Pasar al contenido principal

Resultados relacionados

Resultados totales (Incluyendo duplicados): 16
Encontrada(s) 1 página(s)

Dipòsit Digital de Documents de la UAB
Publicación Artículo científico (JournalArticle)

Revealing hidden bioimaging information by isotropic depolarization filtering

  • Canabal-Carbia, Mónica|||0000-0002-3735-1176
  • Estévez, Irene|||0000-0003-3693-8335
  • González-Arnay, Emilio
  • Montes-Gonzalez, Ivan
  • Gil, José J.
  • Barrera Roy, Arnau
  • Garcia-Caurel, Enrique
  • Ossikovski, Razvigor
  • Moreno, Ignacio|||0000-0002-1550-0601
  • Campos Coloma, Juan|||0000-0002-2479-4373
  • Lizana, Angel|||0000-0002-4861-8657
We propose an imaging method to enhance and reveal structures within samples by using a polarization-based filter. This filter removes the isotropic content while amplifying the anisotropic component of depolarization. Whereas isotropic depolarization leads to a complete loss of polarimetric information, the anisotropic one is connected with intrinsic characteristics of samples. The filter has the capability to diminish the isotropic depolarization of samples, revealing their inherent information. As representative cases, we analyze the effect of the filter in heart and brain sections of animal origin. Results highlight the outstanding performance of the filter. In heart, myocardial and subendocardial structures are better visualized, whereas in the brain, fiber tracts are identified. These proves the significance of this filter in the medical field, paving the way to the early detection of pathologies. The methodologies here presented could be applied in a wide range of applications, providing a significant advance in polarization imaging where high isotropic depolarization response is present, this being a common scenario in nature.
Dipòsit Digital de Documents de la UAB
Publicación Artículo de revisión (ReviewArticle)

IPP and PRT Depolarizing Spaces for the Study of Depolarizing Samples, A Review

  • Li, Dekui|||0000-0002-1704-7898
  • Montes-Gonzalez, Ivan
  • Estévez, Irene|||0000-0003-3693-8335
  • Canabal-Carbia, Mónica|||0000-0002-3735-1176
  • López Coronado, Octavi|||0000-0001-9525-6372
  • Mao, Yuxuan
  • Van Eeckhout, Albert|||0000-0003-2540-2746
  • Moreno, Ignacio|||0000-0002-1550-0601
  • Campos Coloma, Juan|||0000-0002-2479-4373
  • Guo, Zhongyi|||0000-0001-7282-2503
  • Tan, Yi
  • Lizana, Angel|||0000-0002-4861-8657
Depolarizing spaces can reveal and emphasize depolarization origins in samples, making them suitable tools for target detection and disease diagnosis. The Indices of Polarization Purity (IPP) space, considered a representative depolarizing space, highlights the depolarization characteristics of samples, and has demonstrated its superiority in analyzing and identifying depolarization samples, i.e., biological tissues and scattering environments. Recently, a new polarization representation, the so-called Polarizance-Reflection-Transformation (PRT) space has been proposed, which has been employed to distinguish between non-depolarization systems, as well as analyze anisotropic depolarizers. Importantly, the IPP and PRT spaces provide complementary information of samples, hence presenting more polarimetric characterizations of the samples of interest. In consideration of the high importance of the IPP and PRT spaces in this topic, in this paper, we review the methodology of these two spaces and their applications in depolarizer distinction.
IRTA Pubpro. Open Digital Archive
Publicación Artículo científico (JournalArticle)

Polarimetric Images of Biological Tissues Based on the Arrow Decomposition of Mueller Matrices

