Pasar al contenido principal

IDENTIFICACION DE BARRERAS Y OPORTUNIDADES SOSTENIBLES EN LOS MATERIALES Y APLICACIONES DEL ALMACENAMIENTO DE ENERGIA TERMICA

ENE2015-64117-C5-3-R

•
Nombre agencia financiadora Ministerio de Economía y Competitividad
Acrónimo agencia financiadora MINECO
Programa Programa Estatal de I+D+i Orientado a los Retos de la Sociedad
Convocatoria Proyectos I+D+i Retos de Investigación
Año convocatoria 2015
Plan Estatal 2013-2016 Plan Estatal de Investigación Científica y Técnica y de Innovación
Unidad de gestión Dirección General de Investigación Científica y Técnica
Centro beneficiario UNIVERSITAT ROVIRA I VIRGILI
Identificador persistente http://dx.doi.org/10.13039/501100003329

Resultados relacionados

Resultados totales (Incluyendo duplicados): 58
Encontrada(s) 1 página(s)

RUA. Repositorio Institucional de la Universidad de Alicante
Publicación Otros (Other)

Systematic approach for the life cycle multi-objective optimization of buildings combining objective reduction and surrogate modeling

  • Carreras, Joan
  • Pozo, Carlos
  • Boer, Dieter
  • Guillén Gosálbez, Gonzalo
  • Caballero, José A.
  • Ruiz-Femenia, Rubén
  • Jiménez, Laureano
  • Caballero, José A.|||/items/0b1eee1e-07bb-4833-80b0-a697525119aa
  • Ruiz-Femenia, Rubén|||/items/683ccf87-4e50-4796-8968-7b489c75cad8
With the recent trend of moving towards a more sustainable economy, the interest on designing buildings with lower cost and environmental impact has grown significantly. In this context, multi-objective optimization has attracted much attention in building design as a tool to study trade-off solutions (“cost” vs “environmental impact”) resulting from the optimization of conflicting objectives. One major limitation of this approach (as applied to building design) is that it is computationally demanding due to the need to optimize several objectives using complex models based on differential equations (which are used to estimate the energy consumed by a building). In this work, we propose a systematic framework for the design of buildings that combines a rigorous objective reduction method (which removes redundant objectives from the analysis) with a surrogate model (which simplifies the calculation of the energy requirements of the building), both of which expedite the identification of alternative designs leading to environmental improvements. The capabilities of our methodology are illustrated through a case study based on a thermal modelling of a house-like cubicle, in which we optimize the insulation thicknesses of the building envelope. Results show that significant economic and environmental improvements can be achieved compared to the base case (cubicle without insulation). Furthermore, it is clearly illustrated how the minimization of an aggregated environmental metric, like the Eco-Indicator 99, as unique environmental objective may overlook some Pareto solutions that may be appealing for decision-makers.
Repositori Obert UdL
Publicación Artículo científico (JournalArticle)

Optimized demand side management (DSM) of peak electricity demand by coupling low temperature thermal energy storage (TES) and solar PV

  • Saffari Tabalvandani, Mohammad
  • Gracia Cuesta, Alvaro de
  • Fernàndez Camon, César
  • Belusko, Martin
  • Boer, Dieter
  • Cabeza, Luisa F.
Cooling in the industry sector contributes significantly to the peak demand placed on an electrical utility grid. New electricity tariff structures include high charges for electricity consumption in peak hours which leads to elevated annual electricity costs for high-demanding consumers. Demand side management (DSM) is a promising solution to increase the energy efficiency among customers by reducing their electricity peak demand and consumption. In recent years, researchers have shown an increased interest in utilizing DSM techniques with thermal energy storage (TES) and solar PV technologies for peak demand reduction in industrial and commercial sectors. The main objective of the present study is to address the potential for applying optimization-based time-of-use DSM in the industry sector by using cold thermal energy storage and off-grid solar PV to decrease and shift peak electricity demands and to reduce the annual electricity consumption costs. The results show that when cold thermal energy storage and solar PV are coupled together higher annual electricity cost savings can be achieved compared to using these two technologies independently. Additionally, considerable reductions can be seen in electricity power demands in different tariff periods by coupling thermal energy storage with off-grid solar PV., The work partially funded by the Spanish government (ENE2015-64117-C5-1-R (MINECO/FEDER), ENE2015-64117-C5-3-R (MINECO/FEDER), and TIN2015-71799-C2-2-P). The authors would like to thank the Catalan Government for the quality accreditation given to their research group (2014 SGR 123) and the city hall of Puigverd de Lleida. This project has received funding from the European Union’s Horizon 2020 research and innovation programme under grant agreement No 657466 (INPATH-TES). Alvaro de Gracia would like to thank Ministerio de Economia y Competitividad de España for Grant Juan de la Cierva, FJCI-2014-19940.
Repositori Obert UdL
Publicación Artículo científico (JournalArticle)

Model predictive control strategy applied to different types of building for space heating

  • Gholamibozanjani, Gohar
  • Tarragona Roig, Joan
  • Gracia Cuesta, Alvaro de
  • Fernàndez Camon, César
  • Cabeza, Luisa F.
  • Farid, Mohammed M.
In recent years, the concept of energy-efficient buildings has attracted widespread attention due to growing energy consumption in different types of buildings. The application of thermal energy storage (TES) systems, especially latent heat energy storage (LHES), has become a promising approach to improve thermal efficiency of buildings and hence reduce CO2 emissions. One way to achieve this, could be by implementing a model predictive control (MPC) strategy, using weather and electricity cost predictions. To this end, a heat exchanger unit containing a phase change material (PCM) as a LHES medium, thermally charged by solar energy was incorporated into three versions of a standard building. This paper reports on the use of EnergyPlus software to simulate the heating demand profile of these buildings, with Solving Constraint Integer Programs (SCIP) as the optimization tool. After applying MPC strategy, the energy costs of different building types were evaluated. Furthermore, the effect of prediction horizon and decision time step of MPC strategy, and PCM mass capacity on the performance of the MPC were all investigated in 1 and 7-day simulations. Results showed that by increasing the prediction horizon and PCM mass, more cost saving could be obtained. However, in terms of decision time step, although the study revealed that increasing it led to a higher energy saving, it made the system more sensitive to sharp changes as it failed to provide an accurate reading of the parameters and variables., The study was partially funded by the Spanish Government (ENE2015-64117-C5-1-R (MINECO/FEDER) and ENE2015-64117-C5-3-R (MINECO/FEDER)). The authors at the University of Lleida would like to thank the Catalan Government for the quality accreditation given to their research group (2017 SGR 1537). GREiA is the certified agent for TECNIO in the category technology developers for the Government of Catalonia. The research leading to these results also received funding from the European Union's Seventh Framework Programme (FP7/2007-2013) under grant agreement no. PIRSES-GA-2013-610692 (INNOSTORAGE).
Repositori Obert UdL
Publicación Artículo científico (JournalArticle)

Experimental validation of the exact analytical solution to the steady periodic heat transfer problem in a PCM layer

  • Mazzeo, Domenico
  • Oliveti, Giuseppe
  • Gracia, Álvaro de
  • Coma Arpón, Julià
  • Solé, Aran
  • Cabeza, Luisa F.
Phase change materials (PCM) are used in many industrial and residential applications for their advantageous characteristic of high capacity of latent thermal storage by means of an isothermal process. In this context, it is very useful to have predictive mathematical models for the analysis of the thermal performance and for the thermal design of these layers. In this work, an experimental validation of an analytical model that resolves the steady periodic heat transfer problem in a finite layer of PCM is presented. The experimental investigation was conducted employing a PCM with thermophysical and thermochemical behavior very close to those hypothesized in the formulation of the analytical model. For the evaluation of the thermophysical properties of the PCM sample used, an experimental procedure created by the authors was employed. In all tests realized in a sinusoidal and non-sinusoidal periodic regime, the comparison between the measured and calculated trends of the temperature at different sample heights and of the surface heat fluxes show an excellent agreement. Moreover, also having verified the analytical total stored energy, the analytical model constitutes a valid instrument for the evaluation of the latent and sensible contribution and the trend in time of the position of the bi-phase interface., The work was partially funded by the Spanish government (ENE2015-64117-C5-1-R (MINECO/FEDER), ENE2015-64117-C5-3-R (MINECO/FEDER), and ULLE10-4E-1305). GREA is certified agent TECNIO in the category of technology developers from the Government of Catalonia. The authors would like to thank the Catalan Government for the quality accreditation given to their research group (2014 SGR 123). This project has received funding from the European Commission Seventh Framework Programme (FP/2007-2013) under Grant agreement Nº PIRSES-GA-2013-610692 (INNOSTORAGE) and from European Union's Horizon 2020 research and innovation programme under grant agreement Nº 657466 (INPATH-TES). Alvaro de Gracia would like to thank Ministerio de Economia y Competitividad de España for Grant Juan de la Cierva, FJCI-2014-19940. Julià Coma would like to thank the Departament d'Universitats, Recerca i Societat de la Informació de la Generalitat de Catalunya for his research fellowship (2016FI_B2 00147). Aran Solé would like to thank Ministerio de Economía y Competitividad de España for Grant Juan de la Cierva, FJCI-2015-25741.
Repositori Obert UdL
Publicación Artículo científico (JournalArticle)

Phase Change Material Selection for Thermal Energy Storage at High Temperature Range between 210 ºC and 270 ºC

  • Maldonado, José Miguel
  • Fullana Puig, Margalida
  • Martín, Marc
  • Solé, Aran
  • Fernández, Ángel G.
  • Gracia Cuesta, Alvaro de
  • Cabeza, Luisa F.
The improvement of thermal energy storage systems implemented in solar technologies increases not only their performance but also their dispatchability and competitiveness in the energy market. Latent heat thermal energy storage systems are one of those storing methods. Therefore, the need of finding the best materials for each application becomes an appealing research subject. The main goal of this paper is to find suitable and economically viable materials able to work as phase change material (PCM) within the temperature range of 210-270 ºC and endure daily loading and unloading processes in a system with Fresnel collector and an organic Rankine cycle (ORC). Twenty-six materials have been tested and characterized in terms of their thermophysical conditions, thermal and cycling stability, and health hazard. Two materials out of the 26 candidates achieved the last stage of the selection process. However, one of the two finalists would require an inert working atmosphere, which would highly increase the cost for the real scale application. This leads to a unique suitable material, solar salt (40 wt % KNO3/60 wt % NaNO3)., This work was partially funded by the European Union’s Horizon 2020 Research & Innovation Programme under Grant Agreement 723596 with reference name Innova MicroSolar. This work was partially funded by the Ministerio de Economía y Competitividad de España (ENE2015-64117-C5-1-R (MINECO/FEDER) and ENE2015-64117-C5-3-R (MINECO/FEDER)). The authors would like to thank the Catalan Government for the quality accreditation given to their research group (2017 SGR 1537). GREA is certified agent TECNIO in the category of technology developers from the Government of Catalonia. José Miguel Maldonado would like to thank the Spanish Government for his research fellowship (BES-2016-076554). Aran Solé would like to thank Ministerio de Economía y Competitividad de España for Grant Juan de la Cierva, FJCI-2015-25741. Alvaro de Gracia has received funding from the European Union’s Horizon 2020 research and innovation programme under the Marie Sklodowska-Curie grant agreement No. 712949. Angel G. Fernández would like to acknowledge the financial support provided by GIZ “Programa de pasantía en el extranjero en tecnologías de concentración solar para investigadores” and CONICYT/FONDAP 15110019 “Solar Energy Research Center” SERC-Chile.
Repositori Obert UdL
Publicación Artículo científico (JournalArticle)

Simulation-based optimization of PCM melting temperature to improve the energy performance in buildings

  • Saffari Tabalvandani, Mohammad
  • Gracia Cuesta, Alvaro de
  • Fernàndez Camon, César
  • Cabeza, Luisa F.
Globally, a considerable amount of energy is consumed by the building sector. The building envelope can highly influence the energy consumption in buildings. In this regard, innovative technologies such as thermal energy storage (TES) can help to boost the energy efficiency and to reduce the CO2 emissions in this sector. The use of phase change materials (PCM), due to its high heat capacity, has been the centre of attention of many researchers. A considerable number of papers have been published on the application of PCM as passive system in building envelopes. Researches have shown that choosing the PCM melting temperature in different climate conditions is a key factor to improve the energy performance in buildings. In the present paper, a simulation-based optimization methodology will be presented by coupling EnergyPlus and GenOpt with an innovative enthalpy-temperature (h-T) function to define the optimum PCM peak melting temperature to enhance the cooling, heating, and the annual total heating and cooling energy performance of a residential building in various climate conditions based on Köppen-Geiger classification. Results show that in a cooling dominant climate the best PCM melting temperature to reduce the annual energy consumption is close to the maximum of 26ºC (melting range of 24ºC-28ºC), whereas in heating dominant climates PCM with lower melting temperature of 20ºC (melting range of 18ºC-22ºC) yields higher annual energy benefits. Moreover, it was found that the proper selection of PCM melting temperature in each climate zone can lead to notable energy savings for cooling energy consumption, heating energy consumption, and total annual energy consumption., The work is partially funded by the Spanish government (ENE2015-64117-C5-1-R (MINECO/FEDER) and ENE2015-64117-C5-3-R (MINECO/FEDER)). The authors would like to thank the Catalan Government for the quality accreditation given to their research group GREA (2014 SGR 123). GREA is certified agent TECNIO in the category of technology developers from the Government of Catalonia. This project has received funding from the European Commission Seventh Framework Program (FP/2007-2013) under Grant agreement Nº PIRSES-GA-2013-610692 (INNOSTORAGE) and from the European Union’s Horizon 2020 research and innovation program under grant agreement No 657466 (INPATH-TES). Alvaro de Gracia would like to thank Ministerio de Economia y Competitividad de España for Grant Juan de la Cierva, FJCI-2014-19940.
Repositori Obert UdL
Publicación Artículo científico (JournalArticle)

Experimental testing of cooling internal loads with a radiant wall

  • Romaní Picas, Joaquim
  • Cabeza, Luisa F.
  • Pérez Luque, Gabriel
  • Pisello, Anna Laura
  • Gracia Cuesta, Alvaro de
Thermally activated building systems (TABS) consist of pipes or ducts embedded in the building structure. This is a well-known technology for its capability to reduce energy use for cooling buildings. Additionally, TABS help integrating renewable energies, such as free-cooling with ground heat exchangers (GHE). However, TABS cooling load is sensitive to the internal load, and the use of GHE for free-cooling is limited to low energy buildings. In a previously published research, a radiant wall cubicle without internal gains demonstrated to achieve significant energy savings. However, the current research showed that under domestic and office scheduled internal gains equivalent to 42 W·m-2 the radiant cubicle increased its energy consumption for cooling more than the reference cubicle with air-to-air heat pumps. As a result, the radiant cubicle used around 20% more energy than the reference at air temperature set-point 24 ºC but saved around 20% compared to the reference at 26 ºC. Despite this, the radiant wall could still reduce the cooling cost through peak load shifting even though it showed to consume more energy than a conventional HP., The work was partially funded by the Spanish government (ENE2015-64117-C5-1-R (MINECO/FEDER), ENE2015-64117-C5-3-R (MINECO/FEDER), and ULLE10-4E-1305). GREA is certified agent TECNIO in the category of technology developers from the Government of Catalonia. The authors would like to thank the Catalan Government for the quality accreditation given to their research group (2014 SGR 123) and the city hall of Puigverd de Lleida. This projects has received funding from the European Commission Seventh Framework Programme (FP/2007–2013) under Grant agreement Nº PIRSES-GA-2013-610692 (INNOSTORAGE) and from European Union's Horizon 2020 research and innovation programme under grant agreement Nº 657466 (INPATH-TES). Alvaro de Gracia would like to thank Ministerio de Economia y Competitividad de España for Grant Juan de la Cierva, FJCI-2014-19940.
Repositori Obert UdL
Publicación Artículo científico (JournalArticle)

Use of partial load operating conditions for latent thermal energy storage management

