Pasar al contenido principal

DESARROLLO DE FILTROS PASO-BANDA BASADOS EN CAVIDADES DE MICROONDAS PARA LA DETECCION DE AXIONES

BES-2017-079787

•
Nombre agencia financiadora Agencia Estatal de Investigación
Acrónimo agencia financiadora AEI
Programa Programa Estatal de Promoción del Talento y su Empleabilidad en I+D+i
Subprograma Subprograma Estatal de Formación
Convocatoria Contratos Predoctorales
Año convocatoria 2017
Plan Estatal 2017-2020 Plan Estatal de Investigación Científica y Técnica y de Innovación
Centro beneficiario UNIVERSIDAD POLITÉCNICA DE CARTAGENA

Resultados relacionados

Resultados totales (Incluyendo duplicados): 11
Encontrada(s) 1 página(s)

Academica-e. Repositorio Institucional de la Universidad Pública de Navarra
Publicación Artículo científico (JournalArticle)

The Canfranc Axion Detection Experiment (CADEx): search for axions at 90 GHz with kinetic inductance detectors

  • Aja, Beatriz
  • Arguedas Cuendis, Sergio
  • Arregui Padilla, Iván
  • Artal, Eduardo
  • Barreiro, R. Belén
  • Casas, Francisco J.
  • Ory, Marina C. de
  • Díaz-Morcillo, Alejandro
  • Fuente, Luisa de la
  • Gallego, Juan Daniel
  • García-Barceló, José María
  • Gimeno, Benito
  • Gómez, Alicia
  • Granados, Daniel
  • Kavanagh, Bradley J.
  • Gómez Laso, Miguel Ángel
  • Lopetegui Beregaña, José María
  • Lozano-Guerrero, Antonio José
  • Magaz, María T.
  • Martín-Pintado, Jesús
  • Martínez-González, Enrique
  • Miralda-Escudé, Jordi
  • Monzó-Cabrera, Juan
  • Najarro de la Parra, Francisco
  • Navarro-Madrid, José R.
  • Núñez Chico, Ana B.
  • Pascual, Juan Pablo
  • Pelegrín, Jorge
  • Peña Garay, Carlos
  • Rodríguez, David
  • Socuéllamos, Juan M.
  • Teberio Berdún, Fernando
  • Teniente Vallinas, Jorge
  • Vielva, Patricio
  • Vila, Iván
  • Vilar, Rocío
  • Villa, Enrique
We propose a novel experiment, the Canfranc Axion Detection Experiment (CADEx), to probe dark matter axions with masses in the range 330–460 μeV, within the W-band (80–110 GHz), an unexplored parameter space in the well-motivated dark matter window of Quantum ChromoDynamics (QCD) axions. The experimental design consists of a microwave resonant cavity haloscope in a high static magnetic field coupled to a highly sensitive detecting system based on Kinetic Inductance Detectors via optimized quasi-optics (horns and mirrors). The experiment is in preparation and will be installed in the dilution refrigerator of the Canfranc Underground Laboratory. Sensitivity forecasts for axion detection with CADEx, together with the potential of the experiment to search for dark photons, are presented., SA and JM are supported by grants PID2019-108122GB-C32 and the Maria de Maeztu grant CEX-2019-000918-M of ICCUB. The work of UPCT and IFIC is supported by grant PID2019-108122GB-C33, funded by MCIN/AEI/10.13039/501100011033/ and by “ERDF A way of making Europe”. JMGB thanks the grant FPI BES-2017-079787, funded by MCIN/AEI/10.13039/501100011033 and by “ESF Investing in your future”. The work of Universidad de Cantabria is supported by the Ministry of Science and Innovation under Grant PID2019-110610RB-C22. CAB and IMDEA-Nanoscience work is supported by grants PID2019-105552RB-C41 and PID2019-105552RB-C44 and by Comunidad de Madrid under Grant P2018/NMT-4291. IMDEA-Nanoscience acknowledges financial support from “Severo Ochoa” Programme for Centers of Excellence in R&D (MINECO, Grant SEV-2016-0686). D.G. and A.G also acknowledge Grant DEFROST N62909-19-1-2053 from ONR Global. RBB, FJC, BJK, EMG, JMS and PV thank the Spanish Agencia Estatal de Investigación (AEI, MICIU) for the support to the Unidad de Excelencia María de Maeztu Instituto de Física de Cantabria, ref. MDM-2017-0765. RBB, FJC, EMG and PV thank the Spanish Agencia Estatal de Investigación (AEI, MCI) for the funds received through the research project, ref. PID2019-110610RB-C21. RBB, FJC, BJK, EMG, JMS and PV also thank the ‘Dark Collaboration at IFCA’ working group for useful discussions. The work done by ANTERAL S.L. is supported by project QON-Space financed by the Navarra Government Project No. 0011-1365-2021-000220. UPNA acknowledges financial support from the Spanish State Research Agency, Project No. PID2019-109984RB-C43/AEI/10.13039/501100011033 and Project No. PID2020-112545RB-C53/MCIN/AEI/ 10.13039/501100011033.
DIGITAL.CSIC. Repositorio Institucional del CSIC
Publicación Artículo científico (JournalArticle)

