UVaDOC. Repositorio Documental de la Universidad de Valladolid
Publicación Artículo científico (JournalArticle)

Corneal Collagen Ordering After In Vivo Rose Bengal and Riboflavin Cross-Linking

  • Germann, James A.
  • Martínez Enríquez, Eduardo
  • Martínez García, María del Carmen
  • Kochevar, Irene E
  • Marcos, Susana
Producción Científica, Purpose: Photoactivated cornea collagen cross-linking (CXL) increases corneal stiffness by initiating formation of covalent bonds between stromal proteins. Because CXL depends on diffusion to distribute the photoinitiator, a gradient of CXL efficiency with depth is expected that may affect the degree of stromal collagen organization. We used second harmonic generation (SHG) microscopy to investigate the differences in stromal collagen organization in rabbit eyes after corneal CXL in vivo as a function of depth and time after surgery. Methods: Rabbit corneas were treated in vivo with either riboflavin/UV radiation (UVX) or Rose Bengal/green light (RGX) and evaluated 1 and 2 months after CXL. Collagen fibers were imaged with a custom-built SHG scanning microscope through the central cornea (350 µm depth, 225 × 225 µm en face images). The order coefficient (OC), a metric for collagen organization, and total SHG signal were computed for each depth and compared between treatments. Results: OC values of CXL-treated corneas were larger than untreated corneas by 27% and 20% after 1 month and 38% and 33% after 2 months for the RGX and UVX, respectively. RGX OC values were larger than UVX OC values by 3% and 5% at 1 and 2 months. The SHG signal was higher in CXL corneas than untreated corneas, both at 1 and 2 months after surgery, by 18% and 26% and 1% and 10% for RGX and UVX, respectively. Conclusions: Increased OC corresponded with increased collagen fiber organization in CXL corneas. Changes in collagen organization parallel reported temporal changes in cornea stiffness after CXL and also, surprisingly, are detected deeper in the stroma than the regions stiffened by collagen cross-links., European Research Council Advanced Grant ERC-2011-AdG Ref. 294099, Spanish Government Grants FIS2014-56643 and FIS2017-84753-R, H2020 Research and Innovation Action H2020-ICT-2017 Ref. 779960.
DIGITAL.CSIC. Repositorio Institucional del CSIC
Publicación Artículo científico (JournalArticle)

Corneal collagen ordering after in vivo Rose Bengal and riboflavin cross-linking

  • Germann, James
  • Martínez-Enríquez, Eduardo
  • Martínez-García, Carmen
  • Kochevar, Irene E.
  • Marcos, Susana
8 pags., 6 figs., PURPOSE. Photoactivated cornea collagen cross-linking (CXL) increases corneal stiffness by initiating formation of covalent bonds between stromal proteins. Because CXL depends on diffusion to distribute the photoinitiator, a gradient of CXL efficiency with depth is expected that may affect the degree of stromal collagen organization. We used second harmonic generation (SHG) microscopy to investigate the differences in stromal collagen organization in rabbit eyes after corneal CXL in vivo as a function of depth and time after surgery. METHODS. Rabbit corneas were treated in vivo with either riboflavin/UV radiation (UVX) or Rose Bengal/green light (RGX) and evaluated 1 and 2 months after CXL. Collagen fibers were imaged with a custom-built SHG scanning microscope through the central cornea (350 μm depth, 225 × 225 μm en face images). The order coefficient (OC), a metric for collagen organization, and total SHG signal were computed for each depth and compared between treatments. RESULTS. OC values of CXL-treated corneas were larger than untreated corneas by 27% and 20% after 1 month and 38% and 33% after 2 months for the RGX and UVX, respectively. RGX OC values were larger than UVX OC values by 3% and 5% at 1 and 2 months. The SHG signal was higher in CXL corneas than untreated corneas, both at 1 and 2 months after surgery, by 18% and 26% and 1% and 10% for RGX and UVX, respectively. CONCLUSIONS. Increased OC corresponded with increased collagen fiber organization in CXL corneas. Changes in collagen organization parallel reported temporal changes in cornea stiffness after CXL and also, surprisingly, are detected deeper in the stroma than the regions stiffened by collagen cross-links., Supported by the European Research Council Advanced Grant ERC-2011-AdG Ref. 294099, Spanish Government Grants FIS2014-56643 and FIS2017-84753-R, H2020 Research and Innovation Action H2020-ICT-2017 Ref. 779960.
DIGITAL.CSIC. Repositorio Institucional del CSIC
Publicación Artículo científico (JournalArticle)

Crystalline lens gradient refractive index distribution in the guinea pig

  • Castro, Alberto de
  • Martínez-Enríquez, Eduardo
  • Pérez Merino, Pablo
  • Velasco Ocaña, Miriam
  • Revuelta, Luis
  • McFadden, Sally A.
  • Marcos, Susana
8 pags., 6 figs., Purpose: The crystalline lens undergoes morphological and functional changes with age and may also play a role in eye emmetropisation. Both the geometry and the gradient index of refraction (GRIN) distribution contribute to the lens optical properties. We studied the lens GRIN in the guinea pig, a common animal model to study myopia. Methods: Lenses were extracted from guinea pigs (Cavia porcellus) at 18 days of age (n = 4, three monolaterally treated with negative lenses and one untreated) and 39 days of age (n = 4, all untreated). Treated eyes were myopic (−2.07 D on average) and untreated eyes hyperopic (+3.3 D), as revealed using streak retinoscopy in the live and cyclopeged animals. A custom 3D spectral domain optical coherence tomography (OCT) system (λ = 840 nm, Δλ = 50 nm) was used to image the enucleated crystalline lens at two orientations. Custom algorithms were used to estimate the lens shape and GRIN was modelled with four variables that were reconstructed using the OCT data and a minimisation algorithm. Ray tracing was used to calculate the optical power and spherical aberration assuming a homogeneous refractive index or the estimated GRIN. Results: Guinea pig lenses exhibited nearly parabolic GRIN profiles. When comparing the two age groups (18- and 39 day-old) there was a significant increase in the central thickness (from 3.61 to 3.74 mm), and in the refractive index of the surface (from 1.362 to 1.366) and the nucleus (from 1.443 to 1.454). The presence of GRIN shifted the spherical aberration (−4.1 µm on average) of the lens towards negative values. Conclusions: The guinea pig lens exhibits a GRIN profile with surface and nucleus refractive indices that increase slightly during the first days of life. GRIN plays a major role in the lens optical properties and should be incorporated into computational guinea pig eye models to study emmetropisation, myopia development and ageing., This work was supported by European Research Council (ERC) Grant Agreement ERC-2011-AdC- 294099; ERC under the European Union’s Horizon 2020 research and innovation programme (H2020-MSCA COFUND-2015 FP-713694, MULTIPLY) and under grant agreement No 779960, IMCUSTOMEYE and No 675137 (MyFUun MSCA ITN); Spanish Government Grant FIS2017-84753-R; Hunter Medical Research Institute G1400967 and the University of Newcastle (FVG 1031537 and SSP).
DIGITAL.CSIC. Repositorio Institucional del CSIC
Publicación Artículo científico (JournalArticle)

