Pasar al contenido principal

INSTRUMENTACION Y METODOS PARA LA ADQUISICION Y PROCESAMIENTO DE DATOS POLARIMETRICOS COMBINADOS CON INTELIGENCIA ARTIFICIAL PARA APLICACIONES BIOMEDICAS Y BOTANICAS

PID2024-156240OB-C22

•
Nombre agencia financiadora Agencia Estatal de Investigación
Acrónimo agencia financiadora AEI
Programa Programa Estatal para la Investigación y el Desarrollo Experimental
Subprograma Subprograma Estatal de Generación de Conocimiento Científico-Técnico y Desarrollo Experimental
Convocatoria Proyectos de I+D+i (Generación de Conocimiento y Retos Investigación)
Año convocatoria 2024
Plan Estatal 2024-2027 Plan Estatal de Investigación Científica y Técnica y de Innovación
Centro beneficiario UNIVERSIDAD AUTONOMA DE BARCELONA

Resultados relacionados

Resultados totales (Incluyendo duplicados): 4
Encontrada(s) 1 página(s)

Dipòsit Digital de Documents de la UAB
Publicación Artículo científico (JournalArticle)

Color Crosstalk Correction in Linear Stokes Imaging Using a Color Polarization Camera with Simultaneous Three Wavelengths Illumination

  • Altaweel, Manal
  • Bisbal Amat, Judit|||0009-0005-8715-5543
  • Campos Coloma, Juan|||0000-0002-2479-4373
  • Lizana, Angel|||0000-0002-4861-8657
  • Estévez, Irene|||0000-0003-3693-8335
Polarimetric color cameras are a forefront technology that simultaneously captures polarimetric and color information by analyzing polarization states across different color channels, commonly red, green, and blue. In general, each of these color channels can carry different polarization information. Therefore, measuring the polarization Stokes vector at several discrete wavelengths simultaneously and with the highest possible resolution is of interest in multiple research areas. However, when a commercial color polarization sensor is used under simultaneous narrowband RGB illumination mode, its channels cannot be assumed to represent independent wavelength channels. Spectral overlap of the color filters introduces color crosstalk between wavelength-dependent analyzer intensities, which may bias the reconstructed Stokes parameters if it is not corrected before polarimetric inversion. Several methods have been proposed in the literature to address the color crosstalk problem but they typically assume that the polarization state is identical for all wavelengths. This assumption does not generally hold for real samples, which exhibit wavelength-dependent depolarization, retardance, and dichroism. To the best of our knowledge, this is the first work presenting a method that addresses the color crosstalk problem without assuming that the polarization state is identical across all wavelengths. In addition, Fourier domain demosaicking techniques are applied to interpolate the data and reconstruct the images. The present study demonstrates how the proposed method leads to an accurate recovery of chromatic and polarimetric information on both synthetic and real-world datasets. To test our approach, narrowband light beams at three wavelengths (470, 554, 630 nm), with different spatial polarization and degree of linear polarization distributions, have been simulated and validated with simulated and experimental data. The results demonstrate the feasibility of the method for accurate three polarization channels measurements.
RUA. Repositorio Institucional de la Universidad de Alicante
Publicación Otros (Other)

Mueller matrix polarimetry in the near-field of micro and nanophotonic structures

  • Francés, Jorge
  • Lizana Tutusaus, Ángel
  • Márquez, Andrés
  • Sánchez-Montes, Adriana R.
  • Estévez, Irene
  • Campos, Juan
  • Beléndez, Augusto
  • Francés, Jorge|||/items/dc8252c4-30fe-4a2f-a433-f7971329fcb1
  • Márquez, Andrés|||/items/124ea25f-0096-4a92-b0d3-28227c2beec0
  • Sánchez-Montes, Adriana R.|||/items/03c3a515-cd80-4dd6-99f9-ada9511ec3e0
  • Beléndez, Augusto|||/items/1ea7a525-ee45-4792-bd9a-a54f76963120
This work investigates the polarimetric behavior, with a special focus on depolarization effects, of a Ronchi-type metallic grating using the split-field finite-difference time-domain (SF-FDTD) method. The study is based on pointwise computation of Mueller matrices in both near- and far-field regimes, for both subwavelength and for suprawavelength scales, and different fill factors. In the near field, we find that local Mueller matrices often lead to covariance matrices with negative eigenvalues. Even though this is typically considered a breakdown of physical realizability, we demonstrate that they accurately encode the polarimetric transfer function of the structures. The detailed physical study of the results using Mueller matrix derived polarimetric descriptors needs to be restricted to regions where all eigenvalues remain positive, with clear trends: strong depolarization for subwavelength periods and low fill factors, while higher degrees of purity and reduced anisotropy are observed for larger periods and higher fill factors. Far-field Mueller matrices, associated with the diffraction orders, are always physically realizable and exhibit high polarimetric purity. The contrast between near- and far-field responses emphasizes the need for careful interpretation of local polarimetric data in nanostructures. These results support the use of polarimetric descriptors as valuable tools in the characterization of nanoscale optical systems.
Zaguán. Repositorio Digital de la Universidad de Zaragoza
Publicación Artículo científico (JournalArticle)

Interpretation of measured 3×3 partial depolarizing Mueller matrices

  • Gil, José J.
  • San José, Ignacio
  • Canabal-Carbia, Mónica
  • Campos, Juan
  • Lizana, Angel
  • Estévez, Irene
Mueller polarimetry is a powerful technique with broad applications in astronomy, remote sensing, advanced material analysis, and biomedical imaging. However, instrumental constraints frequently restrict the measurement to an incomplete Mueller matrix limited to its upper-left 3×3 submatrix. Simply padding the missing entries with zeros to form a 4×4 matrix can produce physically inconsistent results, for both nondepolarizing and depolarizing systems. To address this issue, we present a systematic procedure to complete 3×3 measured Mueller matrices into physically consistent 4×4 matrices. The method relies on the covariance matrix formalism and selects, among the infinitely many admissible completions, the one with maximal polarimetric purity. This criterion ensures that the synthesized matrix corresponds to the least random (most deterministic) two-component model compatible with the measurement. The procedure is fully general and can be applied to any 3×3 partial Mueller polarimetric data, providing a reliable and physically grounded reconstruction tool for polarimetric imaging and materials characterization.
Zaguán. Repositorio Digital de la Universidad de Zaragoza
Publicación Contribución de congreso (ConferenceOutput)

Consistent reconstruction of partially measured Mueller matrices: enpolarizing, depolarizing, and retarding descriptors

  • Gil, José J.
  • San José, Ignacio
  • Canabal-Carbia, Monica
  • Campos, Juan
  • Lizana, Angel
  • Estévez, Irene
Many polarimetric imaging systems, such as division-of-focal-plane cameras or miniaturized endoscopic instruments, deliver incomplete Mueller matrices, typically restricted to the upper-left 3×3 block sensitive to linear polarization. Directly padding the missing entries with zeros often leads to unphysical 4×4 matrices and distorts depolarization metrics. Here we present a practical reconstruction strategy that, from any measured 3×3 block, synthesizes a physically admissible 4×4 Mueller matrix by selecting, among the infinitely many compatible completions, a statistical model whose associated covariance matrix H has rank at most two (no more than two spectral components) while exhibiting maximal polarimetric purity. We summarize the algorithm in a form directly translatable into numerical code, illustrate its behavior with synthetic examples, and discuss its use as a “polarimetric denoising” tool in imaging. This work focuses on the operational aspects and imaging-oriented implications of the method, while a companion journal article provides the full mathematical details.