DISEÑO INTEGRAL Y FABRICACION ADITIVA DE IMPLANTES POLIMERICOS PATIENT-SPECIFIC

PID2020-112628RA-I00

•
Nombre agencia financiadora Agencia Estatal de Investigación
Acrónimo agencia financiadora AEI
Programa Programa Estatal de I+D+i Orientado a los Retos de la Sociedad
Convocatoria Proyectos de I+D+i (Generación de Conocimiento y Retos Investigación)
Año convocatoria 2020
Plan Estatal 2017-2020 Plan Estatal de Investigación Científica y Técnica y de Innovación
Centro beneficiario UNIVERSIDAD CARLOS III DE MADRID

Resultados relacionados

Resultados totales (Incluyendo duplicados): 9
Encontrada(s) 1 página(s)

RiuNet. Repositorio Institucional de la Universitat Politécnica de Valéncia
Publicación Artículo científico (JournalArticle)

Estimation and validation of elastic constants in fused filament fabrication 3D printing: From mesoscale to macroscale

  • Arias-Blanco, Adrián
  • Álvarez-Blanco, M.
  • Marco, Miguel
  • Belda Ricardo|||0000-0003-3913-5773
[EN] Evaluating the mechanical properties of 3D-printed parts is a cumbersome task. This study poses an approach based on computational homogenization to estimate the elastic constants of fused filament fabrication 3D-printed parts. A whole methodology for characterization and experimental validation is necessary to improve finite element numerical models. Samples are characterized both mechanically and geometrically. To improve the characterization, novel algorithms based on micro-computed tomography images and image segmentation techniques are implemented. Thereafter, elastic constants are estimated, informed by the characterization results. The method¿s effectiveness is assessed through a deep comparison, based on the digital image correlation technique, between different experimental samples and finite element models. Results show that the numerical estimation provided in this work is accurate enough to develop realistic finite element models, including anisotropy of the structures. However, defects and voids developed during 3D printing are an important source of error for these numerical models. This work provides an estimation and validation of elastic constants in 3D-printed parts, including geometrical characterization, numerical homogenization and experimental validation. The results of this work provide valuable information encompassing techniques to improve the characterization of 3D-printed parts, tendencies on elastic constants, and main sources of error., The authors gratefully acknowledge the funding support received from the Spanish Ministerio de Ciencia e Innovación for funding the project PID2020-112628RA-I00/AEI/10.13039/501100011033.
RiuNet. Repositorio Institucional de la Universitat Politécnica de Valéncia
Publicación Artículo científico (JournalArticle)

Design and mechanics of stackable auxetic S-shaped structures

  • Rufo-Martin, Celia
  • Diaz-Alvarez, Jose
  • Miguelez, Maria Henar
  • Youssef, George
  • Infante-García, Diego|||0000-0001-6010-2031
[EN] The emerging auxetic lattices, driven by contemporary advancements in additive manufacturing, have garnered significant attention, with an emphasis on improving structural performance and energy absorption efficiencies while mitigating the contributions of material nonlinearities and instabilities. This research advances the state of the art of thin-strut auxetic structures by introducing a stacking schema to realize 3D S-shaped polystructures with rigid-body motion-dominated deformation, spatial symmetry, and persistent auxeticity. Several generations of these polystructures were 3D printed using vat photopolymerization with varying strut thickness ranging from 1 mm to 3 mm. The additively manufactured structures were mechanically tested under quasi-static and impact loading scenarios, providing physical evidence for the foreseen structural behaviors discussed above. The polystructures yielded load-bearing-to-mass ratios of 4.6 kN/kg, 7.6 kN/kg, and 12.3 kN/kg for t1, t2, and t3, respectively, with less than 10 g of weight, a result of the rigid body motion and the asymmetric rotation of the polystructure beams. Additionally, the impact response highlighted a structure-to-material transition, resulting in similar force maxima for t1 and t2, with 9 and 10 N (structure-dominated), whereas t3 reported a force of up to 49 N (material-dominated). However, irrespective of the strut thickness, the negative Poisson's ratio remained nearly unchanged (-0.22 +/- 0.02), exemplifying the importance of the structural mechanics substantiated by the specific topological design of S-shaped unit cells. The research findings paved the way for the translational potential of S-shaped polystructures in practical applications for mitigating impact, including civilian and military loading conditions., The authors acknowledge the support of the National Science Foundation under Grant No. 2035663 (G.Y.) . Funding from the U.S. Department of Defense (W911NF1410039, W911NF1810477, W911NF2310150, and N00174-23-1-0009) is also acknowledged. The authors are also grateful for internal funding from San Diego State University and Universidad Carlos III de Madrid. In particular, this work was supported by the MCIN/AEI/10.13039/501100011033 and "European Union NextGenerationEU/PRTR" under grant PDC2021-121368-C21; the MCIN/AEI/10.13039/501100011033 under grants PID2020-112628RA-I00 and PID2020-118480RB-C22.
RiuNet. Repositorio Institucional de la Universitat Politécnica de Valéncia
Publicación Artículo científico (JournalArticle)

