Pasar al contenido principal

CONTROL Y ESTRATEGIAS DE OPERACION PARA MITIGACION DE EMISION DE GASES DE EFECTO INVERNADERO: APLICACION A PLANTAS DE TRATAMIENTO DE AGUAS RESIDUALES

DPI2016-77271-R

•
Nombre agencia financiadora Agencia Estatal de Investigación
Acrónimo agencia financiadora AEI
Programa Programa Estatal de I+D+i Orientado a los Retos de la Sociedad
Convocatoria Proyectos I+D+i Retos de Investigación
Año convocatoria 2016
Plan Estatal 2013-2016 Plan Estatal de Investigación Científica y Técnica y de Innovación
Centro beneficiario UNIVERSIDAD AUTONOMA DE BARCELONA

Resultados relacionados

Resultados totales (Incluyendo duplicados): 25
Encontrada(s) 1 página(s)

RiuNet. Repositorio Institucional de la Universitat Politécnica de Valéncia
Publicación Artículo científico (JournalArticle)

Control y Operación de Estaciones Depuradoras de Aguas Residuales: Modelado y Simulación, Control and operation of wastewater treatment plants

  • Vilanova, Ramón
  • Santín, Ignacio
  • Pedret, Carles
[ES] Este trabajo constituye la primera parte de una revisión de la problemática del control y operación de estaciones depuradoras de aguas residuales (EDAR) para el tratamiento de agua residual urbana. En esta primera parte nos centramos en el modelado y simulación mientras que la segunda parte se dedica en exclusiva al control y operación. Esta depuración se realiza, mayoritariamente, mediante procesos biológicos, concretamente, mediante el denominado proceso de fangos activados. El hecho de tratar con un proceso biológico conlleva una elevada complejidad tanto desde el punto de vista de modelado como, por supuesto, de control y operación. Para poder ubicar convenientemente el problema, se presenta una caracterización de las aguas residuales urbanas y las necesidades de depuración asociadas. El control y operación descansan en gran medida en la disponibilidad de modelos apropiados y, ya hoy en día, de una elevada fiabilidad. Se presentan los modelos de la familia ASM; poniendo especial énfasis en el ASM1 que se describe en más detalle; así como las características de otras unidades de proceso como el decantador y su interconexión. En estos modelos destacan los entornos BSM de benchmarking, que han sido esenciales para todo el posterior desarrollo en la actividad de control y operación., [EN] This tutorial is the first part of a review of the problems arising with the control and operation of wastewater treatment plants (WWTP) for urban wastewater. This first part will concentrate in the modelling and simulation steps whereas the second part will cover the control and operation issues. This treatment is carried out, mainly, by biological processes. Specifically, by the so-called activated sludge process. Dealing with a biological process entails a high complexity both from the viewpoint of modelling and, of course, from what matters to control and operation. In order to properly locate the problem, a characterisation of the urban wastewater and the associated treatment needs are presented. Control and operation rely heavily on the availability of appropriate models and, today, of proved reliability. The models of the ASM family are presented; placing special emphasis on the ASM1 that is described in more detail; as well as the characteristics of other process units like the settler and its interconnection. These models highlight the BSM benchmarking environments, which have been essential for all subsequent development in the control and operation activity., Este trabajo es fruto de la investigacion de los autores en ´ diversos proyectos financiados por el Ministerio de Econom´ıa y Competitividad que han desembocado en el proyecto que se esta llevando a cabo actualmente, DPI2016-77271-R
RiuNet. Repositorio Institucional de la Universitat Politécnica de Valéncia
Publicación Artículo científico (JournalArticle)

Control deslizante fraccionario de la trayectoria y orientación de un quadrotor con cargas suspendidas desconocidas, Sliding Fractional Order Trajectory and Attitude Control of a Quadrotor Transporting Cable-Suspended Unknown Payloads

  • Ullah, Nasim
  • Ali, Muhammah Asghar
  • Ibeas, Asier
  • Herrera, Jorge
[EN] This article designs a control system for the trajectory tracking problem of a quadrotor vehicle with an unknown suspended load. The presence of this unknown load considerably increases the complexity of the problem while its oscillation acts as an unknown perturbation that affects the dynamics of the vehicle. In this way, the overall trajectory of the quadrotor can be greatly affected despite the existence of a nominal controller for it. This article proposes the design of a fractional order sliding mode control for the solution of this problem. Along with the design of the control law, the stability proof of the closed-loop system is carried out by using the Lyapunov method for fractional systems. The performance obtained by the proposed controller is compared with the classic sliding mode control, observing that the proposed controller significantly improves the results., [ES] Este artículo diseña un sistema de control para el problema de seguimiento de trayectorias de un vehículo quadrotor con una carga suspendida desconocida. La presencia de esta carga desconocida incrementa considerablemente la complejidad del problema y su oscilación actúa como una perturbación incierta que afecta a la dinámica propia del vehículo. De esta forma, la trayectoria global del quadrotor puede verse enormemente afectada a pesar de la existencia de un controlador nominal para él. Este artículo propone el diseño de un control deslizante de orden fraccionario para la solución de este problema. Junto con el diseño de la ley de control, se prueba la estabilidad del sistema en lazo cerrado a través del método de Lyapunov para sistemas fraccionarios. El desempeño obtenido por el controlador propuesto se compara con el control en modo deslizante clásico observando que el controlador propuesto mejora significativamente los resultados obtenidos., El trabajo de A. Ibeas está parcialmente financiado por el Ministerio de Economía y Competitividad de España a través del proyecto DPI2016-77271-R y por la Universidad del País Vasco/Euskal Herriko Unibertsitatea a través del proyecto PPG17/33.
RiuNet. Repositorio Institucional de la Universitat Politécnica de Valéncia
Publicación Artículo científico (JournalArticle)

