Pasar al contenido principal

Resultados relacionados

Resultados totales (Incluyendo duplicados): 8
Encontrada(s) 1 página(s)

DIGITAL.CSIC. Repositorio Institucional del CSIC
Publicación Artículo científico (JournalArticle)

Vision with spatial light modulator simulating multifocal contact lenses in an adaptive optics system

  • Vedhakrishnan, Shrilekha
  • Viñas, María
  • Aissati, Sara
  • Marcos, Susana
14 pags., 7 figs., 1 tab., Visual simulators are useful tools to provide patients experience of multifocal vision prior to treatment. In this study, commercially available center-near aspheric multifocal contact lenses (MCLs) of low, medium, and high additions were mapped on a spatial light modulator (SLM) and validated on a bench. Through focus visual acuity (TFVA) was measured in subjects through the SLM and real MCLs on the eye. A correlation metric revealed statistically significant shape similarity between TFVA curves with real and simulated MCLs. A Bland-Altman analysis showed differences within confidence intervals of ±0.01 logMAR for LowAdd/MediumAdd and ±0.06 logMAR for HighAdd. Visual performance with simulated MCLs outperformed real MCLs by ∼20%. In conclusion, SLM captures the profile of center-near MCLs and reproduces vision with real MCLs, revealing that the MCL profile and its interactions with the eye’s optics (and not fitting aspects) account for the majority of the contributions to visual performance with MCLs, This research has received funding from the European Union’s Horizon 2020 Research and Innovation Program, MyFun under the Marie Sklodowska-Curie grant agreement to SV, and H2020-MSCA-IF-GF2019-MYOMICRO-893557 to MV, under the Marie Sklodowska-Curie grant agreement; European Research Council ERC-2019-AdG-833106 H2020 Innovative Action 779960 & Spanish Government FIS2017-84753-R to SM., Peer reviewed
DIGITAL.CSIC. Repositorio Institucional del CSIC
Publicación Artículo científico (JournalArticle)

Matching convolved images to optically blurred images on the retina

  • Aissati, Sara
  • Benedi, Clara
  • Viñas, María
  • Castro, Alberto de
  • Marcos, Susana
14 pags., 5 figs., Convolved images are often used to simulate the effect of ocular aberrations on image quality, where the retinal image is simulated by convolving the stimulus with the point spread function derived from the subject's aberrations. However, some studies have shown that convolved images are perceived far more degraded than the same image blurred with optical defocus. We hypothesized that the positive interactions between the monochromatic and chromatic aberrations in the eye are lost in the convolution process. To test this hypothesis, we evaluated optical and visual quality with natural optics and with convolved images (on-bench, computer simulations, and visual acuity [VA] in subjects) using a polychromatic adaptive optics system with monochromatic (555 nm) and polychromatic light (WL) illumination. The subject's aberrations were measured using a Hartmann Shack system and were used to convolve the visual stimuli, using Fourier optics. The convolved images were seen through corrected optics. VA with convolved stimuli was lower than VA through natural aberrations, particularly in WL (by 26% in WL). Our results suggest that the systematic decrease in visual performance with visual acuity and retinal image quality by simulation with convolved stimuli appears to be primarily associated with a lack of favorable interaction between chromatic and monochromatic aberrations in the eye., Supported by the Spanish Government (FIS2017-84753R, PID2020-115191RB-I00) to SM; Spanish Government Predoctoral (Grant FPU16/01944) to SA; H2020 Marie Sklodowska-Curie Actions (H2020 MSCA IF GF 2019 MYOMICRO 893557) to MV; European Research Council (ERC-2018-ADG SILKEYE 833106), NIH NIE P30EY 001319; and Unrestricted Funds Research to Prevent Blindness to SM., Peer reviewed
DIGITAL.CSIC. Repositorio Institucional del CSIC
Publicación Artículo científico (JournalArticle)