  • Gil, José J.
  • San José, Ignacio
  • Canabal-Carbia, Mónica
  • Estévez, Irene
  • González-Arnay, Emilio
  • Luque, Jordi
  • Garnatje, Teresa
  • Campos, Juan
  • Lizana, Angel
Polarimetric techniques are widely used in a vast number of applications such as remote sensing, material characterization, astronomy and biological tissue inspection. In this last scenario, different polarimetric observables have proved their potential for enhancing imaging visualization. In this work we use a set of polarimetric observables derived from the arrow decomposition of the Mueller matrix for the first time: enpolarizing, retarding and depolarizing descriptors. In particular, the mean intensity coefficient and the three indices of polarimetric purity, the absolute values and Poincaré orientations of diattenuation, polarizance, entrance retardance and exit retardance vectors are considered. Results show images with enhanced visualization or even revealing invisible structures when compared to standard intensity images. In particular, thanks to these metrics, we improve the visualization of the necrotic areas of a Vitis rupestris leaf. In the case of animal samples, boundaries between different fascicles inside a tendon of an ex vivo chicken sample are revealed, as is the directionality of fiber tracts of the subcortical white matter in an ex vivo cow brain. The experimental results show the potential for biophotonics imaging and how polarimetric techniques could be useful for biomedical and botanical applications., info:eu-repo/semantics/publishedVersion
RUA. Repositorio Institucional de la Universidad de Alicante
Publicación Otros (Other)

Connecting the microscopic depolarizing origin of samples with macroscopic measures of the Indices of Polarimetric Purity

  • Canabal-Carbia, Mónica
  • Estévez, Irene
  • Nabadda, Esther
  • Garcia-Caurel, Enrique
  • Gil, J.J.
  • Ossikovski, Razvigor
  • Márquez, Andrés
  • Moreno Soriano, Ignacio
  • Campos, Juan
  • Lizana Tutusaus, Ángel
  • Márquez, Andrés|||/items/124ea25f-0096-4a92-b0d3-28227c2beec0
In this work we show how a specific set of three depolarizing observables, the Indices of Polarimetric Purity (IPP), P1, P2 and P3, are ideal metrics to study the depolarization characteristic of media. We simulate different depolarizing scenarios, based on different depolarizing origins, and we study the corresponding IPP values. The simulations are based on the incoherent addition of multiple elemental polarizing elements, as ideal polarizers and/or retarders with different specific characteristics (orientation, retardance, transmittance, etc.). Further depolarizing scenarios are also studied by including the effect of ideal depolarizers. We show for the first time how by analyzing depolarizing systems through IPP we unravel two different depolarizing origins: isotropic and anisotropic depolarization, with meaningful physical interpretation. The former, isotropic depolarization is related to pure scattering processes, and mainly connected with P3 observable. The later, anisotropic depolarization is originated by microscopic constituent elements showing polarimetric anisotropy (dichroic and/or birefringent elements with different characteristics) and anisotropic scattering produced by these elements, and mainly described by P1 and P2 observables. Both effects can be simultaneously observed in real samples and give us information of the processes that give rise to depolarization in light-matter interactions. The simulated results are experimentally validated by analyzing the depolarizing behavior, in terms of IPP, of diverse real samples with easy physical interpretation, and direct connection with simulations. The present study could be of interest in multiple scenarios, to further understand the depolarizing response of samples, and it can be of special interest for the study of biological tissues and pathologies, as they present important depolarizing behavior.
RUA. Repositorio Institucional de la Universidad de Alicante
Publicación Otros (Other)

Biological tissue-enhanced visualization through polarimetric observables

  • Canabal-Carbia, Mónica
  • Estévez, Irene
  • Sánchez-Montes, Adriana R.
  • Marroco, Maria
  • Gil, Jose J.
  • San José, Ignacio
  • González-Arnay, Emilio
  • Campos, Juan
  • Lizana Tutusaus, Ángel
  • Sánchez-Montes, Adriana R.|||/items/03c3a515-cd80-4dd6-99f9-ada9511ec3e0
Polarimetry comprises a set of optical techniques of great interest in biophotonics due to its capability to obtain relevant information from biological samples by means of noninvasive and nondestructive methods. For instance, they are useful in pathology detection or different biological structures classification, among others. By studying the polarimetric response of biological samples we can obtain the information of how different structures produce different changes in the polarimetric characteristics of light. These changes depend on the polarimetric properties of the samples: depolarization, dichroism or retardance. From the experimental measurement of the Mueller matrix (M) of a sample, these polarimetric observables related to the mentioned tissue properties can be obtained. In this work, we propose the study of a particular set of observables derived from the Arrow decomposition of M. These parameters are used to inspect different biological tissues properties with the purpose of obtaining images with enhanced contrast of different biological structures in a tissue. In particular, we applied these observables to the study of a sample of animal origin: an ex-vivo cow brain; in order to differentiate between white and gray matter. Obtained results provide the interest of Arrow-derived polarimetric observables which may be of interest in multiple biomedical scenarios such as early pathology detection and diagnosis or enhanced visualization of different structures for clinical applications.
DIGITAL.CSIC. Repositorio Institucional del CSIC
Publicación Artículo científico (JournalArticle)