Control en Estaciones Depuradoras de Aguas Residuales: Estado actual y perspectivas, Control and operation of wastewater treatment plants: challenges and state of the art

  • Vilanova, Ramón
  • Santín, Ignacio
  • Pedret, Carles
[ES] Este trabajo constituye la segunda parte de una revisión de la problemática del control de estaciones depuradoras de aguas residuales (EDAR) para el tratamiento de agua residual urbana. Después de haber presentado en la primera parte las perspectivas correspondientes al modelado y simulación, en esta segunda parte nos centramos en el control de las mismas. Esta depuración se realiza, mayoritariamente, mediante procesos biológicos, concretamente, mediante el denominado proceso de fangos activados. El hecho de tratar con un proceso biológico conlleva una elevada complejidad tanto desde el punto de vista de modelado como, por supuesto, de control. Se revisa el control de EDAR desde su perspectiva histórica, como de los lazos de control más usuales, problemáticas que presentan y algunas de las soluciones propuestas. Se realiza también una revisión de la aplicación de las diferentes técnicas de control catalogándolas de acuerdo a su filosofía. Para terminar se ofrece una visión de las tendencia actuales y perspectivas de desarrollos futuros., [EN] This tutorial is the second part of a review of the problems arising with the control and operation of wastewater treatment plants (WWTP) for urban wastewater. Having presented in the first part the modelling and simulation steps, in this second part we cover the control and operation issues. This treatment is carried out, mainly, by biological processes, specifically, by the so-called activated sludge process. Dealing with a biological process entails a high complexity both from the viewpoint of modelling and, of course, from what matters to control and operation. The control of WWTP is reviewed from an historical perspective, as well as the most common control loops, the problems that present and some of the proposed solutions. A review of the applications of different control techniques is also cataloged according to the philosophy of the control approach. Finally, it offers an overview of the current trends and future development prospects., Este trabajo es fruto de la investigación de los autores en diversos proyectos financiados por el Ministerio de Economía y Competitividad que han desembocado en el proyecto que se está llevando a cabo actualmente, DPI2016-77271-R.
RiuNet. Repositorio Institucional de la Universitat Politécnica de Valéncia
Publicación Artículo científico (JournalArticle)

Sintonía de controladores PID: un enfoque analítico basado en el moldeo de la función de sensibilidad, PID Tuning: Analytical approach based on the weighted Sensitivity problem

  • Vilanova, R.
  • Alcántara, S.
  • Pedret, C.
[EN] The PID controller is the most common option in the realm of control applications and is dominant in the process control industry. Among the related analytical methods, Internal Model Control (IMC) has gained remarkable industrial acceptance due to its robust nature and good set-point responses. However, the traditional application of IMC results in poor load disturbance rejection for lag-dominant and integrating plants. This work presents an IMC-like design method which avoids this common pitfall and is devised to work well for plants of modest complexity, for which analytical PID tuning is plausible. For simplicity, the design only focuses on the closed-loop sensitivity function. The approach provides model-based tuning of single-loop PID controllers in terms of the robustness/performance and servo/regulator trade-offs. Although the robustness/performance compromise is commonly considered, it is not so common to also take into account, for example, the conflict between input and output disturbances, referred also as the servo/regulator trade-off. As interested in providing a unified tuning approach, it is shown how the proposed methodology allows to deal with different process dynamics in a unified way., [ES] El controlador PID es la opción más común en el ámbito de las aplicaciones de control, siendo la opción predominante en el control de procesos industriales. Entre los métodos analíticos más usuales utilizados para su diseño, el Control por Modelo Interno (IMC) ha ganado una notable aceptación industrial debido a su naturaleza robusta y buenas respuestas ante cambios de consigna. Sin embargo, la aplicación tradicional del IMC da como resultado un bajo rendimiento para el rechazo de perturbaciones en carga para plantas integradoras y/o con largas constantes de tiempo. Este trabajo presenta un método de diseño, basado en IMC, que evita esta deficiencia y está diseñado para funcionar bien en plantas de complejidad moderada para las cuales, por otro lado, el ajuste analítico de un controlador PID es plausible. Por simplicidad, el diseño solo se centra en la función de sensibilidad en lazo cerrado. El enfoque proporciona un ajuste basado en modelo en términos de los compromisos robustez/rendimiento y de servo/regulación. Aunque comúnmente se considera el compromiso robustez/rendimiento, no es tan común tener en cuenta también, por ejemplo, el conflicto entre las perturbaciones de entrada y salida, también conocido como el compromiso servo/regulación. Con el objetivo de proporcionar un enfoque de ajuste unificado, se muestra como la metodología propuesta permite tratar diferentes dinámicas de proceso de manera unificada., Los autores desean agradecer al Ministerio de Economía y Competitividad bajo las subvenciones DPI-2016-77271-R y PID2019-105434RB-C33 por la ayuda que han supuesto en la elaboración de los trabajos que han conducido a los desarrollos aquí presentados.
Recercat. Dipósit de la Recerca de Catalunya
Publicación Contribución de congreso (ConferenceOutput)

Learning of accessibility in the development of multidisciplinary academic project

  • Montoya Chaves, Luis Hector
  • Ponsa Asensio, Pere
  • Vilanova Arbós, Ramón
  • De Olaizola Arizmendi, Iñaki
This work focuses on the learning and use of a process model of accessibility and usability for the acquisition of knowledge and skills in universal design, user-centered design and development of interactive systems. The results show an efficient use of the model in the integration of contents of Human Computer Interaction to the beginning and end of the Degrees of Industrial Engineering and Technology of Information and Communication of our School., Peer Reviewed, Postprint (published version)
Recercat. Dipósit de la Recerca de Catalunya
Publicación Contribución de congreso (ConferenceOutput)

