Pasar al contenido principal

Resultados relacionados

Resultados totales (Incluyendo duplicados): 23
Encontrada(s) 1 página(s)

DIGITAL.CSIC. Repositorio Institucional del CSIC
Publicación Contribución de congreso (ConferenceOutput)

3D OCT-based geometrical changes of human crystalline lenses during simulated accommodation in a lens stretcher

  • Martínez-Enríquez, Eduardo
  • Castro, Alberto de
  • Mohamed, Ashik
  • Maceo Heilman, B.
  • Williams, S.
  • Nandyala, S.
  • Ruggeri, Marco
  • Parel, J. M. A.
  • Augusteyn, Robert
  • Ho, Arthur
  • Manns, Fabrice
  • Marcos, Susana
This is a 2020 ARVO Annual Meeting abstract., Support European Project MyFUN H2020-MSCA-ITN-2015 Ref. 675137, European Project IMCUSTOMEYE H2020-ICT-2017 Ref. 779960​, European Project SILKEYE H2020-ERC-2018-ADG Ref. 833106, European Project COFUND Multiply H-2020-MSCA-COFUND-2015 Ref. 713694, Spanish government grant FIS2017-84753-R, NEI Grants: R01EY021834, F31EY021444 (Maceo), P30EY14801 (Center Grant); the Florida Lions Eye Bank; Research to Prevent Blindness; Drs. KR Olsen and ME Hildebrandt, Drs. Raksha Urs and Aaron Furtado, the Henri and Flore Lesieur Foundation (JMP); Hyderabad Eye Research Foundation., Peer reviewed
DIGITAL.CSIC. Repositorio Institucional del CSIC
Datos de investigación Set de datos (Dataset)

Data for the paper “Optical and visual quality of real intraocular lenses physically projected on the patient’s eye”

  • Benedi, Clara
  • Viñas, María
  • Lago, Carmen M.
  • Aissati, Sara
  • Castro, Alberto de
  • Dorronsoro, Carlos
  • Marcos, Susana
The provided Data Set contains an Excel file with the results obtained in the study entitled “Optical and visual quality of the real intraocular lenses physically projected on the patient’s eye”, by C. Benedi-Garcia, M. Vinas, C. M. Lago, S. Aissati, A. de Castro, C. Dorronsoro, S. Marcos, to be published in Biomedical Optics Express (2021)., Visual simulators aim at evaluating vision with ophthalmic corrections prior to prescription or implantation of intraocular lenses (IOLs) in the patient’s eye. In the present study, we present the design, implementation, and validation of a new IOL-in-cuvette channel in an Adaptive Optics visual simulator, which provides an alternative channel for pre-operative simulation of vision with IOLs. IOL-in-cuvette is projected to the pupil’s plane of the subject by using a Rassow system. A second lens, the Rassow lens, compensates for an IOL of 20 D while other powers can be corrected with a Badal system in a 5 D range. The new channel was evaluated by through-focus (TF) optical quality on an artificial eye on bench, and by TF visual acuity in patients, with various IOL designs (monofocal, diffractive trifocal, and refractive extended depth of focus)., Spanish Government FIS2017-84753R. Spanish Government Predoctoral Grant FPU16/01944 to SA. ERC AdG-2018-833106 SILKEYE to SM., Peer reviewed
DIGITAL.CSIC. Repositorio Institucional del CSIC
Publicación Artículo científico (JournalArticle)

Isolated human crystalline lens three-dimensional shape: A comparison between Indian and European populations

  • Mohamed, Ashik
  • Nandyala, S.
  • Martínez-Enríquez, Eduardo
  • Maceo Heilman, B.
  • Augusteyn, Robert
  • Castro, Alberto de
  • Ruggeri, Marco
  • Parel, J. M. A.
  • Marcos, Susana
  • Manns, Fabrice
6 pags., 2 figs., 2 tabs., There have been many studies on lens properties in specific populations (e.g. in China, Europe, Singapore, etc.) some of which suggest there may be differences between populations. Differences could be caused by ethnic or environmental influences or experimental procedures. The purpose of this study is to evaluate if any differences exist between Indian and European populations in the central geometric and full shape properties of human lenses. Two custom-developed spectral domain optical coherence tomography systems were used to acquire the crystalline lens geometry: one in India (69 lenses from 59 donors) and the other in Spain (24 lenses from 19 donors). The steps for obtaining accurate 3-D models from optical coherence tomography raw images comprised of image segmentation, fan and optical distortion correction, tilt removal and registration. The outcome variables were lens equatorial diameter, lens thickness, anterior and posterior lens thicknesses and their ratio, central radius of curvature of the anterior and posterior lens surfaces, lens volume and lens surface area. A mixed effects model by maximum likelihood estimation was used to evaluate the effect of age, population and their interaction (age*population) on lens parameters. After adjusting for age, there were no population differences observed in anterior and posterior radii of curvature, equatorial diameter, lens thickness, anterior and posterior lens thicknesses and their ratio, volume and surface area (all p ≥ 0.08). There was also no effect of the interaction term on anterior and posterior radii of curvature, equatorial diameter, lens thickness, anterior and posterior lens thicknesses and their ratio, volume and surface area (all p ≥ 0.06). All central geometric and full shape parameters appeared to be comparable between the European and Indian populations. This is the first study to compare geometric and full shape lens parameters between different populations in vitro., This work was supported by the National Institutes of Health/National Eye Institute [Grants 2R01EY021834 and P30EY14801 (Center Grant)]; the Hyderabad Eye Research Foundation; Ministerio de Educacion y Ciencia, Spain (FIS2017- 84753-R), European Research Council (ERC-2018-AdG-833106) and IMCUSTOMEYE Ref. 779960 (H2020- ICT- 2017-1) to S. Marcos, and European Research Council (ERC) under European Union’s Horizon 2020 research and innovation programme H2020-MSCA COFUND-2015 FP-713694, MULTIPLY(AdC), CSIC ICoop Program, Florida Lions Eye Bank and the Beauty of Sight Foundation, an unrestricted grant from Research to Prevent Blindness to the Department of Ophthalmology, University of Miami and the Henri and Flore Lesieur Foundation (J-M. Parel).
DIGITAL.CSIC. Repositorio Institucional del CSIC
Publicación Artículo científico (JournalArticle)

