Pasar al contenido principal

Resultados relacionados

Resultados totales (Incluyendo duplicados): 12
Encontrada(s) 1 página(s)

RUA. Repositorio Institucional de la Universidad de Alicante
Publicación Otros (Other)

Disparity between central and peripheral refraction inheritance in twins

  • Pusti, Dibyendu
  • Benito, Antonio
  • Madrid-Valero, Juan J.
  • Ordoñana, Juan R.
  • Artal, Pablo
The last decades have witnessed a sudden increase in myopia incidence among youngsters that have been related to modern lifestyle along with the use of emerging technologies affecting visual exposure. Increasing exposures to known risk factors for myopia, such as time spent indoors, close-distance work, or low-light conditions are thought to be responsible for this public health issue. In most cases, development of myopia is secondary to a vitreous chamber enlargement, although the related mechanisms and the potential interaction between central and peripheral retinal area remain unclear. For a better understanding, we performed a classical twin study where objective refractive error along 70° of horizontal retinal arc was measured in 100 twin pairs of university students, 78% of which showed manifest myopia. We found the variance of shared environmental origin (range 0.34 to 0.67) explained most of the objective refractive error variance within central 42° of the retina (22° temporal to 19° nasal), whereas additive genetic variance (range 0.34 to 0.76) was predominant in the peripheral retinal areas measured. In this sample of millennial university students, with a large prevalence of myopia, environmental exposures were mostly responsible for inter-individual variation in the retinal horizontal area surrounding the macula, while their relative weight on phenotypic variance was gradually descending, and replaced by the variance of genetic origin, towards the retinal periphery.
DIGITAL.CSIC. Repositorio Institucional del CSIC
Publicación Artículo científico (JournalArticle)

Morphological changes of human crystalline lens in myopia

  • Muralidharan, Geethika
  • Martínez-Enríquez, Eduardo
  • Birkenfeld, Judith S.
  • Velasco Ocaña, Miriam
  • Pérez Merino, Pablo
  • Marcos, Susana
12 pags., 3 figs., 2 tabs., Ocular biometric parameters, including full shape crystalline lens, were assessed in myopes and emmetropes using 3-D optical coherence tomography. The anterior chamber depth, the radius of the curvature of the anterior cornea, anterior lens, and posterior lens, lens thickness, lens equatorial diameter, surface area, equatorial position, volume, and power, were evaluated as functions of refractive errors and axial lengths while controlling for age effects. The crystalline lens appears to change with myopia consistent with lens thinning, equatorial, and capsular stretching while keeping constant volume. Axial elongation appears counteracted by a crystalline lens power reduction, while corneal power remains unaffected., European Research Council (ERC-2011-AdG- 294099, H-2020-MSCA-COFUND-2015 Ref. 713694, H-2020-MSCA-ITN-2015-ETN-MyFUN No: 675137); Ministerio de Ciencia, Innovación y Universidades (FIS 2017-84753 R MYOPT).
DIGITAL.CSIC. Repositorio Institucional del CSIC
Publicación Artículo científico (JournalArticle)

Crystalline lens gradient refractive index distribution in the guinea pig

  • Castro, Alberto de
  • Martínez-Enríquez, Eduardo
  • Pérez Merino, Pablo
  • Velasco Ocaña, Miriam
  • Revuelta, Luis
  • McFadden, Sally A.
  • Marcos, Susana
8 pags., 6 figs., Purpose: The crystalline lens undergoes morphological and functional changes with age and may also play a role in eye emmetropisation. Both the geometry and the gradient index of refraction (GRIN) distribution contribute to the lens optical properties. We studied the lens GRIN in the guinea pig, a common animal model to study myopia. Methods: Lenses were extracted from guinea pigs (Cavia porcellus) at 18 days of age (n = 4, three monolaterally treated with negative lenses and one untreated) and 39 days of age (n = 4, all untreated). Treated eyes were myopic (−2.07 D on average) and untreated eyes hyperopic (+3.3 D), as revealed using streak retinoscopy in the live and cyclopeged animals. A custom 3D spectral domain optical coherence tomography (OCT) system (λ = 840 nm, Δλ = 50 nm) was used to image the enucleated crystalline lens at two orientations. Custom algorithms were used to estimate the lens shape and GRIN was modelled with four variables that were reconstructed using the OCT data and a minimisation algorithm. Ray tracing was used to calculate the optical power and spherical aberration assuming a homogeneous refractive index or the estimated GRIN. Results: Guinea pig lenses exhibited nearly parabolic GRIN profiles. When comparing the two age groups (18- and 39 day-old) there was a significant increase in the central thickness (from 3.61 to 3.74 mm), and in the refractive index of the surface (from 1.362 to 1.366) and the nucleus (from 1.443 to 1.454). The presence of GRIN shifted the spherical aberration (−4.1 µm on average) of the lens towards negative values. Conclusions: The guinea pig lens exhibits a GRIN profile with surface and nucleus refractive indices that increase slightly during the first days of life. GRIN plays a major role in the lens optical properties and should be incorporated into computational guinea pig eye models to study emmetropisation, myopia development and ageing., This work was supported by European Research Council (ERC) Grant Agreement ERC-2011-AdC- 294099; ERC under the European Union’s Horizon 2020 research and innovation programme (H2020-MSCA COFUND-2015 FP-713694, MULTIPLY) and under grant agreement No 779960, IMCUSTOMEYE and No 675137 (MyFUun MSCA ITN); Spanish Government Grant FIS2017-84753-R; Hunter Medical Research Institute G1400967 and the University of Newcastle (FVG 1031537 and SSP).
DIGITAL.CSIC. Repositorio Institucional del CSIC
Publicación Contribución de congreso (ConferenceOutput)