Visual performance with multifocal lenses in young adults and presbyopes

  • Vedhakrishnan, Shrilekha
  • Viñas, María
  • Benedi, Clara
  • Casado, Pilar
  • Marcos, Susana
21 pags., 9 figs., 1 tab., A better understanding of visual performance with Multifocal Contact Lenses (MCLs) is essential, both in young eyes, where MCLs may be prescribed to control the progression of myopia wherein the MCLs optics interact with accommodation, and in presbyopes, where MCLs are increasingly used to compensate the lack of accommodation. In this study, we evaluated the through focus visual acuity (TFVA) with center-near MCLs of three additions (low, medium and high) and without an addition (NoLens) in 10 young adults and 5 presbyopes. We studied the effect of accommodation, age and pupil diameter (in cyclopleged subjects) on visual performance. The MCLs produced a small but consistent degradation at far (by 0.925 logMAR, averaged across eyes and conditions) and a consistent benefit at near in young subjects with paralyzed accommodation (by 1.025 logMAR), and in presbyopes with both paralyzed and natural accommodation (by 1.071 logMAR, on average). TFVA in young adults with NoLens and all MCLs showed statistically significant differences (Wilcoxan, p<0.01) between natural and paralyzed accommodation, but not in presbyopes with MCLs. In young adults, VA improved with increasing pupil diameter with the HighAdd MCL (0.08 logMAR shift from 3 to 5-mm pupil size). Visual imbalance (standard deviation of VA across distances) was reduced with MCLs, and decreased significantly with increasing near add. The lowest imbalance occurred in young adults under natural accommodation and was further reduced by 13.33% with MCLs with respect to the NoLens condition. Overall, the visual performance with MCLs in young adults exceeds that in presbyopes at all distances, and was better than 0.00 logMAR over the dioptric range tested. In conclusion, the center-near lenses do not degrade the near high contrast visual acuity significantly but maintains the far vision in young adults, and produce some visual benefit at near in presbyopes., This research has received funding from the European Union’s Horizon 2020 Research and Innovation Program, MyFun under the Marie Sklodowska-Curie grant agreement SV, and H2020-MSCA-IF-GF-2019-MYOMICRO-893557 to MV, under the Marie Sklodowska-Curie grant agreement; European Research Council ERC-2019 SILK-EYE & Spanish Government: FIS2019-84753-R to SM; NEI P35 and the Unrestricted Funds Research to Prevent Blindness, NY., Peer reviewed
DIGITAL.CSIC. Repositorio Institucional del CSIC
Publicación Artículo científico (JournalArticle)

Understanding In Vivo Chromatic Aberrations in Pseudophakic Eyes Using on Bench and Computational Approaches

  • Viñas, María
  • Castro, Alberto de
  • Dorronsoro, Carlos
  • González-Ramos, Ana
  • Redzovic, Suad
  • Willet, Nicolas
  • Garzon, Nuria
  • Marcos, Susana
16 pags., 8 figs., 2 tabs. -- This article belongs to the Special Issue Ocular Imaging for Eye Care, Diffractive multifocal intraocular lenses (IOLs) modulate chromatic aberration and reduce it at certain distances due to interactions between the refractive and diffractive chromatic components. However, the extent to which computer modeling and on bench measurements of IOL chromatic aberration translate to chromatic aberration in patients implanted with these multifocal IOLs (MIOLs) is not yet fully understood. In this study, we compare the chromatic difference of focus and longitudinal chromatic aberrations in pseudophakic patients implanted with different IOL designs (monofocal and trifocal IOLs) and materials (hydrophobic and hydrophilic), and compared them with predictions from computer eye models and on bench measurements with the same IOLs. Patient data consisted of results from 63 pseudophakic eyes reported in four different studies and obtained psychophysically in the visual testing channel of a custom-developed polychromatic adaptive optics system. Computational predictions were obtained using ray tracing on computer eye models, and modulation transfer function (MTF) on bench measurements on physical eye models. We found that LCA (in vivo/simulated) for far vision was 1.37 ± 0.08 D/1.19 D for monofocal hydrophobic, 1.21 ± 0.08 D/0.88 D for monofocal hydrophilic, 0.99 ± 0.06 D/1.19 D for MIOL hydrophobic, and 0.82 ± 0.05 D/0.88 D for MIOL hydrophilic. For intermediate and near vision, LCA (in vivo/simulated) was 0.67 ± 0.10 D/0.75 D and 0.23 ± 0.08 D/0.19 D for MIOL hydrophobic and 0.27 ± 0.15 D/0.38 D and 0.15 ± 0.15 D/−0.13 D for MIOL hydrophilic, respectively. In conclusion, computational ray tracing and on bench measurements allowed for evaluating in vivo chromatic aberration with different materials and designs for multifocal diffractive intraocular lenses., This research received funding from the European Research Council under the ERC2011-AdG-294099 to S.M. and the H2020-MSCA-IF-GF-2019-MYOMICRO-893557 to M.V.-P.; the Spanish Government grant FIS2017-84753 and PID2020-115191RB-I00 to S.M., and collaborative agreements (2014–2020) with PhyIOL (Liege, Belgium), the National Eye Institute P30 Core Grant EY001319-46 (Center for Visual Science), and Unrestricted grant Research to Prevent Blindness (Flaum Eye Institute)., Peer reviewed
DIGITAL.CSIC. Repositorio Institucional del CSIC
Publicación Artículo científico (JournalArticle)