Design of new resonant haloscopes in the search for the dark matter axion: A review of the first steps in the RADES collaboration

  • Díaz-Morcillo, Alejandro
  • García Barceló, José María
  • Lozano-Guerrero, Antonio José
  • Navarro, Pablo
  • Gimeno, Benito
  • Arguedas Cuendis, Sergio
  • Álvarez Melcón, Alejandro
  • Cogollos, Cristian
  • Calatroni, Sergio
  • Döbrich, Babette
  • Gallego, Juan Daniel
  • Golm, Jessica
  • Irastorza, Igor G.
  • Malbrunot, Chloé
  • Miralda-Escudé, Jordi
  • Peña-Garay, Carlos
  • Redondo, Javier
  • Wuensch, Walter
This article belongs to the Special Issue Studying the Universe from Spain., With the increasing interest in dark matter axion detection through haloscopes, in which different international groups are currently involved, the RADES group was established in 2016 with the goal of developing very sensitive detection systems to be operated in dipole magnets. This review deals with the work developed by this collaboration during its first five years: from the first designs—based on the multi-cavity concept, aiming to increase the haloscope volume, and thereby improve sensitivity—to their evolution, data acquisition design, and finally, the first experimental run. Moreover, the envisaged work within RADES for both dipole and solenoid magnets in the short and medium term is also presented., This work has been funded by the Spanish Agencia Estatal de Investigación (AEI) and Fondo Europeo de Desarrollo Regional (FEDER) under projects FPA-2016-76978-C3-2-P (supported by the grant FPI BES-2017-079787) and PID2019-108122GB-C33, and was supported by the CERN Doctoral Studentship programme. The research leading to these results has received funding from the European Research Council under grant ERC-2018-StG-802836 (AxScale project). IGI acknowledges support from the European Research Council (ERC) under grant ERC-2017-AdG-788781 (IAXO+ project)., Peer reviewed
DIGITAL.CSIC. Repositorio Institucional del CSIC
Publicación Artículo científico (JournalArticle)

Wide-band full-wave electromagnetic modal analysis of the coupling between dark-matter axions and photons in microwave resonators

  • Navarro, Pablo
  • Gimeno, Benito
  • Álvarez Melcón, Alejandro
  • Arguedas Cuendis, Sergio
  • Cogollos, Cristian
  • Díaz-Morcillo, Alejandro
  • Gallego, Juan Daniel
  • García Barceló, José María
  • Golm, Jessica
  • Irastorza, Igor G.
  • Lozano-Guerrero, Antonio José
  • Peña-Garay, Carlos
The electromagnetic coupling axion–photon in a microwave cavity is revisited with the Boundary Integral-Resonant Mode Expansion (BI-RME) 3D technique. Such full-wave modal technique has been applied for the rigorous analysis of the excitation of a microwave cavity with an axion field. In this scenario, the electromagnetic field generated by the axion–photon coupling can be assumed to be driven by equivalent electrical charge and current densities. These densities have been inserted in the general BI-RME 3D equations, which express the RF electromagnetic field existing within a cavity as an integral involving the Dyadic Green’s functions of the cavity (under Coulomb gauge) as well as such densities. This method is able to take into account any arbitrary spatial and temporal variation of both magnitude and phase of the axion field. Next, we have obtained a simple network driven by the axion current source, which represents the coupling between the axion field and the resonant modes of the cavity. With this approach, it is possible to calculate the extracted and dissipated RF power as a function of frequency along a broad band and without Cauchy–Lorentz approximations, obtaining the spectrum of the electromagnetic field generated in the cavity, and dealing with modes relatively close to the axion resonant mode. Moreover, with this technique we have a complete knowledge of the signal extracted from the cavity, not only in magnitude but also in phase. This can be an interesting issue for future analysis where the axion phase is an important parameter., This work is part of the project PID2019-108122GB-C33 and the grant FPI BES-2017-079787 (under project FPA-2016-76978-C3-2-P), both funded by MCIN/AEI/10.13039/501100011033 and by ERDF A way of making Europe. JG acknowledges support through the European Research Council under grant ERC-2018-StG-802836 (AxScale project)., Peer reviewed
DIGITAL.CSIC. Repositorio Institucional del CSIC
Publicación Artículo científico (JournalArticle)