Simulating Outcomes of Cataract Surgery: Important Advances in Ophthalmology

  • Marcos, Susana
  • Martínez-Enríquez, Eduardo
  • Viñas, María
  • Castro, Alberto de
  • Dorronsoro, Carlos
  • Bang, Seung Pil
  • Yoon, Geunyoung
  • Artal, Pablo
32 pags., 10 figs., As the human eye ages, the crystalline lens stiffens (presbyopia) and opacifies (cataract), requiring its replacement with an artificial lens [intraocular lens (IOL)]. Cataract surgery is the most frequently performed surgical procedure in the world. The increase in IOL designs has not been paralleled in practice by a sophistication in IOL selection methods, which rely on limited anatomical measurements of the eye and the surgeon's interpretation of the patient's needs and expectations. We propose that the future of IOL selection will be guided by 3D quantitative imaging of the crystalline lens to map lens opacities, anticipate IOL position, and develop fully customized eye models for ray-tracing-based IOL selection. Conversely, visual simulators (in which IOL designs are programmed in active elements) allow patients to experience prospective vision before surgery and to make more informed decisions about which IOL to choose. Quantitative imaging and optical and visual simulations of postsurgery outcomes will allow optimal treatments to be selected for a patient undergoing modern cataract surgery., The authors have received funding from the following sources: H2020-MSCA-ITN-2015- 675137 IMCUSTOMEYE (S.M.); ERC-2011-AdG-294099 PRESBYOPIA (S.M.); ERC-PoCOCT4IOL (S.M.); ERC-PoC-SimVisSim (S.M.); ERC-2018-AdG-833106-SilkEye (S.M.) and ERC-2013-AdG-339228 SEECAT (P.A.); Spanish Agencia Estatal de Investigación FIS2017- 84753-R (S.M.) and PID2019-105684RB-I00 (P.A.); Fundación Séneca-Agencia de Ciencia y Tecnología de la Región de Murcia 19897/GERM/15 (P.A.); National Institutes of Health/National Eye Institute (G.Y.); Research to Prevent Blindness (G.Y.); and NYSTAR/CEIS/CoE (G.Y.).
DIGITAL.CSIC. Repositorio Institucional del CSIC
Publicación Artículo científico (JournalArticle)

Functional integration of eye tissues and refractive eye development: Mechanisms and pathways

  • Summers, Jody A.
  • Schaeffel, Frank
  • Marcos, Susana
  • Wu, Hao
  • Tkatchenko, Andrei V.
15 pags., 3 figs., Refractive eye development is a tightly coordinated developmental process. The general layout of the eye and its various components are established during embryonic development, which involves a complex cross-tissue signaling. The eye then undergoes a refinement process during the postnatal emmetropization process, which relies heavily on the integration of environmental and genetic factors and is controlled by an elaborate genetic network. This genetic network encodes a multilayered signaling cascade, which converts visual stimuli into molecular signals that guide the postnatal growth of the eye. The signaling cascade underlying refractive eye development spans across all ocular tissues and comprises multiple signaling pathways. Notably, tissue-tissue interaction plays a key role in both embryonic eye development and postnatal eye emmetropization. Recent advances in eye biometry, physiological optics and systems genetics of refractive error have significantly advanced our understanding of the biological processes involved in refractive eye development and provided a framework for the development of new treatment options for myopia. In this review, we summarize the recent data on the mechanisms and signaling pathways underlying refractive eye development and discuss new evidence suggesting a wide-spread signal integration across different tissues and ocular components involved in visually guided eye growth., This work was supported in part by the National Institutes of Health grants R01EY09391 (JAS), R01EY023839 (AVT), P30EY019007 (Core Support for Vision Research received by the Department of Ophthalmology, Columbia University), Research to Prevent Blindness (Unrestricted funds received by the Department of Ophthalmology, Columbia University), European Commission grant H2020-MSCA-ITN-2015-675137 (SM), European Research Council grant ERC-2018-ADG-SILKEYE-833106 (SM) and Spanish Government grant FIS 2017-84753-R (SM).
DIGITAL.CSIC. Repositorio Institucional del CSIC
Publicación Artículo científico (JournalArticle)

Matching convolved images to optically blurred images on the retina

  • Aissati, Sara
  • Benedi, Clara
  • Viñas, María
  • Castro, Alberto de
  • Marcos, Susana
14 pags., 5 figs., Convolved images are often used to simulate the effect of ocular aberrations on image quality, where the retinal image is simulated by convolving the stimulus with the point spread function derived from the subject's aberrations. However, some studies have shown that convolved images are perceived far more degraded than the same image blurred with optical defocus. We hypothesized that the positive interactions between the monochromatic and chromatic aberrations in the eye are lost in the convolution process. To test this hypothesis, we evaluated optical and visual quality with natural optics and with convolved images (on-bench, computer simulations, and visual acuity [VA] in subjects) using a polychromatic adaptive optics system with monochromatic (555 nm) and polychromatic light (WL) illumination. The subject's aberrations were measured using a Hartmann Shack system and were used to convolve the visual stimuli, using Fourier optics. The convolved images were seen through corrected optics. VA with convolved stimuli was lower than VA through natural aberrations, particularly in WL (by 26% in WL). Our results suggest that the systematic decrease in visual performance with visual acuity and retinal image quality by simulation with convolved stimuli appears to be primarily associated with a lack of favorable interaction between chromatic and monochromatic aberrations in the eye., Supported by the Spanish Government (FIS2017-84753R, PID2020-115191RB-I00) to SM; Spanish Government Predoctoral (Grant FPU16/01944) to SA; H2020 Marie Sklodowska-Curie Actions (H2020 MSCA IF GF 2019 MYOMICRO 893557) to MV; European Research Council (ERC-2018-ADG SILKEYE 833106), NIH NIE P30EY 001319; and Unrestricted Funds Research to Prevent Blindness to SM., Peer reviewed
DIGITAL.CSIC. Repositorio Institucional del CSIC
Publicación Artículo científico (JournalArticle)

