Zaguán. Repositorio Digital de la Universidad de Zaragoza
Publicación Reseña (Review)

Sensing Systems for Respiration Monitoring: A Technical Systematic Review

  • Vanegas Vásquez, Erik
  • Igual Catalán, Raúl
  • Plaza García, Inmaculada
Respiratory monitoring is essential in sleep studies, sport training, patient monitoring, or health at work, among other applications. This paper presents a comprehensive systematic review of respiration sensing systems. After several systematic searches in scientific repositories, the 198 most relevant papers in this field were analyzed in detail. Different items were examined: sensing technique and sensor, respiration parameter, sensor location and size, general system setup, communication protocol, processing station, energy autonomy and power consumption, sensor validation, processing algorithm, performance evaluation, and analysis software. As a result, several trends and the remaining research challenges of respiration sensors were identified. Long-term evaluations and usability tests should be performed. Researchers designed custom experiments to validate the sensing systems, making it difficult to compare results. Therefore, another challenge is to have a common validation framework to fairly compare sensor performance. The implementation of energy-saving strategies, the incorporation of energy harvesting techniques, the calculation of volume parameters of breathing, or the effective integration of respiration sensors into clothing are other remaining research efforts. Addressing these and other challenges outlined in the paper is a required step to obtain a feasible, robust, affordable, and unobtrusive respiration sensing system.
Zaguán. Repositorio Digital de la Universidad de Zaragoza
Publicación Artículo científico (JournalArticle)

An Optimization Approach to Eliminate Crosstalk in Zero-Potential Circuits for Reading Resistive Sensor Arrays

  • Domínguez-Gimeno, Sergio
  • Medrano-Sánchez, Carlos
  • Igual-Catalán, Raúl
  • Martínez-Cesteros, Javier
  • Plaza-García, Inmaculada
Crosstalk is a well-known problem in resistive sensor arrays (RSAs). The zero-potential method (ZPM) is a commonly used readout circuit that uses multiplexers and demultiplexers to reduce the main sources of crosstalk. However, the internal resistors of these switches cause a secondary crosstalk in the RSA that alters the RSA sensor values read. The solution to the effects of this secondary crosstalk is still a case of study. In previous literature, these resistances have been considered as known and, in most cases, equal for all switch channels. However, in a real situation, they are unknown and may vary between channels. In this work, a least-squares (LSQR) method is presented to obtain the true values of the switches from the read voltage signals. Calibration columns are added to the RSA for this purpose. To prove the performance of the method proposed, several simulations have been carried out with different values of RSA sensors, switch resistances, size of the RSA, and noise level. Results show that the proposed LSQR method allows obtaining simultaneously accurate values for both the RSA sensors and switch internal resistors. In this way, the problem of secondary crosstalk is neutralized. It also shows better performance when compared with existing approaches.
Zaguán. Repositorio Digital de la Universidad de Zaragoza
Publicación Artículo científico (JournalArticle)

Uncertainty Analysis in the Inverse of Equivalent Conductance Method for Dealing with Crosstalk in 2-D Resistive Sensor Arrays

  • Martinez-Cesteros, J.
  • Medrano-Sanchez, C.
  • Plaza-Garcia, I.
  • Igual-Catalan, R.
2-D resistive sensor arrays (RSAs) appear in many applications to measure physical quantities in a surface. However, they suffer from a crosstalk problem when the simplest configuration is used to address a row-column. Thus, the value of a single cell cannot be measured directly. Several hardware solutions have been proposed to solve it totally or partially but all of them make the circuit more complex. In a previous paper we proposed an innovative numerical solution to eliminate crosstalk after a complete scan of the matrix, which is named in this paper as Inverse of Equivalent Conductance Method (IECM). In the current study, we have analyzed the implications of the method for the uncertainty of the calculated cell resistance by first deriving the sensitivity of the solution and then applying uncertainty propagation theory. The theoretical results have been tested in simulated arrays and in a real 6x6 RSA with known values of resistances with good agreement. The uncertainty analysis is able to predict which values are reliable. In general, the lowest resistances of the array are better solved by IECM as expected. In addition, it is also shown that IECM has the potential to be adapted to other hardware configurations that reduce crosstalk, helping to overcome some of its limitations. IEEE
Zaguán. Repositorio Digital de la Universidad de Zaragoza
Publicación Artículo científico (JournalArticle)

Creep and hysteresis compensation in pressure-sensitive mats for improving center-of-pressure measurements

  • Martínez-Cesteros, Javier
  • Medrano-Sánchez, Carlos
  • Castellanos-Ramos, Julián
  • Sánchez-Durán, José A.
  • Plaza-García, Inmaculada
Large-area tactile sensors are used to image the pressure exerted by human body parts. More specifically, they can be used to measure plantar pressure on human stability tests. The center-of-pressure (CoP) trajectory is the primary outcome of such tests. Previous research has shown that the parameters obtained from the trajectory correlate with those obtained from a reference instrument, that is, a force platform (FP). However, there are still noticeable differences. In this work, a low-cost prototype of a pressure-sensitive mat (PSM) has been built and compared with an FP in stability tests. The sensitive material is Velostat, which is readily available. Such a mat could make objective stability tests more accessible. A model of two nonlinear effects, hysteresis and creep, has been considered to compensate for them. Given that it was rather difficult to characterize the large mat with a pneumatic device, a small-sized sensor array was first characterized in a controlled environment. Then the model was extended to the large mat using a suitable scaling factor. The experimental results show that compensating for the nonlinear effects led to a decrease in the differences between the two instruments, the FP and the mat, with an average improvement of 26% in the distance between the trajectories.
Zaguán. Repositorio Digital de la Universidad de Zaragoza
Publicación Artículo científico (JournalArticle)

