DESARROLLO DEL SOFTWARE PARA SISTEMA DE DIAGNOSTICO POR IMAGEN MOLECULAR PARA CORAZON EN CONDICIONES DE STRESS

TEC2016-79884-C2-2-R

•
Nombre agencia financiadora Agencia Estatal de Investigación
Acrónimo agencia financiadora AEI
Programa Programa Estatal de I+D+i Orientado a los Retos de la Sociedad
Convocatoria Proyectos I+D+i Retos de Investigación
Año convocatoria 2016
Plan Estatal 2013-2016 Plan Estatal de Investigación Científica y Técnica y de Innovación
Centro beneficiario UNIVERSITAT POLITÈCNICA DE VALÈNCIA

Resultados relacionados

Resultados totales (Incluyendo duplicados): 13
Encontrada(s) 1 página(s)

RiuNet. Repositorio Institucional de la Universitat Politécnica de Valéncia
Publicación Artículo científico (JournalArticle)

NEMA Performance Evaluation of CareMiBrain dedicated brain PET and Comparison with the whole-body and dedicated brain PET systems

  • Moliner Martínez, Laura
  • Rodríguez-Álvarez, M.J.|||0000-0001-8333-8792
  • González Martínez, Antonio Javier
  • Benlloch Baviera, Jose María|||0000-0001-6073-1436
  • CATRET MASCARELL, JUAN VICENTE
  • Ilisie, Victor
[EN] This article presents system performance studies of the CareMiBrain dedicated brain PET according to NEMA NU 2-2012 (for whole-body PETS) and NU 4-2008 (for preclinical PETs). This scanner is based on monolithic LYSO crystals coupled to silicon photomultipliers. The results obtained for both protocols are compared with current commercial whole body PETs and dedicated brain PETs found in the literature. Spatial resolution, sensitivity, NECR and scatter-fraction are characterized with NEMA standards, as well as an image quality study. A customized image quality phantom is proposed as NEMA phantoms do not fulfil the necessities of dedicated brain PETs. The full-width half maximum of the radial/tangential/ axial spatial resolution of CareMiBrain reconstructed with FBP at 10 and 100 mm from the system center were, respectively, 1.87/1.68/1.39 mm and 1.86/1.91/1.40 mm (NU 2-2012) and 1.58/1.45/1.40 mm and 1.64/1.66/1.44 mm (NU 4-2008). Peak NECR was 49 kcps@287 MBq with a scatter fraction of 48% using NU 2-2012 phantom. The sensitivity was 13.82 cps/kBq at the center of the FOV (NU 2-2012) and 10% (NU 4-2008). Contrast recovery coefficients for customizing image quality phantom were 0.73/0.78/1.14/1.01 for the 4.5/6/9/12 mm diameter rods. The performance characteristics of CareMiBrain are at the top of the current technologies for PET systems. Dedicated brain PET systems significantly improve spatial resolution and sensitivity, but present worse results in count rate measurements and scatter-fraction tests. As for the comparison of preclinical and clinical standards, the results obtained for solid and liquid sources were similar., This study was funded by the Spanish Ministry of Science, Innovation and University under grant RTC-2016-5186-1, a project co-financed by the European Union through the European Regional Development Fund (ERDF). CareMiBrain system was funding from the European Union's Horizon 2020 research and innovation programme under grant agreement No. 711323. Author Dr. Jose Maria Benlloch owns a small percentage of Oncovision S.A. The other authors declare no potential conflict of interest.
RiuNet. Repositorio Institucional de la Universitat Politécnica de Valéncia
Publicación Artículo científico (JournalArticle)