Multi-meridian corneal imaging of air-puff induced deformation for improved detection of biomechanical abnormalities

  • Curatolo, Andrea
  • Birkenfeld, Judith S.
  • Martínez-Enríquez, Eduardo
  • Germann, James
  • Muralidharan, Geethika
  • Palací, J.
  • Pascual, Daniel
  • Eliasy, A.
  • Abass, A.
  • Solarski, J.
  • Karnowski, K.
  • Wojtkowski, M.
  • Elsheikh, A.
  • Marcos, Susana
19 pags., 10 figs., 2 tabs., Corneal biomechanics play a fundamental role in the genesis and progression of corneal pathologies, such as keratoconus; in corneal remodeling after corneal surgery; and in affecting the measurement accuracy of glaucoma biomarkers, such as the intraocular pressure (IOP). Air-puff induced corneal deformation imaging reveals information highlighting normal and pathological corneal response to a non-contact mechanical excitation. However, current commercial systems are limited to monitoring corneal deformation only on one corneal meridian. Here, we present a novel custom-developed swept-source optical coherence tomography (SSOCT) system, coupled with a collinear air-puff excitation, capable of acquiring dynamic corneal deformation on multiple meridians. Backed by numerical simulations of corneal deformations, we propose two different scan patterns, aided by low coil impedance galvanometric scan mirrors that permit an appropriate compromise between temporal and spatial sampling of the corneal deformation profiles. We customized the air-puff module to provide an unobstructed SSOCT field of view and different peak pressures, air-puff durations, and distances to the eye. We acquired multi-meridian corneal deformation profiles (a) in healthy human eyes in vivo, (b) in porcine eyes ex vivo under varying controlled IOP, and (c) in a keratoconus-mimicking porcine eye ex vivo. We detected deformation asymmetries, as predicted by numerical simulations, otherwise missed on a single meridian that will substantially aid in corneal biomechanics diagnostics and pathology screening., Horizon 2020 Framework Programme (666295, 713694, 779960); Ministerio de Economía, Industria y Competitividad, Gobierno de España (FJC2018-038736-I); Fundacja na rzecz Nauki Polskiej (MAB/2019/12).
DIGITAL.CSIC. Repositorio Institucional del CSIC
Publicación Contribución de congreso (ConferenceOutput)

Detecting deformation asymmetries on multiple meridians in an ex vivo keratoconic eye model

  • Curatolo, Andrea
  • Birkenfeld, Judith S.
  • Martínez-Enríquez, Eduardo
  • Germann, James
  • Palací, J.
  • Pascual, Daniel
  • Muralidharan, Geethika
  • Eliasy, A.
  • Abass, A.
  • Solarski, J.
  • Karnowski, Karol
  • Wojtkowski, Maciej
  • Elsheikh, A.
  • Marcos, Susana
1 pag. -- This is a 2020 ARVO Annual Meeting abstract., Support European Project COFUND Multiply H-2020-MSCA-COFUND-2015 Ref. 713694; European Project IMCUSTOMEYE H2020-ICT-2017 Ref. 779960; European Project MyFUN H2020-MSCA-ITN-2015 Ref. 675137; Spanish government grant FIS2017-84753-R, Peer reviewed
DIGITAL.CSIC. Repositorio Institucional del CSIC
Publicación Contribución de congreso (ConferenceOutput)

3D OCT-based geometrical changes of human crystalline lenses during simulated accommodation in a lens stretcher

  • Martínez-Enríquez, Eduardo
  • Castro, Alberto de
  • Mohamed, Ashik
  • Maceo Heilman, B.
  • Williams, S.
  • Nandyala, S.
  • Ruggeri, Marco
  • Parel, J. M. A.
  • Augusteyn, Robert
  • Ho, Arthur
  • Manns, Fabrice
  • Marcos, Susana
This is a 2020 ARVO Annual Meeting abstract., Support European Project MyFUN H2020-MSCA-ITN-2015 Ref. 675137, European Project IMCUSTOMEYE H2020-ICT-2017 Ref. 779960​, European Project SILKEYE H2020-ERC-2018-ADG Ref. 833106, European Project COFUND Multiply H-2020-MSCA-COFUND-2015 Ref. 713694, Spanish government grant FIS2017-84753-R, NEI Grants: R01EY021834, F31EY021444 (Maceo), P30EY14801 (Center Grant); the Florida Lions Eye Bank; Research to Prevent Blindness; Drs. KR Olsen and ME Hildebrandt, Drs. Raksha Urs and Aaron Furtado, the Henri and Flore Lesieur Foundation (JMP); Hyderabad Eye Research Foundation., Peer reviewed
DIGITAL.CSIC. Repositorio Institucional del CSIC
Publicación Artículo científico (JournalArticle)

Isolated human crystalline lens three-dimensional shape: A comparison between Indian and European populations

