-80755) and the Generalitat Valenciana (GV/2013/133 and GVISIC/2012/020). Group members are supported by Ramon y Cajal, UVEG Atraccio de Talent and Generalitat Valenciana contracts.