Detecting deformation asymmetries on multiple meridians in an ex vivo keratoconic eye model

  • Curatolo, Andrea
  • Birkenfeld, Judith S.
  • Martínez-Enríquez, Eduardo
  • Germann, James
  • Palací, J.
  • Pascual, Daniel
  • Muralidharan, Geethika
  • Eliasy, A.
  • Abass, A.
  • Solarski, J.
  • Karnowski, Karol
  • Wojtkowski, Maciej
  • Elsheikh, A.
  • Marcos, Susana
1 pag. -- This is a 2020 ARVO Annual Meeting abstract., Support European Project COFUND Multiply H-2020-MSCA-COFUND-2015 Ref. 713694; European Project IMCUSTOMEYE H2020-ICT-2017 Ref. 779960; European Project MyFUN H2020-MSCA-ITN-2015 Ref. 675137; Spanish government grant FIS2017-84753-R, Peer reviewed
DIGITAL.CSIC. Repositorio Institucional del CSIC
Publicación Contribución de congreso (ConferenceOutput)

3D OCT-based geometrical changes of human crystalline lenses during simulated accommodation in a lens stretcher

  • Martínez-Enríquez, Eduardo
  • Castro, Alberto de
  • Mohamed, Ashik
  • Maceo Heilman, B.
  • Williams, S.
  • Nandyala, S.
  • Ruggeri, Marco
  • Parel, J. M. A.
  • Augusteyn, Robert
  • Ho, Arthur
  • Manns, Fabrice
  • Marcos, Susana
This is a 2020 ARVO Annual Meeting abstract., Support European Project MyFUN H2020-MSCA-ITN-2015 Ref. 675137, European Project IMCUSTOMEYE H2020-ICT-2017 Ref. 779960​, European Project SILKEYE H2020-ERC-2018-ADG Ref. 833106, European Project COFUND Multiply H-2020-MSCA-COFUND-2015 Ref. 713694, Spanish government grant FIS2017-84753-R, NEI Grants: R01EY021834, F31EY021444 (Maceo), P30EY14801 (Center Grant); the Florida Lions Eye Bank; Research to Prevent Blindness; Drs. KR Olsen and ME Hildebrandt, Drs. Raksha Urs and Aaron Furtado, the Henri and Flore Lesieur Foundation (JMP); Hyderabad Eye Research Foundation., Peer reviewed
DIGITAL.CSIC. Repositorio Institucional del CSIC
Publicación Contribución de congreso (ConferenceOutput)

Vision with Multifocal contact lenses in Myopes and Presbyopes

  • Vedhakrishnan, Shrilekha
  • Viñas, María
  • Casado-Moreno, Pilar
  • Benedi, Clara
  • Dorronsoro, Carlos
  • Marcos, Susana
ARVO Annual Meeting Abstract , June 2020, Spanish government grant FIS2017-84753-R, European Project PRESBYOPIA ERC-2011-AdG Ref. 294099, European Project MyFUN H2020MSCA-ITN-2015 Ref. 675137, Peer reviewed
DIGITAL.CSIC. Repositorio Institucional del CSIC
Publicación Contribución de congreso (ConferenceOutput)

Detecting deformation asymmetries on multiple meridians in an ex vivo keratoconic eye model

  • Curatolo, Andrea
  • Birkenfeld, Judith S.
  • Martínez-Enríquez, Eduardo
  • Germann, James
  • Palací, J.
  • Pascual, Daniel
  • Muralidharan, Geethika
  • Eliasy, A.
  • Abass, A.
  • Solarski, J.
  • Karnowski, Karol
  • Wojtkowski, Maciej
  • Elsheikh, A.
  • Marcos, Susana
ARVO Annual Meeting Abstract, Support European Project COFUND Multiply H-2020-MSCA-COFUND-2015 Ref. 713694; European Project IMCUSTOMEYE H2020-ICT-2017 Ref. 779960; European Project MyFUN H2020-MSCA-ITN-2015 Ref. 675137; Spanish government grant FIS2017-84753-R, Peer reviewed
DIGITAL.CSIC. Repositorio Institucional del CSIC
Publicación Artículo científico (JournalArticle)