Satisfaction and cognitive styles in students of the virtual collaborative project: "Our Earth: deforestation"

  • Montoya Chaves, Luis Hector
  • De Olaizola Arizmendi, Iñaki
  • Ponsa Asensio, Pere
  • Vilanova Arbós, Ramón
The objective of the research presented in this paper is to introduce concepts and methodology for the measure of satisfaction and cognitive styles. The base population is taken from a sample of 16 first grade high school students in different cities of Mexico, Portugal and Costa Rica, enrolled in the virtual collaborative project “Our Earth: Deforestation” of the Network of the Latin American Institute of Educational Communication (ILCE). To that end, the 26-Item Cognitive Style and Satisfaction Questionnaire (CSEC) was developed. In this work, cognitive learning styles and an initial assessment of collaborative usability are identified. The first results show a predominance of deep cognitive style and a high degree of satisfaction with the project. It is noticed that satisfaction and cognitive styles coexist in an interdependent way, since the complexity of the activities is identified with the deep or superficial style., Peer Reviewed, Postprint (published version)
Recercat. Dipósit de la Recerca de Catalunya
Publicación Contribución de congreso (ConferenceOutput)

Análisis de la evolución del Itinerario de Diseño Centrado en el Usuario y Diseño Inclusivo de la EPSEVG de la UPC

  • Guasch Murillo, Daniel
  • Ponsa Asensio, Pere
En el año 2009 se iniciaron los estudios de grado de “Diseño Industrial y Desarrollo del Producto” en la “Escola Politècnica Superior d’Enginyeria de Vilanova i la Geltrú” de la Universitat Politècnica de Catalunya. Una de las especificidades de este grado fue la incorporación de un itinerario de Diseño Centrado en el Usuario y Diseño Inclusivo, focalizado en el área de conocimiento de la interacción persona-computador. Nueve años después, se presenta un análisis de la evolución de este itinerario basado en datos estadísticos agregados reales. Se han analizado datos de procedencia y nota de acceso de los estudiantes, número de matriculados y titulados, resultados de evaluación los estudiantes del itinerario, así como los resultados de las encuestas oficiales de la UPC realizadas por los estudiantes. El resultado principal de este estudio pone de manifiesto que se trata de una buena experiencia docente en HCI., Este trabajo ha sido posible gracias a la ayuda económica que procede del programa MINECO y fondos FEDER, DPI2016-77271-R., Peer Reviewed, Objectius de Desenvolupament Sostenible::4 - Educació de Qualitat::4.3 - Per a 2030, assegurar l’accés en condicions d’igualtat per a tots els homes i dones a una formació tècnica, professional i superior de qualitat, inclòs l’ensenyament universitari, Objectius de Desenvolupament Sostenible::4 - Educació de Qualitat, Objectius de Desenvolupament Sostenible::4 - Educació de Qualitat::4.5 - Per a 2030, eliminar les disparitats de gènere en l’educació i garantir l’accés en condicions d’igualtat a les persones vulnerables, incloses les persones amb discapacitat, els pobles indígenes i els nens i nenes en situacions de vulnerabilitat, a tots els nivells de l’ensenyament i la formació professional, Objectius de Desenvolupament Sostenible::4 - Educació de Qualitat::4.7 - Per a 2030, garantir que tot l’alumnat adquireixi els coneixements teòrics i pràctics necessaris per a pro­moure el desenvolupament sostenible, a través, entre d’altres, de l’educació per al desenvolupament sostenible i l’adopció d’estils de vida sostenibles, els drets humans, la igualtat de gènere, la promoció d’una cultura de pau i no-violència, la ciutadania mundial i la valoració de la diversitat cultural i de la contribució de la cultura al desenvolupament sostenible, Objectius de Desenvolupament Sostenible::9 - Indústria, Innovació i Infraestructura, Objectius de Desenvolupament Sostenible::9 - Indústria, Innovació i Infraestructura::9.c - Augmentar de forma significativa l’accés a les tecnologies de la informació i la comunicació i esforçar-se a proporcionar accés universal i assequible a Internet als països menys avançats a tot tardar el 2020, Objectius de Desenvolupament Sostenible::10 - Reducció de les Desigualtats, Objectius de Desenvolupament Sostenible::16 - Pau, Justícia i Institucions Sòlides, Objectius de Desenvolupament Sostenible::16 - Pau, Justícia i Institucions Sòlides::16.6 - Crear unes institucions eficaces, responsables i transparents a tots els nivells, Objectius de Desenvolupament Sostenible::16 - Pau, Justícia i Institucions Sòlides::16.7 - Garantir l’adopció de decisions inclusives, participatives i representatives que responguin a les necessitats a tots els nivells, Objectius de Desenvolupament Sostenible::16 - Pau, Justícia i Institucions Sòlides::16.10 - Garantir l’accés públic a la informació i protegir les llibertats fonamentals, de conformitat amb les lleis nacionals i els acords internacionals, Objectius de Desenvolupament Sostenible::10 - Reducció de les Desigualtats::10.2 - Per a 2030, potenciar i promoure la inclusió social, econòmica i política de totes les persones, independentment de l’edat, sexe, discapacitat, raça, ètnia, origen, religió, situació econòmica o altra condició, Objectius de Desenvolupament Sostenible::10 - Reducció de les Desigualtats::10.3 - Garantir la igualtat d’oportunitats i reduir la desigualtat dels resultats, també eli­minant les lleis, polítiques i pràctiques discriminatòries i promovent legislació, polítiques i mesures adequades a aquest efecte, Postprint (published version)
Dipòsit Digital de Documents de la UAB
Publicación Artículo científico (JournalArticle)

Maximum Power Point Tracking of Photovoltaic Panels by Using Improved Pattern Search Methods

