Pasar al contenido principal

OPTICA ADAPTATIVA PORTATIL PARA APLICACIONES VISUALES

PID2019-105684RB-I00

•
Nombre agencia financiadora Agencia Estatal de Investigación
Acrónimo agencia financiadora AEI
Programa Programa Estatal de I+D+i Orientado a los Retos de la Sociedad
Convocatoria Proyectos de I+D+i (Generación de Conocimiento y Retos Investigación)
Año convocatoria 2019
Plan Estatal 2017-2020 Plan Estatal de Investigación Científica y Técnica y de Innovación
Centro beneficiario UNIVERSIDAD DE MURCIA

Resultados relacionados

Resultados totales (Incluyendo duplicados): 3
Encontrada(s) 1 página(s)

DIGITAL.CSIC. Repositorio Institucional del CSIC
Publicación Artículo científico (JournalArticle)

Simulating Outcomes of Cataract Surgery: Important Advances in Ophthalmology

  • Marcos, Susana
  • Martínez-Enríquez, Eduardo
  • Viñas, María
  • Castro, Alberto de
  • Dorronsoro, Carlos
  • Bang, Seung Pil
  • Yoon, Geunyoung
  • Artal, Pablo
32 pags., 10 figs., As the human eye ages, the crystalline lens stiffens (presbyopia) and opacifies (cataract), requiring its replacement with an artificial lens [intraocular lens (IOL)]. Cataract surgery is the most frequently performed surgical procedure in the world. The increase in IOL designs has not been paralleled in practice by a sophistication in IOL selection methods, which rely on limited anatomical measurements of the eye and the surgeon's interpretation of the patient's needs and expectations. We propose that the future of IOL selection will be guided by 3D quantitative imaging of the crystalline lens to map lens opacities, anticipate IOL position, and develop fully customized eye models for ray-tracing-based IOL selection. Conversely, visual simulators (in which IOL designs are programmed in active elements) allow patients to experience prospective vision before surgery and to make more informed decisions about which IOL to choose. Quantitative imaging and optical and visual simulations of postsurgery outcomes will allow optimal treatments to be selected for a patient undergoing modern cataract surgery., The authors have received funding from the following sources: H2020-MSCA-ITN-2015- 675137 IMCUSTOMEYE (S.M.); ERC-2011-AdG-294099 PRESBYOPIA (S.M.); ERC-PoCOCT4IOL (S.M.); ERC-PoC-SimVisSim (S.M.); ERC-2018-AdG-833106-SilkEye (S.M.) and ERC-2013-AdG-339228 SEECAT (P.A.); Spanish Agencia Estatal de Investigación FIS2017- 84753-R (S.M.) and PID2019-105684RB-I00 (P.A.); Fundación Séneca-Agencia de Ciencia y Tecnología de la Región de Murcia 19897/GERM/15 (P.A.); National Institutes of Health/National Eye Institute (G.Y.); Research to Prevent Blindness (G.Y.); and NYSTAR/CEIS/CoE (G.Y.).
DIGITAL.CSIC. Repositorio Institucional del CSIC
Publicación Artículo científico (JournalArticle)

Adaptive optics visual simulators: a review of recent optical designs and applications

  • Marcos, Susana
  • Artal, Pablo
  • Atchison, David A.
  • Hampson, Karen
  • Legras, R.
  • Lundström, L.
  • Yoon, Geunyoung
25 pags., 14 figs., In their pioneering work demonstrating measurement and full correction of the eye’s optical aberrations, Liang, Williams and Miller, [JOSA A 14, 2884 (1997)] showed improvement in visual performance using adaptive optics (AO). Since then, AO visual simulators have been developed to explore the spatial limits to human vision and as platforms to test non-invasively optical corrections for presbyopia, myopia, or corneal irregularities. These applications have allowed new psychophysics bypassing the optics of the eye, ranging from studying the impact of the interactions of monochromatic and chromatic aberrations on vision to neural adaptation. Other applications address new paradigms of lens designs and corrections of ocular errors. The current paper describes a series of AO visual simulators developed in laboratories around the world, key applications, and current trends and challenges. As the field moves into its second quarter century, new available technologies and a solid reception by the clinical community promise a vigorous and expanding use of AO simulation in years to come., National Eye Institute (P30EY 001319, R01EY014999, R01EY034151); Agencia Estatal de Investigación (PID2019-105684RB-I00, PID2020-115191RB-I00); Vetenskapsrådet (2019-05354); Engineering and Physical Sciences Research Council (G015473/1); Research to Prevent Blindness (N/A Unrestricted funds (UoR)); H2020 Marie SkłodowskaCurie Actions (#675137); Empire State Development’s Division of Science, Technology and Innovation (CEIS #2130C002).
DIGITAL.CSIC. Repositorio Institucional del CSIC
Publicación Artículo científico (JournalArticle)

Visual simulation of intraocular lenses: technologies and applications [Invited]

  • Marcos, Susana
  • Artal, Pablo
  • Lundström, Linda
  • Yoon, Geunyoung
18 pages, 7 figures, Cataract surgery requires selecting an intraocular lens (IOL), whose design affects visual outcomes. Traditional IOL evaluation relies on optical models and bench testing, but these methods fall short in simulating perceptual factors crucial to patient experience. Visual simulators, based on different principles including adaptive optics, temporal multiplexing or physical projection of the IOLs, now allow patients and clinicians to preview and compare different IOL designs preoperatively. By simulating real-world interactions of the eye's optics and the visual system with IOLs, these simulators enhance the patient decision-making process, enable personalized cataract surgery, and can aid in regulatory assessments of IOLs by incorporating pre-operative patient-reported visual outcomes. Visual simulators incorporate deformable mirrors, spatial light modulators and optotunable lenses as dynamic elements to simulate monofocal, multifocal and extended depth-of-focus IOLs, including newer designs aimed at improving contrast sensitivity, expanding depth of focus, and minimizing visual disturbances. With ongoing advancements, these simulators hold potential for transforming IOL design, regulatory processes, and patient care by providing realistic and patient-centered visual assessments, ultimately leading to more successful, individualized surgical outcomes., Agencia Estatal de Investigación (PID2020-115191RB-I00, PID2019-105684RB-I00); European Commission (H2020 ITN Network Marie Sklodowska-Curie #675137); National Eye Institute (P30EY001319, R01EY014999, R01EY034151, R01EY035009, P30EY007551); Empire State Development (CEIS #2130C00); Research to Prevent Blindness (Unrestricted Funds. Department of Ophthalmology); Vetenskapsrådet (2019-05354); Meta Reality Labs (Unrestricted gifts); RxSight (Unrestricted gift)., Peer reviewed