Pasar al contenido principal

ENVEJECIMIENTO DEL SISTEMA OPTICO DEL OJO:DESARROLLO DE INSTRUMENTACION, MODELOS OPTICOS Y ESTUDIOS EXPERIMENTALES

PID2019-107058RB-I00

•
Nombre agencia financiadora Agencia Estatal de Investigación
Acrónimo agencia financiadora AEI
Programa Programa Estatal de I+D+i Orientado a los Retos de la Sociedad
Convocatoria Proyectos de I+D+i (Generación de Conocimiento y Retos Investigación)
Año convocatoria 2019
Plan Estatal 2017-2020 Plan Estatal de Investigación Científica y Técnica y de Innovación
Centro beneficiario UNIVERSIDAD DE ZARAGOZA

Resultados relacionados

Resultados totales (Incluyendo duplicados): 22
Encontrada(s) 1 página(s)

Academica-e. Repositorio Institucional de la Universidad Pública de Navarra
Publicación Artículo científico (JournalArticle)

Analytical ray transfer matrix for the crystalline lens

  • Navarro, Rafael
  • Lockett-Ruiz, Verónica
  • López García, José Luis
We present the formulation of a paraxial ray transfer or ABCD matrix for onion-type GRIN lenses. In GRIN lenses, each iso-indicial surface (IIS) can be considered a refracting optical surface. If each IIS is a shell or layer, the ABCD matrix of a GRIN lens is computed by multiplying a typically high number of translation and refraction matrices corresponding to the K layers inside the lens. Using a differential approximation for the layer thickness, this matrix product becomes a sum. The elements A, B, C, and D of the approximated GRIN ray transfer matrix can be calculated by integrating the elements of a single-layer matrix. This ABCD matrix differs from a homogeneous lens matrix in only one integration term in element C, corresponding to the GRIN contribution to the lens power. Thus the total GRIN lens power is the sum of the homogeneous lens power and the GRIN contribution, which offers a compact and simple expression for the ABDC matrix. We then apply this formulation to the crystalline lens and implement both numerical and analytical integration procedures to obtain the GRIN lens power. The analytical approximation provides an accurate solution in terms of Gaussian hypergeometric functions. Last, we compare our numerical and analytical procedures with published ABCD matrix methods in the literature, and analyze the effect of the iso-indicial surface’s conic constant (Q) and inner curvature gradient (G) on the lens power for different lens models., Ministerio de Ciencia e Innovación (PID2019-405 107058RB-100, PGC2018-095795B-I00); HORIZON EUROPE Marie Sklodowska-Curie Actions (956720).
DIGITAL.CSIC. Repositorio Institucional del CSIC
Publicación Artículo científico (JournalArticle)

GRINCU lens with conicoid iso-indicial surfaces: application for modeling the crystalline lens

  • Navarro, Rafael
  • Baquedano, Sergio
  • Sánchez-Cano, Ana I.
We introduce a new type of lens with two gradients of refractive index (GRIN) and of curvature (GRCU) of iso-indicial surfaces, i.e., GRINCU. The inner structure of the lens resembles that of an onion. Each layer is a meniscus lens with infinitesimal thickness, which coincides with an iso-indicial surface characterized by a conicoid shape and a constant refractive index. The internal distribution automatically adapts to the external geometry. Here, we consider the simplest case of a constant gradient of the curvature radius –G, which indicates a linear decrease as we move along the optical axis. The formulation of this type of lens is presented, including its generalization to nonrotationally symmetric conicoid surfaces. The formulation is then applied to model the crystalline lens; the code corresponding to the numerical computation of the 3D refractive index distribution as well as its gradient is provided as a supplementary file. Finally, we confirmed a refractive power increase of nearly 14% when G changes from 0 to 3., Ministerio de Ciencia, Innovación y Universidades (PID2019-107058RB-I00)., Peer reviewed
DIGITAL.CSIC. Repositorio Institucional del CSIC
Publicación Artículo científico (JournalArticle)

