RiuNet. Repositorio Institucional de la Universitat Politécnica de Valéncia
Publicación Artículo científico (JournalArticle)

The SNR of Positron Emission Data With Gaussian and Non-Gaussian Time-of-Flight Kernels, With Application to Prompt Photon Coincidence

  • Nuyts, Johan
  • Defrise, Michel
  • Gundacker, Stefan
  • Roncali, Emilie
  • Lecoq, Paul
[EN] It is well known that measurement of the time-of-flight (TOF) increases the information provided by coincident events in positron emission tomography (PET). This information increase propagates through the reconstruction and improves the signal-to-noise ratio in the reconstructed images. Takehiro Tomitani has analytically computed the gain in variance in the reconstructed image, provided by a particular TOF resolution, for the center of a uniform disk and for a Gaussian TOF kernel. In this paper we extend this result, by computing the signal-to-noise ratio (SNR) contributed by individual coincidence events for two different tasks. One task is the detection of a hot spot in the center of a uniform cylinder. The second one is the same as that considered by Tomitani, i.e. the reconstruction of the central voxel in the image of a uniform cylinder. In addition, we extend the computation to non-Gaussian TOF kernels. It is found that a modification of the TOF-kernel changes the SNR for both tasks in almost exactly the same way. The proposed method can be used to compare TOF-systems with different and possibly event-dependent TOF-kernels, as encountered when prompt photons, such as Cherenkov photons are present, or when the detector is composed of different scintillators. The method is validated with simple 2D simulations and illustrated by applying it to PET detectors producing optical photons with event-dependent timing characteristics., This work was supported in part by the Research Foundation-Flanders (FWO) under Grant G062220N.
RiuNet. Repositorio Institucional de la Universitat Politécnica de Valéncia
Publicación Artículo científico (JournalArticle)

2D feasibility study of joint reconstruction of attenuation and activity in limited angle TOF-PET

  • Vergara, Marina
  • Rezaei, Ahmadreza
  • Schramm, Georg
  • Nuyts, Johan
  • Rodríguez-Álvarez, M.J.|||0000-0001-8333-8792
  • Benlloch Baviera, Jose María|||0000-0001-6073-1436
[EN] Several research groups are studying organ-dedicated limited angle positron emission tomography (PET) systems to optimize performance-cost ratio, sensitivity, access to the patient, and/or flexibility. Often open systems are considered, typically consisting of two detector panels of various sizes. Such systems provide incomplete sampling due to limited angular coverage and/or truncation, which leads to artifacts in the reconstructed activity images. In addition, these organ-dedicated PET systems are usually stand-alone systems, and as a result, no attenuation information can be obtained from anatomical images acquired in the same imaging session. It has been shown that the use of time-of-flight (TOF) information reduces incomplete data artifacts and enables the joint estimation of the activity and the attenuation factors. In this work, we explore with simple 2-D simulations the performance and stability of a joint reconstruction algorithm, for imaging with a limited angle PET system. The reconstruction is based on the so-called maximum-likelihood attenuation correction factors (MLACF) algorithm and uses linear attenuation coefficients in a known-tissue-class region to obtain absolute quantification. Different panel sizes and different TOF resolutions are considered. The noise propagation is compared to that of MLEM reconstruction with exact attenuation correction (AC) for the same PET system. The results show that with good TOF resolution, images of good visual quality can be obtained. If also a good scatter correction can be implemented, quantitative PET imaging will be possible. Further research, in particular on scatter correction, is required., This work was supported in part by the European Research Council (ERC) through the European Unions Horizon 2020 Research and Innovation Program under Grant 695536; in part by the Research Foundation Flanders (FWO) under Project 12T7118N and Project G062220N; and in part by the NIH Project under Grant 1P41EB017183-01A1.
RiuNet. Repositorio Institucional de la Universitat Politécnica de Valéncia
Publicación Artículo científico (JournalArticle)

How the sensitivity of TOF-PET depends on the interplay between the temporal and spatial detector resolutions and the resolution required for the imaging task