Graph-based methods for simultaneous smoothing and sharpening of color images

  • Pérez-Benito, Cristina
  • Jordan-Lluch, Cristina|||0000-0001-9608-2984
  • Conejero, J. Alberto|||0000-0003-3681-7533
  • Morillas, Samuel|||0000-0001-9262-6139
[EN] In this work we introduce an image characterization of pixels based on local graphs that allows to distinguish different local regions around a pixel. This separation also permits us to develop a method for determining the role of each pixel in a neighborhood of any other, either for smoothing or for sharpening. Two methods for simultaneously conducting both processes are provided. Our solution overcomes the drawbacks of the classic two steps sequential smoothing and sharpening process: enhancing details while reducing noise and not losing critical information. The parameters of the methods are adjusted in two different ways: through observers visual quality optimization and with an objective optimization criterion. The results show that our methods outperform other recent state-of-the-art ones., We thank F. Russo for providing the implementation of the Fuzzy method and V. Ratmer, and Y.Y. Zeevi for providing the implementation of the FAB method. Cristina Jordan acknowledges the support of grant TEC2016-79884-C2-2-R. Samuel Morillas acknowledges the support of grant MTM2015-64373-P (MINECO/FEDER, Spain, UE).
RiuNet. Repositorio Institucional de la Universitat Politécnica de Valéncia
Publicación Artículo científico (JournalArticle)

A model based on local graphs for colour images and its application for Gaussian noise smoothing

  • Pérez-Benito, Cristina
  • Morillas, Samuel|||0000-0001-9262-6139
  • Jordan-Lluch, Cristina|||0000-0001-9608-2984
  • Conejero, J. Alberto|||0000-0003-3681-7533
[EN] In this paper, a new model for processing colour images is presented. A graph is built for each image pixel taking into account some constraints on links. Each pixel is characterized depending on the features of its related graph, which allows to process it appropriately. As an example, we provide a characterization of each pixel based on the link cardinality of its connected component. This feature enables us to properly distinguish flat image regions respect to edge and detail regions. According to this, we have designed a hybrid filter for colour image smoothing. It combines a filter able to properly process flat image regions with another one that is more appropriate for details and texture. Experimental results show that our model performs appropriately. We also see that our proposed filter is competitive with respect to state-of-the-art methods. It is close closer to the corresponding optimal switching filter respect to other analogous hybrid method., Samuel Morillas acknowledges the support of grant MTM2015-64373-P (MINECO/FEDER, UE). Cristina Jordan acknowledges the support of grant TEC2016-79884-C2-2-R.
RiuNet. Repositorio Institucional de la Universitat Politécnica de Valéncia
Publicación Artículo científico (JournalArticle)

A new class of iterative processes for solving nonlinear systems by using one divided differences operator

  • Cordero Barbero, Alicia|||0000-0002-7462-9173
  • Jordan-Lluch, Cristina|||0000-0001-9608-2984
  • Sanabria-Codesal, Esther|||0000-0002-4523-1991
  • Torregrosa Sánchez, Juan Ramón|||0000-0002-9893-0761
[EN] In this manuscript, a new family of Jacobian-free iterative methods for solving nonlinear systems is presented. The fourth-order convergence for all the elements of the class is established, proving, in addition, that one element of this family has order five. The proposed methods have four steps and, in all of them, the same divided difference operator appears. Numerical problems, including systems of academic interest and the system resulting from the discretization of the boundary problem described by Fisher's equation, are shown to compare the performance of the proposed schemes with other known ones. The numerical tests are in concordance with the theoretical results., This research has been supported partially by Spanish Ministerio de Ciencia, Innovacion y Universidades PGC2018-095896-B-C22, PGC2018-094889-B-I00, TEC2016-79884-C2-2-R and also by Spanish grant PROMETEO/2016/089 from Generalitat Valenciana.
RiuNet. Repositorio Institucional de la Universitat Politécnica de Valéncia
Publicación Contribución de congreso (ConferenceOutput)

Deep learning for MRI-based CT synthesis: a comparison of MRI sequences and neural network architectures

