Proton Radiographs Using Position-Sensitive Silicon Detectors and High-Resolution Scintillators

  • Briz, José Antonio
  • Nerio, A.N.
  • Ballesteros, C.
  • García Borge, María José
  • Martínez, P.
  • Perea, Ángel
  • García Távora, Vicente
  • Tengblad, Olof
  • Clemaia, M.
  • Maj, A.
  • Oiko, P.
  • Parol, W.
  • Pedracka, A.
  • Sowicki, B.
  • Zieblinski, M.
  • Nácher, Enrique
7 pags., 11 figs., 1 tab., Proton therapy is a cancer treatment technique currently in growth since it offers advantages with respect to conventional X-ray and ¿ -ray radiotherapy. In particular, better control of the dose deposition allowing to reach higher conformity in the treatments causing less secondary effects. However, in order to take full advantage of its potential, improvements in treatment planning and dose verification are required. A new prototype of proton computed tomography scanner is proposed to design more accurate and precise treatment plans for proton therapy. Our prototype is formed by double-sided silicon strip detectors and scintillators of LaBr3(Ce) with high energy resolution and fast response. Here, the results obtained from an experiment performed using a 100-MeV proton beam are presented. Proton radiographs of polymethyl methacrylate (PMMA) samples of 50-mm thickness with spatial patterns in aluminum were taken. Their properties were studied, including reproduction of the dimensions, spatial resolution, and sensitivity to different materials. Structures of up to 2 mm are well resolved and the sensitivity of the system was enough to distinguish the thicknesses of 10 mm of aluminum or PMMA. The spatial resolution of the images was 0.3 line pairs per mm (MTF-10%). This constitutes the first step to validate the device as a proton radiography scanner., This work has been supported by the PRONTO-CM B2017/BMD-3888 project funded by Comunidad de Madrid (Spain). The research leading to these results has received funding from the European Union’s Horizon 2020 research and innovation programme under grant agreement no. 654002 (ENSAR2) and grant agreement No [730983] (INSPIRE). This work has been partly supported by the Spanish Funding Agency for Research (AEI) through the PID2019-104390GBI00 and PID2019-104714GB-C21 projects. A.N. Nerio acknowledges the fundings from the Erasmus Mundus Joint Master Degree on Nuclear Physics co-funded by the Erasmus+Programme of the European Union.
DIGITAL.CSIC. Repositorio Institucional del CSIC
Publicación Artículo científico (JournalArticle)

First experimental measurements of 2D microdosimetry maps in proton therapy

  • Guardiola Salmerón, Consuelo
  • Bachiller-Perea, Diana
  • Kole, Emmanuel M Mate
  • Fleta, Celeste
  • Quirion, David
  • De Marzi, Ludovic
  • Gómez, Faustino
Empirical data in proton therapy indicate that relative biological effectiveness (RBE) is not constant, and it is directly related to the linear energy transfer (LET). The experimental assessment of LET with high resolution would be a powerful tool for minimizing the LET hot spots in intensity-modulated proton therapy, RBE- or LET-guided evaluation and optimization to achieve biologically optimized proton plans, verifying the theoretical predictions of variable proton RBE models, and so on. This could impact clinical outcomes by reducing toxicities in organs at risk., Peer reviewed
DIGITAL.CSIC. Repositorio Institucional del CSIC
Publicación Artículo científico (JournalArticle)

Evaluation of water equivalent thicknesses using the IEM-CSIC scanner prototype

  • Nerio, A.N.
  • Briz, José Antonio
  • García Borge, María José
  • Nácher, Enrique
  • Tengblad, Olof
  • Perea, Ángel
  • García Távora, Vicente
4 pags., 7 figs., This work was partially supported by the project Proton Therapy and Nuclear Techniques for Oncology (PRONTO) funded by the local government of Madrid, with reference B2017/BMD-3888; by the Horizon 2020 Research and Innovation Programme of the European Union under Grant 654002 (ENSAR2) and Grant 730983 (INSPIRE). This publication is part of the R&D grants PID2019-104714GB-C21, and PID2019- 104390GB-I00, funded by the Spanish Ministry of Science CIN/AEI/10.13039/501100011033, and grant CIPROM/2021/064 from Generalitat Valenciana. The work of A. N. Nerio was partially supported by the Erasmus Mundus Joint Master Degree in Nuclear Physics cofunded by the Erasmus+ Programme of the European Union., Peer reviewed
DIGITAL.CSIC. Repositorio Institucional del CSIC
Publicación Artículo científico (JournalArticle)