  • Gasia, Jaume
  • Gracia Cuesta, Alvaro de
  • Peiró Bell-lloch, Gerard
  • Arena, Simone
  • Cau, Giorgio
  • Cabeza, Luisa F.
A proper management of thermal energy storage (TES) charging and discharging processes allows the final users to optimize the performance of TES systems. In this paper, an experimental research is carried out to study how the percentage of charge in a latent heat TES system (partial load operating conditions) influences the discharge process. Several charging and discharging processes were performed at a constant heat transfer fluid (HTF) mass flow rate of 0.5 kg/s and temperature of 155 °C and 105 °C, respectively. High density polyethylene (HDPE) with a total mass of 99.5 kg was used as phase change material (PCM) in a 0.154m3 storage tank based on the shelland-tube heat exchanger concept. Five different percentages of charge have been studied: 58 %, 73 %, 83 %, 92 %, and 97 % (baseline test). Results showed that by modifying the percentage of charge, the time required for the charging process was reduced between 97.2% and 68.8% in comparison to the baseline case. However, the energy accumulated was only reduced a maximum of 35.1% and a minimum of 5.2%, while the heat transfer rates during the first 60 min of discharge were reduced a maximum of 45.8% and a minimum of 6%. Therefore, partially charging the TES system not lower than 85% of its maximum energy capacity becomes a good option if the final application accepts a maximum decrease of discharging heat transfer rates of 10% if compared to the fully charged system., The work was partially funded by the Spanish government (ENE2015-64117-C5-1-R (MINECO/FEDER), ENE2015-64117-C5-3-R (MINECO/FEDER), and ULLE10-4E-1305). The authors would like to thank the Catalan Government for the quality accreditation given to their research group (2014 SGR 123). GREA is certified agent TECNIO in the category of technology developers from the Government of Catalonia. This project has received funding from the European Commission Seventh Framework Programme (FP/2007-2013) under Grant agreement No. PIRSES-GA-2013-610692 (INNOSTORAGE) and from the European Union’s Horizon 2020 research and innovation programme under grant agreement No. 657466 (INPATH-TES). Jaume Gasia would like to thank the Departament d'Universitats, Recerca i Societat de la Informació de la Generalitat de Catalunya for his research fellowship (2017 FI_B1 00092). Alvaro de Gracia would like to thank Ministerio de Economia y Competitividad de España for Grant Juan de la Cierva, FJCI-2014-19940. Simone Arena would like to thank the Department of Mechanical, Chemical and Materials Engineering of the University of Cagliari for funding his research grant.
Repositori Obert UdL
Publicación Artículo científico (JournalArticle)

Simulation and control of thermally activated building systems (TABS)

  • Romaní Picas, Joaquim
  • Gracia Cuesta, Alvaro de
  • Cabeza, Luisa F.
Buildings account for a significant amount of global energy use and CO2 emissions. Thermally Activated Building Systems (TABS) are a technology with potential for significantly reducing buildings energy use. TABS are heating and cooling systems that are integrated in the building structure. They mainly exchange heat through radiation and are able to store heat in the building thermal mass. TABS high thermal mass and their interaction with the building structure make their energy evaluation and design process difficult. Development of simulation models has been essential to study the design and control of TABS. Control of TABS is challenging due to the slow response time and storage capacity. A lot of research has been conducted to develop control strategies that fully exploit its energy saving potential and that maximize the use of renewable energies. This paper summarizes the main characteristics of TABS and presents the developed simulation models and control strategies., The authors would like to thank the Catalan Government for the quality accreditation given to their research group (2014 SGR 123). This projects has received funding from the European Commission Seventh Framework Programme (FP/2007-2013) under Grant agreement N° PIRSES-GA-2013-610692 (INNOSTORAGE) and from European Union’s Horizon 2020 research and innovation programme under grant agreement N° 657466 (INPATH-TES) and from EEA-Grants under grant IDI-20140914. The work was partially funded by the Spanish government grant ENE2015-64117-C5-1-R and grant ENE2015-64117-C5-3-R. Alvaro de Gracia would like to thank Ministerio de Economia y Competitividad de España for Grant Juan de la Cierva, FJCI-2014-19940.
Repositori Obert UdL
Publicación Contribución de congreso (ConferenceOutput)

Benchmarking of energy demand of domestic and small business buildings

  • Coma Arpón, Julià
  • Maldonado, José Miguel
  • Gracia Cuesta, Alvaro de
  • Gimbernat, Toni
  • Botargues, Teresa
  • Cabeza, Luisa F.
Rapid expansion of solar thermal energy for increasing energy efficiency of buildings has been adopted in short/medium and long-term energy strategies of EU countries. This enhancement of energy efficiency in buildings is in line with regional actions with the European climate energy objectives as defined in the European Union’s “20-20-20” targets and in the European Commission’s Energy Roadmap 2050. Within this context, the overall objective of this work is to develop an innovative high performance and cost effective hybrid solar heat and power system, which consist in a novel flat Fresnel mirror solar concentrating collector and micro organic Rankine cycle plant combined with advanced phase change materials as thermal storage, all system managed by smart control units. The initial application is to be implemented in individual dwellings and small business residential buildings for on-site electricity and heat generation using solar thermal energy. It is estimated that the proposed technology will deliver 60% of domestic energy requirements and provide 20% reduction in energy costs and greenhouse gas emissions compared to the best existing low carbon energy technologies. To reach the main objectives, the first step consist in providing information on features of architecture of domestic and small business residential buildings and their annual energy demands for different countries such as: Spain, France Germany, Italy, and United Kingdom. This will include detailed building information of envelopes (walls, roof, lofts, etc.), structure, fabric, and results of energy demands (domestic hot water, space heating and electricity) for the abovementioned countries. This information will be used as input data during the development of this technology as it will point out the potential benefits of the system in different countries, climates, and building typologies., This study has received funding from European Union’s Horizon 2020 research and innovation programme under grant agreement Nº723596 (Innova MicroSolar) and Nº 657466 (INPATH-TES), from the European Commission Seventh Framework Programme (FP/2007-2013) under grant agreement Nº PIRSES-GA-2013-610692 (INNOSTORAGE). The work is partially funded by the Spanish government ENE2015- 64117-C5-1-R (MINECO/FEDER), ENE2015-64117-C5-3-R (MINECO/FEDER) and (ULLE10-4E-1305). GREA is certified agent TECNIO in the category of technology developers from the Government of Catalonia. The authors would like to thank the Catalan Government for the quality accreditation given to their research group (2014 SGR 123). Alvaro de Gracia would like to thank Ministerio de Economia y Competitividad de España for Grant Juan de la Cierva, FJCI-2014-19940.
Repositori Obert UdL
Publicación Artículo científico (JournalArticle)

Experimental evaluation of a cooling radiant wall coupled to a ground heat exchanger

  • Romaní Picas, Joaquim
  • Pérez Luque, Gabriel
  • Gracia Cuesta, Alvaro de
A building prototype was built in the experimental set-up located in Puigverd de Lleida (Spain) to study the energy performance of a radiant wall with ventilated facade cooled with a ground coupled heat-exchanger. The installed geothermal heat pump operates only as a ground coupled heat exchanger on cooling mode, thus providing free-cooling. In this case, only the circulation pumps consume power. The summer experimental campaign showed the energy savings potential and the peak load shifting ability of the system. On continuous operation and taking as reference a cubicle equipped with a conventional air-to-air heat pump, the radiant wall cooled with the ground coupled heat-exchanger achieved savings up to 54.17% and 82.08% at set-point temperatures of 24 °C and 26 °C, respectively. The thermal storage capacity of the system was studied in night charging test, when the cubicles were pre-cooled during night-time. During the day, the temperature raise caused by heat loads was small and the system kept the temperature inside comfort range despite it only operated overnight. However, the performance was very sensitive to set-point temperature. Free-cooling was limited by the temperatures in the boreholes, showing that with lower set-points the gradient between supply temperature and room temperature was small, and thus it required a higher water flow to achieve the necessary cooling power. Intermittent operation of the system according to different schedules also affected the radiant walls performance as they interacted with the thermal inertia of the system, which could even have a negative impact on energy use., The work partially funded by the Spanish government (ULLE10-4E-1305, ENE2015-64117-C5-1-R(MINECO/FEDER), ENE2015-64117-C5-3-R (MINECO/FEDER)). The authors would like to thank the Catalan Government for the quality accreditation given to their research group (2014 SGR 123) and the city hall of Puigverd de Lleida. This projects has received funding from the European Commission Seventh Framework Programme (FP/2007-2013) under Grant agreement No. PIRSES-GA-2013-610692 (INNOSTORAGE) and from European Union’s Horizon 2020 research and innovation programme under grant agreement No 657466 (INPATH-TES) and from EEA-Grants under grant IDI-20140914. Alvaro de Gracia would like to thank Ministerio de Economia y Competitividad de España for Grant Juan de la Cierva, FJCI-2014-19940.
Repositori Obert UdL
Publicación Contribución de congreso (ConferenceOutput)

Comparative analysis of energy demand and CO2 emissions of residential buildings, Benchmarking of energy demand and CO2 emissions of domestic residential buildings

  • Coma Arpón, Julià
  • Maldonado, José Miguel
  • Gracia Cuesta, Alvaro de
  • Gimbernat, Toni
  • Botargues, Teresa
  • Cabeza, Luisa F.
Rapid expansion of solar thermal energy for increasing energy efficiency of buildings has been adopted in short/medium and long-term energy strategies of EU countries. Within this context, the overall objective of this work is to develop an innovative high performance and cost effective hybrid solar heat and power system. The initial application is to be implemented in individual dwellings and small business residential buildings for onsite electricity and heat generation using solar thermal energy. It is estimated that the proposed technology will deliver 60% of domestic energy requirements and provide 20% reduction in energy costs and greenhouse gas emissions compared to the best existing low carbon energy technologies. The aim of this study consists in performing a comparative analysis of the different building typologies, which can host this technology, and their energy demands for heating and domestic hot water, as well as their CO2 emissions., This study has received funding from Eurepean Union's Horizon 2020 research and innovation programme under grant agreement Nº 723596 (Innova MicroSolar) and Nº 657466 (INPATH-TES). The work is partially funded by the Sapnish government ENE2015-64117-C5-1-R (MINECO/FEDER) and ENE2015-64117-C5-3-R (MINECO/FEDER). GREA is certified agent TECNIO in the cathegory of technology developers from the Government of Catalonia. The authors would like to thanks the Calatan Governmnet for the quality accreditation given to their research group (2014 SGR 123). Alvaro de Gracia would like to thanks Ministerio de Economia y Competitividad de España for Grant Juan de la Cierva, FJCI-2014-19940.
Repositori Obert UdL
Publicación Contribución de congreso (ConferenceOutput)

Benchmarking of energy demand of residential buildings

  • Coma Arpón, Julià
  • Maldonado, José Miguel
  • Gracia Cuesta, Alvaro de
  • Gimbernat, Toni
  • Botargues, Teresa
  • Cabeza, Luisa F.
Solar thermal energy has been adopted in medium and long‐term energy strategies within EU countries for increasing the energy efficiency of buildings. In this context, the overall objective of this project consists in developing an innovative high performance and cost effective hybrid system (solar heat and electrical power). The initial application is to be implemented in residential buildings for on‐site electricity and heat generation using solar thermal energy. The proposed technology is expected to deliver 60% of domestic energy requirements (heating and domestic hot water) and provide 20% reduction in energy costs and greenhouse gas emissions compared to the best existing low carbon energy technologies. A benchmark on the energy demand for the different types of residential buildings in Europe serves as reference scenario to evaluate the potential applicability of the different existing renewable technologies and to establish a comparative framework in terms of quantitative values. Thus, the specific aim of this study consists in performing a state‐of‐the‐art on the different building typologies, which can host this technology, and their energy demands for heating and domestic hot water, as well as their associated CO2 emissions., This study has received funding from European Union’s Horizon 2020 research and innovation programme under grant agreement Nº723596 (Innova MicroSolar) and Nº 657466 (INPATH‐TES). The work is partially funded by the Spanish government ENE2015‐64117‐ C5‐1‐R (MINECO/FEDER) and ENE2015‐64117‐C5‐3‐R (MINECO/FEDER). GREA is certified agent TECNIO in the category of technology developers from the Government of Catalonia. The authors would like to thank the Catalan Government for the quality accreditation given to their research group (2014 SGR 123). Alvaro de Gracia would like to thank Ministerio de Economía y Competitividad de España for Grant Juan de la Cierva, FJCI‐2014‐19940.
Repositori Obert UdL
Publicación Artículo científico (JournalArticle)

Economic and environmental potential for solar assisted central heating plants in the EU residential sector: Contribution to the 2030 climate and energy EU agenda

  • Tulus, Victor
  • Abokersh, Mohamed Hany
  • Cabeza, Luisa F.
  • Vallès Rasquera, J. Manel
  • Jiménez, Laureano
  • Boer, Dieter
Aligning with the ambitious EU 2030 climate and energy package for cutting the greenhouse emissions and replacing conventional heat sources through the presence of renewable energy share inside efficient district heating fields, central solar heating plants coupled with seasonal storage (CSHPSS) can have a viable contribution to this goal. However, the technical performance variation combined with inadequate financial assessment and insufficient environmental impact data associated with the deployment of those innovative district heating systems represents a big challenge for the broad implementation of CSHPSS in Europe. In this context, our paper presents a comprehensive evaluation for the possibility of integrating CSHPSS in the residential sector in various EU member states through the formulation of a multi-objective optimization framework. This framework comprises the life cycle cost analysis for the economic evaluation and the life cycle assessment for the environmental impact estimation simultaneously. The technical performance is also considered by satisfying both the space heating demand and the domestic hot water services. The methodological framework is applied to a residential neighborhood community of 1120 apartments in various EU climate zones with Madrid, Athens, Berlin, and Helsinki acting as a proxy for the Mediterranean continental, Mediterranean, central European, and Nordic climates, respectively. The optimization results regarding the energy performance show that the CSHPSS can achieve a renewable energy fraction above 90% for the investigated climate zones. At the same time, the environmental assessment shows significant improvement when using the CSHPSS in comparison to a natural gas heating system, in those cases the environmental impact is reduced up to 82.1-86.5%. On the other hand, substantial economic improvement is limited, especially in the Mediterranean climate zone (Athens) due to low heating demands and the prices of the non-renewable resources. There the total economic cost of the CSHPSS plants can increase up to 50.8% compared to a natural gas heating system. However, considering the incremental tendency in natural gas prices all over EU nowadays, the study of future plant costs confirms its favorable longterm economic feasibility., The authors would like to acknowledge financial support from the Spanish Ministry of Economy and Competitiveness (ENE2015-64117-C5-1-R (MINECO/FEDER), ENE2015-64117-C5-3-R (MINECO/FEDER) and CTQ2016-77968 (MINECO/FEDER)) and Martí i Franquès COFUND Fellowship program. This project has received funding from the European Union's Horizon 2020 research and innovation programme under the Marie Skłodowska-Curie grant agreement No. 713679. The authors at the University of Lleida would like to thank the Catalan Government for the quality accreditation given to their research group (2017 SGR 1537). GREA is certified agent TECNIO in the category of technology developers from the Government of Catalonia.
Repositori Obert UdL
Publicación Artículo científico (JournalArticle)

Numerical simulation of a PCM packed bed system: A review

  • Gracia Cuesta, Alvaro de
  • Cabeza, Luisa F.
The detailed study of latent packed bed thermal energy storage (TES) system has been a great topic of interest in the literature. Experimental measurements have been conducted to analyze the performance of these systems, however, the complex transient nature of latent TES makes necessary the use of numerical models for detailed study and evaluation of key design parameters, which lead to a numerous scientific contributions in the field. Different and diverse numerical models have been developed, which can be mainly divided into single phase models, Schumman's model, concentric dispersion model, and continuous solid phase model. This paper provides an extensive comprehensive revision of the different numerical models, highlighting the key aspects of each one as well as the main findings in the field. Furthermore, the performance of the different methodologies are discussed and compared. The most important empirical correlations used in the different models in order to take into account physics, such as natural convection inside the spheres or effective thermal conductivity of heat transfer fluid, are also given., The work partially funded by the Spanish Government (ENE2015-64117-C5-1-R (MINECO/FEDER) and ENE2015-64117-C5-3-R (MINECO/FEDER)). The authors would like to thank the Catalan Government for the quality accreditation given to their research group (2014 SGR 123). This project has received funding from the European Commission Seventh Framework Programme (FP/2007-2013) under Grant agreement no. PIRSES-GA-2013-610692 (INNOSTORAGE) and from the European Union's Horizon 2020 research and innovation programme under Grant agreement no. 657466 (INPATH-TES). Alvaro de Gracia would like to thank Ministerio de Economia y Competitividad de España for Grant Juan de la Cierva, FJCI-2014-19940.
Repositori Obert UdL
Publicación Artículo científico (JournalArticle)