  • Larroza, Andrés
  • Álvarez-Gómez, Juan Manuel
  • Espinós-Morató, Héctor
  • Vergara-Díaz, Marina
  • Moliner Martínez, Laura
  • Oliver-Gil, Sandra|||0000-0001-8258-3972
  • Rodríguez-Álvarez, M.J.|||0000-0001-8333-8792
[EN] Synthetic computed tomography (CT) images derived from magnetic resonance images (MRI) are of interest for radiotherapy planning and positron emission tomography (PET) attenuation correction. In recent years, deep learning implementations have demonstrated improvement over atlasbased and segmentation-based methods. Nevertheless, several open questions remain to be addressed, such as which is the best of MRI sequences and neural network architectures. In this work, we compared the performance of different combinations of two common MRI sequences (T1- and T2-weighted), and three state-of-the-art neural networks designed for medical image processing (Vnet, HighRes3dNet and ScaleNet). The experiments were conducted on brain datasets from a public database. Our results suggest that T1 images perform better than T2, but the results further improve when combining both sequences. The lowest mean average error over the entire head (MAE = 101.76 ± 10.4 HU) was achieved combining T1 and T2 scans with HighRes3dNet. All tested deep learning models achieved significantly lower MAE (p < 0.01) than a well-known atlas-based method., This work was supported by the Spanish Government grants TEC2016-79884-C2 and RTC-2016-5186-1, and by the European Union through the European Regional Development Fund (ERDF)
RiuNet. Repositorio Institucional de la Universitat Politécnica de Valéncia
Publicación Artículo científico (JournalArticle)

Simulation Study of a Frame-Based Motion Correction Algorithm for Positron Emission Imaging

  • Espinós-Morató, Héctor
  • Cascales-Picó, David
  • Vergara, Marina
  • Hernández-Martínez, Ángel
  • Benlloch Baviera, Jose María|||0000-0001-6073-1436
  • Rodríguez-Álvarez, M.J.|||0000-0001-8333-8792
[EN] Positron emission tomography (PET) is a functional non-invasive imaging modality that uses radioactive substances (radiotracers) to measure changes in metabolic processes. Advances in scanner technology and data acquisition in the last decade have led to the development of more sophisticated PET devices with good spatial resolution (1¿3 mm of full width at half maximum (FWHM)). However, there are involuntary motions produced by the patient inside the scanner that lead to image degradation and potentially to a misdiagnosis. The adverse effect of the motion in the reconstructed image increases as the spatial resolution of the current scanners continues improving. In order to correct this effect, motion correction techniques are becoming increasingly popular and further studied. This work presents a simulation study of an image motion correction using a frame-based algorithm. The method is able to cut the acquired data from the scanner in frames, taking into account the size of the object of study. This approach allows working with low statistical information without losing image quality. The frames are later registered using spatio-temporal registration developed in a multi-level way. To validate these results, several performance tests are applied to a set of simulated moving phantoms. The results obtained show that the method minimizes the intra-frame motion, improves the signal intensity over the background in comparison with other literature methods, produces excellent values of similarity with the ground-truth (static) image and is able to find a limit in the patient-injected dose when some prior knowledge of the lesion is present., This research has been co-financed by the Spanish Government Grants TEC2016-79884-C2, PID2019-107790RB-C22, and PEJ2018-002230-A-AR; the Generalitat Valenciana GJIDI/2018/A/040l and the PTA2019-017113-1/AEI/10.13039/501100011033; the European Union through the European Regional Development Fund (ERDF); and the European Research Council (ERC) under the European Union's Horizon 2020 research and innovation program (Grant Agreement No. 695536).
RiuNet. Repositorio Institucional de la Universitat Politécnica de Valéncia
Publicación Artículo científico (JournalArticle)

2D feasibility study of joint reconstruction of attenuation and activity in limited angle TOF-PET