  • Tobón, Andrés
  • Peláez-Restrepo, Julián
  • Villegas-Ceballos, Juan P.
  • Serna-Garcés, Sergio Ignacio
  • Herrera, Jorge|||0000-0003-0273-4043
This paper deals with the optimization of maximum power point tracking when a photovoltaic panel is modelled as two diodes. The adopted control is implemented using a sliding mode control (SMC) and the optimization is implemented using an improved Pattern Search Method. Thus, the problem of maximum power point tracking is reduced to an optimization problem whose solution is implemented by Pattern Search Techniques, inheriting their convergence properties. Simulation examples show the effectiveness of the proposed technique in practice, being able to deal with different radiations. In addition, improved pattern search method (IPSM) is compared with other techniques such as perturb & observe and Particle Swarm optimization, after which IPSM presents lower energy losses in comparison with the other two algorithms, with the advantage of ensuring the location of the optimal power point in all cases.
Dipòsit Digital de Documents de la UAB
Publicación Artículo científico (JournalArticle)

A switched multicontroller for an SEIADR epidemic model with monitored equilibrium points and supervised transients and vaccination costs

  • De la Sen, Manuel|||0000-0001-9320-9433
  • Agarwal, Ravi P.|||0000-0003-0075-1704
  • Nistal, Raul|||0000-0003-2196-1989
  • Alonso-Quesada, Santiago|||0000-0002-4724-7583
  • Ibeas, Asier|||0000-0001-5094-3152
This paper presents a multicontroller structure for an SEIADR (susceptible-exposed-symptomatic infectious-asymptomatic infectious-dead lying bodies recovered by immunity, or immune, subpopulations) epidemic model, which has three different controls involving feedback, namely, the vaccination on the susceptible subpopulation, the antiviral treatment on the symptomatic infectious subpopulation, and the impulsive removal on the infective lying bodies. The incorporation of the asymptomatic infectious and infective dead bodies to SEIR-type models allows a better modeling of diseases where the death bodies are infective as, for instance, the Ebola disease. The proposed supervised multicontroller scheme consists of a parallel disposal of several alternative controller parameterizations together with a switching scheme that chooses the active controller through consecutive time intervals via a supervisory decision scheme. The supervisory scheme decides to switch or not at testing time instants. Switching is performed to a distinct active scheme to the current active if the tentative controller minimizes the value of a loss function compared to the values of the other control schemes available in the parallel controller disposal. The supervisory loss (or cost) function incorporates several additive weighted terms including the infection loss function evolution and the vaccination, antiviral treatment, and bodies removal efforts.
Dipòsit Digital de Documents de la UAB
Publicación Artículo científico (JournalArticle)

On a SIR model in a patchy environment under constant and feedback decentralized controls with asymmetric parameterizations

  • De la Sen, Manuel|||0000-0001-9320-9433
  • Ibeas, Asier|||0000-0001-5094-3152
  • Alonso-Quesada, Santiago|||0000-0002-4724-7583
  • Nistal, Raul|||0000-0003-2196-1989
This paper presents a formal description and analysis of an SIR (involving susceptibleinfectious- recovered subpopulations) epidemic model in a patchy environment with vaccination controls being constant and proportional to the susceptible subpopulations. The patchy environment is due to the fact that there is a partial interchange of all the subpopulations considered in the model between the various patches what is modelled through the so-called travel matrices. It is assumed that the vaccination controls are administered at each community health centre of a particular patch while either the total information or a partial information of the total subpopulations, including the interchanging ones, is shared by all the set of health centres of the whole environment under study. In the case that not all the information of the subpopulations distributions at other patches are known by the health centre of each particular patch, the feedback vaccination rule would have a decentralized nature. The paper investigates the existence, allocation (depending on the vaccination control gains) and uniqueness of the disease-free equilibrium point as well as the existence of at least a stable endemic equilibrium point. Such a point coincides with the disease-free equilibrium point if the reproduction number is unity. The stability and instability of the disease-free equilibrium point are ensured under the values of the disease reproduction number guaranteeing, respectively, the un-attainability (the reproduction number being less than unity) and stability (the reproduction number being more than unity) of the endemic equilibrium point. The whole set of the potential endemic equilibrium points is characterized and a particular case is also described related to its uniqueness in the case when the patchy model reduces to a unique patch. Vaccination control laws including feedback are proposed which can take into account shared information between the various patches. It is not assumed that there are in the most general case, symmetry-type constrains on the population fluxes between the various patches or in the associated control gains parameterizations.
Dipòsit Digital de Documents de la UAB
Publicación Artículo científico (JournalArticle)

Parametrical non-complex tests to evaluate partial decentralized linear-output feedback control stabilization conditions from their centralized stabilization counterparts

  • De la Sen, Manuel|||0000-0001-9320-9433
  • Ibeas, Asier|||0000-0001-5094-3152
This paper formulates sufficiency-type linear-output feedback decentralized closed-loop stabilization conditions if the continuous-time linear dynamic system can be stabilized under linear output-feedback centralized stabilization. The provided tests are simple to evaluate, while they are based on the quantification of the sufficiently smallness of the parametrical error norms between the control, output, interconnection and open-loop system dynamics matrices and the corresponding control gains in the decentralized case related to the centralized counterpart. The tolerance amounts of the various parametrical matrix errors are described by the maximum allowed tolerance upper-bound of a small positive real parameter that upper-bounds the various parametrical error norms. Such a tolerance is quantified by considering the first or second powers of such a small parameter. The results are seen to be directly extendable to quantify the allowed parametrical errors that guarantee the closed-loop linear output-feedback stabilization of a current system related to its nominal counterpart. Furthermore, several simulated examples are also discussed.
Dipòsit Digital de Documents de la UAB
Publicación Artículo científico (JournalArticle)

Discrete-time first-order plus dead-time model-reference trade-off PID control design