The Canfranc Axion Detection Experiment (CADEx): search for axions at 90 GHz with Kinetic Inductance Detectors

  • Aja, Beatriz
  • Arguedas, Sergio
  • Arregui, Ivan
  • Artal, Eduardo
  • Barreiro, R. Belén
  • Casas-Reinares, F. J.
  • Ory, Marina C. de
  • Díaz-Morcillo, Alejandro
  • Fuente, Luisa de la
  • Gallego, Juan Daniel
  • García Barceló, José María
  • Gimeno, Benito
  • Gómez, Alicia
  • Granados, Daniel
  • Kavanagh, Bradley J.
  • Laso, Miguel A.G.
  • Lopetegi, Txema
  • Lozano-Guerrero, Antonio José
  • Magaz, María Teresa
  • Martín-Pintado, Jesús
  • Martínez-González, Enrique
  • Miralda-Escudé, Jordi
  • Monzó-Cabrera, Juan
  • Najarro, Francisco
  • Navarro-Madrid, José R.
  • Núñez Chico, Ana Belén
  • Pascual, Juan Pablo
  • Pelegrin, Jorge
  • Peña-Garay, Carlos
  • Rodríguez González, David
  • Socuéllamos, Juan M.
  • Teberio, Fernando
  • Teniente, Jorge
  • Vielva, Patricio
  • Vila, Iván
  • Vilar Cortabitarte, R.
  • Villa, Enrique
We propose a novel experiment, the Canfranc Axion Detection Experiment (CADEx), to probe dark matter axions with masses in the range 330–460 μeV, within the W-band (80–110 GHz), an unexplored parameter space in the well-motivated dark matter window of Quantum ChromoDynamics (QCD) axions. The experimental design consists of a microwave resonant cavity haloscope in a high static magnetic field coupled to a highly sensitive detecting system based on Kinetic Inductance Detectors via optimized quasi-optics (horns and mirrors). The experiment is in preparation and will be installed in the dilution refrigerator of the Canfranc Underground Laboratory. Sensitivity forecasts for axion detection with CADEx, together with the potential of the experiment to search for dark photons, are presented., SA and JM are supported by grants PID2019-108122GB-C32 and the Maria de Maeztu grant CEX-2019-000918-M of ICCUB. The work of UPCTand IFIC is supported by grant PID2019-108122GB-C33, funded by MCIN/AEI/10.13039/501100011033/ and by “ERDF A way of making Europe”. JMGB thanks the grant FPI BES-2017-079787, funded by MCIN/AEI/10.13039/501100011033 and by “ESF Investing in your future”. The work of Universidad de Cantabria is supported by the Ministry of Science and Innovation under Grant PID2019-110610RB-C22. CAB and IMDEA-Nanoscience work is supported by grants PID2019-105552RB-C41 and PID2019-105552RB-C44 and by Comunidad de Madrid under Grant P2018/NMT-4291. IMDEA-Nanoscience acknowledges financial support from “Severo Ochoa” Programme for Centers of Excellence in R&D (MINECO, Grant SEV-2016-0686). D.G. and A.G also acknowledge Grant DEFROST N62909-19-1-2053 from ONR Global. RBB, FJC, BJK, EMG, JMS and PV thank the Spanish Agencia Estatal de Investigación (AEI, MICIU) for the support to the Unidad de Excelencia María de Maeztu Instituto de Física de Cantabria, ref. MDM-2017-0765. RBB, FJC, EMG and PV thank the Spanish Agencia Estatal de Investigación (AEI, MCI) for the funds received through the research project, ref. PID2019-110610RB-C21. RBB, FJC, BJK, EMG, JMS and PV also thank the ‘Dark Collaboration at IFCA’ working group for useful discussions. The work done by ANTERAL S.L. is supported by project QON-Space financed by the Navarra Government Project No. 0011-1365-2021-000220. UPNA acknowledges financial support from the Spanish State Research Agency, Project No. PID2019-109984RB-C43/AEI/10.13039/501100011033 and Project No. PID2020-112545RB-C53/MCIN/AEI/ 10.13039/501100011033., Peer reviewed
DIGITAL.CSIC. Repositorio Institucional del CSIC
Publicación Artículo científico (JournalArticle)