  • Vergara, Marina
  • Rezaei, Ahmadreza
  • Schramm, Georg
  • Nuyts, Johan
  • Rodríguez-Álvarez, M.J.|||0000-0001-8333-8792
  • Benlloch Baviera, Jose María|||0000-0001-6073-1436
[EN] Several research groups are studying organ-dedicated limited angle positron emission tomography (PET) systems to optimize performance-cost ratio, sensitivity, access to the patient, and/or flexibility. Often open systems are considered, typically consisting of two detector panels of various sizes. Such systems provide incomplete sampling due to limited angular coverage and/or truncation, which leads to artifacts in the reconstructed activity images. In addition, these organ-dedicated PET systems are usually stand-alone systems, and as a result, no attenuation information can be obtained from anatomical images acquired in the same imaging session. It has been shown that the use of time-of-flight (TOF) information reduces incomplete data artifacts and enables the joint estimation of the activity and the attenuation factors. In this work, we explore with simple 2-D simulations the performance and stability of a joint reconstruction algorithm, for imaging with a limited angle PET system. The reconstruction is based on the so-called maximum-likelihood attenuation correction factors (MLACF) algorithm and uses linear attenuation coefficients in a known-tissue-class region to obtain absolute quantification. Different panel sizes and different TOF resolutions are considered. The noise propagation is compared to that of MLEM reconstruction with exact attenuation correction (AC) for the same PET system. The results show that with good TOF resolution, images of good visual quality can be obtained. If also a good scatter correction can be implemented, quantitative PET imaging will be possible. Further research, in particular on scatter correction, is required., This work was supported in part by the European Research Council (ERC) through the European Unions Horizon 2020 Research and Innovation Program under Grant 695536; in part by the Research Foundation Flanders (FWO) under Project 12T7118N and Project G062220N; and in part by the NIH Project under Grant 1P41EB017183-01A1.
RiuNet. Repositorio Institucional de la Universitat Politécnica de Valéncia
Publicación Artículo científico (JournalArticle)

Graphs based methods for simultaneous smoothing and sharpening

  • Pérez-Benito, Cristina
  • Jordan-Lluch, Cristina|||0000-0001-9608-2984
  • Conejero, J. Alberto|||0000-0003-3681-7533
  • Morillas, Samuel|||0000-0001-9262-6139
[EN] We present two new methods for simultaneous smoothing and sharpening of color images: the GMS(3) (Graph Method for Simultaneous Smoothing and Sharpening) and the NGMS(3)(Normalized Graph-Method for Simultaneous Smoothing and Sharpening). They are based on analyzing the structure of local graphs computed at every pixel using their respective neighbors. On the one hand, we define a kernel-based filter for smoothing each pixel with the pixels associated to nodes in its same connected component. On the other hand, we modify each pixel by increasing their differences with respect to the pixels in the other connected components of those local graphs. Our approach is shown to be competitive with respect to other state-of-the-art methods that simultaneously manage both processes. We provide two methods that carry out the process of smoothing and sharpening simultaneously. The methods are based on the analysis of the structure of a local graph defined from the differences in the RGB space among the pixels in a 3 x 3 window. The parameters of the method are adjusted using both observers opinion and the well-known reference image quality assessment BRISQUE (Blind/Referenceless images spatial quality Evaluator) score., C. Jordan acknowledges the support of grant TEC2016-79884-C2-2-R. S. Morillas acknowledges the support of grant MTM2015-64373-P (MINECO/FEDER, UE).
RiuNet. Repositorio Institucional de la Universitat Politécnica de Valéncia
Publicación Artículo científico (JournalArticle)

Simulation Study for Designing a Dedicated Cardiac TOF-PET System

  • Oliver-Gil, Sandra|||0000-0001-8258-3972
  • Moliner Martínez, Laura
  • Benlloch Baviera, Jose María|||0000-0001-6073-1436
  • Rodríguez-Álvarez, M.J.|||0000-0001-8333-8792
  • Ilisie, V.
[EN] The development of dedicated positron emission tomography scanners is an active area of research, especially aiming at the improvement of lesion detection and in support of cancer treatment and management. Recently, dedicated Positron Emission Tomography (PET) systems with different configurations for specific organs have been developed for improving detection effectiveness. Open geometries are always subject to distortion and artifacts in the reconstructed images. Therefore, the aim of this work is to determine the optimal geometry for a novel cardiac PET system that will be developed by our team, and determine the time resolution needed to achieve reasonable image quality for the chosen geometry. The proposed geometries consist of 36 modules. These modules are arranged in two sets of two plates, each one with different configurations. We performed Monte Carlo simulations with different TOF resolutions, in order to test the image quality improvement in each case. Our results show, as expected, that increasing TOF resolution reduces distortion and artifact effects. We can conclude that a TOF resolution of the order of 200 ps is needed to reduce the artifacts, to acceptable levels, generated in the simulated cardiac-PET open geometries., This project has been co-financed by the Spanish Government Grants TEC2016-79884-C2 and RTC-2016-5186-1, by the European Union through the European Regional Development Fund (ERDF) and by the European Research Council (ERC) under the European Union's Horizon 2020 research and innovation program (Grant Agreement No. 695536). The work of V.I. was supported by the Generalitat Valenciana APOSTD/2019/086 fellowship.
RiuNet. Repositorio Institucional de la Universitat Politécnica de Valéncia
Publicación Artículo científico (JournalArticle)