Characterization of a novel proton-CT scanner based on Silicon and LaBr3(Ce) detectors

  • Nácher, Enrique
  • Briz, José Antonio
  • Nerio, A. N.
  • Perea, Ángel
  • García Távora, Vicente
  • Tengblad, Olof
  • Ciemala, M.
  • Cieplicka-Orynczak, N.
  • Maj, A.
  • Mazurek, K.
  • Olko, P.
  • Zieblinski, M.
  • García Borge, María José
9 pags., 8 figs., 1 tab., Treatment planning systems at proton-therapy centres entirely use X-ray computed tomography (CT) as primary imaging technique to infer the proton treatment doses to tumour and healthy tissues. However, proton stopping powers in the body, as derived from X-ray images, suffer from important proton-range uncertainties. In order to reduce this uncertainty in range, one could use proton-CT images instead. The main goal of this work is to test the capabilities of a newly-developed proton-CT scanner, based on the use of a set of tracking detectors and a high energy resolution scintillator for the residual energy of the protons. Different custom-made phantoms were positioned at the field of view of the scanner and were irradiated with protons at the CCB proton-therapy center in Krakow. We measured with the phantoms at different angles and produced sinograms that were used to obtain reconstructed images by Filtered Back-Projection. The obtained images were used to determine the capabilities of our scanner in terms of spatial resolution and proton Relative Stopping Power (RSP) mapping and validate its use as proton-CT scanner. The results show that the scanner can produce medium-high quality images, with spatial resolution better than 2 mm in radiography, below 3 mm in tomography and resolving power in the RSP comparable to other state-of-the-art pCT scanners., This work has been mainly supported by the PRONTO-CM and ASAP-CM projects (Grants B2017/BMD-3888 and P2022/BMD-7434 from Comunidad de Madrid, Spain) that has sponsored J.A. Briz and A.N. Nerio. The experiments have been carried out with the support of the European Union Horizon 2020 research and innovation programme under Grant Agreement No. 654002 (ENSAR2) and Grant Agreement No [730983] (INSPIRE). This publication is also part of the R&D Grants PID2022-140162NB-I00, PID2022-138297NB-C21 and PDC2022-133382-I00, funded by the Spanish Ministry of Science (MCIN/AEI/10.13039/501100011033) and Grant CIPROM/2021/064 from Generalitat Valenciana. Open Access funding provided thanks to the CRUE-CSIC agreement with Springer Nature, Peer reviewed
Dipòsit Digital de Documents de la UAB
Publicación Artículo científico (JournalArticle)

Simulation and experimental verification of ambient neutron doses in a pencil beam scanning proton therapy room as a function of treatment plan parameters