Influence of material extrusion parameters on fracture mechanisms of polylactic acid under three-point bending

  • Álvarez-Blanco, Mario
  • Arias-Blanco, Adrián
  • Marco, Miguel
  • Miguélez, María Henar
  • Infante-García, Diego|||0000-0001-6010-2031
  • Giner Maravilla, Eugenio|||0000-0003-1903-6495
[EN] In this work, a thorough fracture assessment of additive manufactured specimens made by 3D printed polylactic acid (PLA) under three-point bending is presented. This polymer is widely used in additive manufacturing for numerous applications, gaining prominence in fields such as biomechanics. Prismatic fully dense specimens and lattice structure specimens with different raster orientations and densities were fabricated using the material extrusion-based additive manufacturing technique. The objective is to analyse the effect of relevant process parameters on the fracture mechanism of short beam specimens tested under three-point bending. Digital image correlation and computed tomography have been used to measure the full field displacement and internal defects, respectively. Furthermore, the theory of critical distances was applied to assess the mechanical strength of lattice structure specimens. The results have shown the strong influence of raster orientation on the mechanical strength and fracture patterns even for negative air gap values. The transition from brittle to ductile failure was observed when changing density and raster orientation. Lastly, neck-shaped defects were detected in knots of specimens manufactured with a grid pattern. Defects in grid pattern specimens appear due to the prescribed path followed by the extruder during the building process. They were the main source causing a decrease in the mechanical strength and fracture trajectories. The objective of this research is to enhance the knowledge on the mechanical response of 3D printed components and to give an in-depth failure assessment., The authors gratefully acknowledge the funding support received from the Spanish Ministerio de Ciencia e Innovacion for funding the projects PID2020-112628RA-I00 and PID2020-118480RB-C21, -C22, MCIN/AEI / 10.13039/501100011033 and by "ERDF A way of making Europe"; project PDC2021-121368-C21 and C22 funded by MCIN/AEI/ 10.13039/501100011033 and by the "European Union NextGenerationEU/PRTR". The authors also thank the funding received from Madrid Community (Spain) through the project IND2020/IND-17413. The financial support of Generalitat Valenciana and European Social Fund through Programme PROMETEO 2021/046 and CIAPOS/2021/271 is also acknowledged. Lastly, the Universitat Politecnica de Valencia is acknowledged for the financial support through PAID-PD-22.
RiuNet. Repositorio Institucional de la Universitat Politécnica de Valéncia
Publicación Artículo científico (JournalArticle)

Development of bone surrogates by material extrusion-based additive manufacturing to mimic flexural mechanical behaviour and fracture prediction via phase-field approach