  • Mohamed, Ashik
  • Nandyala, S.
  • Martínez-Enríquez, Eduardo
  • Maceo Heilman, B.
  • Augusteyn, Robert
  • Castro, Alberto de
  • Ruggeri, Marco
  • Parel, J. M. A.
  • Marcos, Susana
  • Manns, Fabrice
6 pags., 2 figs., 2 tabs., There have been many studies on lens properties in specific populations (e.g. in China, Europe, Singapore, etc.) some of which suggest there may be differences between populations. Differences could be caused by ethnic or environmental influences or experimental procedures. The purpose of this study is to evaluate if any differences exist between Indian and European populations in the central geometric and full shape properties of human lenses. Two custom-developed spectral domain optical coherence tomography systems were used to acquire the crystalline lens geometry: one in India (69 lenses from 59 donors) and the other in Spain (24 lenses from 19 donors). The steps for obtaining accurate 3-D models from optical coherence tomography raw images comprised of image segmentation, fan and optical distortion correction, tilt removal and registration. The outcome variables were lens equatorial diameter, lens thickness, anterior and posterior lens thicknesses and their ratio, central radius of curvature of the anterior and posterior lens surfaces, lens volume and lens surface area. A mixed effects model by maximum likelihood estimation was used to evaluate the effect of age, population and their interaction (age*population) on lens parameters. After adjusting for age, there were no population differences observed in anterior and posterior radii of curvature, equatorial diameter, lens thickness, anterior and posterior lens thicknesses and their ratio, volume and surface area (all p ≥ 0.08). There was also no effect of the interaction term on anterior and posterior radii of curvature, equatorial diameter, lens thickness, anterior and posterior lens thicknesses and their ratio, volume and surface area (all p ≥ 0.06). All central geometric and full shape parameters appeared to be comparable between the European and Indian populations. This is the first study to compare geometric and full shape lens parameters between different populations in vitro., This work was supported by the National Institutes of Health/National Eye Institute [Grants 2R01EY021834 and P30EY14801 (Center Grant)]; the Hyderabad Eye Research Foundation; Ministerio de Educacion y Ciencia, Spain (FIS2017- 84753-R), European Research Council (ERC-2018-AdG-833106) and IMCUSTOMEYE Ref. 779960 (H2020- ICT- 2017-1) to S. Marcos, and European Research Council (ERC) under European Union’s Horizon 2020 research and innovation programme H2020-MSCA COFUND-2015 FP-713694, MULTIPLY(AdC), CSIC ICoop Program, Florida Lions Eye Bank and the Beauty of Sight Foundation, an unrestricted grant from Research to Prevent Blindness to the Department of Ophthalmology, University of Miami and the Henri and Flore Lesieur Foundation (J-M. Parel).
DIGITAL.CSIC. Repositorio Institucional del CSIC
Publicación Artículo científico (JournalArticle)

Vision with spatial light modulator simulating multifocal contact lenses in an adaptive optics system

  • Vedhakrishnan, Shrilekha
  • Viñas, María
  • Aissati, Sara
  • Marcos, Susana
14 pags., 7 figs., 1 tab., Visual simulators are useful tools to provide patients experience of multifocal vision prior to treatment. In this study, commercially available center-near aspheric multifocal contact lenses (MCLs) of low, medium, and high additions were mapped on a spatial light modulator (SLM) and validated on a bench. Through focus visual acuity (TFVA) was measured in subjects through the SLM and real MCLs on the eye. A correlation metric revealed statistically significant shape similarity between TFVA curves with real and simulated MCLs. A Bland-Altman analysis showed differences within confidence intervals of ±0.01 logMAR for LowAdd/MediumAdd and ±0.06 logMAR for HighAdd. Visual performance with simulated MCLs outperformed real MCLs by ∼20%. In conclusion, SLM captures the profile of center-near MCLs and reproduces vision with real MCLs, revealing that the MCL profile and its interactions with the eye’s optics (and not fitting aspects) account for the majority of the contributions to visual performance with MCLs, This research has received funding from the European Union’s Horizon 2020 Research and Innovation Program, MyFun under the Marie Sklodowska-Curie grant agreement to SV, and H2020-MSCA-IF-GF2019-MYOMICRO-893557 to MV, under the Marie Sklodowska-Curie grant agreement; European Research Council ERC-2019-AdG-833106 H2020 Innovative Action 779960 & Spanish Government FIS2017-84753-R to SM., Peer reviewed
DIGITAL.CSIC. Repositorio Institucional del CSIC
Publicación Contribución de congreso (ConferenceOutput)

Detecting deformation asymmetries on multiple meridians in an ex vivo keratoconic eye model

  • Curatolo, Andrea
  • Birkenfeld, Judith S.
  • Martínez-Enríquez, Eduardo
  • Germann, James
  • Palací, J.
  • Pascual, Daniel
  • Muralidharan, Geethika
  • Eliasy, A.
  • Abass, A.
  • Solarski, J.
  • Karnowski, Karol
  • Wojtkowski, Maciej
  • Elsheikh, A.
  • Marcos, Susana
ARVO Annual Meeting Abstract, Support European Project COFUND Multiply H-2020-MSCA-COFUND-2015 Ref. 713694; European Project IMCUSTOMEYE H2020-ICT-2017 Ref. 779960; European Project MyFUN H2020-MSCA-ITN-2015 Ref. 675137; Spanish government grant FIS2017-84753-R, Peer reviewed
DIGITAL.CSIC. Repositorio Institucional del CSIC
Publicación Contribución de congreso (ConferenceOutput)

Assessment of asymmetries in biomechanical properties from corneal deformation imaging

  • Birkenfeld, Judith S.
  • Germann, James
  • Castro, Alberto de
  • Hoz, A. de la
  • Curatolo, Andrea
  • Marcos, Susana
This abstract was presented at the 2019 ARVO Annual Meeting, held in Vancouver, Canada, April 28 - May 2, 2019, Support European Project Multiply H-2020-MSCA-COFUND-2015 Ref. 713694, Spanish Government Grant FIS2017-84753-R, European Project Presbyopia ERC-2011-AdG Ref. 294099, European Project Imcustomeye H2020-ICT-2017 Ref. 779960, BES-2015-072197, Peer reviewed
DIGITAL.CSIC. Repositorio Institucional del CSIC
Publicación Artículo científico (JournalArticle)