TOF studies for dedicated PET with open geometries

  • Moliner Martínez, Laura
  • González Martínez, Antonio Javier
  • Oliver-Gil, Sandra|||0000-0001-8258-3972
  • Giménez-Alventosa, Vicent|||0000-0003-1646-6094
  • Rodríguez-Álvarez, M.J.|||0000-0001-8333-8792
  • F Sánchez
  • Benlloch Baviera, Jose María|||0000-0001-6073-1436
  • Ilisie, V.
  • Gonzalez, A.
  • Cañizares, G.
  • Lamprou, E.
  • Alamo, J.
[EN] Recently, two novel PET devices have been developed with open geometries, namely: breast and prostate-dedicated scanners. The breast-dedicated system comprises two detector rings of twelve modules with a field of view of 170 mm x 170 mm x 94 mm. Each module consists of a continuous trapezoidal LYSO crystal and a PSPMT. The system has the capability to vary the opening of the rings up to 60 mm in order to allow the insertion of a needle to perform a biopsy procedure. The prostate system has an open geometry consisting on two parallel plates separated 28 cm. One panel includes 18 detectors organized in a 6 x 3 matrix while the second one comprises 6 detectors organized in a 3 x 2 matrix. All detectors are formed by continuous LYSO crystals of 50 mm x 50 mm x15 mm, and a SiPM array of 12 x 12 individual photo-detectors. The system geometry is asymmetric maximizing the sensitivity of the system at the prostate location, located at about 2/3 in the abdomen-anus distance. The reconstructed images for PET scanners with open geometries present severe artifacts due to this peculiarity. These artifacts can be minimized using Time Of Flight information (TOF). In this work we present a TOF resolution study for open geometries. With this aim, the dedicated breast and prostate systems have been simulated using GATE (8.1 version) with different TOF resolutions in order to determine the image quality improvements that can be achieved with the existing TOF-dedicated electronics currently present in the market. The images have been reconstructed using the LMOS algorithm including TOF modeling in the calculation of the voxel-Line Of Response emission probabilities., This work was supported in part by the Spanish Government Grants TEC2016-79884-C2 and RTC-2016-5186-1 and by the European Research Council (ERC) under the European Union's Horizon 2020 research and innovation program (Grant Agreement No. 695536).
RiuNet. Repositorio Institucional de la Universitat Politécnica de Valéncia
Publicación Artículo científico (JournalArticle)

Determinación de componentes conexas en el análisis de zonas homogéneas y de detalle en imágenes a color, Determination of connected components in the analysis of homogeneous and detail zones in color images