On the development of new tuning and Inter-coupling techniques using ferroelectric materials in the detection of dark matter axions

  • García Barceló, José María
  • Álvarez Melcón, Alejandro
  • Arguedas Cuendis, Sergio
  • Díaz-Morcillo, Alejandro
  • Gimeno, Benito
  • Kanareykin, A.
  • Lozano-Guerrero, Antonio José
  • Navarro, Pablo
  • Wuensch, Walter
Tuning is an essential requirement for the search of dark matter axions employing haloscopes since its mass is not known yet to the scientific community. At the present day, most haloscope tuning systems are based on mechanical devices which can lead to failures due to the complexity of the environment in which they are used. However, the electronic tuning making use of ferroelectric materials can provide a path that is less vulnerable to mechanical failures and thus complements and expands current tuning systems. In this work, we present and design a novel technique for using the ferroelectric Potassium Tantalate ( KTaO3 or KTO) material as a tuning element in haloscopes based on coupled microwave cavities. In this line, the structures used in the Relic Axion Detector Exploratory Setup (RADES) group are based on several cavities that are connected by metallic irises, which act as interresonator coupling elements. In this article, we also show how to use these KTaO3 films as interresonator couplings between cavities, instead of inductive or capacitive metallic windows used in the past. These two techniques represent a crucial upgrade over the current systems employed in the dark matter axions community, achieving a tuning range of 2.23% which represents a major improvement as compared to previous works ( <0.1% ) for the same class of tuning systems. The theoretical and simulated results shown in this work demonstrate the interest of the novel techniques proposed for the incorporation of this kind of ferroelectric media in multicavity resonant haloscopes in the search for dark matter axions., This work was supported in part by the ‘‘MCIN/AEI/10.13039/501100011033/’’ and ‘‘European Regional Development Fund (ERDF) A way of making Europe’’ under Grant PID2019-108122GB-C33, in part by the ‘‘MCIN/AEI/10.13039/501100011033/’’ and ‘‘European Social Fund (ESF) Investing in your future’’ under Grant FPI BES-2017-079787, and in part by the European Research Council (ERC) under Grant ERC-2018-StG-802836 (AxScale)., Peer reviewed
DIGITAL.CSIC. Repositorio Institucional del CSIC
Publicación Artículo científico (JournalArticle)

Enhancing resonant circular-section haloscopes for dark matter axion detection: approaches and limitations in volume expansion

  • García-Barceló, José María
  • Díaz-Morcillo, Alejandro
  • Gimeno, Benito
Haloscopes, microwave resonant cavities utilized in detecting dark matter axions within powerful static magnetic fields, are pivotal in modern astrophysical research. This paper delves into the realm of cylindrical geometries, investigating techniques to augment volume and enhance compatibility with dipole or solenoid magnets. The study explores volume constraints in two categories of haloscope designs: those reliant on single cavities and those employing multicavities. In both categories, strategies to increase the expanse of elongated structures are elucidated. For multicavities, the optimization of space within magnets is explored through 1D configurations. Three subcavity stacking approaches are investigated, while the foray into 2D and 3D geometries lays the groundwork for future topological developments. The results underscore the efficacy of these methods, revealing substantial room for progress in cylindrical haloscope design. Notably, an elongated single cavity design attains a three-order magnitude increase in volume compared to a WC-109 standard waveguide-based single cavity. Diverse prototypes featuring single cavities, 1D, 2D, and 3D multicavities highlight the feasibility of leveraging these geometries to magnify the volume of tangible haloscope implementations., Peer reviewed
DIGITAL.CSIC. Repositorio Institucional del CSIC
Publicación Artículo científico (JournalArticle)

Methods and restrictions to increase the volume of resonant rectangular-section haloscopes for detecting dark matter axions