Optical Evaluation of Intracorneal Ring Segment Surgery in Keratoconus

  • Alejandre, Nicolas
  • Pérez Merino, Pablo
  • Velarde, Gonzalo
  • Jiménez-Alfaro, Ignacio
  • Marcos, Susana
13 pags., 2 figs., 5 tabs., The purpose of this study was to assess the impact of different intracorneal ring segments (ICRS) combinations on corneal morphology and visual performance on patients with keratoconus., Funding from Horizon 2020 Framework Programme European Project Imcustomeye (H2020- ICT-2017 Ref. 779960); S. Marcos, NEI, NIH P30 EY001319 and an Unrestricted Grant to the University of Rochester Department of Ophthalmology from Research to Prevent Blindness,, Peer reviewed
DIGITAL.CSIC. Repositorio Institucional del CSIC
Publicación Artículo científico (JournalArticle)

Visual simulations of presbyopic corrections through cataract opacification

  • Barcala, Xoana
  • Zaytouny, Amal
  • Rego-Lorca, Daniela
  • Sanchez-Quiros, Julia
  • Sanchez-Jean, Ruben
  • Martinez de la Casa, Jose Maria
  • Dorronsoro, Carlos
  • Marcos, Susana
29 pags., To study the viability of visual simulation of presbyopic corrections in patients with cataract, the effect and impact of the cataract on the perceived visual quality of the different simulated presbyopic corrections pre- and post-operatively., This research was supported by Madrid Regional Government IND2017/BMD7670 to XB; IMCUSTOMEYE Ref. 779960 H2020 - EU.2.1.1. Industrial Leadership to SM; SILK-EYE Ref. 833106 Excellent Science – ERC to SM; Spanish Government Grant FIS2017-84753-R to SM; and ISCIII DTS16/00127 to CD., Peer reviewed
DIGITAL.CSIC. Repositorio Institucional del CSIC
Publicación Artículo científico (JournalArticle)

Multifocal contact lens vision simulated with a clinical binocular simulator

  • Barcala, Xoana
  • Viñas, María
  • Ruiz, Sofia
  • Hidalgo, Fernando
  • Nankivil, Derek
  • Karkkainen, Tom
  • Gambra, Enrique
  • Dorronsoro, Carlos
  • Marcos, Susana
11 pags., 10 figs., 2 tabs., The purpose of this study is to compare the binocular visual perception of participants wearing multifocal contact lenses and these same lens designs viewed through a temporal multiplexing visual simulator., This research has received funding from the European Research Council under the IMCUSTOMEYE Ref. 779,960 H2020 - EU.2.1.1. Industrial Leadership to SM; SILK-EYE Ref. 833,106 Excellent Science – ERC to SM; and the H2020-MSCA-IF-GF-2019-MYOMICRO-893557 to MV. National Eye Institute P30 Core Grant EY001319-46 (Center for Visual Science) and Unrestricted grant Research to Prevent Blindness (Flaum Eye Institute) to SM. This research was supported also from the Spanish Government under the Spanish Government Grant FIS2017-84753-R to SM, and ISCIII DTS16/00127 to CD; Madrid Regional Government IND2017/BMD7670 to XB; and Master Clinical Research Agreement between Johnson and Johnson Vision Care (USA), 2EyesVision, Centro Boston de Optometría and IO-CISC., Peer reviewed
DIGITAL.CSIC. Repositorio Institucional del CSIC
Publicación Artículo científico (JournalArticle)

Accommodation through simulated multifocal optics

  • Vedhakrishnan, Shrilekha
  • Castro, Alberto de
  • Viñas, María
  • Aissati, Sara
  • Marcos, Susana
16 pags., 7 figs., We evaluated the interaction of multifocal patterns with eye's accommodation. Seven patterns were mapped on the spatial light modulator and the deformable mirror of an adaptive optics visual simulator, and projected onto the subjects' eyes, representing different contact lens designs: NoLens, Bifocal Center Distance (+2.50D), Bifocal Center Near (+2.50D) and Multifocal Center Near-MediumAdd (+1.75D) and Center Near HighAdd (+2.50D), positive and negative spherical aberration (±1µm). The change in spherical aberration and the accommodative response to accommodative demands were obtained from Hartmann-Shack measurements. Positive spherical aberration and Center Distance designs are consistent with a higher accommodative response (p=0.001 & p=0.003): steeper shift of SA towards negative values and lower accommodative lag., Marie Sklodowska-Curie (ADC, H2020-MSCA-IF-GF-2019-MYOMICRO-893557, SV, PID2020-115191); European Research Council (ERC-2019-AdG-833106 H2020); Innovative Action (779960); Spanish Government (FIS2017-84753-R, NIH P30, RPB unrestricted funds to SM), Peer reviewed
DIGITAL.CSIC. Repositorio Institucional del CSIC
Publicación Artículo científico (JournalArticle)

Estimation of the full shape of the crystalline lens in-vivo from OCT images using eigenlenses

  • Martínez-Enríquez, Eduardo
  • Curatolo, Andrea
  • Castro, Alberto de
  • Birkenfeld, Judith S.
  • González-Ramos, Ana M.
  • Mohamed, Ashik
  • Ruggeri, Marco
  • Manns, Fabrice
  • Fernando, Zvietcovich
  • Marcos, Susana
19 pags., 9 figs., 5 tabs., Quantifying the full 3-D shape of the human crystalline lens is important for improving intraocular lens power or sizing calculations in treatments of cataract and presbyopia. In a previous work we described a novel method for the representation of the full shape of the ex vivo crystalline lens called eigenlenses, which proved more compact and accurate than compared state-of-the art methods of crystalline lens shape quantification. Here we demonstrate the use of eigenlenses to estimate the full shape of the crystalline lens in vivo from optical coherence tomography images, where only the information visible through the pupil is available. We compare the performance of eigenlenses with previous methods of full crystalline lens shape estimation, and demonstrate an improvement in repeatability, robustness and use of computational resources. We found that eigenlenses can be used to describe efficiently the crystalline lens full shape changes with accommodation and refractive error., HORIZON EUROPE European Research Council (IMCUSTOMEYE H2020-ICT-2017 Ref. 779960;); European Research Council (SILKEYE H2020-ERC-571 2018-ADG Ref.833106); Ministerio de Ciencia e Innovación (PID2020-115191RB-I00); Narodowa Agencja Wymiany Akademickiej (ULAM 2020/1/00176); Fundacja narzecz Nauki Polskiej (MAB/2019/12); L’Oréal-UNESCO “For Women in Science”; Ministerio de Ciencia, Innovación y Universidades (IJC2018-037508-I, Juan de la Cierva-Incorporation); Research to Prevent Blindness (Bascom Palmer Eye Institute, Flaum Eye Institute); National Institutes of Health (NIE P30EY 001319); Unrestricted Funds Research to Prevent Blindness, NY; National Institutes of Health (R01EY021834); National Institutes of Health (P30EY014801); Florida Lions Eye Bank and Beauty of Sight Foundation; Hyderabad Eye Research Foundation., Peer reviewed
DIGITAL.CSIC. Repositorio Institucional del CSIC
Publicación Artículo científico (JournalArticle)