Accommodation through simulated multifocal optics

  • Vedhakrishnan, Shrilekha
  • Castro, Alberto de
  • Viñas, María
  • Aissati, Sara
  • Marcos, Susana
16 pags., 7 figs., We evaluated the interaction of multifocal patterns with eye's accommodation. Seven patterns were mapped on the spatial light modulator and the deformable mirror of an adaptive optics visual simulator, and projected onto the subjects' eyes, representing different contact lens designs: NoLens, Bifocal Center Distance (+2.50D), Bifocal Center Near (+2.50D) and Multifocal Center Near-MediumAdd (+1.75D) and Center Near HighAdd (+2.50D), positive and negative spherical aberration (±1µm). The change in spherical aberration and the accommodative response to accommodative demands were obtained from Hartmann-Shack measurements. Positive spherical aberration and Center Distance designs are consistent with a higher accommodative response (p=0.001 & p=0.003): steeper shift of SA towards negative values and lower accommodative lag., Marie Sklodowska-Curie (ADC, H2020-MSCA-IF-GF-2019-MYOMICRO-893557, SV, PID2020-115191); European Research Council (ERC-2019-AdG-833106 H2020); Innovative Action (779960); Spanish Government (FIS2017-84753-R, NIH P30, RPB unrestricted funds to SM), Peer reviewed
DIGITAL.CSIC. Repositorio Institucional del CSIC
Publicación Artículo científico (JournalArticle)

Co-axial acoustic-based optical coherence vibrometry probe for the quantification of resonance frequency modes in ocular tissue

  • McAuley, Ryan
  • Nolan, Andrew
  • Curatolo, Andrea
  • Alexandrov, Sergey
  • Zvietcovich, Fernando
  • Varea, Alejandra
  • Marcos, Susana
  • Leahy, Martin
  • Birkenfeld, Judith S.
Artículo con 10 figuras, We present a co-axial acoustic-based optical coherence vibrometry probe (CoA-OCV) for vibro-acoustic resonance quantification in biological tissues. Sample vibrations were stimulated via a loudspeaker, and pre-compensation was used to calibrate the acoustic spectrum. Sample vibrations were measured via phase-sensitive swept-source optical coherence tomography (OCT). Resonance frequencies of corneal phantoms were measured at varying intraocular pressures (IOP), and dependencies on Young¿s Modulus (E), phantom thickness and IOP were observed. Cycling IOP revealed hysteresis. For E = 0.3 MPa, resonance frequencies increased with IOP at a rate of 3.9, 3.7 and 3.5 Hz/mmHg for varied thicknesses and 1.7, 2.5 and 2.8 Hz/mmHg for E = 0.16 MPa. Resonance frequencies increased with thickness at a rate of 0.25 Hz/µm for E = 0.3 MPa, and 0.40 Hz/µm for E = 0.16 MPa. E showed the most predominant impact in the shift of the resonance frequencies. Full width at half maximum (FWHM) of the resonance modes increased with increasing thickness and decreased with increasing E. Only thickness and E contributed to the variance of FWHM. In rabbit corneas, resonance frequencies of 360–460 Hz were observed. The results of the current study demonstrate the feasibility of CoA-OCV for use in future OCT-V studies., The research leading to these results has received funding from: Horizon 2020 European Project Imcustomeye (H2020-ICT-2017 Ref. 779960); European Research Council 2018-ADG-SILKEYE-833106; Spanish Government FIS2017-84753-R, PID2020-115191RB-I00; NIH NIE P30EY 001319; Unrestricted Funds Research to Prevent Blindness, NY; Juan de la Cierva (IJC2018-037508-I); L'Oréal-UNESCO “For Women in Science” Spain; Fundacja na rzecz Nauki Polskiej (MAB/2019/12); Polish National Agency for Academic Exchange, (NAWA ULAM/2020/1/00176).The funding organizations had no role in the design or conduct of this research.
DIGITAL.CSIC. Repositorio Institucional del CSIC
Publicación Artículo científico (JournalArticle)

Estimation of the full shape of the crystalline lens in-vivo from OCT images using eigenlenses