  • Álvarez-Blanco, Mario
  • Marco, Miguel
  • Miguélez, M. Henar
  • Infante-García, Diego|||0000-0001-6010-2031
  • Giner Maravilla, Eugenio|||0000-0003-1903-6495
[EN] Background and objective: The limited availability of human bone samples for investigation leads to the demand for alternatives. Bone surrogates are crucial in promoting research on the intricate mechanics of osseous tissue. However, solutions are restricted to commercial brands, which frequently fail to faithfully replicate the mechanical response of bone, or oversimplified customised simulants designed for a specific application. The manufacturing and assessment of reliable bone surrogates made of polylactic acid via material extrusion-based additive manufacturing are presented in this work. Methods: An experimental and numerical study with 3D-printed dog -bone and prismatic specimens was carried out to characterise the polymeric feedstock and analyse the influence of process parameters under three-point bending and quasi-static conditions. Besides, three porcine rib samples were considered as a reference for the development of the artificial bones. Bone surrogates were manufactured from the 3D-scanned real bone geometries. In order to reproduce the trabecular and cortical bone, a lattice structure for the infill and a compact shell surrounding the core were employed. Infill density and shell thickness were evaluated through different printing configurations. Additionally, a computational analysis based on the phase-field approach was conducted to simulate the experimental tests and predict fracture. The modelling considered homogenisation of the infill material. Results: Outcomes demonstrated the potential of the presented methodology. Maximum force and flexural stiffness were compared to real bone properties to find the optimal printing configuration, replicating the flexural mechanical behaviour of bone tissue. Certain configurations accurately reproduce the studied properties. Regarding the numerical model, strength and stiffness prediction was validated with experimental results. Conclusions: The presented methodology enables the manufacturing of artificial bones with accurate geometries and tailored mechanical properties. Furthermore, the described modelling strategy offers a powerful tool for designing bone surrogates., The authors gratefully acknowledge the funding support received from the Spanish Ministerio de Ciencia e Innovacion for funding the projects PID2020-112628RA-I00, PID2020-118480RB-C21 and C22, funded by MCIN/AEI/10.13039/501100011033 and by "ERDF A way of making Europe", and the funding received from the Madrid Community (Spain) through the project IND2020/IND-17413. The authors are also grateful for the funding received from Generalitat Valenciana and European Social Fund programmes PROMETEO/2021/046 and CIAPOS/2021/271, and to Universitat Politecnica de Valencia for the grant PAID-PD-22.
RiuNet. Repositorio Institucional de la Universitat Politécnica de Valéncia
Publicación Artículo científico (JournalArticle)

Experimental and numerical analysis of the influence of intramedullary nail position on the cut-out phenomenon

  • Arias-Blanco, A.
  • Marco, M.
  • Larraínzar-Garijo, R.
  • Miguélez, M. H.
  • Giner Maravilla, Eugenio|||0000-0003-1903-6495
[EN] Background and objective: Proximal femur fractures, colloquially known as hip fractures, are a common pathology with increasing incidence in the last years due to the enhanced ageing population. Regarding the extracapsular fracture, the treatment for this pathology consists of a fixation of the fragments using an osteosynthesis device, mainly the intramedullary nail. This repairing method implies several complications, which may include the failure of the fixation device, frequently occurring due to the "cut-out" mechanism. The present work focuses on the study of how the position of the cephalic screw, which should be fixed during surgery, affects the cut-out risk. Through experimental tests and numerical models some variables that can be critical for the cut-out phenomenon are analysed. Methods: This study has been carried out through a numerical model based on the finite element method and experimental tests. The digital image correlation technique has been used in experimental tests to measure displacements on the femoral surface with the objective of numerical model validation. Some basic daily activities with different intramedullary nail positions have been analysed through the numerical model, considering variables that can induce the cut-out complication. Results: The results show how the intramedullary nail position clearly influences the cut-out risk, showing that displacements in the upper, anterior and posterior direction increase the cut-out risk, while displacement in the lower direction endangers the intramedullary nail itself. Thus, the centred position is the one which reduces the cut-out risk. Conclusions: This work supposes an improvement in the knowledge of the cut-out phenomenon thanks to the combination of experimental testing and validated numerical models. The effects of different intramedullary nail positions in the femoral head are studied, including a novelty variable as torque, which is critical for the structural integrity of the fixation. The main conclusion of the work is the determination of the central intramedullary nail position as the most favourable one for decreasing the cut-out risk., The authors gratefully acknowledge the funding support received from the Spanish Ministry of Science and Innovation for funding project PID2020-112628RA-I00/AEI/10.13039/501100011033, projects PID2020-118480RB-C21 and -C22 and from the Madrid Community (Spain) through the project IND2020/IND-17413. The financial support of the European Union NextGenerationEU/PRTR through grant number PDC2021-121368-C21 and -C22 and the Generalitat Valenciana through Programme PROMETEO 2021/046 is also acknowledged.& nbsp;
RiuNet. Repositorio Institucional de la Universitat Politécnica de Valéncia
Publicación Artículo científico (JournalArticle)