Polarimetric Images of Biological Tissues Based on the Arrow Decomposition of Mueller Matrices

  • Gil, José J.
  • San José, Ignacio
  • Canabal-Carbia, Mónica
  • Estévez, Irene
  • González-Arnay, Emilio
  • Luque, Jordi
  • Garnatje, Teresa
  • Campos, Juan
  • Lizana, Ángel
Polarimetric techniques are widely used in a vast number of applications such as remote sensing, material characterization, astronomy and biological tissue inspection. In this last scenario, different polarimetric observables have proved their potential for enhancing imaging visualization. In this work we use a set of polarimetric observables derived from the arrow decomposition of the Mueller matrix for the first time: enpolarizing, retarding and depolarizing descriptors. In particular, the mean intensity coefficient and the three indices of polarimetric purity, the absolute values and Poincaré orientations of diattenuation, polarizance, entrance retardance and exit retardance vectors are considered. Results show images with enhanced visualization or even revealing invisible structures when compared to standard intensity images. In particular, thanks to these metrics, we improve the visualization of the necrotic areas of a Vitis rupestris leaf. In the case of animal samples, boundaries between different fascicles inside a tendon of an ex vivo chicken sample are revealed, as is the directionality of fiber tracts of the subcortical white matter in an ex vivo cow brain. The experimental results show the potential for biophotonics imaging and how polarimetric techniques could be useful for biomedical and botanical applications., This research was funded by Ministerio de Ciencia e Innovación and Fondos FEDER (PID2021-126509OB-C21 and PDC2022-133332-C21), Generalitat de Catalunya (2021SGR00138) and Beatriu de Pinós Fellowship (2021-BP-00206)., Peer reviewed
DIGITAL.CSIC. Repositorio Institucional del CSIC
Publicación Artículo científico (JournalArticle)

Engineering Chiroptical Interactions through Integrating Plasmonic Arrays with Cholesteric Nanocellulose