Analytical ray transfer matrix for the crystalline lens

  • Navarro, Rafael
  • Lockett-Ruiz, Veronica
  • López, José L.
We present the formulation of a paraxial ray transfer or ABCD matrix for onion-type GRIN lenses. In GRIN lenses, each iso-indicial surface (IIS) can be considered a refracting optical surface. If each IIS is a shell or layer, the ABCD matrix of a GRIN lens is computed by multiplying a typically high number of translation and refraction matrices corresponding to the K layers inside the lens. Using a differential approximation for the layer thickness, this matrix product becomes a sum. The elements A, B, C, and D of the approximated GRIN ray transfer matrix can be calculated by integrating the elements of a single-layer matrix. This ABCD matrix differs from a homogeneous lens matrix in only one integration term in element C, corresponding to the GRIN contribution to the lens power. Thus the total GRIN lens power is the sum of the homogeneous lens power and the GRIN contribution, which offers a compact and simple expression for the ABDC matrix. We then apply this formulation to the crystalline lens and implement both numerical and analytical integration procedures to obtain the GRIN lens power. The analytical approximation provides an accurate solution in terms of Gaussian hypergeometric functions. Last, we compare our numerical and analytical procedures with published ABCD matrix methods in the literature, and analyze the effect of the iso-indicial surface’s conic constant (Q) and inner curvature gradient (G) on the lens power for different lens models., Ministerio de Ciencia e Innovación (PID2019-405 107058RB-100, PGC2018-095795B-I00); HORIZON EUROPE Marie Sklodowska-Curie Actions (956720)., Peer reviewed
DIGITAL.CSIC. Repositorio Institucional del CSIC
Publicación Artículo científico (JournalArticle)

Geometric optical transfer function and pupil sampling patterns

  • Díaz, José A.
  • Navarro, Rafael
We have studied several pupil sampling patterns for calculating the optical transfer function corresponding to actual non-diffraction limited optical imaging systems, in the low range of spatial frequencies, i.e., where the geometric approach is valid, by means of the Fourier Transform of the spot diagram. Then, we have compared the diffraction and the geometric optical transfer functions to ascertain if there is a sampling pattern that accurately calculates the latter within a 5% of difference, and having less number of sampling points. The results show that, overall, the non redundant spiral pupil sampling provides the best choice. This could be valuable when optimizing or characterizing optical imaging systems in the non-diffraction limited range by harnessing raytracing., The authors acknowledge the support to this work given by the Ministerio de Ciencia e Innovación y Universidades of Spain (MICIN) , grant number PID2019-107058RB-100., Funding for open access charge: Universidad de Granada / CBUA., Peer reviewed
DIGITAL.CSIC. Repositorio Institucional del CSIC
Publicación Artículo científico (JournalArticle)

Optical and motor changes associated with lighting and near vision tasks in electronic devices

  • Orduna-Hospital, Elvira
  • Safarian Baloujeh, Ebrahim
  • Navarro, Rafael
  • Sánchez-Cano, Ana I.
[Purpose]: To assess optical and motor changes associated with near vision reading under different controlled lighting conditions performed with two different types of electronic screens., [Methods]: Twenty-four healthy subjects with a mean age of 22.9±2.3 years (18-33) participated in this study. An iPad and an e-ink reader were chosen to present calibrated text, and each task lasted 5 minutes evaluating both ambient illuminance level and luminance of the screens., [Results]: Eye-tracker data revealed a higher number of saccadic eye movements under minimum luminance than under maximum luminance. The results showed statistically significant differences between the iPad (p=0.016) and the e-ink reader (p=0.002). The length of saccades was also higher for the minimum luminance level for both devices: 6.2±2.8 mm and 8.2±4.2 mm (e-ink max vs min), 6.8±2.9 mm and 7.6±3.6 mm (iPad max vs min), and blinking rate increased significantly for lower lighting conditions., [Conclusions]: Performing reading tasks on electronic devices is highly influenced by both the configuration of the screens and the ambient lighting, meanwhile, low differences in visual quality that are transient in healthy young people, were found., This research was funded by the Agencia Estatal de Investigación, Ministerio de Ciencia e Innovación of the Spanish Government (Grant PID2019-107058RB-I00 funded by MCIN/AEI/10.13039/501100011033), the European Union’s Horizon 2020 research and innovation programme under the Marie Skłodowska-Curie grant agreement No 956720, Gobierno de Aragón-Departamento de Ciencia, Universidad y Sociedad del Conocimiento-No LMP39_21, Fundación Ibercaja and University of Zaragoza No JIUZ-2021-CIE-03 and Ayudas para la adquisición de infraestructura de investigación (Modalidad A). Contrato Programa Plan De Inversiones e Investigación Gobierno de Aragón-Universidad de Zaragoza. Fondos Feder-2020., Peer reviewed
DIGITAL.CSIC. Repositorio Institucional del CSIC
Publicación Artículo científico (JournalArticle)

