Pasar al contenido principal

DISEÑO DE ALGORITMO DE DECISION CLINICA EN EL PROCESO DE SELECCION DEL TIPO DE LIO A IMPLANTAR PARA CORREGIR LA PRESBICIA Y CATARATAS

PID2021-122486OA-I00

•
Nombre agencia financiadora Agencia Estatal de Investigación
Acrónimo agencia financiadora AEI
Programa Programa Estatal para Impulsar la Investigación Científico-Técnica y su Transferencia
Subprograma Subprograma Estatal de Generación de Conocimiento
Convocatoria Proyectos de I+D+i (Generación de Conocimiento y Retos Investigación)
Año convocatoria 2021
Plan Estatal 2021-2023 Plan Estatal de Investigación Científica y Técnica y de Innovación
Centro beneficiario UNIVERSIDAD COMPLUTENSE DE MADRID

Resultados relacionados

Resultados totales (Incluyendo duplicados): 8
Encontrada(s) 1 página(s)

Docta Complutense
Publicación Artículo científico (JournalArticle)

Optical power profiles and aberrations of a non-diffractive wavefront-shaping extended depth of focus intraocular lens

  • Garzón Jiménez, Nuria
  • Gómez Pedrero, José Antonio
  • Albarrán Diego, César
  • Fernández Núñez, Sara
  • Villanueva Gómez-Chacón, Sara
  • García Montero, María
Purpose: This study is to evaluate the optical characteristics of a non-diffractive wavefront-shaping intraocular lens which incorporates surface refractive modifications for shaping the wavefront in order to achieve extended depth of focus (EDoF) and to assess whether the nominal power of this IOL influences the attainable add power. Methods: A commercially available optical bench NIMO TR1504 device (LAMBDA-X, Nivelles, Belgium) was employed to obtain full optical characterization of three non-diffractive EDoF intraocular lenses with + 10 D, + 20 D, and + 30 D powers. After NIMO measurements, data were computed using a custom-made MATLAB program (Mathworks, Inc., Natick, MA, USA) to evaluate the optical quality functions, such as the point spread function (PSF), wavefront profiles, and modulation transfer function (MTF) for two pupil sizes: 3 mm and 4.0 mm. Results: The non-diffractive EDoF intraocular lens showed a central serrated power profile behavior with additions of + 2.00 to + 2.50 D over the nominal power. Higher order aberrations were found to be driven mainly by the spherical aberration, with almost null comatic influence. Optical quality metrics showed good values, better for a 3 mm pupil compared to a 4.5 mm one, as expected. The three IOL powers tested showed a very similar behavior in terms of power and aberrometric profiles, with minimal to null differences related to the nominal power. Conclusion: The non-diffractive wavefront-shaping EDoF intraocular lens achieves a near addition up to + 2.50 D aiming for an extended range of vision, almost independently of the base power.
Docta Complutense
Publicación Artículo científico (JournalArticle)

Optical quality in vitro and in vivo of an extended depth-of-focus intraocular lens with isofocal design

  • Fernández-Núñez, Sara
  • Pérez-Sanz, Lidia
  • Gómez Pedrero, José Antonio
  • García Montero, María
  • Albarrán-Diego, César
  • Garzón Jiménez, Nuria
Purpose: The aim of this study is to compare optical quality results obtained in laboratory analysis (in vitro) versus clinical data (in vivo). Methods: The optical quality of ISOPure intraocular lens was assessed both in vitro and in vivo using the modulation transfer function (MTF) for 3.0 and 4.5 mm pupil diameters. In vitro measurements were obtained using deflectometer NIMO TRF1504, while in vivo measurements were taken with OPD-Scan III in a set of patients implanted with this lens. Ray tracing techniques were used to determine the MTF and area under MTF curve (MTFa) from the measured wavefront for the isolated lens and for the whole eye. Results: The MTF of the isolated lens obtained under both in vitro and in vivo conditions showed comparable results for both pupil sizes. However, differences were found when comparing the MTF of the whole eye with the lens implanted versus the MTF measured in vitro for 4.5 mm pupil size. Also, the MTFa defocus curve was compared with the defocus curve measured in vivo. Conclusion: The defocus curve from the in vivo study aligns closely with the MTFa of the in vitro model, with a useful defocus range of 0.40D. Thus, it is possible to anticipate the visual results of the implanted isofocal lens by using measurements on an optical bench and conducting optical simulations.
Zaguán. Repositorio Digital de la Universidad de Zaragoza
Publicación Artículo científico (JournalArticle)

