Pasar al contenido principal

Resultados relacionados

Resultados totales (Incluyendo duplicados): 5
Encontrada(s) 1 página(s)

Zaguán. Repositorio Digital de la Universidad de Zaragoza
Publicación Artículo científico (JournalArticle)

Lighting-Induced Changes in Central and Peripheral Retinal Thickness and Shape after Short-Term Reading Tasks in Electronic Devices

  • Orduna-Hospital, Elvira
  • Ávila, Francisco J.
  • Fernández-Espinosa, Guisela
  • Sanchez-Cano, Ana
Background: To assess retinal and optical changes associated with near vision reading for different lighting conditions in electronic screens. Methods: Twenty-four young healthy subjects participated in the study; an iPad and an Ebook were chosen as stimuli for 5 min of reading task with different lighting conditions. Central and peripheral retinal thicknesses in the macular ETDRS areas by optical coherence tomography were analyzed. Results: Significant differences were found between basal retinal thickness and retinal thickness after reading with iPad and high illumination, in the N6 (p = 0.021) and I6 (p = 0.049) areas, and low illumination (S3: p = 0.008, N3: p = 0.018, I3: p = 0.021, N6: p = 0.018 and I6: p = 0.020), being thinner after reading. The same trend was observed after reading with an Ebook and high lighting in the N3 (p = 0.037) and N6 (p = 0.028). For low lighting conditions, only retinal thinning was observed. After reading, retinal shape analysis revealed significant changes from computed basal eccentricity for high lighting conditions only. At the periphery, those differences in eccentricity values were statistically significant for both lighting conditions. Conclusions: Young people can recover visual quality after 5 min of reading tasks at different lighting levels on electronic devices, while peripheral retinal expansion remains altered, especially at low lighting levels.
Zaguán. Repositorio Digital de la Universidad de Zaragoza
Publicación Artículo científico (JournalArticle)

Hess Lancaster screen test with eye tracker: an objective method for the measurement of binocular gaze direction

  • Orduna-Hospital, Elvira
  • Maurain-Orera, Luz
  • Lopez-de-la-Fuente, Carmen
  • Sanchez-Cano, Ana
Background: To objectively measure with an eye tracker both eye movement conjugacy and gaze direction in different positions when performing the Hess Lancaster Screen Test (HLST) in a sample of control subjects without binocular dysfunction and compare the results with those of the traditional subjective HLST performance. Methods: The sample was selected avoiding subjects who suffered from suppression of one of the two eyes, visual acuity less than 20/25 on the Snellen chart in each eye, strabismus, or any symptom of binocular dysfunction that could alter the results. While performing the HLST, the examiner wrote down each of the points on a template in a traditional way while the eye tracker (Tobii Pro Fusion, Tobii AB, Danderyd, Sweden), placed in front of the subject, took objective measurements of the position of both eyes at each point. Of the 29 subjects recruited in this study, 13 subjects between 18 and 27 years old underwent the complete optometric examination and the HLST wearing anaglyph glasses; meanwhile, 16 people were excluded because of binocular or accommodative dysfunctions or because they didn’t give reliable eye-tracking results. Additionally, a specific program called Etracker Parse Video (University of Zaragoza, Zaragoza, Spain) was developed to analyse the prismatic deviation between both eyes at each evaluated point. Results: Similar horizontal prismatic deviations of visual axes were obtained in the different gaze positions with the Maddox rod, the manually annotated HLST, and the eye-tracker measurement. Variations were found in the magnitude of the deviation between methods but not in the direction. On the other hand, vertical deviations were more difficult for the examiner to detect and quantify, especially those with small magnitudes; more exact values were obtained when measuring objectively with the eye tracker. Conclusion: The HLST is very useful and allows the amount of heterophoria or heterotropia to be recorded in the patient’s medical record in all the main gaze positions. This test is complementary; by itself, it is not diagnostic and does not replace a complete examination of binocular vision. The eye tracker is an objective method with which we can evaluate the HLST in patients with no binocular problems, obtaining more accurate results than when it is performed in the traditional manner.
Zaguán. Repositorio Digital de la Universidad de Zaragoza
Publicación Artículo científico (JournalArticle)

Eye-tracker study of the developmental eye movement test in young people without binocular dysfunctions