Intracapsular accommodation mechanism in terms of lens curvature gradient

  • Lockett-Ruiz, Veronica
  • Navarro, Rafael
  • López-Gil, Norberto
The intracapsular accommodation mechanism (IAM) may be understood as an increase in the lens equivalent refractive index as the eye accommodates. Our goal was to evaluate the existence of an IAM by analysing observed changes in the inner curvature gradient of the lens. To this end, we fitted a gradient index and curvature lens model to published experimental data on external and nucleus geometry changes during accommodation. For each case analysed, we computed the refractive power and equivalent index for each accommodative state using a ray transfer matrix. All data sets showed an increase in the effective refractive index, indicating a positive IAM, which was stronger for older lenses. These results suggest a strong dependence of the lens equivalent refractive index on the inner curvature gradient., Funded by the European Union's Horizon 2020 research and innovation programme under the Marie Skłodowska-Curie grant agreement No 956720 and by the Agencia Estatal de Investigación, Ministerio de Ciencia e Innovación y Universidades of Spain (MICIN), grant number PID2019-107058RB-I00/AEI/10.13039/501100011033CONFLICTSOFINTEREST., Peer reviewed
Zaguán. Repositorio Digital de la Universidad de Zaragoza
Publicación Artículo científico (JournalArticle)

Optimization of lighting projects including photopic and circadian criteria: A simplified action protocol

  • Sánchez-Cano, A.
  • Aporta, J.
Lighting projects that consider parameters related to circadian light remain rare. Using controlled lighting on both photopic and melanopic levels, this study aims to simplify the design of circadian lighting projects based on traditional photometric parameters and calculations. A real classroom is used to illustrate the behavior of horizontal (visual stimuli) and vertical (circadian contribution) illuminances under different design parameters, such as the varied reflectance of walls, ceiling, and floor; varied spatial distribution curves, including the number and position of luminaires; and across the spectral power distribution of a variety of LEDs. In this work, we seek to clarify and simplify to the greatest possible extent the meaning and scope of various lighting standards while establishing simple protocols. Our results will enable designers to carry out optimized lighting projects from both the photometric and circadian perspectives.
Zaguán. Repositorio Digital de la Universidad de Zaragoza
Publicación Artículo científico (JournalArticle)

Evaluation of Visual and Nonvisual Levels of Daylight from Spectral Power Distributions Considering Orientation and Seasonality

  • Ezpeleta, Silvia
  • Orduna-Hospital, Elvira
  • Aporta, Justiniano
  • Luesma, María José
  • Pinilla, Isabel
  • Sánchez-Cano, Ana
The evaluation of both visual and nonvisual effects from the spectral power distribution (SPD) of outdoor light is critical in lighting design. The dome-light SPD characteristically changes continuously depending on the seasonality, orientation, altitude of the sun or hour of the day. Traditional photopic parameters, such as the illuminance, luminance or correlated colour temperature (CCT), have been widely studied, but presently, there is no melanopic measurement or evaluation method. This article discusses the processes involved in establishing a simple method to determine the SPD of daylight and solar radiation over the skydome in a location to accurately account for the effects of both photopic and circadian levels around a location. Once per month for one year, natural daylight was spectrally measured in the city of Zaragoza (Spain); radiometric and photometric characteristics were analysed by season; and circadian effects were calculated in terms of standard parameters described by the Commission International de l\u2019Eclairage (CIE), factors recommended by normative and scientific backgrounds. Finally, we suggest that the best parameter is the melanopic versus photopic irradiance ratio, which achieves reliable results at simplifying and correlating calculations.
Zaguán. Repositorio Digital de la Universidad de Zaragoza
Publicación Artículo científico (JournalArticle)