  • Van Hoey, Olivier
  • Stolarczyk, Liliana
  • Lillhök, Jan
  • Eliasson, Linda
  • Mojzeszek, Natalia
  • Liszka, Malgorzata
  • Alkhiat, Ali
  • Mares, Vladimir
  • Trompier, François
  • Trinkl, Sebastian
  • Martínez-Rovira, Immaculada|||0000-0002-2918-489X
  • Romero-Expósito, Maite
  • Domingo, Carles|||0000-0002-8480-692X
  • Ploc, Ondrej
  • Harrison, Roger
  • Olko, Pawel
Out-of-field patient doses in proton therapy are dominated by neutrons. Currently, they are not taken into account by treatment planning systems. There is an increasing need to include out-of-field doses in the dose calculation, especially when treating children, pregnant patients, and patients with implants. In response to this demand, this work presents the first steps towards a tool for the prediction of out-of-field neutron doses in pencil beam scanning proton therapy facilities. As a first step, a general Monte Carlo radiation transport model for simulation of out-of-field neutron doses was set up and successfully verified by comparison of simulated and measured ambient neutron dose equivalent and neutron fluence energy spectra around a solid water phantom irradiated with a variation of different treatment plan parameters. Simulations with the verified model enabled a detailed study of the variation of the neutron ambient dose equivalent with field size, range, modulation width, use of a range shifter, and position inside the treatment room. For future work, it is planned to use this verified model to simulate out-of-field neutron doses inside the phantom and to verify the simulation results by comparison with previous in-phantom measurement campaigns. Eventually, these verified simulations will be used to build a library and a corresponding tool to allow assessment of out-of-field neutron doses at pencil beam scanning proton therapy facilities.
Dipòsit Digital de Documents de la UAB
Publicación Artículo científico (JournalArticle)

Neutron Radiation Dose Measurements in a Scanning Proton Therapy Room, Can Parents Remain Near Their Children During Treatment?

  • Mares, Vladimir
  • Farah, Jad
  • De Saint-Hubert, Marijke
  • Domański, Szymon
  • Domingo, Carles|||0000-0002-8480-692X
  • Dommert, Martin
  • Kłodowska, Magdalena
  • Krzempek, Katarzyna
  • Kuć, Michal
  • Martínez-Rovira, Immaculada|||0000-0002-2918-489X
  • Michaś, Edyta
  • Mojżeszek, Natalia
  • Murawski, Łukasz
  • Ploc, Ondrej
  • Romero-Expósito, Maite
  • Tisi, Marco
  • Trompier, François
  • Van Hoey, Olivier
  • Van Ryckeghem, Laurent
  • Wielunski, Marek
  • Harrison, Roger M.
  • Stolarczyk, Liliana
  • Olko, Pawel
Purpose: This study aims to characterize the neutron radiation field inside a scanning proton therapy treatment room including the impact of different pediatric patient sizes. Materials and Methods: Working Group 9 of the European Radiation Dosimetry Group (EURADOS) has performed a comprehensive measurement campaign to measure neutron ambient dose equivalent, H*(10), at eight different positions around 1-, 5-, and 10-year-old pediatric anthropomorphic phantoms irradiated with a simulated brain tumor treatment. Several active detector systems were used. Results: The neutron dose mapping within the gantry room showed that H*(10) values significantly decreased with distance and angular deviation with respect to the beam axis. A maximum value of about 19.5 µSv/Gy was measured along the beam axis at 1 m from the isocenter for a 10-year-old pediatric phantom at 270° gantry angle. A minimum value of 0.1 µSv/Gy was measured at a distance of 2.25 m perpendicular to the beam axis for a 1-year-old pediatric phantom at 140° gantry angle. The H*(10) dependence on the size of the pediatric patient was observed. At 270° gantry position, the measured neutron H*(10) values for the 10-year-old pediatric phantom were up to 20% higher than those measured for the 5-year-old and up to 410% higher than for the 1-year-old phantom, respectively. Conclusions: Using active neutron detectors, secondary neutron mapping was performed to characterize the neutron field generated during proton therapy of pediatric patients. It is shown that the neutron ambient dose equivalent H*(10) significantly decreases with distance and angle with respect to the beam axis. It is reported that the total neutron exposure of a person staying at a position perpendicular to the beam axis at a distance greater than 2 m from the isocenter remains well below the dose limit of 1 mSv per year for the general public (recommended by the International Commission on Radiological Protection) during the entire treatment course with a target dose of up to 60 Gy. This comprehensive analysis is key for general neutron shielding issues, for example, the safe operation of anesthetic equipment. However, it also enables the evaluation of whether it is safe for parents to remain near their children during treatment to bring them comfort. Currently, radiation protection protocols prohibit the occupancy of the treatment room during beam delivery.