In situ measurement of the stiffness increase in the posterior sclera after UV-riboflavin crosslinking by optical coherence elastography

  • Viñas, María
  • Feng, Xu
  • Li, Guo-Yang
  • Yun, Seok-Hyun
13 pags., 8 figs., Scleral crosslinking may provide a way to prevent or treat myopia by stiffening scleral tissues. The ability to measure the stiffness of scleral tissues in situ pre and post scleral crosslinking would be useful but has not been established. Here, we tested the feasibility of optical coherence elastography (OCE) to measure shear modulus of scleral tissues and evaluate the impact of crosslinking on different posterior scleral regions using ex vivo porcine eyes as a model. From measured elastic wave speeds at 6 - 16 kHz, we obtained out-of-plane shear modulus value of 0.71 ± 0.12 MPa (n = 20) for normal porcine scleral tissues. After riboflavin-assisted UV crosslinking, the shear modulus increased to 1.50 ± 0.39 MPa (n = 20). This 2-fold change was consistent with the increase of static Young's modulus from 5.5 ± 1.1 MPa to 9.3 ± 1.9 MPa after crosslinking, which we measured using conventional uniaxial extensometry on tissue stripes. OCE revealed regional stiffness differences across the temporal, nasal, and deeper posterior sclera. Our results show the potential of OCE as a noninvasive tool to evaluate the effect of scleral crosslinking., National Institutes of Health (R01-EB027653 and R42-EY028820 to SY); HORIZON EUROPE Marie Sklodowska-Curie Actions (H2020-MSCA-IF-GF-2019-MYOMICRO-893557 to MV)., Peer reviewed
DIGITAL.CSIC. Repositorio Institucional del CSIC
Publicación Artículo científico (JournalArticle)

Multifocal contact lens vision simulated with a clinical binocular simulator

  • Barcala, Xoana
  • Viñas, María
  • Ruiz, Sofia
  • Hidalgo, Fernando
  • Nankivil, Derek
  • Karkkainen, Tom
  • Gambra, Enrique
  • Dorronsoro, Carlos
  • Marcos, Susana
11 pags., 10 figs., 2 tabs., The purpose of this study is to compare the binocular visual perception of participants wearing multifocal contact lenses and these same lens designs viewed through a temporal multiplexing visual simulator., This research has received funding from the European Research Council under the IMCUSTOMEYE Ref. 779,960 H2020 - EU.2.1.1. Industrial Leadership to SM; SILK-EYE Ref. 833,106 Excellent Science – ERC to SM; and the H2020-MSCA-IF-GF-2019-MYOMICRO-893557 to MV. National Eye Institute P30 Core Grant EY001319-46 (Center for Visual Science) and Unrestricted grant Research to Prevent Blindness (Flaum Eye Institute) to SM. This research was supported also from the Spanish Government under the Spanish Government Grant FIS2017-84753-R to SM, and ISCIII DTS16/00127 to CD; Madrid Regional Government IND2017/BMD7670 to XB; and Master Clinical Research Agreement between Johnson and Johnson Vision Care (USA), 2EyesVision, Centro Boston de Optometría and IO-CISC., Peer reviewed
DIGITAL.CSIC. Repositorio Institucional del CSIC
Publicación Artículo científico (JournalArticle)