Analysis of Photopic and Melanopic Lighting in Teaching Environments

  • Ezpeleta, Silvia
  • Orduna-Hospital, Elvira
  • Solana, Teresa
  • Aporta, Justiniano
  • Pinilla, Isabel
  • Sánchez-Cano, Ana
Daylight and lighting seem to be a key tool for people\u2019s well-being, however, there are no specific and agreed recommendations that address both photopic and melanopic aspects in educational environments. The present work analyzed melanopic light in four teaching environments considering photopic indoor lighting, daylight depending on the window orientation, location of the observer in the room, and their line of view. The façade direction, daylight at 11.00 a.m. for six months from October to March, and the characteristics of each classroom, such as reflectance of the surfaces, location of the luminaires and their spectral and spatial power distributions, or calculation points affecting the melanopic light reaching the corneal vertical plane of a hypothetical control observer were studied. For this evaluation, classrooms were experimentally treated and simulated using DialuxEvo software, and the computer-generated values resembled the experimental values. Once the study was performed, an improvement proposal, based on LED lighting, was made to optimize the classroom lighting considering the melanopic requirements, which we ensured that users who passed through these classrooms had an adequate amount light at any time of the day. Our results simplify to the greatest lighting projects and enable designers to carry out optimized evaluations of specific environments from both the photometric and circadian perspectives.
Zaguán. Repositorio Digital de la Universidad de Zaragoza
Publicación Artículo científico (JournalArticle)

Analytical ray transfer matrix for the crystalline lens

  • Navarro, Rafael
  • Lockett-Ruiz, Veronica
  • López, José L.
We present the formulation of a paraxial ray transfer or ABCD matrix for onion-type GRIN lenses. In GRIN lenses, each iso-indicial surface (IIS) can be considered a refracting optical surface. If each IIS is a shell or layer, the ABCD matrix of a GRIN lens is computed by multiplying a typically high number of translation and refraction matrices corresponding to the K layers inside the lens. Using a differential approximation for the layer thickness, this matrix product becomes a sum. The elements A, B, C, and D of the approximated GRIN ray transfer matrix can be calculated by integrating the elements of a single-layer matrix. This ABCD matrix differs from a homogeneous lens matrix in only one integration term in element C, corresponding to the GRIN contribution to the lens power. Thus the total GRIN lens power is the sum of the homogeneous lens power and the GRIN contribution, which offers a compact and simple expression for the ABDC matrix. We then apply this formulation to the crystalline lens and implement both numerical and analytical integration procedures to obtain the GRIN lens power. The analytical approximation provides an accurate solution in terms of Gaussian hypergeometric functions. Last, we compare our numerical and analytical procedures with published ABCD matrix methods in the literature, and analyze the effect of the iso-indicial surface’s conic constant (Q) and inner curvature gradient (G) on the lens power for different lens models.
Zaguán. Repositorio Digital de la Universidad de Zaragoza
Publicación Artículo científico (JournalArticle)

Hess Lancaster screen test with eye tracker: an objective method for the measurement of binocular gaze direction

  • Orduna-Hospital, Elvira
  • Maurain-Orera, Luz
  • Lopez-de-la-Fuente, Carmen
  • Sanchez-Cano, Ana
Background: To objectively measure with an eye tracker both eye movement conjugacy and gaze direction in different positions when performing the Hess Lancaster Screen Test (HLST) in a sample of control subjects without binocular dysfunction and compare the results with those of the traditional subjective HLST performance. Methods: The sample was selected avoiding subjects who suffered from suppression of one of the two eyes, visual acuity less than 20/25 on the Snellen chart in each eye, strabismus, or any symptom of binocular dysfunction that could alter the results. While performing the HLST, the examiner wrote down each of the points on a template in a traditional way while the eye tracker (Tobii Pro Fusion, Tobii AB, Danderyd, Sweden), placed in front of the subject, took objective measurements of the position of both eyes at each point. Of the 29 subjects recruited in this study, 13 subjects between 18 and 27 years old underwent the complete optometric examination and the HLST wearing anaglyph glasses; meanwhile, 16 people were excluded because of binocular or accommodative dysfunctions or because they didn’t give reliable eye-tracking results. Additionally, a specific program called Etracker Parse Video (University of Zaragoza, Zaragoza, Spain) was developed to analyse the prismatic deviation between both eyes at each evaluated point. Results: Similar horizontal prismatic deviations of visual axes were obtained in the different gaze positions with the Maddox rod, the manually annotated HLST, and the eye-tracker measurement. Variations were found in the magnitude of the deviation between methods but not in the direction. On the other hand, vertical deviations were more difficult for the examiner to detect and quantify, especially those with small magnitudes; more exact values were obtained when measuring objectively with the eye tracker. Conclusion: The HLST is very useful and allows the amount of heterophoria or heterotropia to be recorded in the patient’s medical record in all the main gaze positions. This test is complementary; by itself, it is not diagnostic and does not replace a complete examination of binocular vision. The eye tracker is an objective method with which we can evaluate the HLST in patients with no binocular problems, obtaining more accurate results than when it is performed in the traditional manner.
Zaguán. Repositorio Digital de la Universidad de Zaragoza
Publicación Artículo científico (JournalArticle)