Exploring mechanistic anomalies in additively manufactured structures

  • Youssef, George
  • Alvarez-Blanco, Mario
  • Rufo-Martin, Celia
  • Marco, Miguel
  • Infante-García, Diego|||0000-0001-6010-2031
[EN] The increasing prevalence of additive manufacturing with material extrusion necessitates a rigorous understanding of the process-property-performance relationship in 3D-printed polymers, particularly the consistency of mechanical properties despite manufacturing anomalies. This study experimentally and analytically investigates the variability in stiffness and tensile strength of polylactic acid (PLA) samples fabricated as flat layers and isogrids. Experimental tensile testing revealed comparable stiffness and strength across most configurations, irrespective of manufacturing-induced anomalies. Analytical models that were statistically penalized to account for manufacturing variability, considering randomized cross-sectional areas, demonstrated excellent agreement with the experimentally determined stiffness variability. Furthermore, the tensile strength of the flat layer was accurately predicted using the Tresca criterion, while Cohesive Zone Modelling effectively captured the failure behavior of the isogrid. Despite its linear assumptions, this integrated experimental-statistical framework offers a viable approach for predicting the mechanical response and assessing the reliability of additively manufactured components., The authors acknowledge the support of the National Science Foundation under Grant No. 2035663. They are also grateful for internal funding from San Diego State University and Universidad Carlos III de Madrid. Funding from the Department of Defense (W911NF1410039, W911NF1810477, W911NF2310150, and N00174-23-1-0009) is also acknowledged. George Youssef also acknowledges funding from the US-Spain Fulbright program. The authors gratefully acknowledge the funding support received from the Spanish Ministerio de Ciencia e Innovacion for funding the project PID2020-112628RA-I00/AEI/10.13039/501100011033. The authors are grateful to Dr. Cristina Moral for her exceptional assistance with the scanning electron microscope.
RiuNet. Repositorio Institucional de la Universitat Politécnica de Valéncia
Publicación Artículo científico (JournalArticle)

Numerical analysis of the influence of triply periodic minimal surface structures morphometry on the mechanical response

  • Belda Ricardo|||0000-0003-3913-5773
  • Megías-Díaz, Raquel|||0000-0002-1698-7108
  • Vercher Martínez, Ana|||0000-0003-3695-6461
  • Giner Maravilla, Eugenio|||0000-0003-1903-6495
  • Marco, Miguel
[EN] Background and Objective: Design of bone scaffolds requires a combination of material and geometry to fulfil requirements of mechanical properties, porosity and pore size. Triply Periodic Minimal Surface (TPMS) structures have gained attention due to their similarities to cancellous bone. In this work, we aim at exploring relationships between morphometry and mechanical properties for TPMS configurations.Methods: Eight TPMS structures are defined considering six porosity levels and their morphometry is characterized. The stiffness matrix of each structure is assessed and related to morphometry through a statistical analysis.Results: An orthotropic mechanical behavior has been derived from the numerical homogenization. Prop-erties decay exponentially for decreasing volume fraction. Through volume fraction variation, TPMS me-chanical properties can be selected to match bone properties in a range of 0.2% to 70% of the bulk mate-rial properties.Conclusions: The comparison between cancellous bone and TPMS morphometry, considering a unit cell size of 1.5 mm, reveals that the configurations analyzed in this work match the requirements of volume fraction, mean thickness and pore size. However, the TPMS studied in this work differ from cancellous bone anisotropy. The results in this paper provide a framework to select the proper TPMS configuration and its geometry for patient-specific applications., This work was supported by the Spanish Ministerio de Ciencia e Innovacion MCIN/AEI/10.13039/501100011033 through grant numbers PID2020-118480RB-C21, PID2020-118920RB-I0 0 and PID2020-112628RA-I0 0, the European Union NextGenerationEU/PRTR through grant number PDC2021-121368-C22 and the Generalitat Valenciana (Programme PROMETEO 2021/046 and Plan FDGENT 2018 GVA).
RiuNet. Repositorio Institucional de la Universitat Politécnica de Valéncia
Publicación Artículo científico (JournalArticle)