Fourier series diffractive lens with extended depth of focus

  • Soria-Garcia, Angela
  • Sanchez-Brea, Luis Miguel
  • del Hoyo, Jesus
  • Torcal-Milla, Francisco Jose
  • Gomez-Pedrero, Jose Antonio
Angular diffractive lenses have been proven to achieve a narrow beam waist with a long depth of focus. We generalize these type of lenses by defining the angular distribution of the focal length as a Fourier series. The Fourier coefficients of the lens are optimized, using Particle Swarm Optimization algorithm, to minimize the beam width and increase its uniformity for a given depth of focus. In order to obtain a fast simulation during the optimization process, we used Chirp Z-transform algorithm. Finally, we performed an experimental verification of the results using a Spatial Light Modulator. The Fourier series diffractive lens presents a more uniform and narrower beam than previous angular lenses, in both simulations and experiments. These results may find applications in the design of contact and intraocular lenses with extended depth of focus, laser focusing and imaging systems.
Zaguán. Repositorio Digital de la Universidad de Zaragoza
Publicación Artículo científico (JournalArticle)

Chessboard-based achromatic binary Zone Plate

  • Fernández-Nuñez, Sara
  • Gómez-Pedrero, José Antonio
  • Torcal-Milla, Francisco José
  • Sanchez-Brea, Luis Miguel
We numerically and experimentally demonstrate the performance of a new kind of diffractive binary zone plate for chromatic aberration compensation: the chessboard-based zone plate. The proposed achromatic zone plate consists of two spatially multiplexed zone plates following the geometry given by a chessboard and improved with morphological filters and combination under the Nyquist frequency, to mitigate aliasing effects. The obtained results are compared with those given by a random pixel-based multiplexed zone plate, reported in the literature, showing similar optical behaviour. However, the chessboard-based zone plate presents a smoother appearance without the high-frequency irregularities of the random-based designs that could be more resistant to manufacturing errors. The proposed achromatic zone plate could result of interest in fields such as solar concentration, lithography, imaging systems, visual optics, and so on.
Docta Complutense
Publicación Artículo científico (JournalArticle)

Optical quality in vitro and in vivo of an extended depth-of-focus intraocular lens with isofocal design

  • Fernández-Núñez, Sara
  • Pérez-Sanz. Lidia
  • Albarrán-Diego, César
  • Garzón Jiménez, Nuria
  • García Montero, María
  • Gómez Pedrero, José Antonio
Purpose The aim of this study is to compare optical quality results obtained in laboratory analysis (in vitro) versus clinical data (in vivo). Methods The optical quality of ISOPure intraocular lens was assessed both in vitro and in vivo using the modulation transfer function (MTF) for 3.0 and 4.5 mm pupil diameters. In vitro measurements were obtained using deflectometer NIMO TRF1504, while in vivo measurements were taken with OPD-Scan III in a set of patients implanted with this lens. Ray tracing techniques were used to determine the MTF and area under MTF curve (MTFa) from the measured wavefront for the isolated lens and for the whole eye. Results The MTF of the isolated lens obtained under both in vitro and in vivo conditions showed comparable results for both pupil sizes. However, differences were found when comparing the MTF of the whole eye with the lens implanted versus the MTF measured in vitro for 4.5 mm pupil size. Also, the MTFa defocus curve was compared with the defocus curve measured in vivo. Conclusion The defocus curve from the in vivo study aligns closely with the MTFa of the in vitro model, with a useful defocus range of 0.40D. Thus, it is possible to anticipate the visual results of the implanted isofocal lens by using measurements on an optical bench and conducting optical simulations.
Docta Complutense
Publicación Artículo científico (JournalArticle)

Advanced vs. Standard Monofocal IOLs: Optical Quality and Patient-Perceived Visual Outcomes

  • Charbel, Carla
  • Pérez Sanz, Lidia
  • Garzón Jiménez, Nuria
  • Poyales, Francisco
  • Carballo Álvarez, Jesús
Background/Objectives: The objective of this study is to compare the optical and visual quality provided by the advanced monofocal intraocular lens (IOL) ISOPure and the standard monofocal IOL MicroPure in cataract patients, using objective and subjective assessments. Methods: This prospective, single-blind clinical study includes 28 patients with cataracts, bilaterally implanted with either the ISOPure or MicroPure IOL. Eligible eyes had no ocular comorbidities and regular corneal astigmatism ≤ 1.00 D. Three months postoperatively, uncorrected distance and intermediate (UDVA, UIVA) and corrected distance and intermediate (CDVA, DCIVA) visual acuities were measured at 4 m, 80 cm, and 66 cm under photopic (85 cd/m2) and mesopic (3.5 cd/m2) conditions. Photic phenomena, including halo and glare, were evaluated. Objective optical quality was assessed using Objective Scattering Index (OSI), Modulation Transfer Function (MTF), Strehl Ratio (SR), and ocular aberrations. Subjective patient satisfaction was evaluated using Quality of Vision (QoV) and Catquest-9SF questionnaires. Results: Under photopic conditions, logMAR DCIVA at 80 cm, UIVA at 66 cm, and DCIVA at 66 cm were 0.18 ± 0.06, 0.25 ± 0.12, and 0.20 ± 0.13, respectively, for ISOPure, and 0.22 ± 0.06, 0.30 ± 0.09, and 0.25 ± 0.09 for MicroPure (p = 0.05, 0.02, and 0.05, respectively). No significant differences were observed in halo/glare size or intensity, OSI, MTF, or SR. However, statistically significant differences were found in higher-order total aberrations for pupil sizes of 3.0, 4.0 mm, and 5.0 mm. Questionnaires indicated greater satisfaction and functional intermediate vision with ISOPure. Conclusions: The ISOPure IOL offers superior intermediate vision without compromising distance vision, delivering a balanced combination of optical quality, functional performance, and patient satisfaction.
Docta Complutense
Publicación Artículo científico (JournalArticle)