Method to calculate melanopic light reaching the retina depending on the optical density of an aging crystalline lens

  • Sanchez-Cano, A.
  • Orduna-Hospital, E.
  • Fernández-Espinosa, G.
  • Aporta, J.
Lighting studies that take into account the age of the inhabitants of an area and are related to circadian light are difficult to find. This study aims to simplify a method to approximately compute the circadian light reaching the retina based on photopic illuminance reaching the corneal plane and considering the optical density of an aging crystalline lens. As an example of this proposed method, calculations were performed with both the D65 and A standard illuminants, showing how the spectral power distribution is modified by the optical density of the crystalline lens, mainly at short wavelengths. Due to these selective wavelength absorptions of the aged lens, a significant variation in the level of daylight equivalent melanopic illuminance (EDI) is present in the retina. With levels of 200 lux at the corneal plane, these variations ranged from 204 EDI lux to 178 EDI lux for the D65 standard illuminant, and from 99 EDI lux to 101 EDI lux for the A standard illuminant for observers aged 10 and 90, respectively. In this work, we aimed to simplify the greatest possible level of calculation of melanopic light, while describing simple protocols that are easy to translate into practice. Our results will allow researchers to carry out optimized lighting designs from both the photometric and circadian perspectives considering the optical density of an aging lens.
Zaguán. Repositorio Digital de la Universidad de Zaragoza
Publicación Artículo científico (JournalArticle)

Eye-tracker study of the developmental eye movement test in young people without binocular dysfunctions

  • Orduna-Hospital, Elvira
  • Navarro-Marqués, Aitana
  • López-de-la-Fuente, Carmen
  • Sanchez-Cano, Ana
Background: The purpose of this study was to evaluate ocular motility in normal young adults when performing the Developmental Eye Movement (DEM) test using an infrared eye-tracker in a sample of young subjects without visual dysfunctions. Methods: An optometric evaluation was carried out on 52 participants with a mean age of 21.00 ± 3.22 years to verify they did not have any binocular dysfunction, by completing a computerized version of the DEM test while their eye movements were recorded with an eye-tracker. A custom-written software was developed to analyse some specific parameters of ocular motility while performing each subtest (Test A, Test B and Test C) of the complete DEM test. Results: The mean duration of the fixations was shorter in Test C (243.56 ± 46.18 s) than in Test A (493.52 ± 171.41 s) and Test B (484.20 ± 156.59 s). The mean adjusted horizontal (AdjHT: 35.24 ± 6.68 s) and vertical (VT: 33.58 ± 5.56 s) times were at the 45th and at the 40th percentile, respectively. In Test C, there was a high positive significant correlation between the saccadic speed (cc: 0.77; p < 0.001) and the saccadic length (cc: 0.74; p < 0.001) of both eyes. Conclusions: The eye-tracker is an objective method to evaluate the DEM test in subjects without binocular dysfunctions, measuring and quantifying ocular motility parameters that are impossible with the traditional subjective method. The eye movements of both eyes are conjugated in each subject, having saccades of the same length and speed.
Zaguán. Repositorio Digital de la Universidad de Zaragoza
Publicación Artículo científico (JournalArticle)