Estimation of the full shape of the crystalline lens from OCT: validation using stretched donor lenses

  • Martínez-Enríquez, Eduardo
  • Maceo Heilman, Bianca
  • Castro, Alberto de
  • Mohamed, Ashik
  • Ruggeri, Marco
  • Zvietcovich, Fernando
  • Manns, Fabrice
  • Marcos, Susana
16 pags., 6 figs., 2 tabs., Quantifying human crystalline lens geometry as a function of age and accommodation is important for improved cataract and presbyopia treatments. In previous works we presented eigenlenses as a basis of 3-D functions to represent the full shape of the crystalline lens ex vivo. Also, we presented the application of eigenlenses to estimate the full shape of the lens in vivo from 3-D optical coherence tomography (OCT) images, where only the central part of the lens -visible through the pupil- is available. The current work presents a validation of the use of eigenlenses to estimate in vivo the full shape of dis-accommodated lenses. We used 14 ex vivo crystalline lenses from donor eyes (11-54 y/o) mounted in a lens stretcher, and measured the geometry and the power of the lenses using a combined OCT and ray tracing aberrometry system. Ex vivo, the full extent of the lens is accessible from OCT because the incident light is not blocked by the iris. We measured in non-stretched (fully accommodated) and stretched (mimicking in vivo dis-accommodated lenses) conditions. Then, we simulated computationally in vivo conditions on the obtained ex vivo lenses geometry (assuming that just the portion of the lens within a given pupil is available), and estimated the full shape using eigenlenses. The mean absolute error (MAE) between estimated and measured lens' diameters and volumes were MAE = 0.26 ± 0.18 mm and MAE = 7.0 ± 4.5 mm3, respectively. Furthermore, we concluded that the estimation error between measured and estimated lenses did not depend on the accommodative state (change in power due to stretching), and thus eigenlenses are also useful for the full shape estimation of in vivo dis-accommodated lenses., European Project IMCUSTOMEYE H2020-ICT-2017 Ref. 779960; European Project SILKEYE H2020- ERC-2018-ADG Ref. 833106; Spanish government grant PID2020-115191RB-I00; NIH grants P30; Research to Prevent Blindness Departmental Funds to Flaum Eye Insitute and Bascom Palmer Eye Institute; NIE P30EY 001319; Unrestricted Funds to Research to Prevent Blindness, NY; National Institutes of Health Center Core Grant (R01EY021834); Florida Lions Eye Bank and Beauty of Sight Foundation; Hyderabad Eye Research Foundation., Peer reviewed
DIGITAL.CSIC. Repositorio Institucional del CSIC
Publicación Artículo científico (JournalArticle)

Poster Session: Estimation of scleral biomechanical properties from air-puff-coupled optical coherence tomography

  • Birkenfeld, Judith S.
  • Villegas, Lupe
  • Hoz, A. de la
  • Bronte-Ciriza, David
  • Varea, Alejandra
  • Martínez-Enríquez, Eduardo
  • Curatolo, Andrea
  • Germann, James
  • Marcos, Susana
Optica Fall Vision Meeting Abstract, Progression of myopia is usually accompanied by axial overgrowth of the eyeball, which affects scleral biomechanics (BM). To study scleral biomechanics, we propose the use of air-puff deformation swept-source OCT imaging. Air-puff deformation imaging was performed at different sites of ex vivo porcine (n=5) and rabbit (n=3) eyes, (<24hr postmortem): Nasal/temporal equatorial and posterior sclera (NE, NP, TE, TP), superior (S) and inferior (I) sclera, and cornea (C). Intraocular pressure was kept at 15mmHg. Deformation data were used as input to inverse finite element model (FEM) algorithms to reconstruct BM properties. Experimental deformation amplitudes showed dependence on the animal model, with porcine scleras exhibiting greater inter-site variation (displacement of S, I was up to four times greater than that of N, T), while rabbit scleras exhibited at most 40% of displacement differences between all sites. Both models showed significant (p<.001) differences in the temporal deformation profile between sclera and (C), but similarities in all scleral locations, suggesting that the scleral temporal profile is independent of scleral thickness variations. The FEM estimated an elastic modulus of 1.84 ± 0.30 MPa (I) to 6.04 ± 2.11 MPa (TE) for the porcine sclera. The use of scleral air-puff imaging is promising for noninvasive investigation of structural changes in the sclera associated with myopia and for monitoring possible modulation of scleral stiffness with myopia treatment., Funding: Horizon 2020 Framework Programme European Project Imcustomeye (H2020-ICT-2017 Ref. 779960); European Research Council (2018-ADG-SILKEYE-833106); Spanish Government 10.13039/100014440 (CSIC JAE Intro Fellowship); L'Oréal-UNESCO “For Women in Science” Spain; Spanish Government Juan de la Cierva-Incorporation Fellowship (IJC2018-037508-I); Spanish Government PID2020-115191RB-I00; Fundacja na rzecz Nauki Polskiej (MAB/2019/12); National Agency for Academic Exchange, Polish Government (NAWA ULAM/2020/1/00176); NIH NIE P30EY 001319; Unrestricted Funds Research to Prevent Blindness, NY, Peer reviewed
DIGITAL.CSIC. Repositorio Institucional del CSIC
Publicación Artículo científico (JournalArticle)