  • Pérez-Benito, Cristina
  • Jordán, Cristina
  • Morillas, Samuel|||0000-0001-9262-6139
  • Conejero, J. Alberto|||0000-0003-3681-7533
[EN] A model based on local graphs to classify pixels coming from at or detail regions of an image is presented. For each pixel a local graph is dened. Its structure will depend on the similarity between neighbouring pixels. Its features allow us to classify each image pixel as belonging to one type of region or the other. This classication is an essential pre-processing technique for many Computer Vision tools, such as smoothingor sharpening of digital color images., [ES] Presentamos un modelo basado en grafos locales para clasificar los píxeles atendiendo a si pertenecen a zonas homogéneas o a zonas de detalle de una imagen. Para cada píxel se define un grafo cuya estructura dependerá de la similitud entre los píxeles adyacentes. Sus características permiten clasificar cada píxel de la imagen como perteneciente a un tipo de zona u a otra. Esta clasificación constituye un pre-procesado de la imagen primordial para múltiples ramas de Visión Artificial, como puede ser el suavizado o el realce de imágenes digitales., Samuel Morillas: MTM2015-64373-P (MINECO/FEDER);Cristina Jordán: MECD TEC2016-79884-C2-2-R y Samuel Morillas, Cristina Jordán y J. Alberto Conejero: Proyecto de Innovación Docente del Depto. de Matemática Aplicada de la Universitat Politècnica de València, PID-DMA2016: Prácticas de Teoría de Grafos aplicadas al procesamiento de imágenes.
RiuNet. Repositorio Institucional de la Universitat Politécnica de Valéncia
Publicación Artículo científico (JournalArticle)

Smoothing vs. sharpening of color images: Together or separated

  • Pérez-Benito, Cristina
  • Morillas, Samuel|||0000-0001-9262-6139
  • Jordan-Lluch, Cristina|||0000-0001-9608-2984
  • Conejero, J. Alberto|||0000-0003-3681-7533
[EN] It is still a challenge to improve the efficiency and effectiveness of image denoising and enhancement methods. There exists denoising and enhancement methods that are able to improve visual quality of images. This is usually obtained by removing noise while sharpening details and improving edges contrast. Smoothing refers to the case of denoising when noise follows a Gaussian distribution. Both operations, smoothing noise and sharpening, have an opposite nature. Therefore, there are few approaches that simultaneously respond to both goals. We will review these methods and we will also provide a detailed study of the state-of-the-art methods that attack both problems in colour images, separately, The second author acknowledges the support of grant MTM2015-64373-P (MINECO/FEDER, UE) and the third author acknowledges the support of grant TEC2016-79884-C2-2-R (MICINN/FEDER).
DIGITAL.CSIC. Repositorio Institucional del CSIC
Publicación Artículo científico (JournalArticle)

Simulation Study of a Frame-Based Motion Correction Algorithm for Positron Emission Imaging

  • Espinos-Morato, Héctor
  • Cascales-Picó, David
  • Vergara, Marina
  • Hernández-Martínez, Ángel
  • Benlloch Baviera, José María
  • Rodríguez-Álvarez, María José
Positron emission tomography (PET) is a functional non-invasive imaging modality that uses radioactive substances (radiotracers) to measure changes in metabolic processes. Advances in scanner technology and data acquisition in the last decade have led to the development of more sophisticated PET devices with good spatial resolution (1-3 mm of full width at half maximum (FWHM)). However, there are involuntary motions produced by the patient inside the scanner that lead to image degradation and potentially to a misdiagnosis. The adverse effect of the motion in the reconstructed image increases as the spatial resolution of the current scanners continues improving. In order to correct this effect, motion correction techniques are becoming increasingly popular and further studied. This work presents a simulation study of an image motion correction using a frame-based algorithm. The method is able to cut the acquired data from the scanner in frames, taking into account the size of the object of study. This approach allows working with low statistical information without losing image quality. The frames are later registered using spatio-temporal registration developed in a multi-level way. To validate these results, several performance tests are applied to a set of simulated moving phantoms. The results obtained show that the method minimizes the intra-frame motion, improves the signal intensity over the background in comparison with other literature methods, produces excellent values of similarity with the ground-truth (static) image and is able to find a limit in the patient-injected dose when some prior knowledge of the lesion is present., This research has been co-financed by the Spanish Government Grants TEC2016-79884-C2, PID2019-107790RB-C22, and PEJ2018-002230-A-AR; the Generalitat Valenciana GJIDI/2018/A/040l and the PTA2019-017113-1/AEI/10.13039/501100011033; the European Union through the European Regional Development Fund (ERDF); and the European Research Council (ERC) under the European Union’s Horizon 2020 research and innovation program (Grant Agreement No. 695536)., Peer reviewed