Bio-based insulation materials and their hygrothermal performance in a building envelope system (ETICS)

  • Palumbo, Mariana
  • Lacasta Palacio, Ana María
  • Giraldo Forero, María del Pilar
  • Haurie, Laia
  • Correal Mòdol, Eduard
Bio-based insulation materials (such as wood or hemp) are emerging as a promising alternative in building envelope applications, aiming at improving in-use energy efficiency. When compared to common insulation materials (rock and glass wool or petrol-based foams) bio-based materials present the advantage of being renewable, with a low embodied energy and CO2 neutral or negative. Moreover, these materials have a distinct hygrothermal performance, as the sorption/desorption of water vapour in their porous structure, in dynamic equilibrium with their surrounding environment, constantly modifies their hygric and thermal properties while causing energy transfers itself. In this paper, the hygrothermal performance of two different bio-based materials in outdoor conditions is evaluated. The first is an innovative light-weight composite made from corn pith and alginate. The second a commercially available wood insulator. The materials are tested alone and as components of external thermal insulation systems (ETICS) and compared to a conventional polystyrene foam. The results show how the sorption process influence the hygrothermal performance of the materials when the surrounding conditions are modified. When subjected to cyclic changes in temperature and relative humidity, the bio-based materials tested show a lower temperature variation than polystyrene. This is in part due to their lower thermal diffusivity, but also to the water absorption and desorption mechanisms occurring within the materials, which were measured by the change in mass of the materials during the tests. The differences in the thermal performance were more noticeable when the insulation materials were tested alone than when these were tested as a part of an ETIC System., This work was funded by MINECO (Spain) and AEI/FEDER/UE under the projects BIA2014-52688-R, BIA2017-88401-R and ENE2015-64117-C5-3-R. The authors would like to thank the Catalan Government for the quality accreditation given to their research group (2017 SGR 1758). M.P. would like to thank the Brazilian Education Ministry for the financial support received under the PNPD/Capes fellowship. This article has been possible with the support of the Ministerio de Economía y Competitividad (MINECO) and the Universitat Rovira i Virgili (URV) (FJCI-2016-28789).
Repositori Obert UdL
Publicación Artículo científico (JournalArticle)

Control concepts of a radiant wall working as thermal energy storage for peak load shifting of a heat pump coupled to a PV array

  • Romaní Picas, Joaquim
  • Belusko, Martin
  • Alemu, Alemu
  • Cabeza, Luisa F.
  • Gracia Cuesta, Alvaro de
  • Bruno, Frank
Photovoltaic panels (PV) coupled to a heat pump supplying heat to a radiant wall is a system with potential to reduce the imported energy from the grid for heating and cooling of buildings. The radiant wall works as a thermal storage system (TES) allowing storage of the PV output and, thus, peak load shifting. However, the management of these technologies is complex due to the dynamics of the system. This paper presents several control concepts with different purposes such as shifting energy use to off-peak periods, maximizing self-consumption of PV output, and minimization of imported energy from the grid. An experimentally validated numerical model from previous research was used to investigate and compare the different proposed control concepts. Results showed that charging the wall with solar energy resulted in higher overall energy use of the heat pump, while the imported grid energy was significantly reduced, thanks to self-consumption., The authors acknowledge the South Australian Department of State Development who have funded this research through the Premier's Research Industry Fund - International Research Grant Program (IRGP 33). The work was partially funded by the Spanish government (ENE2015-64117-C5-1-R (MINECO/FEDER), ENE2015-64117-C5-3-R (MINECO/FEDER), and ULLE10-4E-1305). GREA is certified agent TECNIO in the category of technology developers from the Government of Catalonia. The authors would like to thank the Catalan Government for the quality accreditation given to their research group (2014 SGR 123) and the city hall of Puigverd de Lleida. This projects has received funding from the European Commission Seventh Framework Programme (FP/2007–2013) under Grant agreement Nº PIRSES-GA-2013-610692 (INNOSTORAGE) and from European Union's Horizon 2020 research and innovation programme under grant agreement Nº 657466 (INPATH-TES). Alvaro de Gracia would like to thank Ministerio de Economia y Competitividad de España for Grant Juan de la Cierva, FJCI-2014-19940.
Repositori Obert UdL
Publicación Contribución de congreso (ConferenceOutput)

Benchmarking of energy demand of domestic and small business buildings

  • Coma Arpón, Julià
  • Maldonado, José Miguel
  • Gracia Cuesta, Alvaro de
  • Gimbernat, Toni
  • Botargues, Teresa
  • Cabeza, Luisa F.
In Europe the building sector represents 41% of the final energy consumption and the 40% of the total GHG emissions of end-use sectors (Directive 2010/31/EU) [1]. Solar energy is one of the forms of renewable energy that has great potential to enable EU the ambition of 12% of heating coming from renewable sources by 2020 [2]. Within this context, the overall objective of the project Innovative Micro Solar Heat and Power System (Innova MicroSolar) is to develop a high performance and cost effective solar heat and power system, which consist in a novel flat Fresnel mirror solar concentrating collector and micro organic Rankine cycle plant combined with advanced phase change materials as thermal storage, all system managed by smart control units. This technology will be initially implemented in individual dwellings and small business residential buildings for on-site electricity and heat generation using solar thermal energy., This study has received funding from European Union’s Horizon 2020 research and innovation programme under grant agreement Nº723596 (Innova MicroSolar) and Nº 657466 (INPATHTES), from the European Commission Seventh Framework Programme (FP/2007-2013) under grant agreement Nº PIRSES-GA-2013-610692 (INNOSTORAGE). The work is partially funded by the Spanish government (ENE2015-64117-C5-1-R (MINECO/FEDER) and ENE2015- 64117-C5-3-R (MINECO/FEDER)). GREA is certified agent TECNIO in the category of technology developers from the Government of Catalonia. The authors would like to thank the Catalan Government for the quality accreditation given to their research group (2014 SGR 123). Alvaro de Gracia would like to thank Ministerio de Economia y Competitividad de España for Grant Juan de la Cierva, FJCI-2014-19940.
Repositori Obert UdL
Publicación Artículo científico (JournalArticle)

Development and experimental validation of a transient 2D numeric model for radiant walls

  • Romaní Picas, Joaquim
  • Cabeza, Luisa F.
  • Gracia Cuesta, Alvaro de
An experimental set-up consisting of a house like cubicle exposed to outdoor weather was used to validate a numerical model of a radiant wall. The 2D transient finite volume model used as inputs the indoor temperature, outdoor temperature, global solar radiation incident on a vertical surface, and temperature and flow of the supply water. The simulation results closely agreed with the temperature profiles and heat fluxes for the three studied orientations (East, South, and West). Furthermore, a parametric study was carried out with the radiant wall model, concluding that pipes spacing between 125 mm and 150 mm and depth between 45 mm and 65 mm minimized the temperature difference on the surface while maximizing the heat flux. Furthermore, a control strategy with shorter activation periods improved the heat transfer efficiency., The work was partially funded by the Spanish government (ENE2015-64117-C5-1-R (MINECO/FEDER), ENE2015-64117-C5-3-R (MINECO/FEDER), and ULLE10-4E-1305). GREA is certified agent TECNIO in the category of technology developers from the Government of Catalonia. The authors would like to thank the Catalan Government for the quality accreditation given to their research group (2014 SGR 123) and the city hall of Puigverd de Lleida. This projects has received funding from the European Commission Seventh Framework Programme (FP/2007–2013) under Grant agreement Nº PIRSES-GA-2013-610692 (INNOSTORAGE) and from European Union's Horizon 2020 research and innovation programme under grant agreement Nº 657466 (INPATH-TES). Alvaro de Gracia would like to thank Ministerio de Economia y Competitividad de España for Grant Juan de la Cierva, FJCI-2014-19940.
Repositori Obert UdL
Publicación Artículo científico (JournalArticle)

Experimental set-up for testing active and passive systems for energy savings in buildings - Lessons learnt

  • Gracia Cuesta, Alvaro de
  • Navarro Farré, Lidia
  • Coma Arpón, Julià
  • Serrano, Susana
  • Romaní Picas, Joaquim
  • Pérez Luque, Gabriel
  • Cabeza, Luisa F.
This paper describes a building prototype experimental set-up used for testing active and passive systems for energy savings, presenting the used methodology, reviewing the main experimental results and identifying limitations. The test facility is located in Puigverd de Lleida (Spain) and has been experimentally evaluating different materials, technologies and systems which might be integrated in building design to provide energy savings for space heating and cooling since 2002. The research fields of passive technologies covered the effect of using different insulating materials, construction systems based on sustainable materials, addition of phase change materials in building envelopes and green infrastructures such as green roofs and walls. On the other hand, the active systems tested were focused in exploiting different available renewable energy source available, such a solar thermal, free-cooling with night air, or geothermal heat, using thermal energy storage systems to shift the heating and cooling loads., The work partially funded by the Spanish Government (ENE2008-06687-C02-01/CON, ENE2011-28269-C03-02, ENE2015-64117-C5-1-R (MINECO/FEDER) and ENE2015-64117-C5-3-R (MINECO/FEDER), and ULLE10-4E-1305). Financiado por el proyectoRTC-2015-3583-5 (INPHASE) del Ministerio de Economía y Competitividad, dentro del Programa Estatal de Investigación, Desarrollo e Innovación Orientada a los Retos de la Sociedad, en el marco del Plan Estatal de Investigación Científica y Técnica y de Innovación 2013–2016, y ha sido cofinanciado con FONDOS FEDER, con el objetivo de promover el desarrollo tecnológico, la innovación y una investigación de calidad GREA is certified agent TECNIO in the category of technology developers from the Government of Catalonia. The authors would like to thank the Catalan Government for the quality accreditation given to their research group (2014 SGR 123) and the city hall of Puigverd de Lleida. The research leading to these results has received funding from the European Union's Seventh Framework Programe (FP7/2007-2013) under grant agreement no. PIRSES-GA-2013-610692 (INNOSTORAGE), from MOPCON Project (EU CRAFT ref. G5ST-CT-2002-50331), from Eccoinnovation Project Rewastee ECO/13/630286 and from European Union's Horizon 2020 Research and Innovation Programme under grant agreement No. 657466 (INPATH-TES) and from EEA-Grants under grant IDI-20140914. This work was supported by the “Corporación Tecnológica de Andalucía” by means of the project “MECLIDE-Soluciones estructurales con materiales especiales para la climatización diferida de edificios” with the collaboration of DETEA. Alvaro de Gracia would like to thank Ministerio de Economia y Competitividad de España for Grant Juan de la Cierva, FJCI-2014-19940. Julià Coma would like to thank the Departament d′Universitats, Recerca i Societat de la Informació de la Generalitat de Catalunya for his research fellowship. Cecilia Castellón, Pablo Arce, Albert Castell, Cristian Solé, Pere Moreno and Lídia Rincón participated in the experimentation in this set-up.
Repositori Obert UdL
Publicación Artículo científico (JournalArticle)

Passive cooling of buildings with phase change materials using whole-building energy simulation tools: A review

  • Saffari Tabalvandani, Mohammad
  • Gracia Cuesta, Alvaro de
  • Ushak, Svetlana
  • Cabeza, Luisa F.
Buildings contribute to climate change by consuming a considerable amount of energy to provide thermal comfort for occupants. Cooling energy demands are expected to increase substantially in the world. On this basis, technologies and techniques providing high energy efficiency in buildings such as passive cooling are highly appreciated. Passive cooling by means of phase change materials (PCM) offers high potential to decrease the cooling energy demand and to improve the indoor comfort condition. However, in order to be appropriately characterized and implemented into the building envelope, the PCM use should be numerically analyzed. Whole-building energy simulation tools can enhance the capability of the engineers and designers to analyze the thermal behavior of PCM-enhanced buildings. In this paper, an extensive review has been made, with regard to whole-building energy simulation for passive cooling, addressing the possibilities of applying different PCM-enhanced components into the building envelope and also the feasibility of PCM passive cooling system under different climate conditions. The application of PCM has not always been as energy beneficial as expected, and actually its effectiveness is highly dependent on the climatic condition, on the PCM melting temperature and on the occupants behavior. Therefore, energy simulation of passive PCM systems is found to be a single-objective or multi-objective optimization problem which requires appropriate mathematical models for energy and comfort assessment which should be further investigated. Moreover, further research is required to analyze the influence of natural night ventilation on the cooling performance of PCM., The work is partially funded by the Spanish government (ENE2015-64117-C5-1-R (MINECO/FEDER) and ENE2015-64117-C5-3-R (MINEDO/FEDER)). The authors would like to thank the Catalan Government for the quality accreditation g iven to their research group GREA (2014 SGR 123). This project has received funding from the European Commission Seventh Framework Program (FP/2007-2013) under Grant agreement Nº PIRSES-GA-2013-610692 (INNOSTORAGE) and from the European Union’s Horizon 2020 research and innovation program under grant ag reement No 657466 (INPATH-TES). Alvaro de Gracia would like to thank Ministerio de Economia y Competitividad de España for Grant Juan de la Cierva, FJCI-2014-19940.
Repositori Obert UdL
Publicación Artículo científico (JournalArticle)

Supercritical CO2 as heat transfer fluid: A review

  • Cabeza, Luisa F.
  • Gracia Cuesta, Alvaro de
  • Fernández Renna, Ana Inés
  • Farid, Mohammed M.
This paper presents a comprehensive review of all correlations and experimental studies available in the literature to determine the heat transfer coefficient of supercritical CO2 flowing in heat exchangers. The different applications in which it is used are also reviewed and discussed. The correlations obtained from extensive experimental measurements are presented for different geometries (horizontal, vertical and inclined tubes, closed-loop circular pipes, and mini-channels) and dimensions. The review shows that there is a lack of a unique universal correlation for each geometry, suggesting the need for more work in this area., The work partially funded by the Spanish government (ENE2015-64117-C5-1-R (MINECO/FEDER) and ENE2015-64117-C5-3-R (MINECO/FEDER)). The authors would like to thank the Catalan Government for the quality accreditation given to their research group (2014 SGR 123). This project has received funding from the European Commission Seventh Framework Programme (FP/2007-2013) under Grant agreement N°PIRSES-GA-2013-610692 (INNOSTORAGE) and from the European Union’s Horizon 2020 research and innovation programme under grant agreement No 657466 (INPATH-TES), and the funds received by the Royal Society of New Zealand. Alvaro de Gracia would like to thank Ministerio de Economia y Competitividad de España for Grant Juan de la Cierva, FJCI-2014-19940.
Repositori Obert UdL
Publicación Contribución de congreso (ConferenceOutput)

Optimization of coupled building roof solar reflectance and thermal insulation level for annual energy saving under different climate zones