Accommodation through simulated multifocal optics

  • Vedhakrishnan, Shrilekha
  • Castro, Alberto de
  • Viñas, María
  • Aissati, Sara
  • Marcos, Susana
16 pags., 7 figs., We evaluated the interaction of multifocal patterns with eye's accommodation. Seven patterns were mapped on the spatial light modulator and the deformable mirror of an adaptive optics visual simulator, and projected onto the subjects' eyes, representing different contact lens designs: NoLens, Bifocal Center Distance (+2.50D), Bifocal Center Near (+2.50D) and Multifocal Center Near-MediumAdd (+1.75D) and Center Near HighAdd (+2.50D), positive and negative spherical aberration (±1µm). The change in spherical aberration and the accommodative response to accommodative demands were obtained from Hartmann-Shack measurements. Positive spherical aberration and Center Distance designs are consistent with a higher accommodative response (p=0.001 & p=0.003): steeper shift of SA towards negative values and lower accommodative lag., Marie Sklodowska-Curie (ADC, H2020-MSCA-IF-GF-2019-MYOMICRO-893557, SV, PID2020-115191); European Research Council (ERC-2019-AdG-833106 H2020); Innovative Action (779960); Spanish Government (FIS2017-84753-R, NIH P30, RPB unrestricted funds to SM), Peer reviewed
DIGITAL.CSIC. Repositorio Institucional del CSIC
Publicación Artículo científico (JournalArticle)

Multifocal contact lens vision simulated with a clinical binocular simulator

  • Barcala, Xoana
  • Viñas, María
  • Ruiz, Sofia
  • Hidalgo, Fernando
  • Nankivil, Derek
  • Karkkainen, Tom
  • Gambra, Enrique
  • Dorronsoro, Carlos
  • Marcos, Susana
Artículo con 10 figuras, Purpose: The purpose of this study is to compare the binocular visual perception of participants wearing multifocal contact lenses and these same lens designs viewed through a temporal multiplexing visual simulator. Methods: Visual performance and perceived visual quality at various distances were obtained in 37 participants wearing soft M−CLs and through the SimVis Gekko programmed with the same lenses. In a pilot study (n = 10) visual performance was measured in terms of LogMAR visual acuity (VA) at far (4 m), intermediate (64 cm) and near (40 cm) distances and through-focus VA (TFVA) curves with the simulated M−CLs. In the follow-up study (n = 27), LogMAR VA at far, intermediate and near distances were measured both with the actual and simulated M−CLs. Perceived visual quality was measured in both studies using the Multifocal Acceptance Score (MAS-2EV), and a Participants Reported Outcomes Vision questionnaire. Differences between the metrics obtained with simulated and actual lenses were obtained. Results: Both actual and simulated M−CLs increased depth-of-focus by a similar amount. Mean LogMAR VA differences with actual and simulated M−CLs ranged between 4 and 6 letters (0.08 ± 0.01, 0.12 ± 0.01 and 0.10 ± 0.01, for far, intermediate and near distances, respectively). MAS-2EV average score differences with actual and simulated M−CLs ranged between −1.00 and + 4.25. Average MAS-2EV scores were not correlated significantly with VA. However, MAS-2EV (average and individual scores) were highly correlated to visual quality questionnaire responses (p < 0.005). Conclusions: A simultaneous vision simulator accurately represented vision with M−CLs both VA at various distances and perceived visual quality, as measured in a clinical setting. The MAS-2EV metric accurately captured participant reported outcomes of standard vision questionnaires. The combination of SimVis Gekko and MAS-2EV has the potential to largely reduce chair time in M−CLs fitting., This research has received funding from the European Research Council under the IMCUSTOMEYE Ref. 779,960 H2020 - EU.2.1.1. In- dustrial Leadership to SM; SILK-EYE Ref. 833,106 Excellent Science – ERC to SM; and the H2020-MSCA-IF-GF-2019-MYOMICRO-893557 to MV. National Eye Institute P30 Core Grant EY001319-46 (Center for Visual Science) and Unrestricted grant Research to Prevent Blindness (Flaum Eye Institute) to SM. This research was supported also from the Spanish Government under the Spanish Government Grant FIS2017- 84753-R to SM, and ISCIII DTS16/00127 to CD; Madrid Regional Gov- ernment IND2017/BMD7670 to XB; and Master Clinical Research Agreement between Johnson and Johnson Vision Care (USA), 2Eye- sVision, Centro Boston de Optometría and IO-CISC