  • García-Barceló, José María
  • Álvarez Melcón, Alejandro
  • Díaz-Morcillo, Alejandro
  • Gimeno, Benito
  • Lozano-Guerrero, Antonio José
  • Monzó-Cabrera, Juan
  • Navarro-Madrid, José R.
  • Navarro, P.
Haloscopes are resonant cavities that serve as detectors of dark matter axions when they are immersed in a strong static magnetic field. In order to increase the volume and improve space compatibility with dipole or solenoid magnets for axion searches, various haloscope design techniques for rectangular geometries are discussed in this study. The volume limits of two types of haloscopes are explored: those based on single cavities and those based on multicavities. In both cases, possibilities for increasing the volume of long and/or tall structures are presented. For multicavities, 1D geometries are explored to optimise the space in the magnets. Also, 2D and 3D geometries are introduced as a first step in laying the foundations for the development of these kinds of topologies. The results prove the usefulness of the developed methods, evidencing the ample room for improvement in rectangular haloscope designs nowadays. A factor of three orders of magnitude improvement in volume compared with a single cavity based on the WR-90 standard waveguide is obtained with the design of a long and tall single cavity. Similar procedures have been applied for long and tall multicavities. Experimental measurements are shown for prototypes based on tall multicavities and 2D structures, demonstrating the feasibility of using these types of geometries to increase the volume of real haloscopes., Peer reviewed
DIGITAL.CSIC. Repositorio Institucional del CSIC
Publicación Artículo científico (JournalArticle)

A Proposal for a Low-Frequency Axion Search in the 1–2 μ eV Range and Below with the BabyIAXO Magnet

  • Ahyoune, Saiyd
  • Álvarez Melcón, Alejandro
  • Arguedas Cuendis, Sergio
  • Calatroni, Sergio
  • Cogollos, Cristian
  • Devlin, Jack
  • Díaz-Morcillo, Alejandro
  • Díez-Ibáñez, David
  • Döbrich, Babette
  • Galindo, Javier
  • Gallego, Juan Daniel
  • García-Barceló, Jose María
  • Gimeno, Benito
  • Golm, Jessica
  • Gu, Yikun
  • Herwig, Louis
  • Garcia Irastorza, Igor
  • Lozano-Guerrero, Antonio Jose
  • Malbrunot, Chloé
  • Miralda-Escudé, Jordi
  • Monzó-Cabrera, Juan
  • Navarro, Pablo
  • Navarro-Madrid, Jose Ramón
  • Redondo, Javier
  • Reina-Valero, José
  • Schmieden, Kristof
  • Schneemann, Tim
  • Siodlaczek, Marc
  • Ulmer, Stefan
  • Wuensch, Walter
In the near future BabyIAXO will be the most powerful axion helioscope, relying on a custom-made magnet of two bores of 70 cm diameter and 10 m long, with a total available magnetic volume of more than 7 m. In this document, it proposes and describe the implementation of low-frequency axion haloscope setups suitable for operation inside the BabyIAXO magnet. The RADES proposal has a potential sensitivity to the axion-photon coupling (Formula presented.) down to values corresponding to the KSVZ model, in the (currently unexplored) mass range between 1 and 2 (Formula presented.) eV, after a total effective exposure of 440 days. This mass range is covered by the use of four differently dimensioned 5-meter-long cavities, equipped with a tuning mechanism based on inner turning plates. A setup like the one proposed will also allow an exploration of the same mass range for hidden photons coupled to photons. An additional complementary apparatus is proposed using LC circuits and exploring the low energy range ((Formula presented.) eV). The setup includes a cryostat and cooling system to cool down the BabyIAXO bore down to about 5 K, as well as an appropriate low-noise signal amplification and detection chain.
Zaguán. Repositorio Digital de la Universidad de Zaragoza
Publicación Reseña (Review)

Design of new resonant haloscopes in the search for the Dark Matter Axion: a review of the first steps in the RADES collaboration