  • Kurokawa, Ryo
  • Sato, Takao|||0000-0003-0590-3594
  • Vilanova, Ramon|||0000-0002-8035-5199
  • Konishi, Yasuo
The present study proposes a novel proportional-integral-derivative (PID) control design method in discrete time. In the proposed method, a PID controller is designed for first-order plus dead-time (FOPDT) systems so that the prescribed robust stability is accomplished. Furthermore, based on the control performance, the relationship between the servo performance and the regulator performance is a trade-off relationship, and hence, these items are not simultaneously optimized. Therefore, the proposed method provides an optimal design method of the PID parameters for optimizing the reference tracking and disturbance rejection performances, respectively. Even though such a trade-off design method is being actively researched for continuous time, few studies have examined such a method for discrete time. In conventional discrete time methods, the robust stability is not directly prescribed or available systems are restricted to systems for which the dead-time in the continuous time model is an integer multiple of the sampling interval. On the other hand, in the proposed method, even when a discrete time zero is included in the controlled plant, the optimal PID parameters are obtained. In the present study, as well as the other plant parameters, a zero in the FOPDT system is newly normalized, and then, a universal design method is obtained for the FOPDT system with the zero. Finally, the effectiveness of the proposed method is demonstrated through numerical examples.
Dipòsit Digital de Documents de la UAB
Publicación Artículo científico (JournalArticle)

Optimal control of wastewater treatment plants using economic-oriented model predictive dynamic strategies

  • Revollar, Silvana|||0000-0001-9869-6437
  • Vega, Pastora|||0000-0002-3504-2273
  • Vilanova, Ramon|||0000-0002-8035-5199
  • Francisco, Mario|||0000-0002-6505-0936
This paper addresses the implementation of economic-oriented model predictive controllers for the dynamic real-time optimization of the operation of wastewater treatment plants (WWTP). Both the economic-optimizing controller (pure-EMPC) and the economic-oriented tracking controller (Hybrid-EMPC, or HEMPC) formulations are validated in the benchmark simulation model (BSM1) platform that represents the behavior of a characteristic activated sludge process. The objective of the controllers is to ensure the appropriate operation of the plant, while minimizing the energy consumption and the fines for violations of the limits of the ammonia concentration in the effluent along the full operating period. A non-linear reduced model of the activated sludge process is used for predictions to obtain a reasonable computing effort, and techniques to deal with model-plant mismatch are incorporated in the controller algorithm. Different designs and structures are compared in terms of process performance and energy costs, which show that the implementation of the proposed control technique can produce significant economic and environmental benefits, depending on the desired performance criteria.
Dipòsit Digital de Documents de la UAB
Publicación Artículo científico (JournalArticle)

Some formal results on positivity, stability, and endemic steady-state attainability based on linear algebraic tools for a class of epidemic models with eventual incommensurate delays

  • De la Sen, Manuel|||0000-0001-9320-9433
  • Nistal, Raul|||0000-0003-2196-1989
  • Alonso-Quesada, Santiago|||0000-0002-4724-7583
  • Ibeas, Asier|||0000-0001-5094-3152
A formal description of typical compartmental epidemic models obtained is presented by splitting the state into an infective substate, or infective compartment, and a noninfective substate, or noninfective compartment. A general formal study to obtain the reproduction number and discuss the positivity and stability properties of equilibrium points is proposed and formally discussed. Such a study unifies previous related research and it is based on linear algebraic tools to investigate the positivity and the stability of the linearized dynamics around the disease-free and endemic equilibrium points. To this end, the complete state vector is split into the dynamically coupled infective and noninfective compartments each one containing the corresponding state components. The study is then extended to the case of commensurate internal delays when all the delays are integer multiples of a base delay. Two auxiliary delay-free systems are defined related to the linearization processes around the equilibrium points which correspond to the zero delay, i.e., delay-free, and infinity delay cases. Those auxiliary systems are used to formulate stability and positivity properties independently of the delay sizes. Some examples are discussed to the light of the developed formal study.
Dipòsit Digital de Documents de la UAB
Publicación Artículo científico (JournalArticle)

LSTM-Based Wastewater Treatment Plants Operation Strategies for Effluent Quality Improvement

  • Pisa, Ivan|||0000-0003-3931-9257
  • Santín López, Ignacio|||0000-0002-4312-1035
  • Morell, Antoni|||0000-0003-2249-8594
  • Lopez Vicario, Jose|||0000-0002-3574-4697
  • Vilanova, Ramon|||0000-0002-8035-5199
Wastewater Treatment Plants (WWTPs) are facilities devoted to managing and reducing the pollutant concentrations present in the urban residual waters. Some of them consist in nitrogen and phosphorus derived products which are harmful for the environment. Consequently, certain constraints are applied to pollutant concentrations in order to make sure that treated waters comply with the established regulations. In that sense, efforts have been applied to the development of control strategies that help in the pollutant reduction tasks. Furthermore, the appearance of Artificial Neural Networks (ANNs) has encouraged the adoption of predictive control strategies. In such a fashion, this work is mainly focused on the adoption and development of them to actuate over the pollutant concentrations only when predictions of effluents determine that violations will be produced. In that manner, the overall WWTP's operational costs can be reduced. Predictions are generated by means of an ANN-based Soft-Sensor which adopts Long-Short Term Memory cells to predict effluent pollutant levels. These are the ammonium (S-{NH,e}) and the total nitrogen (S-{Ntot,e}) which are predicted considering influent parameters such as the ammonium concentration at the entrance of the WWTP reactor tanks (S-{NH,po}), the reactors' input flow rate (Q-{po}), the WWTP recirculation rate (Q-{a}) and the environmental temperature (T-{as}). Moreover, this work presents a new multi-objective control scenario which consists in a unique control structure performing the reduction of S-{NH,e} and S-{Ntot,e} concentrations simultaneously. Performance of this new control approach is contrasted with other strategies to determine the improvement provided by the ANN-based Soft-Sensor as well as by the fact of being controlling two pollutants at the same time. Results show that some brief and small violations are still produced. Nevertheless, an improvement in the WWTPs performance w.r.t.The most common control strategies around 96.58% and 98.31% is achieved for S-{NH,e} and S-{Ntot,e}, respectively.
Dipòsit Digital de Documents de la UAB
Publicación Artículo científico (JournalArticle)