  • Martínez-Enríquez, Eduardo
  • Curatolo, Andrea
  • Castro, Alberto de
  • Birkenfeld, Judith S.
  • González-Ramos, Ana M.
  • Mohamed, Ashik
  • Ruggeri, Marco
  • Manns, Fabrice
  • Fernando, Zvietcovich
  • Marcos, Susana
19 pags., 9 figs., 5 tabs., Quantifying the full 3-D shape of the human crystalline lens is important for improving intraocular lens power or sizing calculations in treatments of cataract and presbyopia. In a previous work we described a novel method for the representation of the full shape of the ex vivo crystalline lens called eigenlenses, which proved more compact and accurate than compared state-of-the art methods of crystalline lens shape quantification. Here we demonstrate the use of eigenlenses to estimate the full shape of the crystalline lens in vivo from optical coherence tomography images, where only the information visible through the pupil is available. We compare the performance of eigenlenses with previous methods of full crystalline lens shape estimation, and demonstrate an improvement in repeatability, robustness and use of computational resources. We found that eigenlenses can be used to describe efficiently the crystalline lens full shape changes with accommodation and refractive error., HORIZON EUROPE European Research Council (IMCUSTOMEYE H2020-ICT-2017 Ref. 779960;); European Research Council (SILKEYE H2020-ERC-571 2018-ADG Ref.833106); Ministerio de Ciencia e Innovación (PID2020-115191RB-I00); Narodowa Agencja Wymiany Akademickiej (ULAM 2020/1/00176); Fundacja narzecz Nauki Polskiej (MAB/2019/12); L’Oréal-UNESCO “For Women in Science”; Ministerio de Ciencia, Innovación y Universidades (IJC2018-037508-I, Juan de la Cierva-Incorporation); Research to Prevent Blindness (Bascom Palmer Eye Institute, Flaum Eye Institute); National Institutes of Health (NIE P30EY 001319); Unrestricted Funds Research to Prevent Blindness, NY; National Institutes of Health (R01EY021834); National Institutes of Health (P30EY014801); Florida Lions Eye Bank and Beauty of Sight Foundation; Hyderabad Eye Research Foundation., Peer reviewed
DIGITAL.CSIC. Repositorio Institucional del CSIC
Publicación Artículo científico (JournalArticle)

Estimation of Crystalline Lens Material Properties From Patient Accommodation Data and Finite Element Models

  • Hoz, A. de la
  • Martínez-Enríquez, Eduardo
  • Marcos, Susana
10 pags., 6 figs., 1 tab., The mechanical properties of the crystalline lens are related to its optical function of accommodation, and their changes with age are one of the potential causes for presbyopia. We estimated the mechanical parameters of the crystalline lens using quantitative optical coherence tomography (OCT) imaging and wavefront sensing data from accommodating participants and computer modeling., Supported by European Research Council 2018-AdG-Silkeye 833106, P30 Core Grant EY001319-46, Unrestricted Grant Research to Prevent Blindness (Flaum Eye Institute, University of Rochester, NY), and Spanish Government PID2020-115191RB-100., Peer reviewed
DIGITAL.CSIC. Repositorio Institucional del CSIC
Publicación Artículo científico (JournalArticle)

Estimation of the full shape of the crystalline lens from OCT: validation using stretched donor lenses

  • Martínez-Enríquez, Eduardo
  • Maceo Heilman, Bianca
  • Castro, Alberto de
  • Mohamed, Ashik
  • Ruggeri, Marco
  • Zvietcovich, Fernando
  • Manns, Fabrice
  • Marcos, Susana
16 pags., 6 figs., 2 tabs., Quantifying human crystalline lens geometry as a function of age and accommodation is important for improved cataract and presbyopia treatments. In previous works we presented eigenlenses as a basis of 3-D functions to represent the full shape of the crystalline lens ex vivo. Also, we presented the application of eigenlenses to estimate the full shape of the lens in vivo from 3-D optical coherence tomography (OCT) images, where only the central part of the lens -visible through the pupil- is available. The current work presents a validation of the use of eigenlenses to estimate in vivo the full shape of dis-accommodated lenses. We used 14 ex vivo crystalline lenses from donor eyes (11-54 y/o) mounted in a lens stretcher, and measured the geometry and the power of the lenses using a combined OCT and ray tracing aberrometry system. Ex vivo, the full extent of the lens is accessible from OCT because the incident light is not blocked by the iris. We measured in non-stretched (fully accommodated) and stretched (mimicking in vivo dis-accommodated lenses) conditions. Then, we simulated computationally in vivo conditions on the obtained ex vivo lenses geometry (assuming that just the portion of the lens within a given pupil is available), and estimated the full shape using eigenlenses. The mean absolute error (MAE) between estimated and measured lens' diameters and volumes were MAE = 0.26 ± 0.18 mm and MAE = 7.0 ± 4.5 mm3, respectively. Furthermore, we concluded that the estimation error between measured and estimated lenses did not depend on the accommodative state (change in power due to stretching), and thus eigenlenses are also useful for the full shape estimation of in vivo dis-accommodated lenses., European Project IMCUSTOMEYE H2020-ICT-2017 Ref. 779960; European Project SILKEYE H2020- ERC-2018-ADG Ref. 833106; Spanish government grant PID2020-115191RB-I00; NIH grants P30; Research to Prevent Blindness Departmental Funds to Flaum Eye Insitute and Bascom Palmer Eye Institute; NIE P30EY 001319; Unrestricted Funds to Research to Prevent Blindness, NY; National Institutes of Health Center Core Grant (R01EY021834); Florida Lions Eye Bank and Beauty of Sight Foundation; Hyderabad Eye Research Foundation., Peer reviewed
DIGITAL.CSIC. Repositorio Institucional del CSIC
Publicación Artículo científico (JournalArticle)

Monovision Correction Preference and Eye Dominance Measurements

  • Rodríguez-López, Víctor
  • Barcala, Xoana
  • Zaytouny, Amal
  • Dorronsoro, Carlos
  • Peli, Eli
  • Marcos, Susana
12 pags., 8 figs., 1 tab., To propose new methods for eye selection in presbyopic monovision corrections., Supported by “la Caixa” Foundation (ID 100010434; LCF/BQ/DR19/11740032) to V.R.L.; Madrid Regional Government IND2017/BMD7670 to X.B. and A.Z.; Health Institute Carlos III PID2020- 115191RB-I00 to C.D.; National Eye Institute R01-EY23385 to E.P.; Grant FIS2017-84753-R and PID2020-115191RB-I00 (Agencia Estatal de Investigación, Spain) and European Research Council Advanced Grant SILK-EYE Ref. 833106 Excellent Science – ERC, National Eye Institute P30 Core Grant EY001319-46 (Center for Visual Science, University of Rochester, NY) and Unrestricted grant Research to Prevent Blindness (Flaum Eye Institute, University of Rochester, NY) to S.M., Peer reviewed
DIGITAL.CSIC. Repositorio Institucional del CSIC
Publicación Artículo científico (JournalArticle)