Poster Session: Experimental assessment of scleral anisotropy using multi-meridian air-coupled ultrasonic optical coherence elastography

  • Villegas, Lupe
  • Zvietcovich, Fernando
  • Varea, Alejandra
  • Curatolo, Andrea
  • Birkenfeld, Judith S.
  • Marcos, Susana
Optica Fall Vision Meeting Abstract, September 2023, Scleral biomechanics plays a key role in the understanding of myopia progression. In this study, we characterized the elastic properties of sclera using an air-coupled ultrasonic (ACUS) optical coherence elastography (OCE) system. New Zealand rabbit eyes (n=7) were measured (<24hr postmortem) in four scleral locations: superior/inferior temporal (ST, IT), and superior/inferior nasal (SN, IN) maintaining an intraocular pressure of 15 mmHg. Elastic waves were induced in the sclera, and wave propagation velocity and shear modulus were measured along two directions: circumferential (superior-inferior) and meridional (nasal-temporal). Wave velocity in scleral tissue ranged from 6 to 24 m/s and shear modulus from 11 to 150 kPa. Velocity was significantly higher (p<.001) in the circumferential vs. meridional directions in the following locations: ST:15.83±2.85 vs 9.43±1.68 m/s, IT:15.00±3.98 vs 8.93±1.53 m/s; SN:16.79±4.30 vs 9.27±1.47 m/s; and IN:13.92±3.85 vs 8.57±1.46 m/s. The average shear modulus in the circumferential was also significantly higher (p<.001) than in the meridional direction for all locations: 65.37±6.04 vs 22.55±1.36 kPa. These results show that the rabbit sclera is mechanically anisotropic with higher rigidity in the circumferential direction compared to the meridional direction. ACUS-OCE is a promising non-invasive method to quantify the biomechanical changes in scleral tissue for future studies involving myopia treatments., Funding: Funding: Horizon 2020 Framework Programme European Project Imcustomeye (H2020-ICT-2017 Ref. 779960); European Research Council (2018-ADG-SILKEYE-833106); Spanish Government PID2020-115191RB-I00; NIH NIE P30EY 001319; Unrestricted Funds Research to Prevent Blindness, NY; Spanish Government10.13039/100014440 (CSIC JAE Intro Fellowship); L'Oréal-UNESCO “For Women in Science” Spain; Spanish Government Juan de la Cierva-Incorporation Fellowship (IJC2018-037508-I); Fundacja na rzecz Nauki Polskiej (MAB/2019/12); National Agency for Academic Exchange, Polish Government (NAWA ULAM/2020/1/00176), Peer reviewed
DIGITAL.CSIC. Repositorio Institucional del CSIC
Publicación Artículo científico (JournalArticle)

Effect of fixational eye movements in corneal topography measurements with optical coherence tomography

  • Castro, Alberto de
  • Martínez-Enríquez, Eduardo
  • Marcos, Susana
15 pags., 7 figs., 1 tab., here is an increasing interest in applying optical coherence tomography (OCT) to quantify the topography of ocular structures. However, in its most usual configuration, OCT data is acquired sequentially while a beam is scanned through the region of interest, and the presence of fixational eye movements can affect the accuracy of the technique. Several scan patterns and motion correction algorithms have been proposed to minimize this effect, but there is no consensus on the ideal parameters to obtain a correct topography. We have acquired corneal OCT images with raster and radial patterns, and modeled the data acquisition in the presence of eye movements. The simulations replicate the experimental variability in shape (radius of curvature and Zernike polynomials), corneal power, astigmatism, and calculated wavefront aberrations. The variability of the Zernike modes is highly dependent on the scan pattern, with higher variability in the direction of the slow scan axis. The model can be a useful tool to design motion correction algorithms and to determine the variability with different scan patterns., Agencia Estatal de Investigación (FIS2017-84753-R, PID2020-115191RB-I00); European Research Council (H2020-ICT-2017 Ref.779960); National Institutes of Health (P30EY 001319,Unrestricted Funds to Research to Prevent Blindness).
DIGITAL.CSIC. Repositorio Institucional del CSIC
Publicación Artículo científico (JournalArticle)

Revealing regional variations in scleral shear modulus in a rabbit eye model using multi-directional ultrasound optical coherence elastography

  • Villegas, Lupe
  • Zvietcovich, Fernando
  • Marcos, Susana
  • Birkenfeld, Judith S.
12 pags., 7 figs., The mechanical properties of the sclera play a critical role in supporting the ocular structure and maintaining its shape. However, non-invasive measurements to quantify scleral biomechanics remain challenging. Recently introduced multi-directional optical coherence elastography (OCE) combined with an air-coupled ultrasound transducer for excitation of elastic surface waves was used to estimate phase speed and shear modulus in ex vivo rabbit globes (n = 7). The scleral phase speed (12.1 ± 3.2 m/s) was directional-dependent and higher than for corneal tissue (5.9 ± 1.4 m/s). In the tested locations, the sclera proved to be more anisotropic than the cornea by a factor of 11 in the maximum of modified planar anisotropy coefficient. The scleral shear moduli, estimated using a modified Rayleigh-Lamb wave model, showed significantly higher values in the circumferential direction (65.4 ± 31.9 kPa) than in meridional (22.5 ± 7.2 kPa); and in the anterior zone (27.3 ± 9.3 kPa) than in the posterior zone (17.8 ± 7.4 kPa). The multi-directional scanning approach allowed both quantification and radial mapping of estimated parameters within a single measurement. The results indicate that multi-directional OCE provides a valuable non-invasive assessment of scleral tissue properties that may be useful in the development of improved ocular models, the evaluation of potential myopia treatment strategies, and disease characterization and monitoring., Open Access funding provided thanks to the CRUE-CSIC agreement with Springer Nature. This work has been funded by Spanish Government Grant (PRE2018-086169, FIS2017-84753-R, PID2020-115191RB-I00); European Project H2020 IMCUSTOMEYE (779960); European Research Council (2018-ADG-SILKEYE-833106); Ayudas Ramón y Cajal (RYC2022-037910-I); L’Oréal-UNESCO “For Women in Science” Spain; NIH NEI P30EY 001319; Unrestricted Funds Research to Prevent Blindness., Peer reviewed
DIGITAL.CSIC. Repositorio Institucional del CSIC
Publicación Artículo científico (JournalArticle)