New results on positive realness in the presence of delayed dynamics

  • De la Sen, Manuel|||0000-0001-9320-9433
  • Ibeas, Asier|||0000-0001-5094-3152
Positive realness is a very important tool for the achievement of hyperstability and passivity of dynamic systems. This paper is devoted to extend some positive realness results of transfer functions in the presence of point-delayed delayed dynamics. Sufficiency-type conditions which guarantee the positive realness of delayed transfer functions under point delays are given. The value of the direct input-output interconnection gain is seen to be crucial in the performed analysis. The relevance of the results in potential applications rely in the importance of the hyperstability property of closed-loop systems under non-linear and time-varying controller devices. In fact, if the feed-forward controlled plant has a strictly positive real transfer function, then the closed-loop system is asymptotically hyperstable, that is, globally asymptotically Lyapunov's stable for any non-linear time-varying controller which belongs to a hyperstable class defined as that which satisfies a Popov's type inequality.
Dipòsit Digital de Documents de la UAB
Publicación Artículo científico (JournalArticle)

ANN-based soft sensor to predict effluent violations in wastewater treatment plants

  • Pisa, Ivan|||0000-0003-3931-9257
  • Santín López, Ignacio|||0000-0002-4312-1035
  • Lopez Vicario, Jose|||0000-0002-3574-4697
  • Morell, Antoni|||0000-0003-2249-8594
  • Vilanova, Ramon|||0000-0002-8035-5199
Wastewater treatment plants (WWTPs) form an industry whose main goal is to reduce water's pollutant products, which are harmful to the environment at high concentrations. In addition, regulations are applied by administrations to limit pollutant concentrations in effluent. In this context, control strategies have been adopted by WWTPs to avoid violating these limits; however, some violations still occur. For that reason, this work proposes the deployment of an artificial neural network (ANN)-based soft sensor in which a Long-Short Term Memory (LSTM) network is used to generate predictions of nitrogen-derived components, specifically ammonium (S ) and total nitrogen (S ). S is a limiting nutrient and can therefore cause eutrophication, while nitrogen in the S form is toxic to aquatic life. These parameters are used by control strategies to allow actions to be taken in advance and only when violations are predicted. Since predictions complement control strategies, the evaluation of the ANN-based soft sensor was carried out using the Benchmark Simulation Model N.2. (BSM2) and three different control strategies (from low to high control complexity). Results show that our proposed method is able to predict nitrogen-derived products with good accuracy: the probability of detecting violations of BSM2's limits is 86-94%. Moreover, the prediction accuracy can be improved by calibrating the soft sensor; for example, perfect prediction of all future violations can be achieved at the expense of increasing the false positive rate.
Dipòsit Digital de Documents de la UAB
Publicación Artículo científico (JournalArticle)

Control deslizante fraccionario de la trayectoria y orientación de un quadrotor con cargas suspendidas desconocidas, Sliding fractional order trajectory and attitude control of a quadrotor transporting cable-suspended unknown payloads

  • Ullah, Nasim|||0000-0001-7208-6374
  • Ali, Muhammad Asghar
  • Ibeas, Asier|||0000-0001-5094-3152
  • Herrera, Jorge|||0000-0003-0273-4043
Este artículo diseña un sistema de control para el problema de seguimiento de trayectorias de un vehículo quadrotor con una carga suspendida desconocida. La presencia de esta carga desconocida incrementa considerablemente la complejidad del problema, y su oscilación actúa como una perturbación incierta que afecta a la dinámica propia del vehículo. De esta forma, la trayectoria global del quadrotor puede verse enormemente afectada a pesar de la existencia de un controlador nominal para él. Este artículo propone el diseño de un control deslizante de orden fraccionario para la solución de este problema. Junto con el diseño de la ley de control se prueba la estabilidad del sistema en lazo cerrado a través del método de Lyapunov para sistemas fraccionarios. El desempeño obtenido por el controlador propuesto se compara con el control en modo deslizante clásico observando que el controlador propuesto mejora significativamente los resultados obtenidos., This article designs a control system for the trajectory tracking problem of a quadrotor vehicle with an unknown suspended load. The presence of this unknown load considerably increases the complexity of the problem while its oscillation acts as an unknown perturbation that affects the dynamics of the vehicle. In this way, the overall trajectory of the quadrotor can be greatly affected despite the existence of a nominal controller for it. This article proposes the design of a fractional order sliding mode control for the solution of this problem. Along with the design of the control law, the stability proof of the closed-loop system is carried out by using the Lyapunov method for fractional systems. The performance obtained by the proposed controller is compared with the classic sliding mode control, observing that the proposed controller significantly improves the results.
Dipòsit Digital de Documents de la UAB
Publicación Artículo científico (JournalArticle)

Denoising Autoencoders and LSTM-Based Artificial Neural Networks Data Processing for Its Application to Internal Model Control in Industrial Environments-The Wastewater Treatment Plant Control Case