Poster Session: Estimation of scleral biomechanical properties from air-puff-coupled optical coherence tomography

  • Birkenfeld, Judith S.
  • Villegas, Lupe
  • Hoz, A. de la
  • Bronte-Ciriza, David
  • Varea, Alejandra
  • Martínez-Enríquez, Eduardo
  • Curatolo, Andrea
  • Germann, James
  • Marcos, Susana
Optica Fall Vision Meeting Abstract, Progression of myopia is usually accompanied by axial overgrowth of the eyeball, which affects scleral biomechanics (BM). To study scleral biomechanics, we propose the use of air-puff deformation swept-source OCT imaging. Air-puff deformation imaging was performed at different sites of ex vivo porcine (n=5) and rabbit (n=3) eyes, (<24hr postmortem): Nasal/temporal equatorial and posterior sclera (NE, NP, TE, TP), superior (S) and inferior (I) sclera, and cornea (C). Intraocular pressure was kept at 15mmHg. Deformation data were used as input to inverse finite element model (FEM) algorithms to reconstruct BM properties. Experimental deformation amplitudes showed dependence on the animal model, with porcine scleras exhibiting greater inter-site variation (displacement of S, I was up to four times greater than that of N, T), while rabbit scleras exhibited at most 40% of displacement differences between all sites. Both models showed significant (p<.001) differences in the temporal deformation profile between sclera and (C), but similarities in all scleral locations, suggesting that the scleral temporal profile is independent of scleral thickness variations. The FEM estimated an elastic modulus of 1.84 ± 0.30 MPa (I) to 6.04 ± 2.11 MPa (TE) for the porcine sclera. The use of scleral air-puff imaging is promising for noninvasive investigation of structural changes in the sclera associated with myopia and for monitoring possible modulation of scleral stiffness with myopia treatment., Funding: Horizon 2020 Framework Programme European Project Imcustomeye (H2020-ICT-2017 Ref. 779960); European Research Council (2018-ADG-SILKEYE-833106); Spanish Government 10.13039/100014440 (CSIC JAE Intro Fellowship); L'Oréal-UNESCO “For Women in Science” Spain; Spanish Government Juan de la Cierva-Incorporation Fellowship (IJC2018-037508-I); Spanish Government PID2020-115191RB-I00; Fundacja na rzecz Nauki Polskiej (MAB/2019/12); National Agency for Academic Exchange, Polish Government (NAWA ULAM/2020/1/00176); NIH NIE P30EY 001319; Unrestricted Funds Research to Prevent Blindness, NY, Peer reviewed
DIGITAL.CSIC. Repositorio Institucional del CSIC
Publicación Artículo científico (JournalArticle)

Poster Session: Experimental assessment of scleral anisotropy using multi-meridian air-coupled ultrasonic optical coherence elastography

  • Villegas, Lupe
  • Zvietcovich, Fernando
  • Varea, Alejandra
  • Curatolo, Andrea
  • Birkenfeld, Judith S.
  • Marcos, Susana
Optica Fall Vision Meeting Abstract, September 2023, Scleral biomechanics plays a key role in the understanding of myopia progression. In this study, we characterized the elastic properties of sclera using an air-coupled ultrasonic (ACUS) optical coherence elastography (OCE) system. New Zealand rabbit eyes (n=7) were measured (<24hr postmortem) in four scleral locations: superior/inferior temporal (ST, IT), and superior/inferior nasal (SN, IN) maintaining an intraocular pressure of 15 mmHg. Elastic waves were induced in the sclera, and wave propagation velocity and shear modulus were measured along two directions: circumferential (superior-inferior) and meridional (nasal-temporal). Wave velocity in scleral tissue ranged from 6 to 24 m/s and shear modulus from 11 to 150 kPa. Velocity was significantly higher (p<.001) in the circumferential vs. meridional directions in the following locations: ST:15.83±2.85 vs 9.43±1.68 m/s, IT:15.00±3.98 vs 8.93±1.53 m/s; SN:16.79±4.30 vs 9.27±1.47 m/s; and IN:13.92±3.85 vs 8.57±1.46 m/s. The average shear modulus in the circumferential was also significantly higher (p<.001) than in the meridional direction for all locations: 65.37±6.04 vs 22.55±1.36 kPa. These results show that the rabbit sclera is mechanically anisotropic with higher rigidity in the circumferential direction compared to the meridional direction. ACUS-OCE is a promising non-invasive method to quantify the biomechanical changes in scleral tissue for future studies involving myopia treatments., Funding: Funding: Horizon 2020 Framework Programme European Project Imcustomeye (H2020-ICT-2017 Ref. 779960); European Research Council (2018-ADG-SILKEYE-833106); Spanish Government PID2020-115191RB-I00; NIH NIE P30EY 001319; Unrestricted Funds Research to Prevent Blindness, NY; Spanish Government10.13039/100014440 (CSIC JAE Intro Fellowship); L'Oréal-UNESCO “For Women in Science” Spain; Spanish Government Juan de la Cierva-Incorporation Fellowship (IJC2018-037508-I); Fundacja na rzecz Nauki Polskiej (MAB/2019/12); National Agency for Academic Exchange, Polish Government (NAWA ULAM/2020/1/00176), Peer reviewed
DIGITAL.CSIC. Repositorio Institucional del CSIC
Publicación Artículo científico (JournalArticle)

Revealing regional variations in scleral shear modulus in a rabbit eye model using multi-directional ultrasound optical coherence elastography