  • Piselli, Cristina
  • Pisello, Anna Laura
  • Gracia Cuesta, Alvaro de
  • Saffari Tabalvandani, Mohammad
  • Cotana, Franco
  • Cabeza, Luisa F.
The aim of this work is to assess building energy performance optimization potential of cool roof solutions in different climate conditions worldwide through dynamic thermal-energy simulation and optimization analysis. Moreover, given the dependence of roof performance on insulation level, the influence of roof insulation variation on optimum roof solar reflectance is evaluated. Therefore, the multi-dimensional optimization of combined building roof solar reflectance capability and thermal insulation level is carried out to minimize annual energy consumption for air-conditioning of standard ASHRAE building model for small offices, in each considered climate zone. Findings of this research highlight how the classic approach of super-insulated buildings for energy saving needs to be reframed for the office case, by integrating other passive solutions for truly environmentally friendly and comfortable buildings., The research leading to these results has received funding from the European Union's Horizon 2020 research and innovation programme under grant agreement N°657466 (INPATH-TES). The work is partially funded by the Spanish government (ENE2015-64117-C5-1-R (MINECO/FEDER) and ENE2015-64117-C5-3-R (MINECO/FEDER)). The authors from the University of Lleida would like to thank the Catalan Government for the quality accreditation given to their research group (2014 SGR 123). Anna Laura Pisello’s acknowledgments are due to the UNESCO Chair “Water Resources Management and Culture”, for supporting her research. Alvaro de Gracia would like to thank Ministerio de Economia y Competitividad de España for Grant Juan de la Cierva, FJCI-2014-19940.
Repositori Obert UdL
Publicación Artículo científico (JournalArticle)

Vertical greenery systems for energy savings in buildings: a comparative study between green walls and green facades

  • Coma Arpón, Julià
  • Pérez Luque, Gabriel
  • Gracia Cuesta, Alvaro de
  • Burés, Silvia
  • Urrestarazu, Miguel
  • Cabeza, Luisa F.
During the last decade, vertical greenery systems are increasing their presence in building designs, providing several urban ecosystem services. One of them is the potential to provide energy savings in buildings, which develops an important role, however, data about its performance during winter periods is still scarce. Therefore, the main objective of this paper is to compare at real scale the thermal performance of two different vertical greenery systems implemented in experimental houses-like cubicles for both cooling and heating periods. A double-skin green facade has been installed in the first cubicle that uses deciduous creeper plants, while the second one is designed with green walls made with evergreen species. Finally, a third identical cubicle without any green coverage is used as reference. Two different types of experiments have been carried out to test the performance of the house like-cubicles. One consists of controlling the internal ambient temperature providing heating or cooling to maintain the desired comfort conditions. On the other hand, to study the thermal response of the construction system, the heating, ventilation and air conditioning system was disconnected and the cubicles were tested under free floating condition. First results showed a high potential for energy savings during cooling season for green wall (58.9%) and double-skin green facade (33.8%) in comparison to the reference system. On the other hand, for heating periods no extra energy consumption was observed for evergreen system., The work partially funded by the Spanish government (ENE2015-64117-C5-1-R (MINECO/FEDER), ENE2015-64117-C5-3-R (MINECO/FEDER) and ULLE10-4E-1305) in collaboration with the company Buresinnova S.A (C/Saragossa, 95 Entsol 3a, 08006 BARCELONA). The authors would like to thank the Catalan Government for the quality accreditation given to their research group (2014 SGR 123) and to the city hall of Puigverd de Lleida. This study has received funding from the European Commission Seventh Framework Programme (FP/2007–2013) under Grant agreement Nº PIRSES-GA-2013-610692 (INNOSTORAGE) and from European Union's Horizon 2020 research and innovation programme under grant agreement Nº 657466 (INPATH-TES). Alvaro de Gracia would like to thank Ministerio de Economia y Competitividad de España for Grant Juan de la Cierva, FJCI-2014-19940. Julià Coma would like to thank the Departament d'Universitats, Recerca i Societat de la Informació de la Generalitat de Catalunya for his research fellowship.
Repositori Obert UdL
Publicación Artículo científico (JournalArticle)

Study of the Thermal Properties and the Fire Performance of Flame Retardant-Organic PCM in Bulk Form

  • Palacios, Anabel
  • Gracia Cuesta, Alvaro de
  • Haurie, Laia
  • Cabeza, Luisa F.
  • Fernández Renna, Ana Inés
  • Barreneche Güerisoli, Camila
The implementation of organic phase change materials (PCMs) in several applications such as heating and cooling or building comfort is an important target in thermal energy storage (TES). However, one of the major drawbacks of organic PCMs implementation is flammability. The addition of flame retardants to PCMs or shape-stabilized PCMs is one of the approaches to address this problem and improve their final deployment in the building material sector. In this study, the most common organic PCM, Paraffin RT-21, and fatty acids mixtures of capric acid (CA), myristic acid (MA), and palmitic acid (PA) in bulk, were tested to improve their fire reaction. Several flame retardants, such as ammonium phosphate, melamine phosphate, hydromagnesite, magnesium hydroxide, and aluminum hydroxide, were tested. The properties of the improved PCM with flame retardants were characterized by thermogravimetric analyses (TGA), the dripping test, and differential scanning calorimetry (DSC). The results for the dripping test show that fire retardancy was considerably enhanced by the addition of hydromagnesite (50 wt %) and magnesium hydroxide (50 wt %) in fatty acids mixtures. This will help the final implementation of these enhanced PCMs in building sector. The influence of the addition of flame retardants on the melting enthalpy and temperatures of PCMs has been evaluated., The research leading to these results has received funding from the European Commission Seventh Framework Programme (FP/2007-2013) under grant agreement number PIRSES-GA-2013-610692 (INNOSTORAGE) and from the European Union’s Horizon 2020 research and innovation program under grant agreement No. 657466 (INPATH-TES). The authors would like to thank the Catalan Government for the quality accreditation given to their research groups GREA (2014 SGR 123), DIOPMA (2014 SGR 1543) and GICITED (2014 SGR 1298), and also the MINECO for the project BIA2014-52688-R, ENE2015-64117-C5-1-R, ENE2015-64117-C5-2-R, and ENE2015-64117-C5-3-R. Alvaro de Gracia and Camila Barreneche would like to thank Ministerio de Economia y Competitividad de España for Grant Juan de la Cierva, FJCI-2014-19940 and FJCI-2014-22886, respectively.
Repositori Obert UdL
Publicación Artículo científico (JournalArticle)

Influence of the storage period between charge and discharge in a latent heat thermal energy storage system working under partial load operating conditions

  • Gasia, Jaume
  • Gracia Cuesta, Alvaro de
  • Zsembinszki, Gabriel
  • Cabeza, Luisa F.
The supply intermittency of energy sources like solar energy or industrial waste heat should be properly addressed when studying latent heat thermal energy storage (TES) systems, since it might cause an incomplete melting/solidification of phase change materials (PCM). In the present paper, and experimental study was performed to analyse the storage period (also known as stand-by period) in a latent heat TES system working under partial load operating conditions and the effect of its duration on the subsequent discharging process. In the experimental set-up, 99.5 kg of high density polyethylene (HDPE) was used as PCM in a 0.154m3 storage tank based on the shell-and-tube heat exchanger concept. Four different percentages of charge were evaluated: 58%, 73%, 83% (partial charge), and 97% (full charge). Each charging level was followed by three different periods of storage: 25 min, 60 min, and 120 min. The fact of working at different levels of charge caused that in some regions of the TES system the PCM was not completely melted. Thus, at the end of the charging process different levels of thermal homogenisation were observed. However, during the storage period, the PCM temperature showed a tendency to homogenisation, which was influenced by the energy distribution within the PCM, the heat losses, and the duration of the storage period. Focusing on the discharging period, it was observed that the duration of the storage period slightly affected the temperature and heat transfer profiles, causing the main differences of performance during the first 30 min of process., This work was partially funded by the Ministerio de Economía y Competitividad de España (ENE2015-64117-C5-1-R (MINECO/FEDER) and ENE2015-64117-C5-3-R (MINECO/FEDER)). The authors would like to thank the Catalan Government for the quality accreditation given to their research group (2017 SGR 1537). GREA is certified agent TECNIO in the category of technology developers from the Government of Catalonia. Jaume Gasia would like to thank the Departament d'Universitats, Recerca i Societat de la Informació de la Generalitat de Catalunya for his research fellowship (2018 FI_B2 00100).
Repositori Obert UdL
Publicación Contribución de congreso (ConferenceOutput)

Ensayos preliminares de una microturbina de ciclo orgánico de Rankine alimentada por un campo solar de concentración tipo Fresnel lineala

  • Maldonado, José Miguel
  • Gracia Cuesta, Alvaro de
  • Mahkamov, Khamid
  • Costa, Carolina
  • Kenisarin, Murat
  • Pili, Piero
  • Manca, Roberto
  • Leroux, Arthur
  • Mintsa, André Charles
  • Bartolini, Carlo M.
  • Pirro, Matteo
  • Lynn, Kevin
  • Mullen, David
  • Halimic, Elvedin
  • Cabeza, Luisa F.
El propósito de esta investigación es evaluar la influencia del tipo de cemento en sí mismo a altas temperaturas, desestimando el resto de componentes del hormigón. El presente estudio se centra en la comparación del tratamiento de dos tipos de cemento, a saber, cemento Portland (OPC) y cemento aluminoso (cemento de aluminato de calcio, CAC). Se determina las características físicas y resistencias mecánicas a compresión. A pesar de la resistencia a altas temperaturas del CAC y la baja relación agua/cemento (a/c) utilizada, este tipo de pasta de cemento requiere de un curado inminente. Si tal hidratación no se ejecuta en sus primeras edades, la pasta de CAC muestra un comportamiento similar a la pasta de OPC, desaprovechando tanto sus características refractarias como sus altas resistencias mecánicas iniciales., The purpose of this investigation is to evaluate the influence of cement type itself, at high temperatures, disregarding the rest of the concrete components. The present study focuses on the treatment comparison of two cement types, known as, ordinary Portland cement (OPC) and calcium aluminate cement (CAC). The physical characteristics and compressive strength are determined. Despite the resistance to high temperatures of the CAC and the low water/cement (w/c) ratio used, this type of cement paste requires an imminent cure at certain temperature. If such hydration is not carried out in its early ages, the CAC paste shows a behavior similar to OPC paste, wasting both its refractory characteristics and its high initial mechanical resistances., Este trabajo ha sido parcialmente financiado el programa de Investigación y Desarrollo H2020 de la Unión Europea, a través del Grant Agreement 723596, cuyo nombre de referencia es Innova MicroSolar. Este trabajo ha sido cofinanciado por el Ministerio de Economía y Competitividad de España (ENE2015-64117-C5-1-R (MINECO/FEDER) y ENE2015-64117-C5-3-R (MINECO/FEDER)). Los autores quieren agradecer al Gobierno de Cataluña por la acreditación de calidad otorgada a su grupo de investigación (2017 SGR 1537). GREA es un agente TECNIO certificado en la categoría de desarrolladores tecnológicos por el Gobierno de Cataluña. José Miguel Maldonado agradece al Gobierno de España la concesión de la ayuda para contratos predoctorales para la formación de doctores (BES-2016-076554). Alvaro de Gracia agradece los fondos recibidos del programa de Investigación y Desarrollo H2020 de la Unión Europea, a través del Marie Sklodowska-Curie Grant Agreement No 712949.
Repositori Obert UdL
Publicación Artículo científico (JournalArticle)

New formulation and characterization of enhanced bulk-organic phase change materials

  • Palacios, Anabel
  • Gracia Cuesta, Alvaro de
  • Cabeza, Luisa F.
  • Julià Bolivar, José Enrique
  • Fernández Renna, Ana Inés
  • Barreneche Güerisoli, Camila
The main drawbacks faced by researchers to successfully implement organic-PCM as materials to improve the thermal performance of building systems are their low thermal conductivity, their high flammability, and their low thermal cycling stability. T In the present work, authors present a new enhanced PCM formulations aimed to solve the stated disadvantages in organic bulk-PCM. The new enhanced PCM were prepared by adding high thermal conductivity particles and two kinds of flame retardants into organic PCM (paraffin and fatty acid eutectic mixtures). In the first stage, the effective thermal conductivity of organic-PCM was increased by using two different methods: directly dispersion of powder graphite (PG) bulk-PCM and vacuum impregnation of PCM into expanded graphite (EG). In the second stage, the fire reaction behaviour of the thermal conductivity enhanced PCM formulations was improved by adding two kind of flame retardant: magnesium hydroxide and ammonium phosphate (APP).. Their fire reaction behaviour, thermal conductivity and thermophysical properties were measured by adapting the dripping test (UNE 23727-90), the hot-wire method and Differential Scanning Calorimetry (DSC), respectively. The enhanced PCM composites show a self-extinguished behaviour in terms of fire performance mechanism. The EG working with endothermic and phosphates flame retardants improve the fire performance of PCM by acting as a synergic system and the thermal conductivity is increased. However, their thermal storage capacity is significant decreased due to the large amount of flame retardant added (up to 40%). The thermal reliability was also tested, the enhanced PCM composites were stable up to 1000 thermal cycles., The research leading to these results has received funding from the European Commission Seventh Framework Programme (FP/2007-2013) under grant agreement n° PIRSES-GA-2013-610692 (INNOSTORAGE) and from the European Union's Horizon 2020 research and innovation program under grant agreement No 657466 (INPATH-TES). The authors would like to thank the Catalan Government for the quality accreditation given to their research groups GREA (2014 SGR 123), DIOPMA (2014 SGR 1543) and GICITED (2014 SGR 1298). The work partially funded by the Spanish government (ENE2015-64117-C5-1-R (MINECO/FEDER), ENE2015-64117-C5-2-R(MINECO/FEDER), and ENE2015-64117-C5-3-R(MINECO/FEDER)). Dr. Alvaro de Gracia and Dr. Camila Barreneche would like to thank Ministerio de Economia y Competitividad de España for Grant Juan de la Cierva, FJCI-2014-19940 and FJCI-2014-22886, respectively.
Repositori Obert UdL
Publicación Artículo científico (JournalArticle)

Multi-objective optimisation of bio-based thermal insulation materials in building envelopes considering condensation risk

  • Torres Rivas, Alba
  • Palumbo, Mariana
  • Haddad, Assed Naked
  • Cabeza, Luisa F.
  • Jiménez, Laureano
  • Boer, Dieter
The reduction in energy demand for heating and cooling with insulation materials increases the material related environmental impact. Thus, implementing low embodied energy materials may equilibrate this trade-off. Actual trends in passive house postulate bio-based materials as an alternative to conventional ones. Despite that, the implementation of those insulators should be carried out with a deeper analysis due to their hygroscopic properties. The moisture transfer, the associated condensation risk and the energy consumption for seven biobased materials and polyurethane for a building-like cubicle are analysed. The performance is evaluated combining a software application to model the cubicle (EnergyPlus) and a tool to optimize its performance (jEPlus). The novelty of this optimization approach is to include and evaluate the effects of moisture in these insulation materials, taking into account the mass transfer through the different layers and the evaporation of the different materials. This methodology helps optimise the insulation type and thickness verifying the condensation risk, preventing the deterioration of the materials. The total cost of the different solutions is quantified, and the environmental impact is determined using the life cycle assessment methodology. The effect of climate conditions and the envelope configuration, as well as the risk of condensation, are quantified. The results show that cost and environmental impact can be reduced if bio-based materials are used instead of conventional ones, especially in semiarid climates. Condensation risk occurs for large thicknesses and in humid climates. In our case studies, hemp offered the most balanced solution., The authors would like to acknowledge financial support from the Spanish Government (CTQ2016-77968-C3-1-P, ENE2015-64117-C5-1-R, ENE2015-64117-C5-3-R, MINECO/FEDER, UE). The research leading to these results has received funding from the European Commission Seventh Framework Programme under grant agreement no. PIRSES-GA-2013-610692 (INNOSTORAGE). This project has received funding the European Union's Horizon 2020 Research and Innovation Program under grant agreement No 657466 (INPATH-TES). This article has been possible with the support of the Ministerio de Economía y Competitividad (MINECO) and the Universitat Rovira i Virgili (URV) (FJCI-2016-28789). Authors would like to acknowledge the Brazilian Government for their support by the CNPq (National Council for Scientific and Technological Development). M.P. would like to thank the Brazilian Education Ministry for the financial support received under the PNPD/Capes fellowship. L.F.C. would like to thank the Catalan Government for the quality accreditation given to her research group GREA (2014 SGR 123).
DIGITAL.CSIC. Repositorio Institucional del CSIC
Publicación Contribución de congreso (ConferenceOutput)