Geometric optical transfer function and pupil sampling patterns

  • Díaz, J. A.
  • Navarro, R.
We have studied several pupil sampling patterns for calculating the optical transfer function corresponding to actual non-diffraction limited optical imaging systems, in the low range of spatial frequencies, i.e., where the geometric approach is valid, by means of the Fourier Transform of the spot diagram. Then, we have compared the diffraction and the geometric optical transfer functions to ascertain if there is a sampling pattern that accurately calculates the latter within a 5% of difference, and having less number of sampling points. The results show that, overall, the non redundant spiral pupil sampling provides the best choice. This could be valuable when optimizing or characterizing optical imaging systems in the non-diffraction limited range by harnessing raytracing,
Zaguán. Repositorio Digital de la Universidad de Zaragoza
Publicación Artículo científico (JournalArticle)

Optical and motor changes associated with lighting and near vision tasks in electronic devices

  • Orduna-Hospital, Elvira
  • Safarian Baloujeh, Ebrahim
  • Navarro, Rafael
  • Sanchez-Cano, Ana
Purpose:To assess optical and motor changes associated with near vision reading under different controlled lighting conditions performed with two different types of electronic screens. Methods: Twenty-four healthy subjects with a mean age of 22.9±2.3 years (18-33) participated in this study. An iPad and an e-ink reader were chosen to present calibrated text, and each task lasted 5 minutes evaluating both ambient illuminance level and luminance of the screens. Results:Eye-tracker data revealed a higher number of saccadic eye movements under minimum luminance than under maximum luminance. The results showed statistically significant differences between the iPad (p=0.016) and the e-ink reader (p=0.002). The length of saccades was also higher for the minimum luminance level for both devices: 6.2±2.8 mm and 8.2±4.2 mm (e-ink max vs min), 6.8±2.9 mm and 7.6±3.6 mm (iPad max vs min), and blinking rate increased significantly for lower lighting conditions. Conclusions: Performing reading tasks on electronic devices is highly influenced by both the configuration of the screens and the ambient lighting, meanwhile, low differences in visual quality that are transient in healthy young people, were found.
Zaguán. Repositorio Digital de la Universidad de Zaragoza
Publicación Artículo científico (JournalArticle)

Visual Quality, Motility Behavior, and Retinal Changes Associated with Reading Tasks Performed on Electronic Devices

  • Orduna-Hospital, Elvira
  • Munarriz-Escribano, María
  • Sanchez-Cano, Ana
Background: The purpose of this study was to objectively evaluate visual discomfort using an eye tracker and aberrometer after a 21-min reading session on an iPad and an Ebook. Additionally, retinal changes were analyzed using optical coherence tomography (OCT). Methods: A total of 31 young subjects (24 ± 4 years) participated in this study. They read for 21 min on an Ebook and for another 21 min on an iPad under controlled lighting conditions while their eye movements were monitored using an eye tracker. Aberrometry and retinal OCT measurements were taken before and after each reading session. Parameters such as pupil diameter, fixations, saccades, blinks, total aberration, high-order aberration, low-order aberration, and central and peripheral retinal thickness in the nine early treatment diabetic retinopathy study (ETDRS) areas were measured for each reading situation. Statistical analysis was performed on the collected data. Results: No statistically significant differences (p > 0.05) between the two devices were observed in terms of the different types of eye movements or the changes in retinal thickness. However, the aberrometric analysis showed variations in post-reading situations depending on the device used. Conclusion: Reading speed and visual discomfort resulting from electronic device usage can be objectively assessed using an eye tracker and aberrometer. Additionally, changes found in central and peripheral retinal thickness between the two devices and the baseline measurements were not significant and remained relatively stable.
Zaguán. Repositorio Digital de la Universidad de Zaragoza
Publicación Artículo científico (JournalArticle)

Ocular motility patterns in intellectual disability: insights from the developmental eye movement test