  • Orduna-Hospital, Elvira
  • Navarro-Marqués, Aitana
  • López-de-la-Fuente, Carmen
  • Sanchez-Cano, Ana
Background: The purpose of this study was to evaluate ocular motility in normal young adults when performing the Developmental Eye Movement (DEM) test using an infrared eye-tracker in a sample of young subjects without visual dysfunctions. Methods: An optometric evaluation was carried out on 52 participants with a mean age of 21.00 ± 3.22 years to verify they did not have any binocular dysfunction, by completing a computerized version of the DEM test while their eye movements were recorded with an eye-tracker. A custom-written software was developed to analyse some specific parameters of ocular motility while performing each subtest (Test A, Test B and Test C) of the complete DEM test. Results: The mean duration of the fixations was shorter in Test C (243.56 ± 46.18 s) than in Test A (493.52 ± 171.41 s) and Test B (484.20 ± 156.59 s). The mean adjusted horizontal (AdjHT: 35.24 ± 6.68 s) and vertical (VT: 33.58 ± 5.56 s) times were at the 45th and at the 40th percentile, respectively. In Test C, there was a high positive significant correlation between the saccadic speed (cc: 0.77; p < 0.001) and the saccadic length (cc: 0.74; p < 0.001) of both eyes. Conclusions: The eye-tracker is an objective method to evaluate the DEM test in subjects without binocular dysfunctions, measuring and quantifying ocular motility parameters that are impossible with the traditional subjective method. The eye movements of both eyes are conjugated in each subject, having saccades of the same length and speed.
Zaguán. Repositorio Digital de la Universidad de Zaragoza
Publicación Artículo científico (JournalArticle)

Optical and motor changes associated with lighting and near vision tasks in electronic devices

  • Orduna-Hospital, Elvira
  • Safarian Baloujeh, Ebrahim
  • Navarro, Rafael
  • Sanchez-Cano, Ana
Purpose:To assess optical and motor changes associated with near vision reading under different controlled lighting conditions performed with two different types of electronic screens. Methods: Twenty-four healthy subjects with a mean age of 22.9±2.3 years (18-33) participated in this study. An iPad and an e-ink reader were chosen to present calibrated text, and each task lasted 5 minutes evaluating both ambient illuminance level and luminance of the screens. Results:Eye-tracker data revealed a higher number of saccadic eye movements under minimum luminance than under maximum luminance. The results showed statistically significant differences between the iPad (p=0.016) and the e-ink reader (p=0.002). The length of saccades was also higher for the minimum luminance level for both devices: 6.2±2.8 mm and 8.2±4.2 mm (e-ink max vs min), 6.8±2.9 mm and 7.6±3.6 mm (iPad max vs min), and blinking rate increased significantly for lower lighting conditions. Conclusions: Performing reading tasks on electronic devices is highly influenced by both the configuration of the screens and the ambient lighting, meanwhile, low differences in visual quality that are transient in healthy young people, were found.
Zaguán. Repositorio Digital de la Universidad de Zaragoza
Publicación Artículo científico (JournalArticle)

Comparative Effects of Red and Blue LED Light on Melatonin Levels During Three-Hour Exposure in Healthy Adults

  • Sanchez-Cano, Ana
  • Luesma-Bartolomé, María José
  • Solanas, Estela
  • Orduna-Hospital, Elvira
Circadian rhythms, essential for regulating human physiology and behavior, are influenced by light exposure, particularly at night. This study examined the impact of red (631 nm) and blue (464 nm) LED light on melatonin secretion, a key circadian marker. Twelve participants aged 19–55 years were exposed to red and blue light for three hours (9:00 p.m.–midnight), with hourly saliva samples analyzed via ELISA to track melatonin levels. Initially, melatonin levels were comparable under both light conditions. After one hour, both lights suppressed melatonin, but differences emerged after two hours: blue light-maintained suppression, with levels at 7.5 pg/mL, while red light allowed recovery to 26.0 pg/mL (p = 0.019). This pattern persisted at the third hour. Blue light had stronger suppression effects, particularly in younger participants and men. These results underscore blue light’s disruptive effects on circadian health and highlight red light as a less disruptive alternative for nighttime environments.