Micro-encapsulated PCM in concrete matrix after a decade of the building construction

  • Olivieri, Lorenzo
  • Tenorio Ríos, José Antonio
Trabajo presentado a la 14th International Energy Storage Conference (EnerSTOCK), celebrada en la Universidad de Çukurova (Turquía) del 25 al 28 de abril de 2018., The reduction of the energy consumed in the building sector is no more a recommendation, but a duty of our society. Thermal energy storage (TES) implementation into buildings envelope has been highlighted as a promising technology to reduce the energy demand in buildings. Last decade, many literature have been dealing with the effect of the inclusion of latent heat storage materials in construction materials to provide higher thermal inertia. Several studies focused on the evaluation of the thermal properties, density, or porosity of these new materials. However, few of them focused on the long stability properties of the materials with embedded PCM when included in a building, since the lifetime of a building last around 50 years. In this study, an evaluation of a house-like cubicle of concrete with micro-encapsulated PCM after a decade of its construction is done. The results of this study were compared to the tests done in 2005 concluding that the thermal performance of this cubicle presented no degradation in the PCM effect., The work partially funded by the Spanish government (ENE2015-64117-C5-1-R (MINECO/FEDER), ENE2015-64117-C5-3-R (MINECO/FEDER), ULLE10-4E-1305, and ENE2005-08256-C02-01). The authors would like to thank the Catalan Government for the quality accreditation given to their research group (2014 SGR 123) and the city hall of Puigverd de Lleida. GREA is certified agent TECNIO in the category of technology developers from the Government of Catalonia. This project has received funding from the European Union’s Horizon 2020 research and innovation programme under grant agreement No 657466 (INPATH-TES). Financiado por el proyecto RTC-2015-3583-5 (INPHASE) del Ministerio de Economía y Competitividad, dentro del Programa Estatal de Investigación, Desarrollo e Innovación Orientada a los Retos de la Sociedad, en el marco del Plan Estatal de Investigación Científica y Técnica y de Innovación 2013-2016, y ha sido cofinanciado con FONDOS FEDER, con el objetivo de promover el desarrollo tecnológico, la innovación y una investigación de calidad.
Recercat. Dipósit de la Recerca de Catalunya
Publicación Artículo científico (JournalArticle)

Development and experimental validation of a transient 2D numeric model for radiant walls

  • Romaní Picas, Joaquim
  • Cabeza, Luisa F.
  • Gracia Cuesta, Alvaro de
An experimental set-up consisting of a house like cubicle exposed to outdoor weather was used to validate a numerical model of a radiant wall. The 2D transient finite volume model used as inputs the indoor temperature, outdoor temperature, global solar radiation incident on a vertical surface, and temperature and flow of the supply water. The simulation results closely agreed with the temperature profiles and heat fluxes for the three studied orientations (East, South, and West). Furthermore, a parametric study was carried out with the radiant wall model, concluding that pipes spacing between 125 mm and 150 mm and depth between 45 mm and 65 mm minimized the temperature difference on the surface while maximizing the heat flux. Furthermore, a control strategy with shorter activation periods improved the heat transfer efficiency., The work was partially funded by the Spanish government (ENE2015-64117-C5-1-R (MINECO/FEDER), ENE2015-64117-C5-3-R (MINECO/FEDER), and ULLE10-4E-1305). GREA is certified agent TECNIO in the category of technology developers from the Government of Catalonia. The authors would like to thank the Catalan Government for the quality accreditation given to their research group (2014 SGR 123) and the city hall of Puigverd de Lleida. This projects has received funding from the European Commission Seventh Framework Programme (FP/2007–2013) under Grant agreement Nº PIRSES-GA-2013-610692 (INNOSTORAGE) and from European Union's Horizon 2020 research and innovation programme under grant agreement Nº 657466 (INPATH-TES). Alvaro de Gracia would like to thank Ministerio de Economia y Competitividad de España for Grant Juan de la Cierva, FJCI-2014-19940.
Recercat. Dipósit de la Recerca de Catalunya
Publicación Contribución de congreso (ConferenceOutput)

Benchmarking of energy demand of residential buildings

  • Coma Arpón, Julià
  • Maldonado, José Miguel
  • Gracia Cuesta, Alvaro de
  • Gimbernat, Toni
  • Botargues, Teresa
  • Cabeza, Luisa F.
Solar thermal energy has been adopted in medium and long‐term energy strategies within EU countries for increasing the energy efficiency of buildings. In this context, the overall objective of this project consists in developing an innovative high performance and cost effective hybrid system (solar heat and electrical power). The initial application is to be implemented in residential buildings for on‐site electricity and heat generation using solar thermal energy. The proposed technology is expected to deliver 60% of domestic energy requirements (heating and domestic hot water) and provide 20% reduction in energy costs and greenhouse gas emissions compared to the best existing low carbon energy technologies. A benchmark on the energy demand for the different types of residential buildings in Europe serves as reference scenario to evaluate the potential applicability of the different existing renewable technologies and to establish a comparative framework in terms of quantitative values. Thus, the specific aim of this study consists in performing a state‐of‐the‐art on the different building typologies, which can host this technology, and their energy demands for heating and domestic hot water, as well as their associated CO2 emissions., This study has received funding from European Union’s Horizon 2020 research and innovation programme under grant agreement Nº723596 (Innova MicroSolar) and Nº 657466 (INPATH‐TES). The work is partially funded by the Spanish government ENE2015‐64117‐ C5‐1‐R (MINECO/FEDER) and ENE2015‐64117‐C5‐3‐R (MINECO/FEDER). GREA is certified agent TECNIO in the category of technology developers from the Government of Catalonia. The authors would like to thank the Catalan Government for the quality accreditation given to their research group (2014 SGR 123). Alvaro de Gracia would like to thank Ministerio de Economía y Competitividad de España for Grant Juan de la Cierva, FJCI‐2014‐19940.
Recercat. Dipósit de la Recerca de Catalunya
Publicación Artículo científico (JournalArticle)

Bio-based insulation materials and their hygrothermal performance in a building envelope system (ETICS)

  • Palumbo, Mariana
  • Lacasta Palacio, Ana María
  • Giraldo Forero, María del Pilar
  • Haurie, Laia
  • Correal Mòdol, Eduard
Bio-based insulation materials (such as wood or hemp) are emerging as a promising alternative in building envelope applications, aiming at improving in-use energy efficiency. When compared to common insulation materials (rock and glass wool or petrol-based foams) bio-based materials present the advantage of being renewable, with a low embodied energy and CO2 neutral or negative. Moreover, these materials have a distinct hygrothermal performance, as the sorption/desorption of water vapour in their porous structure, in dynamic equilibrium with their surrounding environment, constantly modifies their hygric and thermal properties while causing energy transfers itself. In this paper, the hygrothermal performance of two different bio-based materials in outdoor conditions is evaluated. The first is an innovative light-weight composite made from corn pith and alginate. The second a commercially available wood insulator. The materials are tested alone and as components of external thermal insulation systems (ETICS) and compared to a conventional polystyrene foam. The results show how the sorption process influence the hygrothermal performance of the materials when the surrounding conditions are modified. When subjected to cyclic changes in temperature and relative humidity, the bio-based materials tested show a lower temperature variation than polystyrene. This is in part due to their lower thermal diffusivity, but also to the water absorption and desorption mechanisms occurring within the materials, which were measured by the change in mass of the materials during the tests. The differences in the thermal performance were more noticeable when the insulation materials were tested alone than when these were tested as a part of an ETIC System., This work was funded by MINECO (Spain) and AEI/FEDER/UE under the projects BIA2014-52688-R, BIA2017-88401-R and ENE2015-64117-C5-3-R. The authors would like to thank the Catalan Government for the quality accreditation given to their research group (2017 SGR 1758). M.P. would like to thank the Brazilian Education Ministry for the financial support received under the PNPD/Capes fellowship. This article has been possible with the support of the Ministerio de Economía y Competitividad (MINECO) and the Universitat Rovira i Virgili (URV) (FJCI-2016-28789).
Recercat. Dipósit de la Recerca de Catalunya
Publicación Artículo científico (JournalArticle)

Phase Change Material Selection for Thermal Energy Storage at High Temperature Range between 210 ºC and 270 ºC

  • Maldonado, José Miguel
  • Fullana Puig, Margalida
  • Martín, Marc
  • Solé, Aran
  • Fernández, Ángel G.
  • Gracia Cuesta, Alvaro de
  • Cabeza, Luisa F.
The improvement of thermal energy storage systems implemented in solar technologies increases not only their performance but also their dispatchability and competitiveness in the energy market. Latent heat thermal energy storage systems are one of those storing methods. Therefore, the need of finding the best materials for each application becomes an appealing research subject. The main goal of this paper is to find suitable and economically viable materials able to work as phase change material (PCM) within the temperature range of 210-270 ºC and endure daily loading and unloading processes in a system with Fresnel collector and an organic Rankine cycle (ORC). Twenty-six materials have been tested and characterized in terms of their thermophysical conditions, thermal and cycling stability, and health hazard. Two materials out of the 26 candidates achieved the last stage of the selection process. However, one of the two finalists would require an inert working atmosphere, which would highly increase the cost for the real scale application. This leads to a unique suitable material, solar salt (40 wt % KNO3/60 wt % NaNO3)., This work was partially funded by the European Union’s Horizon 2020 Research & Innovation Programme under Grant Agreement 723596 with reference name Innova MicroSolar. This work was partially funded by the Ministerio de Economía y Competitividad de España (ENE2015-64117-C5-1-R (MINECO/FEDER) and ENE2015-64117-C5-3-R (MINECO/FEDER)). The authors would like to thank the Catalan Government for the quality accreditation given to their research group (2017 SGR 1537). GREA is certified agent TECNIO in the category of technology developers from the Government of Catalonia. José Miguel Maldonado would like to thank the Spanish Government for his research fellowship (BES-2016-076554). Aran Solé would like to thank Ministerio de Economía y Competitividad de España for Grant Juan de la Cierva, FJCI-2015-25741. Alvaro de Gracia has received funding from the European Union’s Horizon 2020 research and innovation programme under the Marie Sklodowska-Curie grant agreement No. 712949. Angel G. Fernández would like to acknowledge the financial support provided by GIZ “Programa de pasantía en el extranjero en tecnologías de concentración solar para investigadores” and CONICYT/FONDAP 15110019 “Solar Energy Research Center” SERC-Chile.
Recercat. Dipósit de la Recerca de Catalunya
Publicación Artículo científico (JournalArticle)

Study of the Thermal Properties and the Fire Performance of Flame Retardant-Organic PCM in Bulk Form

  • Palacios, Anabel
  • Gracia Cuesta, Alvaro de
  • Haurie, Laia
  • Cabeza, Luisa F.
  • Fernández Renna, Ana Inés
  • Barreneche Güerisoli, Camila
The implementation of organic phase change materials (PCMs) in several applications such as heating and cooling or building comfort is an important target in thermal energy storage (TES). However, one of the major drawbacks of organic PCMs implementation is flammability. The addition of flame retardants to PCMs or shape-stabilized PCMs is one of the approaches to address this problem and improve their final deployment in the building material sector. In this study, the most common organic PCM, Paraffin RT-21, and fatty acids mixtures of capric acid (CA), myristic acid (MA), and palmitic acid (PA) in bulk, were tested to improve their fire reaction. Several flame retardants, such as ammonium phosphate, melamine phosphate, hydromagnesite, magnesium hydroxide, and aluminum hydroxide, were tested. The properties of the improved PCM with flame retardants were characterized by thermogravimetric analyses (TGA), the dripping test, and differential scanning calorimetry (DSC). The results for the dripping test show that fire retardancy was considerably enhanced by the addition of hydromagnesite (50 wt %) and magnesium hydroxide (50 wt %) in fatty acids mixtures. This will help the final implementation of these enhanced PCMs in building sector. The influence of the addition of flame retardants on the melting enthalpy and temperatures of PCMs has been evaluated., The research leading to these results has received funding from the European Commission Seventh Framework Programme (FP/2007-2013) under grant agreement number PIRSES-GA-2013-610692 (INNOSTORAGE) and from the European Union’s Horizon 2020 research and innovation program under grant agreement No. 657466 (INPATH-TES). The authors would like to thank the Catalan Government for the quality accreditation given to their research groups GREA (2014 SGR 123), DIOPMA (2014 SGR 1543) and GICITED (2014 SGR 1298), and also the MINECO for the project BIA2014-52688-R, ENE2015-64117-C5-1-R, ENE2015-64117-C5-2-R, and ENE2015-64117-C5-3-R. Alvaro de Gracia and Camila Barreneche would like to thank Ministerio de Economia y Competitividad de España for Grant Juan de la Cierva, FJCI-2014-19940 and FJCI-2014-22886, respectively.
Recercat. Dipósit de la Recerca de Catalunya
Publicación Artículo científico (JournalArticle)

Use of partial load operating conditions for latent thermal energy storage management

  • Gasia, Jaume
  • Gracia Cuesta, Alvaro de
  • Peiró Bell-lloch, Gerard
  • Arena, Simone
  • Cau, Giorgio
  • Cabeza, Luisa F.
A proper management of thermal energy storage (TES) charging and discharging processes allows the final users to optimize the performance of TES systems. In this paper, an experimental research is carried out to study how the percentage of charge in a latent heat TES system (partial load operating conditions) influences the discharge process. Several charging and discharging processes were performed at a constant heat transfer fluid (HTF) mass flow rate of 0.5 kg/s and temperature of 155 °C and 105 °C, respectively. High density polyethylene (HDPE) with a total mass of 99.5 kg was used as phase change material (PCM) in a 0.154m3 storage tank based on the shelland-tube heat exchanger concept. Five different percentages of charge have been studied: 58 %, 73 %, 83 %, 92 %, and 97 % (baseline test). Results showed that by modifying the percentage of charge, the time required for the charging process was reduced between 97.2% and 68.8% in comparison to the baseline case. However, the energy accumulated was only reduced a maximum of 35.1% and a minimum of 5.2%, while the heat transfer rates during the first 60 min of discharge were reduced a maximum of 45.8% and a minimum of 6%. Therefore, partially charging the TES system not lower than 85% of its maximum energy capacity becomes a good option if the final application accepts a maximum decrease of discharging heat transfer rates of 10% if compared to the fully charged system., The work was partially funded by the Spanish government (ENE2015-64117-C5-1-R (MINECO/FEDER), ENE2015-64117-C5-3-R (MINECO/FEDER), and ULLE10-4E-1305). The authors would like to thank the Catalan Government for the quality accreditation given to their research group (2014 SGR 123). GREA is certified agent TECNIO in the category of technology developers from the Government of Catalonia. This project has received funding from the European Commission Seventh Framework Programme (FP/2007-2013) under Grant agreement No. PIRSES-GA-2013-610692 (INNOSTORAGE) and from the European Union’s Horizon 2020 research and innovation programme under grant agreement No. 657466 (INPATH-TES). Jaume Gasia would like to thank the Departament d'Universitats, Recerca i Societat de la Informació de la Generalitat de Catalunya for his research fellowship (2017 FI_B1 00092). Alvaro de Gracia would like to thank Ministerio de Economia y Competitividad de España for Grant Juan de la Cierva, FJCI-2014-19940. Simone Arena would like to thank the Department of Mechanical, Chemical and Materials Engineering of the University of Cagliari for funding his research grant.
Recercat. Dipósit de la Recerca de Catalunya
Publicación Artículo científico (JournalArticle)

Optimized demand side management (DSM) of peak electricity demand by coupling low temperature thermal energy storage (TES) and solar PV