A simple computational model for scleral stiffness assessments via air-puff deformation OCT

  • Hoz, A. de la
  • Villegas, Lupe
  • Marcos, Susana
  • Birkenfeld, Judith S.
13 pags., 11 figs., 2 tabs., Introduction: The mechanical properties of the sclera are related to its structural function, and changes to these properties are believed to contribute to pathologies such as myopia. Air-puff deformation imaging is a tool that uses an imaging system coupled with an air-puff excitation source to induce and measure deformation in a tissue in vivo. Typically used for the study of the cornea's mechanical properties and IOP, this tool has been proposed as a method to evaluate scleral stiffness. Methods: In this work, we present a computational model of the rabbit eye to assess scleral deformation under air-puff. Parametric studies were conducted to evaluate the effects of material properties, intraocular pressure, and other parameters on the deformation response. Output from the model was also compared to experimental measurements of air-puff deformation in rabbit eyes under varying IOP. Results: Central deformation response was found to be most influenced by material properties of the sclera (at site of air-puff and posterior), thickness, and IOP, whereas deformation profile was most influenced by material properties. Experimental and simulated IOP dependence were found to be similar (RMSE = 0.13 mm). Discussion: Scleral APDI could be a useful tool for quick in vivo assessment of scleral stiffness., The author(s) declare that financial support was received for the research, authorship, and/or publication of this article. Spanish Government Grant (PRE2018-086169, FIS2017-84753-R, PID2020115191RB-I00); European Project H2020 IMCUSTOMEYE (779960); European Research Council (2018-ADG-SILKEYE833106); Ayudas Ramón y Cajal (RYC2022-037910-I); L’OréalUNESCO “For Women in Science” Spain; NIH NEI P30EY 001319; Unrestricted Funds Research to Prevent Blindness, NY, Peer reviewed
DIGITAL.CSIC. Repositorio Institucional del CSIC
Publicación Artículo científico (JournalArticle)

Estimation of scleral mechanical properties from air-puff optical coherence tomography

  • Bronte-Ciriza, David
  • Birkenfeld, Judith S.
  • Hoz, A. de la
  • Curatolo, Andrea
  • Germann, James
  • Villegas, Lupe
  • Varea, Alejandra
  • Martínez-Enríquez, Eduardo
  • Marcos, Susana
19 pages, 7 figures, 2 tables, We introduce a method to estimate the biomechanical properties of the porcine sclera in intact eye globes ex vivo, using optical coherence tomography that is coupled with an air-puff excitation source, and inverse optimization techniques based on finite element modeling. Air-puff induced tissue deformation was determined at seven different locations on the ocular globe, and the maximum apex deformation, the deformation velocity, and the arc-length during deformation were quantified. In the sclera, the experimental maximum deformation amplitude and the corresponding arc length were dependent on the location of air-puff excitation. The normalized temporal deformation profile of the sclera was distinct from that in the cornea, but similar in all tested scleral locations, suggesting that this profile is independent of variations in scleral thickness. Inverse optimization techniques showed that the estimated scleral elastic modulus ranged from 1.84 ± 0.30 MPa (equatorial inferior) to 6.04 ± 2.11 MPa (equatorial temporal). The use of scleral air-puff imaging holds promise for non-invasively investigating the structural changes in the sclera associated with myopia and glaucoma, and for monitoring potential modulation of scleral stiffness in disease or treatment., European Research Council (2018-ADG-SILKEYE-833106); Horizon 2020 Framework Programme European Project Multiply (H-2020-MSCACOFUND-2015 Ref. 713694); Spanish Government (FIS2017-84753-R); Horizon 2020 Framework Programme European Project Imcustomeye (H2020-ICT-2017 Ref. 779960); Spanish Government (CSIC JAE Intro Fellowship); L’Oréal-UNESCO “For Women in Science” Spain; Spanish Government Juan de la Cierva-Incorporation Fellowship (IJC2018-037508-I); Fundacja na rzecz Nauki Polskiej (MAB/2019/12); National Agency for Academic Exchange, Polish Government (NAWA ULAM/2020/1/00176), Peer reviewed
DIGITAL.CSIC. Repositorio Institucional del CSIC
Publicación Artículo científico (JournalArticle)

Eigenlenses: A new model for full crystalline lens shape representation and its applications

  • Martínez-Enríquez, Eduardo
  • Castro, Alberto de
  • Marcos, Susana
17 pages, 8 figures, 1 table, The crystalline lens is an important optical element in the eye, responsible for focusing, and which experiences significant changes throughout life. The shape of the lens is usually studied only in the optical area (central 4 to 6 mm). However, for a great number of applications, a description of the full shape of the crystalline lens is required. We propose a new method for the representation of the full shape of the crystalline lens, constructed from 3-dimensional optical coherence tomography images of 133 isolated crystalline lenses (0-71 y/o), which we have called eigenlenses. The method is shown to be compact and accurate to describe not only the full shape of the crystalline lens, but also the optical zone in comparison with other methods. We also demonstrate its application to the extrapolation of the full shape of the crystalline lens from in-vivo optical images of the anterior segment of the eye, where only the central part of the lens visible through the pupil is available, and in the generation (synthesis) of realistic full lenses of a given age. The method has critical applications, among others, in improving and evaluating myopia and presbyopia treatments., H2020 European Research Council (H2020-MSCA COFUND-2015 FP-713694, MULTIPLY (AdC));Ministerio de Economía y Competitividad (FIS2017-84753-R); Horizon2020 Framework Programme (IMCUSTOMEYE Ref. 779960 (H2020-ICT- 2017-1)); European Research Council (ERC-2011-AdG-294099); National Institutes of Health (R01EY021834).
DIGITAL.CSIC. Repositorio Institucional del CSIC
Publicación Artículo científico (JournalArticle)

Single-shot, depth-encoded multiplexed OCT for multi-spot tracking of induced transient corneal dynamics