Application of an optimization algorithm to reduce crosstalk in voltage feedback methods

  • Domínguez-Gimeno, Sergio
  • Igual Catalán, Raúl
  • Medrano Sánchez, Carlos
  • Plaza García, Inmaculada
Resistive sensor arrays (RSA) exhibit crosstalk between adjacent cells. The issues mainly related to parasitic coupling (crosstalk) that needs to be reduced. This crosstalk is due to a double effect. Firstly, the impossibility of isolating a single sensor when its corresponding row and column are selected by means of switches. Secondly, the internal resistances of these switches also affect sensor measurement. Several readout circuits have been proposed to neutralize the first effect. Two of the most relevant circuits are called the zero potential method (ZPM) and the voltage feedback method (VFM). However, these circuits do not correct the second effect. To solve this, in a previous study a least-square algorithm was successfully applied to the ZPM circuit. This paper applies the same algorithm to the VFM circuit, showing its generalization ability to comprehensively correct crosstalk. Results show that this optimization approach is suitable for several RSA readout circuits.
Zaguán. Repositorio Digital de la Universidad de Zaragoza
Publicación Artículo científico (JournalArticle)

A velostat-based pressure-sensitive mat for center-of-pressure measurements: A preliminary study

  • Martinez-Cesteros J.
  • Medrano-Sanchez C.
  • Plaza-Garcia I.
  • Igual-Catalan R.
  • Albiol-Pérez S.
Center-of-pressure (CoP) displacements play a key role in studies assessing postural stability. The accepted instrument to measure CoP trajectories is the force platform, but pressure-sensitive mats (PSMs) are an alternative composed of a matrix of sensitive cells. A typical cell comprises two electrodes with piezoresistive material in between, while a force platform has a force sensor at each of its corners. In this paper, we compare a homemade Velostat-based PSM and an affordable commercial mat with a commercial force platform in a test series with 42 healthy volunteers in single-legged trials (29 males, 13 females; height 1.74 (0.09) m, weight 74.3 (16.34) kg, age 31.21 (12.66) years). The aim of the research was to perform a preliminary study of the performance of our prototype to measure CoP, and more specifically, the standard deviation of the CoP path on both axes, the medial–lateral and anterior–posterior. We could thus discover several improvements for future clinical applications. The intraclass correlation coefficient (ICC) for agreement in the base experiment showed a moderate value for the prototype (0.38 to 0.63) and lower values for the commercial mat (0.11 to 0.12). However, we identified several factors that were relevant to improve ICC and reduce error by considering several processing options: (i) the known crosstalk problem between cells that appears in this kind of mats must be eliminated; (ii) the response time of the sensor has to be taken into account; and (iii) increasing the mat resolution also improves agreement. Therefore, as future work, we plan to test the improved version of the prototype in a clinical environment.
Zaguán. Repositorio Digital de la Universidad de Zaragoza
Publicación Artículo científico (JournalArticle)

Force-sensitive mat for vertical jump measurement to assess lower limb strength: Validity and reliability study

  • Vanegas E.
  • Salazar Y.
  • Igual R.
  • Plaza I.
Background: Vertical jump height is widely used in health care and sports fields to assess muscle strength and power from lower limb muscle groups. Different approaches have been proposed for vertical jump height measurement. Some commonly used approaches need no sensor at all; however, these methods tend to overestimate the height reached by the subjects. There are also novel systems using different kind of sensors like force-sensitive resistors, capacitive sensors, and inertial measurement units, among others, to achieve more accurate measurements. Objective: The objective of this study is twofold. The first objective is to validate the functioning of a developed low-cost system able to measure vertical jump height. The second objective is to assess the effects on obtained measurements when the sampling frequency of the system is modified. Methods: The system developed in this study consists of a matrix of force-sensitive resistor sensors embedded in a mat with electronics that allow a full scan of the mat. This mat detects pressure exerted on it. The system calculates the jump height by using the flight-time formula, and the result is sent through Bluetooth to any mobile device or PC. Two different experiments were performed. In the first experiment, a total of 38 volunteers participated with the objective of validating the performance of the system against a high-speed camera used as reference (120 fps). In the second experiment, a total of 15 volunteers participated. Raw data were obtained in order to assess the effects of different sampling frequencies on the performance of the system with the same reference device. Different sampling frequencies were obtained by performing offline downsampling of the raw data. In both experiments, countermovement jump and countermovement jump with arm swing techniques were performed. Results: In the first experiment an overall mean relative error (MRE) of 1.98% and a mean absolute error of 0.38 cm were obtained. Bland-Altman and correlation analyses were performed, obtaining a coefficient of determination equal to R2=.996. In the second experiment, sampling frequencies of 200 Hz, 100 Hz, and 66.6 Hz show similar performance with MRE below 3%. Slower sampling frequencies show an exponential increase in MRE. On both experiments, when dividing jump trials in different heights reached, a decrease in MRE with higher height trials suggests that the precision of the proposed system increases as height reached increases. Conclusions: In the first experiment, we concluded that results between the proposed system and the reference are systematically the same. In the second experiment, the relevance of a sufficiently high sampling frequency is emphasized, especially for jump trials whose height is below 10 cm. For trials with heights above 30 cm, MRE decreases in general for all sampling frequencies, suggesting that at higher heights reached, the impact of high sampling frequencies is lesser.