  • Villegas, Lupe
  • Zvietcovich, Fernando
  • Marcos, Susana
  • Birkenfeld, Judith S.
12 pags., 7 figs., The mechanical properties of the sclera play a critical role in supporting the ocular structure and maintaining its shape. However, non-invasive measurements to quantify scleral biomechanics remain challenging. Recently introduced multi-directional optical coherence elastography (OCE) combined with an air-coupled ultrasound transducer for excitation of elastic surface waves was used to estimate phase speed and shear modulus in ex vivo rabbit globes (n = 7). The scleral phase speed (12.1 ± 3.2 m/s) was directional-dependent and higher than for corneal tissue (5.9 ± 1.4 m/s). In the tested locations, the sclera proved to be more anisotropic than the cornea by a factor of 11 in the maximum of modified planar anisotropy coefficient. The scleral shear moduli, estimated using a modified Rayleigh-Lamb wave model, showed significantly higher values in the circumferential direction (65.4 ± 31.9 kPa) than in meridional (22.5 ± 7.2 kPa); and in the anterior zone (27.3 ± 9.3 kPa) than in the posterior zone (17.8 ± 7.4 kPa). The multi-directional scanning approach allowed both quantification and radial mapping of estimated parameters within a single measurement. The results indicate that multi-directional OCE provides a valuable non-invasive assessment of scleral tissue properties that may be useful in the development of improved ocular models, the evaluation of potential myopia treatment strategies, and disease characterization and monitoring., Open Access funding provided thanks to the CRUE-CSIC agreement with Springer Nature. This work has been funded by Spanish Government Grant (PRE2018-086169, FIS2017-84753-R, PID2020-115191RB-I00); European Project H2020 IMCUSTOMEYE (779960); European Research Council (2018-ADG-SILKEYE-833106); Ayudas Ramón y Cajal (RYC2022-037910-I); L’Oréal-UNESCO “For Women in Science” Spain; NIH NEI P30EY 001319; Unrestricted Funds Research to Prevent Blindness., Peer reviewed
DIGITAL.CSIC. Repositorio Institucional del CSIC
Publicación Artículo científico (JournalArticle)

Effects of Different Scleral Photo-Crosslinking Modalities on Scleral Stiffness and Hydration

  • Villegas, Lupe
  • Germann, James
  • Marcos, Susana
9 pags., 7 figs., The purpose of this study was to evaluate the biomechanical and hydration differences in scleral tissue after two modalities of collagen cross-linking., Supported by Spanish Government Grant (PRE2018-086169 and FIS2017-84753-R); European Research Council (2018-ADGSILKEYE-833106); NIH NEI P30EY 001319; and Unrestricted Funds Research to Prevent Blindness, NY., Peer reviewed
DIGITAL.CSIC. Repositorio Institucional del CSIC
Publicación Artículo científico (JournalArticle)

A simple computational model for scleral stiffness assessments via air-puff deformation OCT

  • Hoz, A. de la
  • Villegas, Lupe
  • Marcos, Susana
  • Birkenfeld, Judith S.
13 pags., 11 figs., 2 tabs., Introduction: The mechanical properties of the sclera are related to its structural function, and changes to these properties are believed to contribute to pathologies such as myopia. Air-puff deformation imaging is a tool that uses an imaging system coupled with an air-puff excitation source to induce and measure deformation in a tissue in vivo. Typically used for the study of the cornea's mechanical properties and IOP, this tool has been proposed as a method to evaluate scleral stiffness. Methods: In this work, we present a computational model of the rabbit eye to assess scleral deformation under air-puff. Parametric studies were conducted to evaluate the effects of material properties, intraocular pressure, and other parameters on the deformation response. Output from the model was also compared to experimental measurements of air-puff deformation in rabbit eyes under varying IOP. Results: Central deformation response was found to be most influenced by material properties of the sclera (at site of air-puff and posterior), thickness, and IOP, whereas deformation profile was most influenced by material properties. Experimental and simulated IOP dependence were found to be similar (RMSE = 0.13 mm). Discussion: Scleral APDI could be a useful tool for quick in vivo assessment of scleral stiffness., The author(s) declare that financial support was received for the research, authorship, and/or publication of this article. Spanish Government Grant (PRE2018-086169, FIS2017-84753-R, PID2020115191RB-I00); European Project H2020 IMCUSTOMEYE (779960); European Research Council (2018-ADG-SILKEYE833106); Ayudas Ramón y Cajal (RYC2022-037910-I); L’OréalUNESCO “For Women in Science” Spain; NIH NEI P30EY 001319; Unrestricted Funds Research to Prevent Blindness, NY, Peer reviewed
DIGITAL.CSIC. Repositorio Institucional del CSIC
Publicación Artículo científico (JournalArticle)

Comparative Analysis of Silk Fibroin Membranes across Cross-Linking Methods: Processing and Characterization

  • Gutierrez-Contreras, R.
  • Fernández-Gutiérrez, Mar
  • Olalla-Pérez, Paula
  • Hoz, A. de la
  • Marcos, Susana
10 pages, 5 figures, 5 tables, Silk fibroin (SF) extracted from silkworm silk can be transformed into transparent membranes with well-suited physical properties for ophthalmic applications. There is ample literature on the fabrication and characterization of SF-based membranes; however, the use of diverse SF extraction protocols and characterization methods or their settings makes it difficult to compare different silk membrane properties across studies. In this work, we fabricated 10 families of SF-based membranes by physical cross-linking and one non-cross-linked as a control. We evaluated transparency (ranging from 84.5 to 95.3% in the visible spectrum), enzyme stability (from 24 h to 200 days in protease XIV), decomposition temperature (280-290 °C), water uptake (40-60%), Young's modulus (8-30 MPa), roughness (1.6-22.7 nm), and FTIR spectra for the secondary structure. We found correlation between water uptake and the Young's modulus (the lower the water uptake, the higher the Young's modulus) and a relationship between membrane stability in protease XIV and the secondary structure of the proteins. Higher surface roughness and faster degradation were found in membranes cross-linked with polyethylene glycol, and conversely, lower roughness and lower degradation were found in methanol, ethanol, or isopropanol crossed-link membranes. This ample compilation of materials and their characterization will aid in the selection of a SF-based material according to the needs of the application., This work was supported by the European Research Council (2018-ADG-SILKEYE-833106). The authors would also liketo thank the Optical Spectroscopies on Plasmonic and Semiconductor Nanostructures Group (IEM-CSIC) and the Laser Processing Group (IO-CSIC) for FTIR and trans-mittance measurements, respectively., Peer reviewed
DIGITAL.CSIC. Repositorio Institucional del CSIC
Publicación Artículo científico (JournalArticle)