Power profile and optical performance of two extended range of vision intraocular lens designs

  • Vega, Fidel
  • Garzón Jiménez, Nuria
  • García Montero, María
  • Millán, María Sagrario
Purpose: To assess the power profile and optical performance of 2 extended range-of-vision (ERV) intraocular lenses (IOLs), TECNIS Eyhance (ICB00) and LuxSmart, and compare them with their monofocal counterpart lenses with similar platforms and materials: TECNIS 1-piece (ZCB00) and LuxGood, respectively. Setting: Optics and Optometry Faculties of Complutense University (Madrid) and Universitat Politècnica de Catalunya BarcelonaTech (Terrassa) in Spain. Design: Laboratory investigation on optical bench. Methods: For each design, the power distribution and (fourth and sixth-order) spherical aberration (SA) across the lens aperture were measured as well as the optical performance using modulation transfer function–based metrics with through-focus evaluation. 3 nominal powers (+10.00 diopters [D], +20.00 D, and +30.00 D) and 3 pupil sizes (2.0 mm, 3.0 mm, and 4.5 mm) were considered to assess whether the base power of the lens and pupillary dynamics have an influence on the depth-of-focus extension. Results: TECNIS Eyhance and LuxSmart IOLs had different power and SA profiles, but both designs shared a positive add power in their central region in comparison with their monofocal counterparts. LuxSmart had a greater add power while TECNIS Eyhance showed higher peak optical quality but smaller depth of focus. Conclusions: Differences of focus extension between the 2 ERV IOL designs are related to differences of power and SA profile. The nominal base power of the IOLs has little effect on their optical quality. However, pupil dynamics plays a key role since it determines the effective add power and optical performance of the ERV IOLs.
Docta Complutense
Publicación Artículo científico (JournalArticle)

Adaptive-Optics-Based Simulation of Astigmatism Effects on Visual Acuity with Enhanced Monofocal Intraocular Lenses.

  • Albarrán Diego, César
  • García Montero, María
  • Baoud Ould Haddi, Inas
  • Garzón Jiménez, Nuria
PURPOSE: To investigate the effect of low-to-moderate astigmatism magnitude, axis orientation and pupil size on distance and intermediate visual acuity with two enhanced monofocal intraocular lenses (IOL) using adaptive optics simulation. METHODS: This prospective, observational, within-subject comparative study included 24 presbyopic participants aged 50-69 years. Two enhanced monofocal IOLs (RayOne EMV and Tecnis Eyhance) were simulated using the SimVis Gekko adaptive optics visual simulator over the manifest distance refraction. Corrected-distance visual acuity (CDVA, 4 m) and distance-corrected intermediate visual acuity (DCIVA, 60 cm) were measured at baseline and with induced simple hyperopic astigmatism (+0.50, +1.00 and +1.50 D) at against-the-rule (ATR) and with-the-rule (WTR). Simulated pupil diameter was 3.0 mm for distance and 3.0 and 4.0 mm for intermediate vision. Visual acuity degradation relative to baseline (ΔVA) was analysed separately for both distances using linear mixed-effects models including IOL, astigmatism magnitude, axis orientation and pupil diameter as fixed effects. Significant IOL effects were explored using Holm-adjusted pairwise comparisons. RESULTS: At a far distance, baseline CDVA was similar between IOLs (p = 0.79) and ΔVA increased significantly with astigmatic magnitude (p < 0.001), being greater for WTR than ATR astigmatism (p < 0.001), with no significant IOL effect. Baseline DCIVA differed between IOLs and pupil size (both p < 0.001), with Eyhance showing better VA with a 3.0 mm pupil (p < 0.001). ΔVA increased with astigmatism magnitude (p < 0.001), axis orientation (p < 0.001) and pupil diameter (p < 0.001), with no significant differences between IOLs (p = 0.50). CONCLUSION: With simulated enhanced monofocal IOLs, VA deteriorates progressively with increasing hyperopic astigmatism at both distance and intermediate vision, with cylinder magnitude as the main determinant. Axis orientation and pupil diameter further modulate intermediate visual performance, while astigmatic tolerance remains comparable between RayOne EMV and Tecnis Eyhance across all tested conditions.