  • Diaz-Morcillo, A.
  • García Barcelo, J. M.
  • Lozano Guerrero, A. J.
  • Navarro, P.
  • Gimeno, B.
  • Arguedas Cuendis, S.
  • Álvarez Melcon, A.
  • Cogollos, C.
  • Calatroni, S.
  • Doebrich, B.
  • Gallego-Puyol, J. D.
  • Golm, J.
  • García Irastorza, I.
  • Malbrunot, C.
  • Miralda-Escude, J.
  • Pena Garay, C.
  • Redondo, J.
  • Wuensch, W.
With the increasing interest in dark matter axion detection through haloscopes, in which different international groups are currently involved, the RADES group was established in 2016 with the goal of developing very sensitive detection systems to be operated in dipole magnets. This review deals with the work developed by this collaboration during its first five years: from the first designs—based on the multi-cavity concept, aiming to increase the haloscope volume, and thereby improve sensitivity—to their evolution, data acquisition design, and finally, the first experimental run. Moreover, the envisaged work within RADES for both dipole and solenoid magnets in the short and medium term is also presented.
Zaguán. Repositorio Digital de la Universidad de Zaragoza
Publicación Artículo científico (JournalArticle)

Thin film (high temperature) superconducting radiofrequency cavities for the search of axion dark matter

  • Golm, J.
  • Arguedas Cuendis, S.
  • Calatroni, S.
  • Cogollos, C.
  • Dobrich, B.
  • Gallego, J.D.
  • Garcia Barcelo, J.M.
  • Granados, X.
  • Gutierrez, J.
  • García Irastorza, I.
  • Koettig, T.
  • Lamas, N.
  • Liberadzka-Porret, J.
  • Malbrunot, C.
  • Millar, W.L.
  • Navarro, P.
  • Carlos, C.P.A.
  • Puig, T.
  • Rosaz, G.J.
  • Siodlaczek, M.
  • Telles, G.
  • Wuensch, W.
The axion is a hypothetical particle which is a candidate for cold dark matter. Haloscope experiments directly search for these particles in strong magnetic fields with RF cavities as detectors. The Relic Axion Detector Exploratory Setup (RADES) at CERN in particular is searching for axion dark matter in a mass range above 30 μ eV. The figure of merit of our detector depends linearly on the quality factor of the cavity and therefore we are researching the possibility of coating our cavities with different superconducting materials to increase the quality factor. Since the experiment operates in strong magnetic fields of 11 T and more, superconductors with high critical magnetic fields are necessary. Suitable materials for this application are for example REBa 2 Cu 3 O 7−x , Nb 3 Sn or NbN. We designed a microwave cavity which resonates at around 9 GHz, with a geometry optimized to facilitate superconducting coating and designed to fit in the bore of available high-field accelerator magnets at CERN. Several prototypes of this cavity were coated with different superconducting materials, employing different coating techniques. These prototypes were characterized in strong magnetic fields at 4.2 K.
Zaguán. Repositorio Digital de la Universidad de Zaragoza
Publicación Artículo científico (JournalArticle)

Wide-band full-wave electromagnetic modal analysis of the coupling between dark-matter axions and photons in microwave resonators

  • Navarro, P.
  • Gimeno, Benito
  • Álvarez Melcón, A.
  • Arguedas Cuendis, S.
  • Cogollos, C.
  • Díaz-Morcillo, A.
  • Gallego, J.D.
  • García Barceló, J.M.
  • Golm, J.
  • Irastorza, I.G.
  • Lozano Guerrero, A.J.
  • Peña Garay, C.
The electromagnetic coupling axion–photon in a microwave cavity is revisited with the Boundary Integral-Resonant Mode Expansion (BI-RME) 3D technique. Such full-wave modal technique has been applied for the rigorous analysis of the excitation of a microwave cavity with an axion field. In this scenario, the electromagnetic field generated by the axion–photon coupling can be assumed to be driven by equivalent electrical charge and current densities. These densities have been inserted in the general BI-RME 3D equations, which express the RF electromagnetic field existing within a cavity as an integral involving the Dyadic Green''s functions of the cavity (under Coulomb gauge) as well as such densities. This method is able to take into account any arbitrary spatial and temporal variation of both magnitude and phase of the axion field. Next, we have obtained a simple network driven by the axion current source, which represents the coupling between the axion field and the resonant modes of the cavity. With this approach, it is possible to calculate the extracted and dissipated RF power as a function of frequency along a broad band and without Cauchy–Lorentz approximations, obtaining the spectrum of the electromagnetic field generated in the cavity, and dealing with modes relatively close to the axion resonant mode. Moreover, with this technique we have a complete knowledge of the signal extracted from the cavity, not only in magnitude but also in phase. This can be an interesting issue for future analysis where the axion phase is an important parameter.