  • Karnowski, Karol
  • Milkiewicz, Jadwiga
  • Cetinkaya, Onur
  • Pachacz, Angela
  • Mączyńska-Walkowiak, Ewa
  • Młyniuk, Patryk
  • Curatolo, Andrea
  • Liżewski, Kamil
  • Abass, Ahmed
  • Borycki, Dawid
  • Kałużny, Bartłomiej
  • Marcos, Susana
  • Elsheikh, Ahmed
  • Grulkowski, Ireneusz
  • Wojtkowski, Maciej
[Data Statement] Data underlying the results presented in this paper are not publicly available at this time but may be obtained from the authors upon reasonable request., Fast, non-repeatable transient mechanical events in soft and scattering media are challenging to quantify because they demand high temporal bandwidth, high displacement sensitivity, and multi-point spatial coverage within a single realization. Current non-contact methods for assessing corneal biomechanics often rely on global metrics or single-meridian scanning, potentially missing the focal and asymmetric stiffness changes characteristic in corneal pathologies like keratoconus. In this work, we developed a simultaneous multi-spot air-puff optical coherence tomography (OCT) system as a generalizable parallel interferometric readout architecture to address the limitations of global metrics and single-meridian scanning in detecting focal corneal stiffness changes and to enable artifact-resistant measurement of rapid transients. By leveraging space-division multiplexing with depth encoding, our system tracks dynamic surface deformation at nine locations (one central, eight peripheral) simultaneously. This configuration eliminates sequential scanning artifacts and achieves an effective temporal resolution of 10 µs. We introduce the "Asymmetry Vector" to quantify the magnitude and direction of biomechanical imbalances. In experiments involving a keratoconus-mimicking phantom and human subjects (healthy and keratoconic), this vector correlated strongly with the specific location of corneal pathology. Furthermore, the system revealed a novel "dual-indentation" deformation profile resulting from a spatially widened air-puff stimulus. Beyond corneal elastography, the depth-encoded multiplexed OCT approach provides a scalable route to multi-point, high-speed characterization of transient dynamics where sequential scanning would otherwise induce spatiotemporal misregistration and waveform distortion. These findings establish the technical feasibility of simultaneous multi-spot OCT for biomechanical mapping without sequential-scanning-induced spatiotemporal misregistration and support its potential for automated clinical diagnosis., Foundation for Polish Science (FENG.02.01-IP.05-T005/23); European Union WIDERA in the Teaming for Excellence (project no. 101136570); Horizon 2020 Framework Programme (Imcustomeye H2020-ICT-2017; 779960); National Eye Institute (NEI/NIH P30 EY 001319); National Science Centre (2021/43/I/NZ5/03328); Research to Prevent Blindness Unrestricted Grant, Peer reviewed
DIGITAL.CSIC. Repositorio Institucional del CSIC
Publicación Artículo científico (JournalArticle)

Air-Coupled Ultrasonic Optical Coherence Elastography Reveals Protocol-Dependent Corneal Stiffening in Epi-On and Epi-Off Riboflavin Crosslinking

  • Zvietcovich, Fernando
  • Varea, Alejandra
  • Pleshcheva, Vlada
  • Curatolo, Andrea
  • Birkenfeld, Judith S.
  • Marcos, Susana
Purpose: To evaluate the biomechanical impact of corneal crosslinking (CXL) when combining three different ultraviolet A (UV-A) riboflavin (RB) photosensitizers and protocols (Dresden protocol [DP] and accelerated protocol [AP]) using air-coupled ultrasonic optical coherence elastography in ex vivo rabbit corneas., Methods: An air-coupled ultrasound excitation optical coherence elastography system was used to excite the corneal apex and generate Lamb wave propagation along 16 corneal cross-sectional meridians. Measurements were conducted on ex vivo rabbit eyes (n = 45) during three treatment phases: Virgin, after 30 minutes of RB soaking, and after UV-A irradiation. The protocols used include the DP (3 mW/cm2, 30 minutes) and two accelerated protocols (AP-1: 9 mW/cm2, 10 minutes; and AP-2: 30 mW/cm2, 3 minutes). Each protocol was tested with three photosensitizers: epithelium-on (TE), and epithelium-off with hyperosmolar (M) and hypo-osmolar solutions (D). Lamb wave speed and average corneal thickness were calculated for each meridian to estimate meridian-dependent corneal shear modulus. Differences were statistically analyzed using linear mixed-effects regression., Results: The DP-D produced the strongest significant corneal stiffness increase (480.5 kPa; P < 0.001) during the UV irradiation phase, and the most pronounced corneal thinning (186 µm; P < 0.001). DP-TE achieved the next strongest stiffening (309.5 kPa) during UV irradiation, with no significant thickness change. All other protocol–photosensitizer combinations did not achieve significant corneal stiffening except for AP-1-D and AP-2-D during the RB soaking phase., Conclusions: Accelerated protocols did not produce significant corneal stiffening for any RB photosensitizer except when using dextran-based D. DP-D and DP-TE produced the greatest balance between shear modulus increase and corneal thickness decrease, suggesting DP-TE as a potential compromise between biomechanical impact, corneal integrity, and faster postoperative recovery., Translational Relevance: This work quantified the impact of clinically used crosslinking photosensitizers and protocols on corneal stiffening using an air-coupled ultrasound excitation optical coherence elastography, which holds promise for clinical assessments in patients., Supported by the Spanish Government FIS2017-84753-R, PID2020-115191RB-I00, IND2019/BMD-17262; Horizon 2020 European Project Imcustomeye (H2020-ICT-2017 Ref. 779960); NIH NEI P30EY 001319; Unrestricted Funds Research to Prevent Blindness; Ayudas Ramón y Cajal (RYC2022-037910-I); Ayudas Atracción de Talento RyC (20245AT005); Fundacja na rzecz Nauki Polskiej (MAB/2019/12); National Agency for Academic Exchange, Polish Government (NAWA ULAM/2020/1/00176); and Peruvian CONCYTEC-PROCIENCIA N° PE501082168-2023; PE501093888-2024 and N° PE501098889-2025; Wellcome Trust Early Career Award 300307/Z/23/Z; OPTICA Foundation Challenge Award (2023)., Peer reviewed