  • Pisa, Ivan|||0000-0003-3931-9257
  • Morell, Antoni|||0000-0003-2249-8594
  • Lopez Vicario, Jose|||0000-0002-3574-4697
  • Vilanova, Ramon|||0000-0002-8035-5199
The evolution of industry towards the Industry 4.0 paradigm has become a reality where different data-driven methods are adopted to support industrial processes. One of them corresponds to Artificial Neural Networks (ANNs), which are able to model highly complex and non-linear processes. This motivates their adoption as part of new data-driven based control strategies. The ANN-based Internal Model Controller (ANN-based IMC) is an example which takes advantage of the ANNs characteristics by modelling the direct and inverse relationships of the process under control with them. This approach has been implemented in Wastewater Treatment Plants (WWTP), where results show a significant improvement on control performance metrics with respect to (w.r.t.) the WWTP default control strategy. However, this structure is very sensible to non-desired effects in the measurements-when a real scenario showing noise-corrupted data is considered, the control performance drops. To solve this, a new ANN-based IMC approach is designed with a two-fold objective, improve the control performance and denoise the noise-corrupted measurements to reduce the performance degradation. Results show that the proposed structure improves the control metrics, (the Integrated Absolute Error (IAE) and the Integrated Squared Error (ISE)), around a 21.25% and a 54.64%, respectively.
Dipòsit Digital de Documents de la UAB
Publicación Artículo científico (JournalArticle)

Permeate Flux Control in SMBR System by Using Neural Network Internal Model Control

  • Wahab, Norhaliza Abdul
  • Mahmod, Nurazizah
  • Vilanova, Ramon|||0000-0002-8035-5199
This paper presents a design of a data-driven-based neural network internal model control for a submerged membrane bioreactor (SMBR) with hollow fiber for microfiltration. The experiment design is performed for measurement of physical parameters from an actuator input (permeate pump voltage), which gives the information (outputs) of permeate flux and trans-membrane pressure (TMP). The palm oil mill effluent is used as an influent preparation to depict fouling phenomenon in the membrane filtration process. From the experiment, membrane fouling potential is observed from flux decline pattern, with a rapid increment of TMP (above 200 mbar). Membrane fouling is a complex process and the available models in literature are not designed for control system (filtration performance). Therefore, this work proposes an aeration fouling control strategy to measure the filtration performance. The artificial neural networks (Feed-Forward Neural Network-FFNN, Radial Basis Function Neural Network-RBFNN and Nonlinear Autoregressive Exogenous Neural Network-NARXNN) are used to model dynamic behaviour of flux and TMP. In this case, only flux is used in closed loop control application, whereby the TMP effect is used for monitoring. The simulation results show that reliable prediction of membrane fouling potential is obtained. It can be observed that almost all the artificial neural network (ANN) models have similar shape with the actual data set, with the highest accuracy of more than 90% for both RBFNN and NARXN. The RBFNN is preferable due to simple structure of the network. In the control system, the RBFNN IMC depicts the highest closed loop performance with only 3.75 s (settling time) for setpoint changes when compared with other controllers. In addition, it showed fast performance in disturbance rejection with less overshoot. In conclusion, among the different neural network tested configurations the one based on radial basis function provides the best performance with respect to prediction as well as control performance.
Dipòsit Digital de Documents de la UAB
Publicación Artículo científico (JournalArticle)

Global Internal Recirculation Alternative Operation to Reduce Nitrogen and Ammonia Limit Violations and Pumping Energy Costs in Wastewater Treatment Plants

  • Santín López, Ignacio|||0000-0002-4312-1035
  • Barbu, Marian|||0000-0001-6645-3705
  • Vilanova, Ramon|||0000-0002-8035-5199
  • Pedret Ferré, Carles|||0000-0001-8633-2548
  • Barbu, Marian|||0000-0001-6645-3705
The internal recirculation plays an important role in different areas of the biological treatment of wastewater treatment plants because it has a great influence on the concentration of pollutants, especially nutrients. A usual manipulation of the internal recirculation flow rate is based on the target of controlling the nitrate concentration in the last anoxic tank. This work proposes an alternative for the manipulation of the internal recirculation flow rate instead of nitrate control, with the objective of avoiding limit violations of nitrogen and ammonia concentrations and reducing operational costs. A fuzzy controller is proposed to achieve it based on the effects of the internal recirculation flow rate in different areas of the biological treatment. The proposed manipulation of the internal recirculation flow rate is compared to the application of the usual nitrate control in an already established and published operation strategy by using the internationally known benchmark simulation model no. 2 as a working scenario. The results show improvements with reductions of 59.40% in ammonia limit violations, 2.35% in total nitrogen limit violations, and 38% in pumping energy costs.
Dipòsit Digital de Documents de la UAB
Publicación Artículo científico (JournalArticle)

Industrial Control under Non-Ideal Measurements, Data-Based Signal Processing as an Alternative to Controller Retuning

  • Pisa, Ivan|||0000-0003-3931-9257
  • Morell, Antoni|||0000-0003-2249-8594
  • Vilanova, Ramon|||0000-0002-8035-5199
  • Lopez Vicario, Jose|||0000-0002-3574-4697
Industrial environments are characterised by the non-lineal and highly complex processes they perform. Different control strategies are considered to assure that these processes are correctly performed. Nevertheless, these strategies are sensible to noise-corrupted and delayed measurements. For that reason, denoising techniques and delay correction methodologies should be considered but, most of these techniques require a complex design and optimisation process as a function of the scenario where they are applied. To alleviate this, a complete data-based approach devoted to denoising and correcting the delay of measurements is proposed here with a two-fold objective: simplify the solution design process and achieve its decoupling from the considered control strategy as well as from the scenario. Here it corresponds to a Wastewater Treatment Plant (WWTP). However, the proposed solution can be adopted at any industrial environment since neither an optimization nor a design focused on the scenario is required, only pairs of input and output data. Results show that a minimum Root Mean Squared Error (RMSE) improvement of a 63.87% is achieved when the new proposed data-based denoising approach is considered. In addition, the whole system performance show that similar and even better results are obtained when compared to scenario-optimised methodologies.
Dipòsit Digital de Documents de la UAB
Publicación Artículo científico (JournalArticle)