Printable and Tunable Bioresin with Strategically Decorated Molecular Structures

  • Rufo-Martín, Celia
  • Díaz-Álvarez, José
  • Miguélez, Henar
  • Youssef, George
  • Infante-García, Diego|||0000-0001-6010-2031
[EN] As personalized medicine rapidly evolves, there is a critical demand for advanced biocompatible materials surpassing current additive manufacturing capabilities. This study presents a novel printable bioresin engineered with tunable mechanical, thermal, and biocompatibility properties through strategic molecular modifications. The study introduces a new bioresin comprising methyl methacrylate (MMA), ethylene glycol dimethacrylate (EGDMA), and a photoinitiator, which is further enhanced by incorporating high molecular weight polymethyl methacrylate (PMMA) to improve biostability and mechanical performance. The integration of printable PMMA presents several synthesis and processing challenges, necessitating substantial modifications to the 3D printing process. Additionally, the bioresin is functionalized with antibacterial silver oxide and bone-growth-promoting hydroxyapatite at various weight ratios to extend its application further. The results demonstrate the agile printability of the novel bioresin and its potential for transformative impact in biomedical applications, offering a versatile material platform for additive manufacturing-enabled personalized medicine. This work highlights the adaptability of the novel printable bioresin for real-life applications and its capacity for multiscale structural tailoring, potentially achieving properties comparable to native tissues and extending beyond conventional additive manufacturing techniques., The authors acknowledge the support of the National Science Foundation under Grant No. 2035663. The authors are also grateful for internal funding from San Diego State University. Funding from the United States Department of Defense (W911NF1410039, W911NF1810477, W911NF2310150, and N00174-23-1-0009) is also acknowledged. Additionally, this work was supported by the MCIN/AEI/10.13039/501100011033 and "European Union NextGenerationEU/PRTR" under grant PDC2021-121368-C21; the MCIN/AEI/10.13039/501100011033 under grants PID2020-112628RA-I00 and PID2020-118480RB-C22; and by the Generalitat Valenciana under grant CIAPOS/2021/271.
RiuNet. Repositorio Institucional de la Universitat Politécnica de Valéncia
Publicación Artículo científico (JournalArticle)

Development, 3D printing, and mechanics of novel auxetic unit cell monostructures

  • Rufo-Martín, Celia
  • Díaz-Álvarez, José
  • Miguélez, María Henar
  • Koohbor, Behrad
  • Youssef, George
  • Infante-García, Diego|||0000-0001-6010-2031
[EN] Complex structures with unique mechanics are pivotal to advancing additive manufacturing, enabling applications where traditional methods are impractical. This study presents a novel 3D auxetic S-shaped monostructure designed for scalability, tunability, and printability using vat photopolymerization. Unit cell geometries were fabricated and experimentally evaluated under quasi-static loading conditions, with full-field analyses providing insights into their structural performance. Benchmarking against common auxetic structures (re-entrant and star topologies) highlighted the superior capabilities of the proposed design. The S-shaped monostructures exhibited geometric insensitivity in their force-displacement responses, with a stiffness of similar to 180 N/m, withstanding large displacements of 11 mm without fracture or self-contact and supporting forces up to 1.8 N (i.e., 95 times their weight) before fully recovering upon unloading. Computational and experimental results demonstrated robust spatial auxeticity, persisting up to 85 % of axial global displacement due to geometry-driven rigid body motion, independent of base material properties. The S-shaped structures achieved superior auxetic performance (nu(maxti) approximate to -0.43) compared to re-entrant (nu(maxti) approximate to -0.30) and star (nu(maxti) approximate to - 0.05) counterparts, with a monotonic and reversible auxetic response throughout loading. Strain contour analyses from digital image correlation validated the reduced stress concentrations and rigid body-dominated mechanism. The exceptional auxeticity and mechanical resilience of the S-shaped monostructures suggest promising applications in advanced designs, including 3D stackable configurations for impact mitigation applications., The authors acknowledge the support of the National Science Foundation under Grant No. 2035663 (G.Y.) and Grant No. 2035660 (B. K.) . The authors are also grateful for internal funding from San Diego State University, Rowan University, and Universidad Carlos III de Madrid. In particular, this work was supported by the MCIN/AEI/10.13039/501100011033 and "European Union NextGenerationEU/PRTR" under grant PDC2021-121368-C21; the MCIN/AEI/10.13039/501100011033 under grants PID2020-112628RA-I00 and PID2020-118480RB-C22. Funding from the U.S. Department of Defense (W911NF1410039, W911NF1810477, W911NF2310150, and N00174-23-1-0009) is also acknowledged.