  • Saffari Tabalvandani, Mohammad
  • Gracia Cuesta, Alvaro de
  • Fernàndez Camon, César
  • Belusko, Martin
  • Boer, Dieter
  • Cabeza, Luisa F.
Cooling in the industry sector contributes significantly to the peak demand placed on an electrical utility grid. New electricity tariff structures include high charges for electricity consumption in peak hours which leads to elevated annual electricity costs for high-demanding consumers. Demand side management (DSM) is a promising solution to increase the energy efficiency among customers by reducing their electricity peak demand and consumption. In recent years, researchers have shown an increased interest in utilizing DSM techniques with thermal energy storage (TES) and solar PV technologies for peak demand reduction in industrial and commercial sectors. The main objective of the present study is to address the potential for applying optimization-based time-of-use DSM in the industry sector by using cold thermal energy storage and off-grid solar PV to decrease and shift peak electricity demands and to reduce the annual electricity consumption costs. The results show that when cold thermal energy storage and solar PV are coupled together higher annual electricity cost savings can be achieved compared to using these two technologies independently. Additionally, considerable reductions can be seen in electricity power demands in different tariff periods by coupling thermal energy storage with off-grid solar PV., The work partially funded by the Spanish government (ENE2015-64117-C5-1-R (MINECO/FEDER), ENE2015-64117-C5-3-R (MINECO/FEDER), and TIN2015-71799-C2-2-P). The authors would like to thank the Catalan Government for the quality accreditation given to their research group (2014 SGR 123) and the city hall of Puigverd de Lleida. This project has received funding from the European Union’s Horizon 2020 research and innovation programme under grant agreement No 657466 (INPATH-TES). Alvaro de Gracia would like to thank Ministerio de Economia y Competitividad de España for Grant Juan de la Cierva, FJCI-2014-19940.
Recercat. Dipósit de la Recerca de Catalunya
Publicación Contribución de congreso (ConferenceOutput)

Comparative analysis of energy demand and CO2 emissions of residential buildings, Benchmarking of energy demand and CO2 emissions of domestic residential buildings

  • Coma Arpón, Julià
  • Maldonado, José Miguel
  • Gracia Cuesta, Alvaro de
  • Gimbernat, Toni
  • Botargues, Teresa
  • Cabeza, Luisa F.
Rapid expansion of solar thermal energy for increasing energy efficiency of buildings has been adopted in short/medium and long-term energy strategies of EU countries. Within this context, the overall objective of this work is to develop an innovative high performance and cost effective hybrid solar heat and power system. The initial application is to be implemented in individual dwellings and small business residential buildings for onsite electricity and heat generation using solar thermal energy. It is estimated that the proposed technology will deliver 60% of domestic energy requirements and provide 20% reduction in energy costs and greenhouse gas emissions compared to the best existing low carbon energy technologies. The aim of this study consists in performing a comparative analysis of the different building typologies, which can host this technology, and their energy demands for heating and domestic hot water, as well as their CO2 emissions., This study has received funding from Eurepean Union's Horizon 2020 research and innovation programme under grant agreement Nº 723596 (Innova MicroSolar) and Nº 657466 (INPATH-TES). The work is partially funded by the Sapnish government ENE2015-64117-C5-1-R (MINECO/FEDER) and ENE2015-64117-C5-3-R (MINECO/FEDER). GREA is certified agent TECNIO in the cathegory of technology developers from the Government of Catalonia. The authors would like to thanks the Calatan Governmnet for the quality accreditation given to their research group (2014 SGR 123). Alvaro de Gracia would like to thanks Ministerio de Economia y Competitividad de España for Grant Juan de la Cierva, FJCI-2014-19940.
Recercat. Dipósit de la Recerca de Catalunya
Publicación Artículo científico (JournalArticle)

Experimental validation of the exact analytical solution to the steady periodic heat transfer problem in a PCM layer

  • Mazzeo, Domenico
  • Oliveti, Giuseppe
  • Gracia, Álvaro de
  • Coma Arpón, Julià
  • Solé, Aran
  • Cabeza, Luisa F.
Phase change materials (PCM) are used in many industrial and residential applications for their advantageous characteristic of high capacity of latent thermal storage by means of an isothermal process. In this context, it is very useful to have predictive mathematical models for the analysis of the thermal performance and for the thermal design of these layers. In this work, an experimental validation of an analytical model that resolves the steady periodic heat transfer problem in a finite layer of PCM is presented. The experimental investigation was conducted employing a PCM with thermophysical and thermochemical behavior very close to those hypothesized in the formulation of the analytical model. For the evaluation of the thermophysical properties of the PCM sample used, an experimental procedure created by the authors was employed. In all tests realized in a sinusoidal and non-sinusoidal periodic regime, the comparison between the measured and calculated trends of the temperature at different sample heights and of the surface heat fluxes show an excellent agreement. Moreover, also having verified the analytical total stored energy, the analytical model constitutes a valid instrument for the evaluation of the latent and sensible contribution and the trend in time of the position of the bi-phase interface., The work was partially funded by the Spanish government (ENE2015-64117-C5-1-R (MINECO/FEDER), ENE2015-64117-C5-3-R (MINECO/FEDER), and ULLE10-4E-1305). GREA is certified agent TECNIO in the category of technology developers from the Government of Catalonia. The authors would like to thank the Catalan Government for the quality accreditation given to their research group (2014 SGR 123). This project has received funding from the European Commission Seventh Framework Programme (FP/2007-2013) under Grant agreement Nº PIRSES-GA-2013-610692 (INNOSTORAGE) and from European Union's Horizon 2020 research and innovation programme under grant agreement Nº 657466 (INPATH-TES). Alvaro de Gracia would like to thank Ministerio de Economia y Competitividad de España for Grant Juan de la Cierva, FJCI-2014-19940. Julià Coma would like to thank the Departament d'Universitats, Recerca i Societat de la Informació de la Generalitat de Catalunya for his research fellowship (2016FI_B2 00147). Aran Solé would like to thank Ministerio de Economía y Competitividad de España for Grant Juan de la Cierva, FJCI-2015-25741.
Recercat. Dipósit de la Recerca de Catalunya
Publicación Artículo científico (JournalArticle)

Influence of the storage period between charge and discharge in a latent heat thermal energy storage system working under partial load operating conditions

  • Gasia, Jaume
  • Gracia Cuesta, Alvaro de
  • Zsembinszki, Gabriel
  • Cabeza, Luisa F.
The supply intermittency of energy sources like solar energy or industrial waste heat should be properly addressed when studying latent heat thermal energy storage (TES) systems, since it might cause an incomplete melting/solidification of phase change materials (PCM). In the present paper, and experimental study was performed to analyse the storage period (also known as stand-by period) in a latent heat TES system working under partial load operating conditions and the effect of its duration on the subsequent discharging process. In the experimental set-up, 99.5 kg of high density polyethylene (HDPE) was used as PCM in a 0.154m3 storage tank based on the shell-and-tube heat exchanger concept. Four different percentages of charge were evaluated: 58%, 73%, 83% (partial charge), and 97% (full charge). Each charging level was followed by three different periods of storage: 25 min, 60 min, and 120 min. The fact of working at different levels of charge caused that in some regions of the TES system the PCM was not completely melted. Thus, at the end of the charging process different levels of thermal homogenisation were observed. However, during the storage period, the PCM temperature showed a tendency to homogenisation, which was influenced by the energy distribution within the PCM, the heat losses, and the duration of the storage period. Focusing on the discharging period, it was observed that the duration of the storage period slightly affected the temperature and heat transfer profiles, causing the main differences of performance during the first 30 min of process., This work was partially funded by the Ministerio de Economía y Competitividad de España (ENE2015-64117-C5-1-R (MINECO/FEDER) and ENE2015-64117-C5-3-R (MINECO/FEDER)). The authors would like to thank the Catalan Government for the quality accreditation given to their research group (2017 SGR 1537). GREA is certified agent TECNIO in the category of technology developers from the Government of Catalonia. Jaume Gasia would like to thank the Departament d'Universitats, Recerca i Societat de la Informació de la Generalitat de Catalunya for his research fellowship (2018 FI_B2 00100).
Recercat. Dipósit de la Recerca de Catalunya
Publicación Artículo científico (JournalArticle)

Control concepts of a radiant wall working as thermal energy storage for peak load shifting of a heat pump coupled to a PV array

  • Romaní Picas, Joaquim
  • Belusko, Martin
  • Alemu, Alemu
  • Cabeza, Luisa F.
  • Gracia Cuesta, Alvaro de
  • Bruno, Frank
Photovoltaic panels (PV) coupled to a heat pump supplying heat to a radiant wall is a system with potential to reduce the imported energy from the grid for heating and cooling of buildings. The radiant wall works as a thermal storage system (TES) allowing storage of the PV output and, thus, peak load shifting. However, the management of these technologies is complex due to the dynamics of the system. This paper presents several control concepts with different purposes such as shifting energy use to off-peak periods, maximizing self-consumption of PV output, and minimization of imported energy from the grid. An experimentally validated numerical model from previous research was used to investigate and compare the different proposed control concepts. Results showed that charging the wall with solar energy resulted in higher overall energy use of the heat pump, while the imported grid energy was significantly reduced, thanks to self-consumption., The authors acknowledge the South Australian Department of State Development who have funded this research through the Premier's Research Industry Fund - International Research Grant Program (IRGP 33). The work was partially funded by the Spanish government (ENE2015-64117-C5-1-R (MINECO/FEDER), ENE2015-64117-C5-3-R (MINECO/FEDER), and ULLE10-4E-1305). GREA is certified agent TECNIO in the category of technology developers from the Government of Catalonia. The authors would like to thank the Catalan Government for the quality accreditation given to their research group (2014 SGR 123) and the city hall of Puigverd de Lleida. This projects has received funding from the European Commission Seventh Framework Programme (FP/2007–2013) under Grant agreement Nº PIRSES-GA-2013-610692 (INNOSTORAGE) and from European Union's Horizon 2020 research and innovation programme under grant agreement Nº 657466 (INPATH-TES). Alvaro de Gracia would like to thank Ministerio de Economia y Competitividad de España for Grant Juan de la Cierva, FJCI-2014-19940.
Recercat. Dipósit de la Recerca de Catalunya
Publicación Artículo científico (JournalArticle)

Experimental set-up for testing active and passive systems for energy savings in buildings - Lessons learnt

  • Gracia Cuesta, Alvaro de
  • Navarro Farré, Lidia
  • Coma Arpón, Julià
  • Serrano, Susana
  • Romaní Picas, Joaquim
  • Pérez Luque, Gabriel
  • Cabeza, Luisa F.
This paper describes a building prototype experimental set-up used for testing active and passive systems for energy savings, presenting the used methodology, reviewing the main experimental results and identifying limitations. The test facility is located in Puigverd de Lleida (Spain) and has been experimentally evaluating different materials, technologies and systems which might be integrated in building design to provide energy savings for space heating and cooling since 2002. The research fields of passive technologies covered the effect of using different insulating materials, construction systems based on sustainable materials, addition of phase change materials in building envelopes and green infrastructures such as green roofs and walls. On the other hand, the active systems tested were focused in exploiting different available renewable energy source available, such a solar thermal, free-cooling with night air, or geothermal heat, using thermal energy storage systems to shift the heating and cooling loads., The work partially funded by the Spanish Government (ENE2008-06687-C02-01/CON, ENE2011-28269-C03-02, ENE2015-64117-C5-1-R (MINECO/FEDER) and ENE2015-64117-C5-3-R (MINECO/FEDER), and ULLE10-4E-1305). Financiado por el proyectoRTC-2015-3583-5 (INPHASE) del Ministerio de Economía y Competitividad, dentro del Programa Estatal de Investigación, Desarrollo e Innovación Orientada a los Retos de la Sociedad, en el marco del Plan Estatal de Investigación Científica y Técnica y de Innovación 2013–2016, y ha sido cofinanciado con FONDOS FEDER, con el objetivo de promover el desarrollo tecnológico, la innovación y una investigación de calidad GREA is certified agent TECNIO in the category of technology developers from the Government of Catalonia. The authors would like to thank the Catalan Government for the quality accreditation given to their research group (2014 SGR 123) and the city hall of Puigverd de Lleida. The research leading to these results has received funding from the European Union's Seventh Framework Programe (FP7/2007-2013) under grant agreement no. PIRSES-GA-2013-610692 (INNOSTORAGE), from MOPCON Project (EU CRAFT ref. G5ST-CT-2002-50331), from Eccoinnovation Project Rewastee ECO/13/630286 and from European Union's Horizon 2020 Research and Innovation Programme under grant agreement No. 657466 (INPATH-TES) and from EEA-Grants under grant IDI-20140914. This work was supported by the “Corporación Tecnológica de Andalucía” by means of the project “MECLIDE-Soluciones estructurales con materiales especiales para la climatización diferida de edificios” with the collaboration of DETEA. Alvaro de Gracia would like to thank Ministerio de Economia y Competitividad de España for Grant Juan de la Cierva, FJCI-2014-19940. Julià Coma would like to thank the Departament d′Universitats, Recerca i Societat de la Informació de la Generalitat de Catalunya for his research fellowship. Cecilia Castellón, Pablo Arce, Albert Castell, Cristian Solé, Pere Moreno and Lídia Rincón participated in the experimentation in this set-up.
Recercat. Dipósit de la Recerca de Catalunya
Publicación Artículo científico (JournalArticle)

Numerical simulation of a PCM packed bed system: A review

  • Gracia Cuesta, Alvaro de
  • Cabeza, Luisa F.
The detailed study of latent packed bed thermal energy storage (TES) system has been a great topic of interest in the literature. Experimental measurements have been conducted to analyze the performance of these systems, however, the complex transient nature of latent TES makes necessary the use of numerical models for detailed study and evaluation of key design parameters, which lead to a numerous scientific contributions in the field. Different and diverse numerical models have been developed, which can be mainly divided into single phase models, Schumman's model, concentric dispersion model, and continuous solid phase model. This paper provides an extensive comprehensive revision of the different numerical models, highlighting the key aspects of each one as well as the main findings in the field. Furthermore, the performance of the different methodologies are discussed and compared. The most important empirical correlations used in the different models in order to take into account physics, such as natural convection inside the spheres or effective thermal conductivity of heat transfer fluid, are also given., The work partially funded by the Spanish Government (ENE2015-64117-C5-1-R (MINECO/FEDER) and ENE2015-64117-C5-3-R (MINECO/FEDER)). The authors would like to thank the Catalan Government for the quality accreditation given to their research group (2014 SGR 123). This project has received funding from the European Commission Seventh Framework Programme (FP/2007-2013) under Grant agreement no. PIRSES-GA-2013-610692 (INNOSTORAGE) and from the European Union's Horizon 2020 research and innovation programme under Grant agreement no. 657466 (INPATH-TES). Alvaro de Gracia would like to thank Ministerio de Economia y Competitividad de España for Grant Juan de la Cierva, FJCI-2014-19940.
Recercat. Dipósit de la Recerca de Catalunya
Publicación Artículo científico (JournalArticle)

Model predictive control strategy applied to different types of building for space heating

  • Gholamibozanjani, Gohar
  • Tarragona Roig, Joan
  • Gracia Cuesta, Alvaro de
  • Fernàndez Camon, César
  • Cabeza, Luisa F.
  • Farid, Mohammed M.
In recent years, the concept of energy-efficient buildings has attracted widespread attention due to growing energy consumption in different types of buildings. The application of thermal energy storage (TES) systems, especially latent heat energy storage (LHES), has become a promising approach to improve thermal efficiency of buildings and hence reduce CO2 emissions. One way to achieve this, could be by implementing a model predictive control (MPC) strategy, using weather and electricity cost predictions. To this end, a heat exchanger unit containing a phase change material (PCM) as a LHES medium, thermally charged by solar energy was incorporated into three versions of a standard building. This paper reports on the use of EnergyPlus software to simulate the heating demand profile of these buildings, with Solving Constraint Integer Programs (SCIP) as the optimization tool. After applying MPC strategy, the energy costs of different building types were evaluated. Furthermore, the effect of prediction horizon and decision time step of MPC strategy, and PCM mass capacity on the performance of the MPC were all investigated in 1 and 7-day simulations. Results showed that by increasing the prediction horizon and PCM mass, more cost saving could be obtained. However, in terms of decision time step, although the study revealed that increasing it led to a higher energy saving, it made the system more sensitive to sharp changes as it failed to provide an accurate reading of the parameters and variables., The study was partially funded by the Spanish Government (ENE2015-64117-C5-1-R (MINECO/FEDER) and ENE2015-64117-C5-3-R (MINECO/FEDER)). The authors at the University of Lleida would like to thank the Catalan Government for the quality accreditation given to their research group (2017 SGR 1537). GREiA is the certified agent for TECNIO in the category technology developers for the Government of Catalonia. The research leading to these results also received funding from the European Union's Seventh Framework Programme (FP7/2007-2013) under grant agreement no. PIRSES-GA-2013-610692 (INNOSTORAGE).
Recercat. Dipósit de la Recerca de Catalunya
Publicación Artículo científico (JournalArticle)