Demonstration of femtosecond laser induced refractive index change in silk-fibroin hydrogels

  • Islam, Quazi Rushnan
  • Gutiérrez-Contreras, R.
  • Marcos, Susana
  • Knox, Wayne H.
12 pages, 7 figures, 2 tables, We present induced refractive index changes in biocompatible silk fibroin hydrogels using two different femtosecond laser systems: one using 400 nm at 80 MHz and the other employing 517 nm at 8.3 MHz. Both modalities produced significant index changes, demonstrating the potential to create custom refractive correctors. Additionally, the biocompatibility and environmentally friendly properties of silk-fibroin make it an ideal platform for developing new types of intraocular implants that incorporate tunable refractive corrections., National Eye Institute (P30EY 001319); Research to Prevent Blindness; European Research Council (2018-ADG-SILKEYE-833106)., Peer reviewed
DIGITAL.CSIC. Repositorio Institucional del CSIC
Publicación Artículo científico (JournalArticle)

In vivo assessment of multifocal contact lens fitting using anterior segment optical coherence tomography

  • Rodríguez-López, Víctor
  • Esteban-Ibañez, Eduardo
  • González-Ramos, Ana M.
  • Marcos, Susana
  • Martínez-Enríquez, Eduardo
8 pages, 7 figures, Multifocal contact lenses (MCLs) are designed to provide near vision functionality in presbyopia. They rely on the correct deployment of the multifocal power profile on the cornea and on the optical interactions between the MCL and the eye. The contact lens profile on the eye and the potential conformity to the cornea was evaluated using custom-developed spectral anterior segment Optical Coherence Tomography (OCT). OCT images were obtained from one eye of 13 subjects (age: 35.7 ± 13.8 years) with naked eyes and with MCLs on the eye. All eyes were measured with the same MCLs: 1-Day Acuvue® Moist Multifocal with low, medium, and high additions. Images were processed using custom routines for segmentation, fan distortion correction, 3D model construction and quantification. The radius of curvature of the anterior and posterior surfaces of the MCLs (RAL and RPL, respectively) and the anterior surface of the naked cornea (RAC) were obtained within a 3-mm diameter central area (addition area) and within a 3-6 mm peripheral ring. The power profile was also obtained by a ray-tracing analysis. RAC ranged from 7.5 to 8.2 mm across subjects (mean 8.02 ± 0.22 mm). RAC was correlated with RPL and RAL in the periphery (r > 0.80, p < 0.05) and in the addition (r > 0.79, p < 0.05) areas for the three MCL additions. The average power profile exhibited a slightly lower addition than that reported by the manufacturer (1.32, 1.36, and 1.83 D for low, medium, and high additions), but similar to other off-eye reports in the literature. OCT equipped with quantification tools allows to study the fitting of MCLs to the eye in vivo. It was found that, overall, soft MCLs conform to the underlying cornea, in both the central and the peripheral areas, and the central near add is provided as expected., This work was supported by La Caixa Foundation [LCF/TR/CI22/ 52660002, LCF/TR/CI24/56010018]; Spanish Research Agency grant [CPP2021-008388D, PID2023-152641OA-I00]; Madrid Regional Government [IND2020/BMD-17442, TEC-2024/COM-322]; National Institutes of Health, National Eye Institute [NEI R01-EY035009, P30EY 001319]; European Research Council 2018-AdG-Silkeye-833106; Unrestricted Funds Research to Prevent Blindness; 2023 Leonardo Grant for Researchers and Cultural Creators, BBVA Foundation; Spanish government grant [RYC2022-038195-I, MCIN/AEI and FSE+]., Peer reviewed
DIGITAL.CSIC. Repositorio Institucional del CSIC
Publicación Artículo científico (JournalArticle)

Estimation of scleral mechanical properties from air-puff optical coherence tomography

  • Bronte-Ciriza, David
  • Birkenfeld, Judith S.
  • Hoz, A. de la
  • Curatolo, Andrea
  • Germann, James
  • Villegas, Lupe
  • Varea, Alejandra
  • Martínez-Enríquez, Eduardo
  • Marcos, Susana
19 pages, 7 figures, 2 tables, We introduce a method to estimate the biomechanical properties of the porcine sclera in intact eye globes ex vivo, using optical coherence tomography that is coupled with an air-puff excitation source, and inverse optimization techniques based on finite element modeling. Air-puff induced tissue deformation was determined at seven different locations on the ocular globe, and the maximum apex deformation, the deformation velocity, and the arc-length during deformation were quantified. In the sclera, the experimental maximum deformation amplitude and the corresponding arc length were dependent on the location of air-puff excitation. The normalized temporal deformation profile of the sclera was distinct from that in the cornea, but similar in all tested scleral locations, suggesting that this profile is independent of variations in scleral thickness. Inverse optimization techniques showed that the estimated scleral elastic modulus ranged from 1.84 ± 0.30 MPa (equatorial inferior) to 6.04 ± 2.11 MPa (equatorial temporal). The use of scleral air-puff imaging holds promise for non-invasively investigating the structural changes in the sclera associated with myopia and glaucoma, and for monitoring potential modulation of scleral stiffness in disease or treatment., European Research Council (2018-ADG-SILKEYE-833106); Horizon 2020 Framework Programme European Project Multiply (H-2020-MSCACOFUND-2015 Ref. 713694); Spanish Government (FIS2017-84753-R); Horizon 2020 Framework Programme European Project Imcustomeye (H2020-ICT-2017 Ref. 779960); Spanish Government (CSIC JAE Intro Fellowship); L’Oréal-UNESCO “For Women in Science” Spain; Spanish Government Juan de la Cierva-Incorporation Fellowship (IJC2018-037508-I); Fundacja na rzecz Nauki Polskiej (MAB/2019/12); National Agency for Academic Exchange, Polish Government (NAWA ULAM/2020/1/00176), Peer reviewed
DIGITAL.CSIC. Repositorio Institucional del CSIC
Publicación Artículo científico (JournalArticle)