  • Tao, Han
  • Jo, Sunghwan
  • Chu, Guang
  • Qi, Xiaoyu
  • Estévez, Irene
  • Lizana, Angel
  • Xu, Wenyang
  • Deng, Shengwei
  • Mihi, Agustín
  • Kontturi, Eero
Achieving scalable fabrication with precise control of chiroptical properties in chiral plasmonic materials remains challenging. We present a new family of engineered chiroptical composites comprising linearly assembled gold nanoparticle arrays integrated with cholesteric self-assembled cellulose nanocrystals (CNCs). Aqueous CNC suspensions are cast onto pre-assembled achiral plasmonic nanoparticle arrays via evaporation-induced transfer imprinting lithography, yielding centimeter-scale hybrid films with custom-tailored chiroptical responses. During drying, CNCs co-assemble with the gold nanoparticles at the interface, preserving the array's linear arrangement and keeping it isolated from the overlying cholesteric CNC layers. This configuration combines the linear dichroism of the plasmonic array with the linear birefringence of the CNC matrix, producing strong and tunable plasmonic circular dichroism at the surface lattice resonance, reaching 1217 ± 51 mdeg with a dissymmetry factor of -0.19 ± 0.02. Our approach provides a sustainable platform for engineering multifunctional chiral plasmonic materials with potential applications in optical sensing, photonic devices, and chiral biointerfaces., H.T. acknowledges financial support from Alfred Kordelin Foundation and Academy of Finland (No. 318890 and 318891, Competence Centre for Materials Bioeconomy, FinnCERES). H.T. acknowledges the provision of facilities and technical support by Aalto University at OtaNano-Nanomicroscopy Center (Aalto-NMC). G.C. acknowledges financial support from the National Natural Science Foundation of China (No. 22572028) and the Open Project of State Key Laboratory of Inorganic Synthesis and Preparative Chemistry (Grant number: 2025-2). This work has received funding from the Spanish Agencia Estatal de Investigación (MCIN/AEI/10.13039/501100011033) through grants, PID2022-141956NB-I00 (OUTLIGHT). ICMAB is supported by the Severo Ochoa program from the Spanish MINECO (CCEX2023-001263-S). This research was also kindly supported by the European Union through the EIC PATHFINDER OPEN project 101046489 (DYNAMO). X.Q. is grateful to the China Scholarship Council and the auspices of the Ph.D. program in Materials Science from Universitat Autònoma de Barcelona. I.E. and A.L. acknowledge financial support from Ministerio de Ciencia e Innovación and Fondos FEDER (PID2021-562-126509OB-C21 and PDC2022-133332-C21) and Generalitat de Catalunya (2021SGR00138). The authors acknowledge the assistance of the ICMAB-CSIC Electron Microscopy Services. The authors sincerely thank Prof. Nicholas A. Kotov and Dr. Luis Alberto Pérez for their valuable suggestions., With funding from the Spanish government through the ‘Severo Ochoa Centre of Excellence’ accreditation (CEX2023-001263-S)., Peer reviewed
Zaguán. Repositorio Digital de la Universidad de Zaragoza
Publicación Artículo científico (JournalArticle)

Polarimetric images of biological tissues based on the arrow decomposition of Mueller matrices

  • Gil, José J.
  • San José, Ignacio
  • Canabal-Carbia, Mónica
  • Estévez, Irene
  • González-Arnay, Emilio
  • Luque, Jordi
  • Garnatje, Teresa
  • Campos, Juan
  • Lizana, Angel
Polarimetric techniques are widely used in a vast number of applications such as remote sensing, material characterization, astronomy and biological tissue inspection. In this last scenario, different polarimetric observables have proved their potential for enhancing imaging visualization. In this work we use a set of polarimetric observables derived from the arrow decomposition of the Mueller matrix for the first time: enpolarizing, retarding and depolarizing descriptors. In particular, the mean intensity coefficient and the three indices of polarimetric purity, the absolute values and Poincaré orientations of diattenuation, polarizance, entrance retardance and exit retardance vectors are considered. Results show images with enhanced visualization or even revealing invisible structures when compared to standard intensity images. In particular, thanks to these metrics, we improve the visualization of the necrotic areas of a Vitis rupestris leaf. In the case of animal samples, boundaries between different fascicles inside a tendon of an ex vivo chicken sample are revealed, as is the directionality of fiber tracts of the subcortical white matter in an ex vivo cow brain. The experimental results show the potential for biophotonics imaging and how polarimetric techniques could be useful for biomedical and botanical applications.
Zaguán. Repositorio Digital de la Universidad de Zaragoza
Publicación Artículo científico (JournalArticle)

Connecting the microscopic depolarizing origin of samples with macroscopic measures of the Indices of Polarimetric Purity