  • Nuyts, Johan
  • Defrise, Michel
  • Morel, Christian
  • Lecoq, Paul
[EN] Objective. Sensitivity is a key feature of positron emission tomography (PET). Here, sensitivity can be defined as the reciprocal of the amount of injected radioactivity needed to obtain a sufficient image quality for a particular scan duration. PET sensitivity can not only be increased by increasing the solid angle covered by the detectors, but also by improving their spatial and the temporal resolution, which in turn determines the time-of-flight (TOF) resolution. This paper analyzes how the interplay between the spatial detector resolution, the TOF resolution and the required imaging resolution affects the sensitivity of a TOF-PET system. Approach. Two approaches are studied. The first computes the performance of the Hoteling observer for discriminating a small hot spot from a less small and less hot spot with the same total activity. This approach is flexible, and elegant closed form equations are obtained. In the second approach, analytical equations are derived for the variance of the reconstructed voxel values as a function of the TOF and spatial detector resolutions and of the reconstruction point spread function. To keep the mathematics tractable, the derivations are done for the center of a uniform sphere or cylinder, which is placed in the center of a cylindrical or spherical PET system. The results are verified with simulation experiments for 2D PET and 3D PET with septa. Main results. Both approaches confirm that the sensitivity of the PET system increases, when the spatial detector resolution is improved, in agreement with simulation results published by Muehllehner (1985 Phys. Med. Biol. 30 163). The same is true for improvements of the TOF resolution. Remarkably, when the TOF resolution (converted to a distance) approaches the spatial resolution, further improving it increases the sensitivity more than expected based on experience with current TOF-PET systems and on the analysis for moderate TOF resolution (Tomitani 1981 IEEE Trans. Nucl. Sci. NS-28 4582-9). This agrees with simulation results published recently by Toussaint et al (2020 IEEE Trans. Radiat. Plasma Med. Sci. 5 729-37). Finally, our new Equations confirm that the value of a TOF-kernel is well characterized by the integral of its square, as was reported previously (Nuyts et al 2022 IEEE Trans. Med. Imaging 42 1254-64; Nuyts et al 2022 Phys. Med. Biol. 69 015011). Significance. This analysis explains how spatial detector resolution and TOF accuracy contribute to the sensitivity of PET systems, and predicts that pushing the TOF resolution well below 100 ps will produce a larger benefit than expected based on current rules of thumb., ThisworkwassupportedinpartbytheResearchFoundation-Flanders(FWO)underGrant G062220N.
RiuNet. Repositorio Institucional de la Universitat Politécnica de Valéncia
Publicación Artículo científico (JournalArticle)

The SNR of time-of-flight positron emission tomography data for joint reconstruction of the activity and attenuation images

  • Nuyts, Johan
  • Defrise, Michel
  • Morel, Christian
  • Lecoq, Paul
[EN] Objective. Measurement of the time-of-flight (TOF) difference of each coincident pair of photons increases the effective sensitivity of positron emission tomography (PET). Many authors have analyzed the benefit of TOF for quantification and hot spot detection in the reconstructed activity images. However, TOF not only improves the effective sensitivity, it also enables the joint reconstruction of the tracer concentration and attenuation images. This can be used to correct for errors in CT- or MR-derived attenuation maps, or to apply attenuation correction without the help of a second modality. This paper presents an analysis of the effect of TOF on the variance of the jointly reconstructed attenuation and (attenuation corrected) tracer concentration images. Approach. The analysis is performed for PET systems that have a distribution of possibly non-Gaussian TOF-kernels, and includes the conventional Gaussian TOF-kernel as a special case. Non-Gaussian TOF-kernels are often observed in novel detector designs, which make use of two (or more) different mechanisms to convert the incoming 511 keV photon to optical photons. The analytical result is validated with a simple 2D simulation. Main results. We show that if two different TOF-kernels are equivalent for image reconstruction with known attenuation, then they are also equivalent for joint reconstruction of the activity and the attenuation images. The variance increase in the activity, caused by also jointly reconstructing the attenuation image, vanishes when the TOF-resolution approaches perfection. Significance. These results are of interest for PET detector development and for the development of stand-alone PET systems., This work was supported in part by the Research Foundation-Flanders (FWO) under Grant G062220N and by NIH/NIBIB grant P41EB017183, CAI2R, New York University.