  • Orduna-Hospital, Elvira
  • Hernández-Aranda, Diego
  • Sánchez-Cano, Ana
Purpose: To measure the ocular motility parameters of the Developmental Eye Movement (DEM) test objectively, with an eye tracker in subjects with intellectual disability (ID). Methods: The DEM test was performed on 45 subjects with ID, while their eye movements were recorded with an eye tracker. Some objective parameters of ocular motility were obtained through each subtest (A, B, and C) of the full DEM test. Results: There was a significant positive correlation between the saccadic speed (cc: 0.537; p = 0.001) and length (cc: 0.368; p = 0.030) of both eyes for the same subject. People with a higher percentage of ID exhibited a greater number of fixations, saccades, and errors, and took longer to perform the DEM test than those with a lower ID percentage, who had greater numbers of these parameters than subjects without ID. Subjects without ID exhibited faster saccades, with a higher amplitude, than subjects with ID. Conclusions: The eye tracker quantifies ocular motility parameters involved in the DEM test in subjects with ID. Both eyes’ movements in subjects with ID were conjugated, exhibiting saccades of the same length and speed. All parameters were different in subjects with ID compared to those in subjects without ID, so normative tables specifically for subjects with ID are necessary.
Zaguán. Repositorio Digital de la Universidad de Zaragoza
Publicación Artículo científico (JournalArticle)

Adaptive Illuminance Effects on Retinal Morphology and Refraction: A Comprehensive Study of Night Myopia

  • Orduna-Hospital, Elvira
  • Crespo-Castan, Cynthia
  • Ávila, Francisco J.
  • Sanchez-Cano, Ana
Background: We aimed to study the optical and retinal modifications that occur after adapting to different lighting conditions including photopic, mesopic, scotopic, blue light and red light conditions. Methods: Thirty young healthy subjects with a mean age of 23.57 ± 3.45 years were involved in the study (both eyes included). They underwent aberrometry and optical coherence tomography at both the central and peripheral retina with the 3 × 3 mm2 macular cube protocol before starting adaptation to the illuminations (baseline) and after remaining for 5 min under the five different lighting conditions inside a controlled lighting cabinet. Results: Significant myopization (p = 0.002) was observed under scotopic and mesopic lighting conditions, while hypermetropization occurred under the influence of blue LED light. In the central retina, a significant thickening of the inner temporal (p = 0.025) and outer inferior (p = 0.021) areas was observed in the scotopic area, and the thickening increased even more under blue and red light. The mean central thickness decreased significantly under photopic lighting conditions (p = 0.038). There was an increase in the mean volume of the central retinal area with red light and a reduction in the volume under photopic lighting (p = 0.039). In the peripheral retina, no significant thickness changes were observed after adapting to any of the lighting conditions (p > 0.05). Regarding morphological changes, a significant increase in retinal eccentricity (p = 0.045) and the shape factor (p = 0.036) was found. In addition, a significant correlation was found only between the eccentricity and volume of the central retina in scotopic conditions (r = −0.265; p = 0.041), meaning that a higher volume was associated with lower retinal eccentricity. Conclusions: When exposed to different lighting conditions, the retina changes in shape, and ocular refraction is modified to adapt to each condition, revealing the phenomenon of night myopia when transitioning from photopic to scotopic regimes.
Zaguán. Repositorio Digital de la Universidad de Zaragoza
Publicación Artículo científico (JournalArticle)

Intracapsular accommodation mechanism in terms of lens curvature gradient

  • Lockett-Ruiz, Veronica
  • Navarro, Rafael
  • López-Gil, Norberto
The intracapsular accommodation mechanism (IAM) may be understood as an increase in the lens equivalent refractive index as the eye accommodates. Our goal was to evaluate the existence of an IAM by analysing observed changes in the inner curvature gradient of the lens. To this end, we fitted a gradient index and curvature lens model to published experimental data on external and nucleus geometry changes during accommodation. For each case analysed, we computed the refractive power and equivalent index for each accommodative state using a ray transfer matrix. All data sets showed an increase in the effective refractive index, indicating a positive IAM, which was stronger for older lenses. These results suggest a strong dependence of the lens equivalent refractive index on the inner curvature gradient.
Zaguán. Repositorio Digital de la Universidad de Zaragoza
Publicación Artículo científico (JournalArticle)