  • Canabal-Carbia, Mónica
  • Estévez, Irene
  • Nabadda, Esther
  • Garcia-Caurel, Enrique
  • Gil, J.J.
  • Ossikovski, Razvigor
  • Márquez, Andrés
  • Moreno, Ignacio
  • Campos, Juan
  • Lizana, Angel
In this work we show how a specific set of three depolarizing observables, the Indices of Polarimetric Purity (IPP), P1, P2 and P3, are ideal metrics to study the depolarization characteristic of media. We simulate different depolarizing scenarios, based on different depolarizing origins, and we study the corresponding IPP values. The simulations are based on the incoherent addition of multiple elemental polarizing elements, as ideal polarizers and/or retarders with different specific characteristics (orientation, retardance, transmittance, etc.). Further depolarizing scenarios are also studied by including the effect of ideal depolarizers. We show for the first time how by analyzing depolarizing systems through IPP we unravel two different depolarizing origins: isotropic and anisotropic depolarization, with meaningful physical interpretation. The former, isotropic depolarization is related to pure scattering processes, and mainly connected with P3 observable. The later, anisotropic depolarization is originated by microscopic constituent elements showing polarimetric anisotropy (dichroic and/or birefringent elements with different characteristics) and anisotropic scattering produced by these elements, and mainly described by P1 and P2 observables. Both effects can be simultaneously observed in real samples and give us information of the processes that give rise to depolarization in light-matter interactions. The simulated results are experimentally validated by analyzing the depolarizing behavior, in terms of IPP, of diverse real samples with easy physical interpretation, and direct connection with simulations. The present study could be of interest in multiple scenarios, to further understand the depolarizing response of samples, and it can be of special interest for the study of biological tissues and pathologies, as they present important depolarizing behavior.
Zaguán. Repositorio Digital de la Universidad de Zaragoza
Publicación Artículo científico (JournalArticle)

Revealing hidden bioimaging information by isotropic depolarization filtering

  • Canabal-Carbia, Mónica
  • Estévez, Irene
  • González-Arnay, Emilio
  • Montes-Gonzalez, Ivan
  • Gil, Jose J.
  • Barrera, Anrau
  • García-Caurel, Enrique
  • Ossikovski, Razvigor
  • Moreno, Ignacio
  • Campos, Juan
  • Lizana, Angel
We propose an imaging method to enhance and reveal structures within samples by using a polarization-based filter. This filter removes the isotropic content while amplifying the anisotropic component of depolarization. Whereas isotropic depolarization leads to a complete loss of polarimetric information, the anisotropic one is connected with intrinsic characteristics of samples. The filter has the capability to diminish the isotropic depolarization of samples, revealing their inherent information. As representative cases, we analyze the effect of the filter in heart and brain sections of animal origin. Results highlight the outstanding performance of the filter. In heart, myocardial and subendocardial structures are better visualized, whereas in the brain, fiber tracts are identified. These proves the significance of this filter in the medical field, paving the way to the early detection of pathologies. The methodologies here presented could be applied in a wide range of applications, providing a significant advance in polarization imaging where high isotropic depolarization response is present, this being a common scenario in nature
Zaguán. Repositorio Digital de la Universidad de Zaragoza
Publicación Artículo científico (JournalArticle)

Interpretation of measured 3×3 partial depolarizing Mueller matrices

  • Gil, José J.
  • San José, Ignacio
  • Canabal-Carbia, Mónica
  • Campos, Juan
  • Lizana, Angel
  • Estévez, Irene
Mueller polarimetry is a powerful technique with broad applications in astronomy, remote sensing, advanced material analysis, and biomedical imaging. However, instrumental constraints frequently restrict the measurement to an incomplete Mueller matrix limited to its upper-left 3×3 submatrix. Simply padding the missing entries with zeros to form a 4×4 matrix can produce physically inconsistent results, for both nondepolarizing and depolarizing systems. To address this issue, we present a systematic procedure to complete 3×3 measured Mueller matrices into physically consistent 4×4 matrices. The method relies on the covariance matrix formalism and selects, among the infinitely many admissible completions, the one with maximal polarimetric purity. This criterion ensures that the synthesized matrix corresponds to the least random (most deterministic) two-component model compatible with the measurement. The procedure is fully general and can be applied to any 3×3 partial Mueller polarimetric data, providing a reliable and physically grounded reconstruction tool for polarimetric imaging and materials characterization.
Zaguán. Repositorio Digital de la Universidad de Zaragoza
Publicación Contribución de congreso (ConferenceOutput)

Consistent reconstruction of partially measured Mueller matrices: enpolarizing, depolarizing, and retarding descriptors