Economic and environmental potential for solar assisted central heating plants in the EU residential sector: Contribution to the 2030 climate and energy EU agenda

  • Tulus, Victor
  • Abokersh, Mohamed Hany
  • Cabeza, Luisa F.
  • Vallès Rasquera, J. Manel
  • Jiménez, Laureano
  • Boer, Dieter
Aligning with the ambitious EU 2030 climate and energy package for cutting the greenhouse emissions and replacing conventional heat sources through the presence of renewable energy share inside efficient district heating fields, central solar heating plants coupled with seasonal storage (CSHPSS) can have a viable contribution to this goal. However, the technical performance variation combined with inadequate financial assessment and insufficient environmental impact data associated with the deployment of those innovative district heating systems represents a big challenge for the broad implementation of CSHPSS in Europe. In this context, our paper presents a comprehensive evaluation for the possibility of integrating CSHPSS in the residential sector in various EU member states through the formulation of a multi-objective optimization framework. This framework comprises the life cycle cost analysis for the economic evaluation and the life cycle assessment for the environmental impact estimation simultaneously. The technical performance is also considered by satisfying both the space heating demand and the domestic hot water services. The methodological framework is applied to a residential neighborhood community of 1120 apartments in various EU climate zones with Madrid, Athens, Berlin, and Helsinki acting as a proxy for the Mediterranean continental, Mediterranean, central European, and Nordic climates, respectively. The optimization results regarding the energy performance show that the CSHPSS can achieve a renewable energy fraction above 90% for the investigated climate zones. At the same time, the environmental assessment shows significant improvement when using the CSHPSS in comparison to a natural gas heating system, in those cases the environmental impact is reduced up to 82.1-86.5%. On the other hand, substantial economic improvement is limited, especially in the Mediterranean climate zone (Athens) due to low heating demands and the prices of the non-renewable resources. There the total economic cost of the CSHPSS plants can increase up to 50.8% compared to a natural gas heating system. However, considering the incremental tendency in natural gas prices all over EU nowadays, the study of future plant costs confirms its favorable longterm economic feasibility., The authors would like to acknowledge financial support from the Spanish Ministry of Economy and Competitiveness (ENE2015-64117-C5-1-R (MINECO/FEDER), ENE2015-64117-C5-3-R (MINECO/FEDER) and CTQ2016-77968 (MINECO/FEDER)) and Martí i Franquès COFUND Fellowship program. This project has received funding from the European Union's Horizon 2020 research and innovation programme under the Marie Skłodowska-Curie grant agreement No. 713679. The authors at the University of Lleida would like to thank the Catalan Government for the quality accreditation given to their research group (2017 SGR 1537). GREA is certified agent TECNIO in the category of technology developers from the Government of Catalonia.
Recercat. Dipósit de la Recerca de Catalunya
Publicación Artículo científico (JournalArticle)

Experimental testing of cooling internal loads with a radiant wall

  • Romaní Picas, Joaquim
  • Cabeza, Luisa F.
  • Pérez Luque, Gabriel
  • Pisello, Anna Laura
  • Gracia Cuesta, Alvaro de
Thermally activated building systems (TABS) consist of pipes or ducts embedded in the building structure. This is a well-known technology for its capability to reduce energy use for cooling buildings. Additionally, TABS help integrating renewable energies, such as free-cooling with ground heat exchangers (GHE). However, TABS cooling load is sensitive to the internal load, and the use of GHE for free-cooling is limited to low energy buildings. In a previously published research, a radiant wall cubicle without internal gains demonstrated to achieve significant energy savings. However, the current research showed that under domestic and office scheduled internal gains equivalent to 42 W·m-2 the radiant cubicle increased its energy consumption for cooling more than the reference cubicle with air-to-air heat pumps. As a result, the radiant cubicle used around 20% more energy than the reference at air temperature set-point 24 ºC but saved around 20% compared to the reference at 26 ºC. Despite this, the radiant wall could still reduce the cooling cost through peak load shifting even though it showed to consume more energy than a conventional HP., The work was partially funded by the Spanish government (ENE2015-64117-C5-1-R (MINECO/FEDER), ENE2015-64117-C5-3-R (MINECO/FEDER), and ULLE10-4E-1305). GREA is certified agent TECNIO in the category of technology developers from the Government of Catalonia. The authors would like to thank the Catalan Government for the quality accreditation given to their research group (2014 SGR 123) and the city hall of Puigverd de Lleida. This projects has received funding from the European Commission Seventh Framework Programme (FP/2007–2013) under Grant agreement Nº PIRSES-GA-2013-610692 (INNOSTORAGE) and from European Union's Horizon 2020 research and innovation programme under grant agreement Nº 657466 (INPATH-TES). Alvaro de Gracia would like to thank Ministerio de Economia y Competitividad de España for Grant Juan de la Cierva, FJCI-2014-19940.
Recercat. Dipósit de la Recerca de Catalunya
Publicación Contribución de congreso (ConferenceOutput)

Optimization of coupled building roof solar reflectance and thermal insulation level for annual energy saving under different climate zones

  • Piselli, Cristina
  • Pisello, Anna Laura
  • Gracia Cuesta, Alvaro de
  • Saffari Tabalvandani, Mohammad
  • Cotana, Franco
  • Cabeza, Luisa F.
The aim of this work is to assess building energy performance optimization potential of cool roof solutions in different climate conditions worldwide through dynamic thermal-energy simulation and optimization analysis. Moreover, given the dependence of roof performance on insulation level, the influence of roof insulation variation on optimum roof solar reflectance is evaluated. Therefore, the multi-dimensional optimization of combined building roof solar reflectance capability and thermal insulation level is carried out to minimize annual energy consumption for air-conditioning of standard ASHRAE building model for small offices, in each considered climate zone. Findings of this research highlight how the classic approach of super-insulated buildings for energy saving needs to be reframed for the office case, by integrating other passive solutions for truly environmentally friendly and comfortable buildings., The research leading to these results has received funding from the European Union's Horizon 2020 research and innovation programme under grant agreement N°657466 (INPATH-TES). The work is partially funded by the Spanish government (ENE2015-64117-C5-1-R (MINECO/FEDER) and ENE2015-64117-C5-3-R (MINECO/FEDER)). The authors from the University of Lleida would like to thank the Catalan Government for the quality accreditation given to their research group (2014 SGR 123). Anna Laura Pisello’s acknowledgments are due to the UNESCO Chair “Water Resources Management and Culture”, for supporting her research. Alvaro de Gracia would like to thank Ministerio de Economia y Competitividad de España for Grant Juan de la Cierva, FJCI-2014-19940.
Recercat. Dipósit de la Recerca de Catalunya
Publicación Contribución de congreso (ConferenceOutput)

Benchmarking of energy demand of domestic and small business buildings

  • Coma Arpón, Julià
  • Maldonado, José Miguel
  • Gracia Cuesta, Alvaro de
  • Gimbernat, Toni
  • Botargues, Teresa
  • Cabeza, Luisa F.
Rapid expansion of solar thermal energy for increasing energy efficiency of buildings has been adopted in short/medium and long-term energy strategies of EU countries. This enhancement of energy efficiency in buildings is in line with regional actions with the European climate energy objectives as defined in the European Union’s “20-20-20” targets and in the European Commission’s Energy Roadmap 2050. Within this context, the overall objective of this work is to develop an innovative high performance and cost effective hybrid solar heat and power system, which consist in a novel flat Fresnel mirror solar concentrating collector and micro organic Rankine cycle plant combined with advanced phase change materials as thermal storage, all system managed by smart control units. The initial application is to be implemented in individual dwellings and small business residential buildings for on-site electricity and heat generation using solar thermal energy. It is estimated that the proposed technology will deliver 60% of domestic energy requirements and provide 20% reduction in energy costs and greenhouse gas emissions compared to the best existing low carbon energy technologies. To reach the main objectives, the first step consist in providing information on features of architecture of domestic and small business residential buildings and their annual energy demands for different countries such as: Spain, France Germany, Italy, and United Kingdom. This will include detailed building information of envelopes (walls, roof, lofts, etc.), structure, fabric, and results of energy demands (domestic hot water, space heating and electricity) for the abovementioned countries. This information will be used as input data during the development of this technology as it will point out the potential benefits of the system in different countries, climates, and building typologies., This study has received funding from European Union’s Horizon 2020 research and innovation programme under grant agreement Nº723596 (Innova MicroSolar) and Nº 657466 (INPATH-TES), from the European Commission Seventh Framework Programme (FP/2007-2013) under grant agreement Nº PIRSES-GA-2013-610692 (INNOSTORAGE). The work is partially funded by the Spanish government ENE2015- 64117-C5-1-R (MINECO/FEDER), ENE2015-64117-C5-3-R (MINECO/FEDER) and (ULLE10-4E-1305). GREA is certified agent TECNIO in the category of technology developers from the Government of Catalonia. The authors would like to thank the Catalan Government for the quality accreditation given to their research group (2014 SGR 123). Alvaro de Gracia would like to thank Ministerio de Economia y Competitividad de España for Grant Juan de la Cierva, FJCI-2014-19940.
Recercat. Dipósit de la Recerca de Catalunya
Publicación Artículo científico (JournalArticle)

New formulation and characterization of enhanced bulk-organic phase change materials

  • Palacios, Anabel
  • Gracia Cuesta, Alvaro de
  • Cabeza, Luisa F.
  • Julià Bolivar, José Enrique
  • Fernández Renna, Ana Inés
  • Barreneche Güerisoli, Camila
The main drawbacks faced by researchers to successfully implement organic-PCM as materials to improve the thermal performance of building systems are their low thermal conductivity, their high flammability, and their low thermal cycling stability. T In the present work, authors present a new enhanced PCM formulations aimed to solve the stated disadvantages in organic bulk-PCM. The new enhanced PCM were prepared by adding high thermal conductivity particles and two kinds of flame retardants into organic PCM (paraffin and fatty acid eutectic mixtures). In the first stage, the effective thermal conductivity of organic-PCM was increased by using two different methods: directly dispersion of powder graphite (PG) bulk-PCM and vacuum impregnation of PCM into expanded graphite (EG). In the second stage, the fire reaction behaviour of the thermal conductivity enhanced PCM formulations was improved by adding two kind of flame retardant: magnesium hydroxide and ammonium phosphate (APP).. Their fire reaction behaviour, thermal conductivity and thermophysical properties were measured by adapting the dripping test (UNE 23727-90), the hot-wire method and Differential Scanning Calorimetry (DSC), respectively. The enhanced PCM composites show a self-extinguished behaviour in terms of fire performance mechanism. The EG working with endothermic and phosphates flame retardants improve the fire performance of PCM by acting as a synergic system and the thermal conductivity is increased. However, their thermal storage capacity is significant decreased due to the large amount of flame retardant added (up to 40%). The thermal reliability was also tested, the enhanced PCM composites were stable up to 1000 thermal cycles., The research leading to these results has received funding from the European Commission Seventh Framework Programme (FP/2007-2013) under grant agreement n° PIRSES-GA-2013-610692 (INNOSTORAGE) and from the European Union's Horizon 2020 research and innovation program under grant agreement No 657466 (INPATH-TES). The authors would like to thank the Catalan Government for the quality accreditation given to their research groups GREA (2014 SGR 123), DIOPMA (2014 SGR 1543) and GICITED (2014 SGR 1298). The work partially funded by the Spanish government (ENE2015-64117-C5-1-R (MINECO/FEDER), ENE2015-64117-C5-2-R(MINECO/FEDER), and ENE2015-64117-C5-3-R(MINECO/FEDER)). Dr. Alvaro de Gracia and Dr. Camila Barreneche would like to thank Ministerio de Economia y Competitividad de España for Grant Juan de la Cierva, FJCI-2014-19940 and FJCI-2014-22886, respectively.
Recercat. Dipósit de la Recerca de Catalunya
Publicación Artículo científico (JournalArticle)

Simulation and control of thermally activated building systems (TABS)

  • Romaní Picas, Joaquim
  • Gracia Cuesta, Alvaro de
  • Cabeza, Luisa F.
Buildings account for a significant amount of global energy use and CO2 emissions. Thermally Activated Building Systems (TABS) are a technology with potential for significantly reducing buildings energy use. TABS are heating and cooling systems that are integrated in the building structure. They mainly exchange heat through radiation and are able to store heat in the building thermal mass. TABS high thermal mass and their interaction with the building structure make their energy evaluation and design process difficult. Development of simulation models has been essential to study the design and control of TABS. Control of TABS is challenging due to the slow response time and storage capacity. A lot of research has been conducted to develop control strategies that fully exploit its energy saving potential and that maximize the use of renewable energies. This paper summarizes the main characteristics of TABS and presents the developed simulation models and control strategies., The authors would like to thank the Catalan Government for the quality accreditation given to their research group (2014 SGR 123). This projects has received funding from the European Commission Seventh Framework Programme (FP/2007-2013) under Grant agreement N° PIRSES-GA-2013-610692 (INNOSTORAGE) and from European Union’s Horizon 2020 research and innovation programme under grant agreement N° 657466 (INPATH-TES) and from EEA-Grants under grant IDI-20140914. The work was partially funded by the Spanish government grant ENE2015-64117-C5-1-R and grant ENE2015-64117-C5-3-R. Alvaro de Gracia would like to thank Ministerio de Economia y Competitividad de España for Grant Juan de la Cierva, FJCI-2014-19940.
Recercat. Dipósit de la Recerca de Catalunya
Publicación Artículo científico (JournalArticle)

Passive cooling of buildings with phase change materials using whole-building energy simulation tools: A review

  • Saffari Tabalvandani, Mohammad
  • Gracia Cuesta, Alvaro de
  • Ushak, Svetlana
  • Cabeza, Luisa F.
Buildings contribute to climate change by consuming a considerable amount of energy to provide thermal comfort for occupants. Cooling energy demands are expected to increase substantially in the world. On this basis, technologies and techniques providing high energy efficiency in buildings such as passive cooling are highly appreciated. Passive cooling by means of phase change materials (PCM) offers high potential to decrease the cooling energy demand and to improve the indoor comfort condition. However, in order to be appropriately characterized and implemented into the building envelope, the PCM use should be numerically analyzed. Whole-building energy simulation tools can enhance the capability of the engineers and designers to analyze the thermal behavior of PCM-enhanced buildings. In this paper, an extensive review has been made, with regard to whole-building energy simulation for passive cooling, addressing the possibilities of applying different PCM-enhanced components into the building envelope and also the feasibility of PCM passive cooling system under different climate conditions. The application of PCM has not always been as energy beneficial as expected, and actually its effectiveness is highly dependent on the climatic condition, on the PCM melting temperature and on the occupants behavior. Therefore, energy simulation of passive PCM systems is found to be a single-objective or multi-objective optimization problem which requires appropriate mathematical models for energy and comfort assessment which should be further investigated. Moreover, further research is required to analyze the influence of natural night ventilation on the cooling performance of PCM., The work is partially funded by the Spanish government (ENE2015-64117-C5-1-R (MINECO/FEDER) and ENE2015-64117-C5-3-R (MINEDO/FEDER)). The authors would like to thank the Catalan Government for the quality accreditation g iven to their research group GREA (2014 SGR 123). This project has received funding from the European Commission Seventh Framework Program (FP/2007-2013) under Grant agreement Nº PIRSES-GA-2013-610692 (INNOSTORAGE) and from the European Union’s Horizon 2020 research and innovation program under grant ag reement No 657466 (INPATH-TES). Alvaro de Gracia would like to thank Ministerio de Economia y Competitividad de España for Grant Juan de la Cierva, FJCI-2014-19940.
Recercat. Dipósit de la Recerca de Catalunya
Publicación Artículo científico (JournalArticle)