Simulating Outcomes of Cataract Surgery: Important Advances in Ophthalmology

  • Marcos, Susana
  • Martínez-Enríquez, Eduardo
  • Viñas, María
  • Castro, Alberto de
  • Dorronsoro, Carlos
  • Bang, Seung Pil
  • Yoon, Geunyoung
  • Artal, Pablo
32 pags., 10 figs., As the human eye ages, the crystalline lens stiffens (presbyopia) and opacifies (cataract), requiring its replacement with an artificial lens [intraocular lens (IOL)]. Cataract surgery is the most frequently performed surgical procedure in the world. The increase in IOL designs has not been paralleled in practice by a sophistication in IOL selection methods, which rely on limited anatomical measurements of the eye and the surgeon's interpretation of the patient's needs and expectations. We propose that the future of IOL selection will be guided by 3D quantitative imaging of the crystalline lens to map lens opacities, anticipate IOL position, and develop fully customized eye models for ray-tracing-based IOL selection. Conversely, visual simulators (in which IOL designs are programmed in active elements) allow patients to experience prospective vision before surgery and to make more informed decisions about which IOL to choose. Quantitative imaging and optical and visual simulations of postsurgery outcomes will allow optimal treatments to be selected for a patient undergoing modern cataract surgery., The authors have received funding from the following sources: H2020-MSCA-ITN-2015- 675137 IMCUSTOMEYE (S.M.); ERC-2011-AdG-294099 PRESBYOPIA (S.M.); ERC-PoCOCT4IOL (S.M.); ERC-PoC-SimVisSim (S.M.); ERC-2018-AdG-833106-SilkEye (S.M.) and ERC-2013-AdG-339228 SEECAT (P.A.); Spanish Agencia Estatal de Investigación FIS2017- 84753-R (S.M.) and PID2019-105684RB-I00 (P.A.); Fundación Séneca-Agencia de Ciencia y Tecnología de la Región de Murcia 19897/GERM/15 (P.A.); National Institutes of Health/National Eye Institute (G.Y.); Research to Prevent Blindness (G.Y.); and NYSTAR/CEIS/CoE (G.Y.).
DIGITAL.CSIC. Repositorio Institucional del CSIC
Publicación Artículo científico (JournalArticle)

Functional integration of eye tissues and refractive eye development: Mechanisms and pathways

  • Summers, Jody A.
  • Schaeffel, Frank
  • Marcos, Susana
  • Wu, Hao
  • Tkatchenko, Andrei V.
15 pags., 3 figs., Refractive eye development is a tightly coordinated developmental process. The general layout of the eye and its various components are established during embryonic development, which involves a complex cross-tissue signaling. The eye then undergoes a refinement process during the postnatal emmetropization process, which relies heavily on the integration of environmental and genetic factors and is controlled by an elaborate genetic network. This genetic network encodes a multilayered signaling cascade, which converts visual stimuli into molecular signals that guide the postnatal growth of the eye. The signaling cascade underlying refractive eye development spans across all ocular tissues and comprises multiple signaling pathways. Notably, tissue-tissue interaction plays a key role in both embryonic eye development and postnatal eye emmetropization. Recent advances in eye biometry, physiological optics and systems genetics of refractive error have significantly advanced our understanding of the biological processes involved in refractive eye development and provided a framework for the development of new treatment options for myopia. In this review, we summarize the recent data on the mechanisms and signaling pathways underlying refractive eye development and discuss new evidence suggesting a wide-spread signal integration across different tissues and ocular components involved in visually guided eye growth., This work was supported in part by the National Institutes of Health grants R01EY09391 (JAS), R01EY023839 (AVT), P30EY019007 (Core Support for Vision Research received by the Department of Ophthalmology, Columbia University), Research to Prevent Blindness (Unrestricted funds received by the Department of Ophthalmology, Columbia University), European Commission grant H2020-MSCA-ITN-2015-675137 (SM), European Research Council grant ERC-2018-ADG-SILKEYE-833106 (SM) and Spanish Government grant FIS 2017-84753-R (SM).
DIGITAL.CSIC. Repositorio Institucional del CSIC
Publicación Artículo científico (JournalArticle)

Foveal and peripheral visual quality and accommodation with multifocal contact lenses