Wastewater treatment plant operation, Simple control schemes with a holistic perspective

  • Revollar, Silvana|||0000-0001-9869-6437
  • Vilanova, Ramon|||0000-0002-8035-5199
  • Vega, Pastora|||0000-0002-3504-2273
  • Francisco, Mario|||0000-0002-6505-0936
  • Meneses, Montse|||0000-0002-5846-2676
In this paper, a control approach for improving the overall efficiency of a wastewater treatment plant (WWTP) is presented. It consists of a cascaded control system that uses a global performance indicator as the controlled variable to drive the plant to operating conditions that satisfies trade-offs involved in the WWTP operation, improving the global performance of the plant. The selected global performance indicator is the N/E index that measures the ratio between the amount of nitrogenated compounds eliminated (kgN) and the energy (kWh) required to achieve that goal. This index links the variables of the activated sludge process with the energy consumed in the whole plant, thus the control strategy takes actions based on plantwide considerations. An external Proportional Integral (PI) controller changes the DO set point according to the N/E index and the basic dissolved oxygen (DO) control scheme in the activated sludge process follows this reference changes varying the aeration intensity. An outer loop with an event-based controller is used to compute the index values when the DO concentration is driven to excessively low limits, preventing long operation periods in this undesirable condition. Simple proportional integral controllers (PI) are used to adapt the strategy to the automation systems available in WWTPs. The implementation in the Benchmark Simulation Model 2 (BSM2) demonstrates the potential of the proposed approach. The results show the possibilities of the N/E index to be used as an indicator of global performance of WWTPs. It provides a link between water line objectives and energy consumption in the whole plant that can be exploited to introduce plantwide considerations in alternative control strategies formulated to drive the plant to operating conditions that optimize the overall process efficiency.
Dipòsit Digital de Documents de la UAB
Publicación Artículo científico (JournalArticle)

Quantifying the benefit of a dynamic performance assessment of WWTP

  • Revollar, Silvana|||0000-0001-9869-6437
  • Meneses, Montse|||0000-0002-5846-2676
  • Vilanova, Ramon|||0000-0002-8035-5199
  • Vega, Pastora|||0000-0002-3504-2273
  • Francisco, Mario|||0000-0002-6505-0936
In this work a comprehensive analysis of the environmental impact of the operation of a wastewater treatment plant (WWTP) using different control strategies is carried out considering the dynamic evolution of some environmental indicators and average operation costs. The selected strategies are PI (proportional integral) control schemes such as dissolved oxygen control in the aerobic zone (DO control), DO control and nitrates control in the anoxic zone (DO + NO control) and regulation of ammonium control at the end of aerobic zone (Cascade Scommonly used in WWTPs to maintain the conditions that ensure the desired effluent quality in a variable influent scenario. The main novelty of the work is the integration of potential insights into environmental impact from the analysis of dynamic evolution of environmental indicators at different time scales. The consideration of annual, bimonthly and weekly temporal windows to evaluate performance indicators makes it possible to capture seasonal effects of influent disturbances and control actions on environmental costs of wastewater treatment that are unnoticed in the annual-based performance evaluation. Then, in the case of periodic events, it is possible to find solutions to improve operation by the adjustment of the control variables in specific periods of time along the operation horizon. The analysis of the annual average and dynamic profiles (weekly and bimonthly) of environmental indicators showed that ammonium-based control (Cascade S) produce the best compromise solution between environmental and operation costs compared with DO control and DO + NO control. An alternative control strategy, named S Q , has been defined considering a sequence of changes on ammonium set-point (S) and carbon dosage (Q) on different temporal windows. It is compared with DO control considering weekly and bimonthly profiles and annual average values leading to the conclusion that both strategies, Cascade S and S Q , produce an improvement of dynamic and annual average environmental performance and operation costs, but benefits of Cascade S strategy are associated with reduction of electricity consumption and emissions to water, while S Q strategy reduces electricity consumption, use of chemicals (reducing external carbon dosage) and operation costs.
Dipòsit Digital de Documents de la UAB
Publicación Artículo científico (JournalArticle)

New approach for regulation of the internal recirculation flow rate by fuzzy logic in biological wastewater treatments

  • Santín López, Ignacio|||0000-0002-4312-1035
  • Vilanova, Ramon|||0000-0002-8035-5199
  • Pedret Ferré, Carles|||0000-0001-8633-2548
  • Barbu, Marian|||0000-0001-6645-3705
The internal recirculation plays an important role on the different biological processes of wastewater treatment plants because it has a great influence on the concentration of pollutants, especially nutrients. Usually, the internal recirculation flow rate is kept fixed or manipulated by control techniques to maintain a fixed nitrate set-point in the last anoxic tank. This work proposes a new control strategy to manipulate the internal recirculation flow rate by applying a fuzzy controller. The proposed controller takes into account the effects of the internal recirculation flow rate on the inlet of the biological treatment and on the denitrification and nitrification processes with the aim of reducing violations of legally established limits of nitrogen and ammonia and also reducing operational costs. The proposed fuzzy controller is tested by simulation with the internationally known benchmark simulation model no. 2. The objective is to apply the proposed fuzzy controller in any control strategy, only replacing the manipulation of the internal recirculation flow rate, to improve the plant operation.Therefore, it has been implemented in five operation strategies from the literature, replacing their original internal recirculation flow rate control, and simulation results are compared with those of the original strategies. Results show improvements with the application of the proposed fuzzy controller of between 2.25 and 57.94% in reduction of total nitrogen limit violations, between 55.22 and 79.69% in reduction of ammonia limit violations and between 0.84 and 38.06% in cost reduction of pumping energy.