Comparison of two visual-verbal tests of ocular motility using an eye-tracker

  • López-de-la-Fuente, Carmen
  • Saz-Onrubia, Elena
  • Orduna-Hospital, Elvira
  • Sánchez-Cano, Ana
Purpose This study aims to compare eye movements monitored with an eye tracker during two visuo-verbal tests for assessing ocular motility. The study explores the potential of digital assessment and eye tracking technology in enhancing the understanding of ocular motility during these tests. Methods 47 healthy participants were included (20 males, 27 females), with a mean age of 21.34±1.77 years. The participants underwent optometric examinations to ensure visual health and exclude any dysfunctions or pathologies. The experimental protocol involved the digitized versions of the DEM and King-Devick tests, monitored with an eye tracker. Results The vertical subtests of DEM test showed fewer saccades, longer fixation durations, smaller saccade amplitudes, and slower saccade speeds compared to the horizontal subtest. The King-Devick test exhibited comparable fixation and saccade numbers, while fixation duration slightly increased with test difficulty. Statistically significant differences were found between the tests, but a positive correlation was observed. Conclusions Statistically significant differences were observed between the DEM and King-Devick tests, indicating that they measure similar aspects but are not interchangeable. The DEM test offers more comprehensive information with vertical saccade assessment. Test duration correlates positively with saccade and fixation count, fixation duration, and saccade speed.
Zaguán. Repositorio Digital de la Universidad de Zaragoza
Publicación Artículo científico (JournalArticle)

GRINCU lens with conicoid iso-indicial surfaces: application for modeling the crystalline lens

  • Navarro, Rafael
  • Baquedano, Sergio
  • Sanchez-Cano, Ana I.
We introduce a new type of lens with two gradients of refractive index (GRIN) and of curvature (GRCU) of iso-indicial surfaces, i.e., GRINCU. The inner structure of the lens resembles that of an onion. Each layer is a meniscus lens with infinitesimal thickness, which coincides with an iso-indicial surface characterized by a conicoid shape and a constant refractive index. The internal distribution automatically adapts to the external geometry. Here, we consider the simplest case of a constant gradient of the curvature radius -G, which indicates a linear decrease as we move along the optical axis. The formulation of this type of lens is presented, including its generalization to nonrotationally symmetric conicoid surfaces. The formulation is then applied to model the crystalline lens; the code corresponding to the numerical computation of the 3D refractive index distribution as well as its gradient is provided as a supplementary file. Finally, we confirmed a refractive power increase of nearly 14% when G changes from 0 to 3.
Zaguán. Repositorio Digital de la Universidad de Zaragoza
Publicación Artículo científico (JournalArticle)

Photometric and colorimetric evaluation of phototherapy instruments for syntonic treatment of visual anomalies

  • López de la Fuente, Carmen
  • Sánchez-Cano, Ana Isabel
Significance: Ocular light exposure therapy has been used in optometric therapies to improve binocular anomalies such as accommodative or vergence dysfunctions, amblyopia therapy or to increase the visual field. Currently, syntonic phototherapy is used worldwide by behavioral optometrists, vision trainers, or occupational therapists, among others, although these treatments are supported by only a few research studies that lack consensus on the efficacy of this approach. PURPOSE: In this article, we highlight the optical characteristics of lamps without evaluating the efficacy of their use in optometric procedures.Methods: Our work analyzes four devices often used in clinical practice in terms of spectral power distribution, illuminance levels at the corneal plane, and both theoretical photopic and melanopic contributions to the visual system. Results: First, illuminance levels reaching the corneal plane depend on the characteristics of each lamp and their distance from where the eye should be positioned; for example, delta-theta filter photopic illuminance is 13.1, 93.7, 22.7, or 41.6 lux with the four evaluated devices. Second, filters or modes named the same differ in terms of their spectral power distribution. Third, substantial difference in color appearance has been found among the same configurations.Conclusions: The spectral and iluminance characteristics of syntonic systems used for vision therapy vary widely, including variations among filters with the same identifying characteristics. This provides significant sources of variability, which limit the ability to conduct evidence-based medicine clinical trials to assess the true efficacy of syntonic therapy. This study furthers our knowledge of syntonic phototherapy from a technical perspective; however, longitudinal research examining patients' evolution pre-lighting and post-lighting treatments is required to justify and understand the effects of light exposure and its impact on optometric and ocular parameters more clearly.