  • Papadogiannis, Petros
  • Romashchenko, Dmitry
  • Vedhakrishnan, Shrilekha
  • Persson, Britta
  • Pettersson, A.L.
  • Marcos, Susana
  • Lundstrom, L.
11 pags., 9 figs., 3 tabs., Multifocal contact lenses are increasingly popular interventions for controlling myopia. This study presents the short-termeffects of multifocal contact lenses on foveal and peripheral vision. TheMiSight contact lenses designed to inhibit myopia progression and the 1-Day Acuvue Moist contact lenses designed for presbyopia were investigated. The MiSight produced similar foveal results to spectacles despite the increased astigmatism and coma. The MiSight also reduced the low-contrast resolution acuity in the periphery, despite no clear change in relative peripheral refraction. When compared with spectacles, Acuvue Moist decreased accommodative response and reduced foveal high- and low-contrast resolution acuity, whereas peripheral thresholds were more similar to those of spectacles. The most likely treatment property for myopia control by theMiSight is the contrast reduction in the peripheral visual field and the changed accommodation., European Union’s H2020 ITN Network “MyFUN” under Marie Skłodowska-Curie (675137).
DIGITAL.CSIC. Repositorio Institucional del CSIC
Publicación Artículo científico (JournalArticle)

Adaptive optics visual simulators: a review of recent optical designs and applications

  • Marcos, Susana
  • Artal, Pablo
  • Atchison, David A.
  • Hampson, Karen
  • Legras, R.
  • Lundström, L.
  • Yoon, Geunyoung
25 pags., 14 figs., In their pioneering work demonstrating measurement and full correction of the eye’s optical aberrations, Liang, Williams and Miller, [JOSA A 14, 2884 (1997)] showed improvement in visual performance using adaptive optics (AO). Since then, AO visual simulators have been developed to explore the spatial limits to human vision and as platforms to test non-invasively optical corrections for presbyopia, myopia, or corneal irregularities. These applications have allowed new psychophysics bypassing the optics of the eye, ranging from studying the impact of the interactions of monochromatic and chromatic aberrations on vision to neural adaptation. Other applications address new paradigms of lens designs and corrections of ocular errors. The current paper describes a series of AO visual simulators developed in laboratories around the world, key applications, and current trends and challenges. As the field moves into its second quarter century, new available technologies and a solid reception by the clinical community promise a vigorous and expanding use of AO simulation in years to come., National Eye Institute (P30EY 001319, R01EY014999, R01EY034151); Agencia Estatal de Investigación (PID2019-105684RB-I00, PID2020-115191RB-I00); Vetenskapsrådet (2019-05354); Engineering and Physical Sciences Research Council (G015473/1); Research to Prevent Blindness (N/A Unrestricted funds (UoR)); H2020 Marie SkłodowskaCurie Actions (#675137); Empire State Development’s Division of Science, Technology and Innovation (CEIS #2130C002).
DIGITAL.CSIC. Repositorio Institucional del CSIC
Publicación Artículo científico (JournalArticle)

Visual simulation of intraocular lenses: technologies and applications [Invited]

  • Marcos, Susana
  • Artal, Pablo
  • Lundström, Linda
  • Yoon, Geunyoung
18 pages, 7 figures, Cataract surgery requires selecting an intraocular lens (IOL), whose design affects visual outcomes. Traditional IOL evaluation relies on optical models and bench testing, but these methods fall short in simulating perceptual factors crucial to patient experience. Visual simulators, based on different principles including adaptive optics, temporal multiplexing or physical projection of the IOLs, now allow patients and clinicians to preview and compare different IOL designs preoperatively. By simulating real-world interactions of the eye's optics and the visual system with IOLs, these simulators enhance the patient decision-making process, enable personalized cataract surgery, and can aid in regulatory assessments of IOLs by incorporating pre-operative patient-reported visual outcomes. Visual simulators incorporate deformable mirrors, spatial light modulators and optotunable lenses as dynamic elements to simulate monofocal, multifocal and extended depth-of-focus IOLs, including newer designs aimed at improving contrast sensitivity, expanding depth of focus, and minimizing visual disturbances. With ongoing advancements, these simulators hold potential for transforming IOL design, regulatory processes, and patient care by providing realistic and patient-centered visual assessments, ultimately leading to more successful, individualized surgical outcomes., Agencia Estatal de Investigación (PID2020-115191RB-I00, PID2019-105684RB-I00); European Commission (H2020 ITN Network Marie Sklodowska-Curie #675137); National Eye Institute (P30EY001319, R01EY014999, R01EY034151, R01EY035009, P30EY007551); Empire State Development (CEIS #2130C00); Research to Prevent Blindness (Unrestricted Funds. Department of Ophthalmology); Vetenskapsrådet (2019-05354); Meta Reality Labs (Unrestricted gifts); RxSight (Unrestricted gift)., Peer reviewed