Pasar al contenido principal

CEMENTOS Y HORMIGONES PREPARADOS CON RESIDUOS NORM (NATURALLY OCCURRING RADIOACTIVE MATERIAL). COMPORTAMIENTO, PROPIEDADES Y CARACTERIZACION RADIOLOGICA

BES-2017-081306

•
Nombre agencia financiadora Agencia Estatal de Investigación
Acrónimo agencia financiadora AEI
Programa Programa Estatal de Promoción del Talento y su Empleabilidad en I+D+i
Subprograma Subprograma Estatal de Formación
Convocatoria Contratos Predoctorales
Año convocatoria 2017
Plan Estatal 2017-2020 Plan Estatal de Investigación Científica y Técnica y de Innovación
Centro beneficiario AGENCIA ESTATAL CONSEJO SUPERIOR DE INVESTIGACIONES CIENTIFICAS (CSIC)

Resultados relacionados

Resultados totales (Incluyendo duplicados): 3
Encontrada(s) 1 página(s)

DIGITAL.CSIC. Repositorio Institucional del CSIC
Publicación Artículo científico (JournalArticle)

Gamma spectrometry and LabSOCS-calculated efficiency in the radiological characterisation of quadrangular and cubic specimens of hardened portland cement paste

  • Suárez-Navarro, José Antonio
  • Moreno de los Reyes, A.M.
  • Gascó, C.
  • Alonso López, M. del Mar
  • Puertas, Francisca
Pursuant to European Directive 2013/59, materials additioned with NORM waste must be characterised radiologically to determine their acceptability for use in construction. The radionuclides studied to judge that acceptability, 232Th, 226Ra and 40K, are normally measured with gamma spectrometry. Gamma detectors are calibrated by using standards as similar as possible in dimensions and chemical composition as the matrix in the samples to be measured. In light of the broad spectrum of chemical and physical characteristics of NORM samples, experimental calibration is often beyond the means of gamma spectrometry laboratories. As a result, Monte Carlo-based methods are deployed to simulate the experimental setup consisting in detector and sample, both geometrically and chemically. Canberra Industries’ LabSOCS (Laboratory Sourceless Calibration Software) is one of the tools available for such calculations. This study verified the accuracy and precision of the counting efficiency delivered by LabSOCS, both with the standard powder geometry and a new geometry consisting in a 5 cm cubic specimen of Portland cement paste. The findings showed that in both geometries the accuracy and precision of LabSOCS-calculated efficiency (by specimen height and activity), across an energy range from 45.64 keV (210Pb) to 1460.82 keV (40K) met the acceptability criteria routinely applied in environmental radioactivity laboratories. The geometry proposed yielded activity values for the end construction material closer to the true indices than the conventional method consisting in summing the partial activities of the unreacted components., This study was funded by the Spanish Ministry of Science, Innovation and Universities' Research Agency and the European Regional Development Fund (AEI/ERDF/EU) under project BIA2016-77252-P. Author Ana María Moreno de los Reyes participated in the study under Spanish Research Agency pre-doctoral grant BES-2017-081306., Peer reviewed
DIGITAL.CSIC. Repositorio Institucional del CSIC
Publicación Artículo científico (JournalArticle)

Microstructural, mechanical and radiological characterization of mortars made with granite sand

  • Puertas, Francisca
  • Suárez-Navarro, José Antonio
  • Gil-Maroto, A.
  • Moreno de los Reyes, A.M.
  • Gascó, Catalina
  • Pachón Montaño, Alicia
  • Alonso López, M. del Mar
The study reported the effect of granite sand on strength and microstructural developments in mortars prepare from OPC with a high coal fly ash (FA) content or from hybrid alkaline cements. The radiological behaviour of the resulting mortars was compared to materials prepared with siliceous sand (with particles sizes of <2 mm) and the relationship between such radiological findings and mortar microstructure and strength was explored. A new method for determining natural radionuclides and their activity concentration Index (ACI) on cement mortars (specifically to solid 5-cm cubic specimens) was applied and validated. The microstructural changes associated in mortars have no effect on mortar radiological content measurements. The mortars with granite sand exhibited very high ACI > 0.96, which would ultimately limit their use. A conclusion of interest is that where information is at hand on the starting materials (OPC, FA, sand, admixtures), their pro-portions in the mortar and the mixing liquid content (water or alkaline activators) their radiological content is accurately predicted. The inference is that a mortar’s radiological content and ACI can be known prior to mixing, providing a criterion for determining its viability. That in turn lowers environmental risks and the health hazards for people in contact with such materials., This study was funded by the Spanish Ministry of Science and Innovation as well as by the National Research Agency in conjunction with the European Regional Development Fund (AEI/ERDF/EU) under research project BIA2016-77252-P. Ana María Moreno de los Reyes participated in the study under National Research Agency pre-doctoral grant BES-2017-081306. M.M. Alonso also wishes to thank CSIC for funding the project PIE 2018 60I 054., Peer reviewed
DIGITAL.CSIC. Repositorio Institucional del CSIC
Publicación Artículo científico (JournalArticle)

Hybrid Cements: Mechanical Properties, Microstructure and Radiological Behavior

  • Moreno de los Reyes, A.M.
  • Suárez-Navarro, José Antonio
  • Alonso López, M. del Mar
  • Gascó, Catalina
  • Sobrados, Isabel
  • Puertas, Francisca
The use of more eco-efficient cements in concretes is one of the keys to ensuring construction industry sustainability. Such eco-efficient binders often contain large but variable proportions of industrial waste or by-products in their composition, many of which may be naturally occurring radioactive materials (NORMs). This study explored the application of a new gamma spectrometric method for measuring radionuclide activity in hybrid alkali-activated cements from solid 5 cm cubic specimens rather than powder samples. The research involved assessing the effect of significant variables such as the nature of the alkaline activator, reaction time and curing conditions to relate the microstructures identified to the radiological behavior observed. The findings showed that varying the inputs generated pastes with similar reaction products (C-S-H, C-A-S-H and (N,C)-A-S-H) but different microstructures. The new gamma spectrometric method for measuring radioactivity in solid 5 cm cubic specimens in alkaline pastes was found to be valid. The variables involved in hybrid cement activation were shown to have no impact on specimen radioactive content. The powder samples, however, emanated Rn (a descendent of Ra), possibly due to the deformation taking place in fly ash structure during alkaline activation. Further research would be required to explain that finding., Funding: This study was funded by the Spanish Ministry of Science and Innovation and the country’s National Research Agency, as well as the European Regional Development Fund (AEI/FEDER/EU) under research projects BIA2016-77252-P and PID2020-116002RB-I00, Ana María Moreno de los Reyes participated in the study under pre-doctoral grant BES-2017-081306 awarded by the National Research Agency., Peer reviewed