Simulation-based optimization of PCM melting temperature to improve the energy performance in buildings

  • Saffari Tabalvandani, Mohammad
  • Gracia Cuesta, Alvaro de
  • Fernàndez Camon, César
  • Cabeza, Luisa F.
Globally, a considerable amount of energy is consumed by the building sector. The building envelope can highly influence the energy consumption in buildings. In this regard, innovative technologies such as thermal energy storage (TES) can help to boost the energy efficiency and to reduce the CO2 emissions in this sector. The use of phase change materials (PCM), due to its high heat capacity, has been the centre of attention of many researchers. A considerable number of papers have been published on the application of PCM as passive system in building envelopes. Researches have shown that choosing the PCM melting temperature in different climate conditions is a key factor to improve the energy performance in buildings. In the present paper, a simulation-based optimization methodology will be presented by coupling EnergyPlus and GenOpt with an innovative enthalpy-temperature (h-T) function to define the optimum PCM peak melting temperature to enhance the cooling, heating, and the annual total heating and cooling energy performance of a residential building in various climate conditions based on Köppen-Geiger classification. Results show that in a cooling dominant climate the best PCM melting temperature to reduce the annual energy consumption is close to the maximum of 26ºC (melting range of 24ºC-28ºC), whereas in heating dominant climates PCM with lower melting temperature of 20ºC (melting range of 18ºC-22ºC) yields higher annual energy benefits. Moreover, it was found that the proper selection of PCM melting temperature in each climate zone can lead to notable energy savings for cooling energy consumption, heating energy consumption, and total annual energy consumption., The work is partially funded by the Spanish government (ENE2015-64117-C5-1-R (MINECO/FEDER) and ENE2015-64117-C5-3-R (MINECO/FEDER)). The authors would like to thank the Catalan Government for the quality accreditation given to their research group GREA (2014 SGR 123). GREA is certified agent TECNIO in the category of technology developers from the Government of Catalonia. This project has received funding from the European Commission Seventh Framework Program (FP/2007-2013) under Grant agreement Nº PIRSES-GA-2013-610692 (INNOSTORAGE) and from the European Union’s Horizon 2020 research and innovation program under grant agreement No 657466 (INPATH-TES). Alvaro de Gracia would like to thank Ministerio de Economia y Competitividad de España for Grant Juan de la Cierva, FJCI-2014-19940.
Recercat. Dipósit de la Recerca de Catalunya
Publicación Artículo científico (JournalArticle)

Vertical greenery systems for energy savings in buildings: a comparative study between green walls and green facades

  • Coma Arpón, Julià
  • Pérez Luque, Gabriel
  • Gracia Cuesta, Alvaro de
  • Burés, Silvia
  • Urrestarazu, Miguel
  • Cabeza, Luisa F.
During the last decade, vertical greenery systems are increasing their presence in building designs, providing several urban ecosystem services. One of them is the potential to provide energy savings in buildings, which develops an important role, however, data about its performance during winter periods is still scarce. Therefore, the main objective of this paper is to compare at real scale the thermal performance of two different vertical greenery systems implemented in experimental houses-like cubicles for both cooling and heating periods. A double-skin green facade has been installed in the first cubicle that uses deciduous creeper plants, while the second one is designed with green walls made with evergreen species. Finally, a third identical cubicle without any green coverage is used as reference. Two different types of experiments have been carried out to test the performance of the house like-cubicles. One consists of controlling the internal ambient temperature providing heating or cooling to maintain the desired comfort conditions. On the other hand, to study the thermal response of the construction system, the heating, ventilation and air conditioning system was disconnected and the cubicles were tested under free floating condition. First results showed a high potential for energy savings during cooling season for green wall (58.9%) and double-skin green facade (33.8%) in comparison to the reference system. On the other hand, for heating periods no extra energy consumption was observed for evergreen system., The work partially funded by the Spanish government (ENE2015-64117-C5-1-R (MINECO/FEDER), ENE2015-64117-C5-3-R (MINECO/FEDER) and ULLE10-4E-1305) in collaboration with the company Buresinnova S.A (C/Saragossa, 95 Entsol 3a, 08006 BARCELONA). The authors would like to thank the Catalan Government for the quality accreditation given to their research group (2014 SGR 123) and to the city hall of Puigverd de Lleida. This study has received funding from the European Commission Seventh Framework Programme (FP/2007–2013) under Grant agreement Nº PIRSES-GA-2013-610692 (INNOSTORAGE) and from European Union's Horizon 2020 research and innovation programme under grant agreement Nº 657466 (INPATH-TES). Alvaro de Gracia would like to thank Ministerio de Economia y Competitividad de España for Grant Juan de la Cierva, FJCI-2014-19940. Julià Coma would like to thank the Departament d'Universitats, Recerca i Societat de la Informació de la Generalitat de Catalunya for his research fellowship.
Recercat. Dipósit de la Recerca de Catalunya
Publicación Artículo científico (JournalArticle)

Supercritical CO2 as heat transfer fluid: A review

  • Cabeza, Luisa F.
  • Gracia Cuesta, Alvaro de
  • Fernández Renna, Ana Inés
  • Farid, Mohammed M.
This paper presents a comprehensive review of all correlations and experimental studies available in the literature to determine the heat transfer coefficient of supercritical CO2 flowing in heat exchangers. The different applications in which it is used are also reviewed and discussed. The correlations obtained from extensive experimental measurements are presented for different geometries (horizontal, vertical and inclined tubes, closed-loop circular pipes, and mini-channels) and dimensions. The review shows that there is a lack of a unique universal correlation for each geometry, suggesting the need for more work in this area., The work partially funded by the Spanish government (ENE2015-64117-C5-1-R (MINECO/FEDER) and ENE2015-64117-C5-3-R (MINECO/FEDER)). The authors would like to thank the Catalan Government for the quality accreditation given to their research group (2014 SGR 123). This project has received funding from the European Commission Seventh Framework Programme (FP/2007-2013) under Grant agreement N°PIRSES-GA-2013-610692 (INNOSTORAGE) and from the European Union’s Horizon 2020 research and innovation programme under grant agreement No 657466 (INPATH-TES), and the funds received by the Royal Society of New Zealand. Alvaro de Gracia would like to thank Ministerio de Economia y Competitividad de España for Grant Juan de la Cierva, FJCI-2014-19940.
Recercat. Dipósit de la Recerca de Catalunya
Publicación Artículo científico (JournalArticle)

Multi-objective optimisation of bio-based thermal insulation materials in building envelopes considering condensation risk

  • Torres Rivas, Alba
  • Palumbo, Mariana
  • Haddad, Assed Naked
  • Cabeza, Luisa F.
  • Jiménez, Laureano
  • Boer, Dieter
The reduction in energy demand for heating and cooling with insulation materials increases the material related environmental impact. Thus, implementing low embodied energy materials may equilibrate this trade-off. Actual trends in passive house postulate bio-based materials as an alternative to conventional ones. Despite that, the implementation of those insulators should be carried out with a deeper analysis due to their hygroscopic properties. The moisture transfer, the associated condensation risk and the energy consumption for seven biobased materials and polyurethane for a building-like cubicle are analysed. The performance is evaluated combining a software application to model the cubicle (EnergyPlus) and a tool to optimize its performance (jEPlus). The novelty of this optimization approach is to include and evaluate the effects of moisture in these insulation materials, taking into account the mass transfer through the different layers and the evaporation of the different materials. This methodology helps optimise the insulation type and thickness verifying the condensation risk, preventing the deterioration of the materials. The total cost of the different solutions is quantified, and the environmental impact is determined using the life cycle assessment methodology. The effect of climate conditions and the envelope configuration, as well as the risk of condensation, are quantified. The results show that cost and environmental impact can be reduced if bio-based materials are used instead of conventional ones, especially in semiarid climates. Condensation risk occurs for large thicknesses and in humid climates. In our case studies, hemp offered the most balanced solution., The authors would like to acknowledge financial support from the Spanish Government (CTQ2016-77968-C3-1-P, ENE2015-64117-C5-1-R, ENE2015-64117-C5-3-R, MINECO/FEDER, UE). The research leading to these results has received funding from the European Commission Seventh Framework Programme under grant agreement no. PIRSES-GA-2013-610692 (INNOSTORAGE). This project has received funding the European Union's Horizon 2020 Research and Innovation Program under grant agreement No 657466 (INPATH-TES). This article has been possible with the support of the Ministerio de Economía y Competitividad (MINECO) and the Universitat Rovira i Virgili (URV) (FJCI-2016-28789). Authors would like to acknowledge the Brazilian Government for their support by the CNPq (National Council for Scientific and Technological Development). M.P. would like to thank the Brazilian Education Ministry for the financial support received under the PNPD/Capes fellowship. L.F.C. would like to thank the Catalan Government for the quality accreditation given to her research group GREA (2014 SGR 123).
Recercat. Dipósit de la Recerca de Catalunya
Publicación Artículo científico (JournalArticle)

Experimental evaluation of a cooling radiant wall coupled to a ground heat exchanger

  • Romaní Picas, Joaquim
  • Pérez Luque, Gabriel
  • Gracia Cuesta, Alvaro de
A building prototype was built in the experimental set-up located in Puigverd de Lleida (Spain) to study the energy performance of a radiant wall with ventilated facade cooled with a ground coupled heat-exchanger. The installed geothermal heat pump operates only as a ground coupled heat exchanger on cooling mode, thus providing free-cooling. In this case, only the circulation pumps consume power. The summer experimental campaign showed the energy savings potential and the peak load shifting ability of the system. On continuous operation and taking as reference a cubicle equipped with a conventional air-to-air heat pump, the radiant wall cooled with the ground coupled heat-exchanger achieved savings up to 54.17% and 82.08% at set-point temperatures of 24 °C and 26 °C, respectively. The thermal storage capacity of the system was studied in night charging test, when the cubicles were pre-cooled during night-time. During the day, the temperature raise caused by heat loads was small and the system kept the temperature inside comfort range despite it only operated overnight. However, the performance was very sensitive to set-point temperature. Free-cooling was limited by the temperatures in the boreholes, showing that with lower set-points the gradient between supply temperature and room temperature was small, and thus it required a higher water flow to achieve the necessary cooling power. Intermittent operation of the system according to different schedules also affected the radiant walls performance as they interacted with the thermal inertia of the system, which could even have a negative impact on energy use., The work partially funded by the Spanish government (ULLE10-4E-1305, ENE2015-64117-C5-1-R(MINECO/FEDER), ENE2015-64117-C5-3-R (MINECO/FEDER)). The authors would like to thank the Catalan Government for the quality accreditation given to their research group (2014 SGR 123) and the city hall of Puigverd de Lleida. This projects has received funding from the European Commission Seventh Framework Programme (FP/2007-2013) under Grant agreement No. PIRSES-GA-2013-610692 (INNOSTORAGE) and from European Union’s Horizon 2020 research and innovation programme under grant agreement No 657466 (INPATH-TES) and from EEA-Grants under grant IDI-20140914. Alvaro de Gracia would like to thank Ministerio de Economia y Competitividad de España for Grant Juan de la Cierva, FJCI-2014-19940.
Recercat. Dipósit de la Recerca de Catalunya
Publicación Contribución de congreso (ConferenceOutput)

Benchmarking of energy demand of domestic and small business buildings

  • Coma Arpón, Julià
  • Maldonado, José Miguel
  • Gracia Cuesta, Alvaro de
  • Gimbernat, Toni
  • Botargues, Teresa
  • Cabeza, Luisa F.
In Europe the building sector represents 41% of the final energy consumption and the 40% of the total GHG emissions of end-use sectors (Directive 2010/31/EU) [1]. Solar energy is one of the forms of renewable energy that has great potential to enable EU the ambition of 12% of heating coming from renewable sources by 2020 [2]. Within this context, the overall objective of the project Innovative Micro Solar Heat and Power System (Innova MicroSolar) is to develop a high performance and cost effective solar heat and power system, which consist in a novel flat Fresnel mirror solar concentrating collector and micro organic Rankine cycle plant combined with advanced phase change materials as thermal storage, all system managed by smart control units. This technology will be initially implemented in individual dwellings and small business residential buildings for on-site electricity and heat generation using solar thermal energy., This study has received funding from European Union’s Horizon 2020 research and innovation programme under grant agreement Nº723596 (Innova MicroSolar) and Nº 657466 (INPATHTES), from the European Commission Seventh Framework Programme (FP/2007-2013) under grant agreement Nº PIRSES-GA-2013-610692 (INNOSTORAGE). The work is partially funded by the Spanish government (ENE2015-64117-C5-1-R (MINECO/FEDER) and ENE2015- 64117-C5-3-R (MINECO/FEDER)). GREA is certified agent TECNIO in the category of technology developers from the Government of Catalonia. The authors would like to thank the Catalan Government for the quality accreditation given to their research group (2014 SGR 123). Alvaro de Gracia would like to thank Ministerio de Economia y Competitividad de España for Grant Juan de la Cierva, FJCI-2014-19940.
Recercat. Dipósit de la Recerca de Catalunya
Publicación Contribución de congreso (ConferenceOutput)

Ensayos preliminares de una microturbina de ciclo orgánico de Rankine alimentada por un campo solar de concentración tipo Fresnel lineala

  • Maldonado, José Miguel
  • Gracia Cuesta, Alvaro de
  • Mahkamov, Khamid
  • Costa, Carolina
  • Kenisarin, Murat
  • Pili, Piero
  • Manca, Roberto
  • Leroux, Arthur
  • Mintsa, André Charles
  • Bartolini, Carlo M.
  • Pirro, Matteo
  • Lynn, Kevin
  • Mullen, David
  • Halimic, Elvedin
  • Cabeza, Luisa F.
El propósito de esta investigación es evaluar la influencia del tipo de cemento en sí mismo a altas temperaturas, desestimando el resto de componentes del hormigón. El presente estudio se centra en la comparación del tratamiento de dos tipos de cemento, a saber, cemento Portland (OPC) y cemento aluminoso (cemento de aluminato de calcio, CAC). Se determina las características físicas y resistencias mecánicas a compresión. A pesar de la resistencia a altas temperaturas del CAC y la baja relación agua/cemento (a/c) utilizada, este tipo de pasta de cemento requiere de un curado inminente. Si tal hidratación no se ejecuta en sus primeras edades, la pasta de CAC muestra un comportamiento similar a la pasta de OPC, desaprovechando tanto sus características refractarias como sus altas resistencias mecánicas iniciales., The purpose of this investigation is to evaluate the influence of cement type itself, at high temperatures, disregarding the rest of the concrete components. The present study focuses on the treatment comparison of two cement types, known as, ordinary Portland cement (OPC) and calcium aluminate cement (CAC). The physical characteristics and compressive strength are determined. Despite the resistance to high temperatures of the CAC and the low water/cement (w/c) ratio used, this type of cement paste requires an imminent cure at certain temperature. If such hydration is not carried out in its early ages, the CAC paste shows a behavior similar to OPC paste, wasting both its refractory characteristics and its high initial mechanical resistances., Este trabajo ha sido parcialmente financiado el programa de Investigación y Desarrollo H2020 de la Unión Europea, a través del Grant Agreement 723596, cuyo nombre de referencia es Innova MicroSolar. Este trabajo ha sido cofinanciado por el Ministerio de Economía y Competitividad de España (ENE2015-64117-C5-1-R (MINECO/FEDER) y ENE2015-64117-C5-3-R (MINECO/FEDER)). Los autores quieren agradecer al Gobierno de Cataluña por la acreditación de calidad otorgada a su grupo de investigación (2017 SGR 1537). GREA es un agente TECNIO certificado en la categoría de desarrolladores tecnológicos por el Gobierno de Cataluña. José Miguel Maldonado agradece al Gobierno de España la concesión de la ayuda para contratos predoctorales para la formación de doctores (BES-2016-076554). Alvaro de Gracia agradece los fondos recibidos del programa de Investigación y Desarrollo H2020 de la Unión Europea, a través del Marie Sklodowska-Curie Grant Agreement No 712949.