Minerva. Repositorio Institucional de la Universidad de Santiago de Compostela
Publicación Artículo científico (JournalArticle)

Silicon 3D Microdetectors for Microdosimetry in Hadron Therapy

  • Guardiola, Consuelo
  • Fleta, Celeste
  • Quirion, David
  • Pellegrini, Giulio
  • Gómez Rodríguez, Faustino
The present overview describes the evolution of new microdosimeters developed in the National Microelectronics Center in Spain (IMB-CNM, CSIC), ranging from the first ultra-thin 3D diodes (U3DTHINs) to the advanced 3D-cylindrical microdetectors, which have been developed over the last 10 years. In this work, we summarize the design, main manufacture processes, and electrical characterization of these devices. These sensors were specifically customized for use in particle therapy and overcame some of the technological challenges in this domain, namely the low noise capability, well-defined sensitive volume, high spatial resolution, and pile-up robustness. Likewise, both architectures reduce the loss of charge carriers due to trapping effects, the charge collection time, and the voltage required for full depletion compared to planar silicon detectors. In particular, a 3D‒cylindrical architecture with electrodes inserted into the silicon bulk and with a very well‒delimited sensitive volume (SV) mimicked a cell array with shapes and sizes similar to those of mammalian cells for the first time. Experimental tests of the carbon beamlines at the Grand Accélérateur National d’Lourds (GANIL, France) and Centro Nazionale Adroterapia Oncologica (CNAO, Italy) showed the feasibility of the U3DTHINs in hadron therapy beams and the good performance of the 3D‒cylindrical microdetectors for assessing linear energy distributions of clinical beams, with clinical fluence rates of 5 × 107 s−1cm−2 without saturation. The dose-averaged lineal energies showed a generally good agreement with Monte Carlo simulations. The results indicated that these devices can be used to characterize the microdosimetric properties in hadron therapy, even though the charge collection efficiency (CCE) and electronic noise may pose limitations on their performance, which is studied and discussed herein. In the last 3D‒cylindrical microdetector generation, we considerably improved the CCE due to the microfabrication enhancements, which have led to shallower and steeper dopant profiles. We also summarize the successive microdosimetric characterizations performed with both devices in proton and carbon beamlines
Minerva. Repositorio Institucional de la Universidad de Santiago de Compostela
Publicación Artículo científico (JournalArticle)

Characterization of the Charge Collection Efficiency in Silicon 3-D-Detectors for Microdosimetry

  • Bachiller Perea, Diana
  • García López, Javier
  • Jiménez-Ramos, María del Carmen
  • Gómez Rodríguez, Faustino
  • Fleta, Celeste
  • Quirion, David
  • García Osuna, Adrián
  • Guardiola, Consuelo
New silicon 3-D-microdetectors have been developed to perform microdosimetry measurements for applications in hadron therapy. In this work, the charge collection efficiency (CCE) of an improved second generation of microdetectors having two different thicknesses (10 and 20 \mu \text{m} ) and a diameter of 25 \mu \text{m} has been studied by means of the ion beam induced charge (IBIC) technique. New methods to study the active volume and the CCE of microdosimeters are proposed and verified here. The results show that, for this new generation of microdetectors, the CCE is 100% for radial distances up to 10.2 \mu \text{m} from the center of the device, and it rapidly decays between 10.2 \mu \text{m} and the detector edge. The characterization of the CCE conducted here will allow us to completely explain the energy spectra obtained during the microdosimetry studies performed in clinical centers.
DIGITAL.CSIC. Repositorio Institucional del CSIC
Publicación Artículo científico (JournalArticle)

Silicon 3D Microdetectors for Microdosimetry in Hadron Therapy

  • Guardiola Salmerón, Consuelo
  • Fleta, Celeste
  • Quirion, David
  • Pellegrini, Giulio
  • Gómez Rodríguez, Faustino
The present overview describes the evolution of new microdosimeters developed in the National Microelectronics Center in Spain (IMB-CNM, CSIC), ranging from the first ultra-thin 3D diodes (U3DTHINs) to the advanced 3D-cylindrical microdetectors, which have been developed over the last 10 years. In this work, we summarize the design, main manufacture processes, and electrical characterization of these devices. These sensors were specifically customized for use in particle therapy and overcame some of the technological challenges in this domain, namely the low noise capability, well-defined sensitive volume, high spatial resolution, and pile-up robustness. Likewise, both architectures reduce the loss of charge carriers due to trapping effects, the charge collection time, and the voltage required for full depletion compared to planar silicon detectors. In particular, a 3D‒cylindrical architecture with electrodes inserted into the silicon bulk and with a very well‒delimited sensitive volume (SV) mimicked a cell array with shapes and sizes similar to those of mammalian cells for the first time. Experimental tests of the carbon beamlines at the Grand Accélérateur National d’Lourds (GANIL, France) and Centro Nazionale Adroterapia Oncologica (CNAO, Italy) showed the feasibility of the U3DTHINs in hadron therapy beams and the good performance of the 3D‒cylindrical microdetectors for assessing linear energy distributions of clinical beams, with clinical fluence rates of 5 × 10<sup>7</sup> s<sup>−1</sup>cm<sup>−2</sup> without saturation. The dose-averaged lineal energies showed a generally good agreement with Monte Carlo simulations. The results indicated that these devices can be used to characterize the microdosimetric properties in hadron therapy, even though the charge collection efficiency (CCE) and electronic noise may pose limitations on their performance, which is studied and discussed herein. In the last 3D‒cylindrical microdetector generation, we considerably improved the CCE due to the microfabrication enhancements, which have led to shallower and steeper dopant profiles. We also summarize the successive microdosimetric characterizations performed with both devices in proton and carbon beamlines., This work made use of the Spanish ICTS Network (Infraestructuras Científicas y Técnicas Singulares) MICRONANOFABS (Red de Salas Blancas de Micro y Nanofabricación) partially supported by the Spanish Ministry of Science and Innovation, the European Union’s Horizon Research and Innovation Program under the Marie Sklodowska-Curie grant agreement No 745109, the CNRS-Momentum fellow, and the H2020 project AIDA-2020, under grant agreement no. 654168., Peer reviewed
DIGITAL.CSIC. Repositorio Institucional del CSIC
Publicación Artículo científico (JournalArticle)

First experimental measurements of 2D microdosimetry maps in proton therapy

  • Guardiola Salmerón, Consuelo
  • Bachiller-Perea, Diana
  • Kole, Emmanuel M Mate
  • Fleta, Celeste
  • Quirion, David
  • De Marzi, Ludovic
  • Gómez, Faustino
Empirical data in proton therapy indicate that relative biological effectiveness (RBE) is not constant, and it is directly related to the linear energy transfer (LET). The experimental assessment of LET with high resolution would be a powerful tool for minimizing the LET hot spots in intensity-modulated proton therapy, RBE- or LET-guided evaluation and optimization to achieve biologically optimized proton plans, verifying the theoretical predictions of variable proton RBE models, and so on. This could impact clinical outcomes by reducing toxicities in organs at risk., Peer reviewed