  • Gil, José J.
  • San José, Ignacio
  • Canabal-Carbia, Monica
  • Campos, Juan
  • Lizana, Angel
  • Estévez, Irene
Many polarimetric imaging systems, such as division-of-focal-plane cameras or miniaturized endoscopic instruments, deliver incomplete Mueller matrices, typically restricted to the upper-left 3×3 block sensitive to linear polarization. Directly padding the missing entries with zeros often leads to unphysical 4×4 matrices and distorts depolarization metrics. Here we present a practical reconstruction strategy that, from any measured 3×3 block, synthesizes a physically admissible 4×4 Mueller matrix by selecting, among the infinitely many compatible completions, a statistical model whose associated covariance matrix H has rank at most two (no more than two spectral components) while exhibiting maximal polarimetric purity. We summarize the algorithm in a form directly translatable into numerical code, illustrate its behavior with synthetic examples, and discuss its use as a “polarimetric denoising” tool in imaging. This work focuses on the operational aspects and imaging-oriented implications of the method, while a companion journal article provides the full mathematical details.
Recercat. Dipósit de la Recerca de Catalunya
Publicación Artículo científico (JournalArticle)

Polarimetric Images of Biological Tissues Based on the Arrow Decomposition of Mueller Matrices

  • Gil, José J.
  • San José, Ignacio
  • Canabal-Carbia, Mónica
  • Estévez, Irene
  • González-Arnay, Emilio
  • Luque, Jordi
  • Garnatje, Teresa
  • Campos, Juan
  • Lizana, Angel
Polarimetric techniques are widely used in a vast number of applications such as remote sensing, material characterization, astronomy and biological tissue inspection. In this last scenario, different polarimetric observables have proved their potential for enhancing imaging visualization. In this work we use a set of polarimetric observables derived from the arrow decomposition of the Mueller matrix for the first time: enpolarizing, retarding and depolarizing descriptors. In particular, the mean intensity coefficient and the three indices of polarimetric purity, the absolute values and Poincaré orientations of diattenuation, polarizance, entrance retardance and exit retardance vectors are considered. Results show images with enhanced visualization or even revealing invisible structures when compared to standard intensity images. In particular, thanks to these metrics, we improve the visualization of the necrotic areas of a Vitis rupestris leaf. In the case of animal samples, boundaries between different fascicles inside a tendon of an ex vivo chicken sample are revealed, as is the directionality of fiber tracts of the subcortical white matter in an ex vivo cow brain. The experimental results show the potential for biophotonics imaging and how polarimetric techniques could be useful for biomedical and botanical applications., info:eu-repo/semantics/publishedVersion
Dipòsit Digital de Documents de la UAB
Publicación Artículo científico (JournalArticle)

Polarimetric Images of Biological Tissues Based on the Arrow Decomposition of Mueller Matrices

  • Gil Pérez, José Jorge|||0000-0003-1740-2244
  • San José, Ignacio|||0000-0002-5370-7232
  • Canabal-Carbia, Mónica|||0000-0002-3735-1176
  • Estévez, Irene|||0000-0003-3693-8335
  • González-Arnay, Emilio
  • Luque, Jordi|||0000-0003-0751-9692
  • Garnatje, Teresa|||0000-0001-6295-6217
  • Campos Coloma, Juan|||0000-0002-2479-4373
  • Lizana, Angel|||0000-0002-4861-8657
Polarimetric techniques are widely used in a vast number of applications such as remote sensing, material characterization, astronomy and biological tissue inspection. In this last scenario, different polarimetric observables have proved their potential for enhancing imaging visualization. In this work we use a set of polarimetric observables derived from the arrow decomposition of the Mueller matrix for the first time: enpolarizing, retarding and depolarizing descriptors. In particular, the mean intensity coefficient and the three indices of polarimetric purity, the absolute values and Poincaré orientations of diattenuation, polarizance, entrance retardance and exit retardance vectors are considered. Results show images with enhanced visualization or even revealing invisible structures when compared to standard intensity images. In particular, thanks to these metrics, we improve the visualization of the necrotic areas of a Vitis rupestris leaf. In the case of animal samples, boundaries between different fascicles inside a tendon of an ex vivo chicken sample are revealed, as is the directionality of fiber tracts of the subcortical white matter in an ex vivo cow brain. The experimental results show the potential for biophotonics imaging and how polarimetric techniques could be useful for biomedical and botanical applications.
Dipòsit Digital de Documents de la UAB
Publicación Artículo científico (JournalArticle)

