Zaguán. Repositorio Digital de la Universidad de Zaragoza
Publicación Artículo científico (JournalArticle)

An Optimization Approach to Eliminate Crosstalk in Zero-Potential Circuits for Reading Resistive Sensor Arrays

  • Domínguez-Gimeno, Sergio
  • Medrano-Sánchez, Carlos
  • Igual-Catalán, Raúl
  • Martínez-Cesteros, Javier
  • Plaza-García, Inmaculada
Crosstalk is a well-known problem in resistive sensor arrays (RSAs). The zero-potential method (ZPM) is a commonly used readout circuit that uses multiplexers and demultiplexers to reduce the main sources of crosstalk. However, the internal resistors of these switches cause a secondary crosstalk in the RSA that alters the RSA sensor values read. The solution to the effects of this secondary crosstalk is still a case of study. In previous literature, these resistances have been considered as known and, in most cases, equal for all switch channels. However, in a real situation, they are unknown and may vary between channels. In this work, a least-squares (LSQR) method is presented to obtain the true values of the switches from the read voltage signals. Calibration columns are added to the RSA for this purpose. To prove the performance of the method proposed, several simulations have been carried out with different values of RSA sensors, switch resistances, size of the RSA, and noise level. Results show that the proposed LSQR method allows obtaining simultaneously accurate values for both the RSA sensors and switch internal resistors. In this way, the problem of secondary crosstalk is neutralized. It also shows better performance when compared with existing approaches.
Zaguán. Repositorio Digital de la Universidad de Zaragoza
Publicación Artículo científico (JournalArticle)

Uncertainty Analysis in the Inverse of Equivalent Conductance Method for Dealing with Crosstalk in 2-D Resistive Sensor Arrays

  • Martinez-Cesteros, J.
  • Medrano-Sanchez, C.
  • Plaza-Garcia, I.
  • Igual-Catalan, R.
2-D resistive sensor arrays (RSAs) appear in many applications to measure physical quantities in a surface. However, they suffer from a crosstalk problem when the simplest configuration is used to address a row-column. Thus, the value of a single cell cannot be measured directly. Several hardware solutions have been proposed to solve it totally or partially but all of them make the circuit more complex. In a previous paper we proposed an innovative numerical solution to eliminate crosstalk after a complete scan of the matrix, which is named in this paper as Inverse of Equivalent Conductance Method (IECM). In the current study, we have analyzed the implications of the method for the uncertainty of the calculated cell resistance by first deriving the sensitivity of the solution and then applying uncertainty propagation theory. The theoretical results have been tested in simulated arrays and in a real 6x6 RSA with known values of resistances with good agreement. The uncertainty analysis is able to predict which values are reliable. In general, the lowest resistances of the array are better solved by IECM as expected. In addition, it is also shown that IECM has the potential to be adapted to other hardware configurations that reduce crosstalk, helping to overcome some of its limitations. IEEE
Zaguán. Repositorio Digital de la Universidad de Zaragoza
Publicación Artículo científico (JournalArticle)

Creep and hysteresis compensation in pressure-sensitive mats for improving center-of-pressure measurements

  • Martínez-Cesteros, Javier
  • Medrano-Sánchez, Carlos
  • Castellanos-Ramos, Julián
  • Sánchez-Durán, José A.
  • Plaza-García, Inmaculada
Large-area tactile sensors are used to image the pressure exerted by human body parts. More specifically, they can be used to measure plantar pressure on human stability tests. The center-of-pressure (CoP) trajectory is the primary outcome of such tests. Previous research has shown that the parameters obtained from the trajectory correlate with those obtained from a reference instrument, that is, a force platform (FP). However, there are still noticeable differences. In this work, a low-cost prototype of a pressure-sensitive mat (PSM) has been built and compared with an FP in stability tests. The sensitive material is Velostat, which is readily available. Such a mat could make objective stability tests more accessible. A model of two nonlinear effects, hysteresis and creep, has been considered to compensate for them. Given that it was rather difficult to characterize the large mat with a pneumatic device, a small-sized sensor array was first characterized in a controlled environment. Then the model was extended to the large mat using a suitable scaling factor. The experimental results show that compensating for the nonlinear effects led to a decrease in the differences between the two instruments, the FP and the mat, with an average improvement of 26% in the distance between the trajectories.
Zaguán. Repositorio Digital de la Universidad de Zaragoza
Publicación Artículo científico (JournalArticle)

A velostat-based pressure-sensitive mat for center-of-pressure measurements: A preliminary study

  • Martinez-Cesteros J.
  • Medrano-Sanchez C.
  • Plaza-Garcia I.
  • Igual-Catalan R.
  • Albiol-Pérez S.
Center-of-pressure (CoP) displacements play a key role in studies assessing postural stability. The accepted instrument to measure CoP trajectories is the force platform, but pressure-sensitive mats (PSMs) are an alternative composed of a matrix of sensitive cells. A typical cell comprises two electrodes with piezoresistive material in between, while a force platform has a force sensor at each of its corners. In this paper, we compare a homemade Velostat-based PSM and an affordable commercial mat with a commercial force platform in a test series with 42 healthy volunteers in single-legged trials (29 males, 13 females; height 1.74 (0.09) m, weight 74.3 (16.34) kg, age 31.21 (12.66) years). The aim of the research was to perform a preliminary study of the performance of our prototype to measure CoP, and more specifically, the standard deviation of the CoP path on both axes, the medial–lateral and anterior–posterior. We could thus discover several improvements for future clinical applications. The intraclass correlation coefficient (ICC) for agreement in the base experiment showed a moderate value for the prototype (0.38 to 0.63) and lower values for the commercial mat (0.11 to 0.12). However, we identified several factors that were relevant to improve ICC and reduce error by considering several processing options: (i) the known crosstalk problem between cells that appears in this kind of mats must be eliminated; (ii) the response time of the sensor has to be taken into account; and (iii) increasing the mat resolution also improves agreement. Therefore, as future work, we plan to test the improved version of the prototype in a clinical environment.