Photobonding of silk fibroin-based hydrogels to rabbit corneas

  • Gutiérrez-Contreras, R.
  • Gallego-Muñoz, Patricia
  • Hoz, A. de la
  • Fernández-Gutiérrez, Mar
  • Kochevar, Irene E.
  • Martínez-García, M. Carmen
  • Marcos, Susana
11 pages, 8 figures . -- Sec. Tissue Engineering and Regenerative Medicine, Introduction: Corneal abrasions are common ocular injuries characterized by the loss of epithelial cells. Severe cases are often treated with amniotic membrane transplantation. However, as an allogenic tissue, it can trigger immune responses, it is scarce and costly, and may require suturing to the cornea. In this study, we propose and evaluate two silk fibroin-based hydrogels implanted in rabbit corneas with a sutureless photobonding technique as a surrogate for the amniotic membrane in corneal wound healing.Methods: Silk fibroin-based hydrogels were developed with polyethylene glycol (PEG) 300 or 3350. The hydrogels were stained with 0.01% Rose Bengal and photobonded to ex vivo de-epithelialized rabbit corneal strips using a custom-developed irradiation system (532 nm; 0.13 or 0.15 W/cm2 irradiance for 6.6 min). Bonding strength after 24 and 72 h under hydrated conditions was measured using a uniaxial stretcher, with five samples per experiment. An in vivo proof of concept study was also performed: hydrogels were implanted in four anesthetized rabbits that were euthanized immediately after photobonding for bonding assessment after 24 and 72 h in hydration. Two additional rabbits received in vivo implants, were clinically monitored for 15 and 30 days, and euthanized for histological evaluation.Results: Bonding strengths measured 24- or 72-h after irradiation at 0.13 or 0.15 W/cm2 of 532 nm light reached 2–3 N/cm2 for both types of Rose Bengal-stained hydrogels. In vivo bonding strength was consistent with the ex vivo results. At 15 and 30 days after the procedure, the corneas exhibited complete re-epithelialization beneath the hydrogel.Conclusion: Silk fibroin-based hydrogels can be successfully bonded to ex vivo rabbit corneas using a sutureless photobonding technique, achieving high bonding strength. The in vivo proof-of-concept study demonstrated the feasibility of the surgical procedure and confirmed corneal re-epithelialization., The author(s) declared that financial support was received for this work and/or its publication. This work was supported by the European Research Council (2018-ADG-SILKEYE-833106)., Peer reviewed
DIGITAL.CSIC. Repositorio Institucional del CSIC
Publicación Artículo científico (JournalArticle)

Reconstruction of the crystalline lens full-geometry from OCT images acquired with off-axis viewing

  • Peña, Álvaro de la
  • Rodriguez-Sanchez, Javier
  • Vadillo, Estela
  • Talaván-González, Celia
  • Carreño, Ester
  • Castro, Alberto de
  • Marcos, Susana
  • Martínez-Enríquez, Eduardo
The crystalline lens of the eye is an optical structure that, together with the cornea, focuses images onto the retina. In a young and healthy eye, the lens is transparent and adjusts its shape to focus on near and distant objects (accommodation). With age, it loses this flexibility (presbyopia) and may later become opaque (cataract). Understanding the full three-dimensional geometry of the crystalline lens is essential for studying age-related lens growth and accommodation mechanism, as well as for the customized design and selection of intraocular lenses the for implantation in cataract surgery. While Optical Coherence Tomography (OCT) allows imaging of the central lens region visible through the pupil, conventional in vivo measurements cannot capture the full lens shape, particularly at the periphery, due to iris obstruction. In this study, we present a novel method to reconstruct the full three-dimensional shape of the crystalline lens by combining OCT images acquired with off-axis illumination at different angles. Using this approach, full lens reconstructions were achieved in eight subjects, and key geometrical parameters - diameter, volume, and surface area- were quantified, showing strong positive correlations with age. Comparisons with estimates derived from pupil-limited regions showed strong agreement, thereby validating these estimation methods., Open Access funding provided thanks to the CRUE-CSIC agreement with Springer Nature. This study has been supported by Spanish Government grant PID2023-152641OA-I00; Autonomous Community of Madrid (CAM) grant TEC-2024-COM-322; Consejo Superior de Investigaciones Científicas (CSIC), grant I-LINK 2025; 2023 Leonardo Grant for Researchers and Cultural Creators, BBVA Foundation; RYC2022-038195-I, MCIN/AEI and FSE+; NIH/NEI Grant EY035009; NIH/NEI P30EY001319; Spanish government grant PID2020-115191 RB-100; Research to Prevent Blindness Unrestricted Funds;2018-ADG-SILKEYE-833106. The funding organizations had no role in the design or conduct of this research., Peer reviewed