Connecting the microscopic depolarizing origin of samples with macroscopic measures of the Indices of Polarimetric Purity

  • Canabal-Carbia, Mónica|||0000-0002-3735-1176
  • Estévez, Irene|||0000-0003-3693-8335
  • Nabadda, Esther|||0000-0002-6739-4468
  • Garcia-Caurel, Enrique
  • Gil Pérez, José Jorge|||0000-0003-1740-2244
  • Ossikovski, Razvigor
  • Márquez Ruiz, Andrés|||0000-0003-4123-2011
  • Moreno, Ignacio|||0000-0002-1550-0601
  • Campos Coloma, Juan|||0000-0002-2479-4373
  • Lizana, Angel|||0000-0002-4861-8657
In this work we show how a specific set of three depolarizing observables, the Indices of Polarimetric Purity (IPP), P1, P2 and P3, are ideal metrics to study the depolarization characteristic of media. We simulate different depolarizing scenarios, based on different depolarizing origins, and we study the corresponding IPP values. The simulations are based on the incoherent addition of multiple elemental polarizing elements, as ideal polarizers and/or retarders with different specific characteristics (orientation, retardance, transmittance, etc.). Further depolarizing scenarios are also studied by including the effect of ideal depolarizers. We show for the first time how by analyzing depolarizing systems through IPP we unravel two different depolarizing origins: isotropic and anisotropic depolarization, with meaningful physical interpretation. The former, isotropic depolarization is related to pure scattering processes, and mainly connected with P3 observable. The later, anisotropic depolarization is originated by microscopic constituent elements showing polarimetric anisotropy (dichroic and/or birefringent elements with different characteristics) and anisotropic scattering produced by these elements, and mainly described by P1 and P2 observables. Both effects can be simultaneously observed in real samples and give us information of the processes that give rise to depolarization in light-matter interactions. The simulated results are experimentally validated by analyzing the depolarizing behavior, in terms of IPP, of diverse real samples with easy physical interpretation, and direct connection with simulations. The present study could be of interest in multiple scenarios, to further understand the depolarizing response of samples, and it can be of special interest for the study of biological tissues and pathologies, as they present important depolarizing behavior.
Dipòsit Digital de Documents de la UAB
Publicación Artículo científico (JournalArticle)

Analysis of the Image Magnification Produced by Inline Holographic Systems Based on the Double-Sideband Filter

  • Ramirez, Claudio
  • Estévez, Irene|||0000-0003-3693-8335
  • Lizana, Angel|||0000-0002-4861-8657
  • Campos Coloma, Juan|||0000-0002-2479-4373
  • García-Canseco, Luisa
In-line digital holography is a powerful tool widely used for microscopic object imaging. Usually, in-line and out-line configurations are used to implement holographic systems, but in-line-based set-ups are preferable as they are less sensitive to mechanical vibrations and refraction index variations. However, non-desired blurred conjugate images are superposed to the reconstructed object image by using in-line systems. One strategy to remove the conjugate image contribution is to include a double-sideband filter at the Fourier plane of the system. After using the filter, data obtained at the CCD are processed to retrieve the magnitude and phase (hologram) of the diffracted wavefront while removing the conjugated image. Afterwards, a diffraction integral equation is used to digitally propagate the hologram. Despite the above-mentioned factors, there is not a thorough analysis in the literature of magnification parameters associated with the final reconstructed image, this aspect being crucial for the experimental application of the above-stated approach. Under this scenario, a theoretical analysis of the longitudinal and transverse magnifications of the reconstructed images is provided in this work. The method is validated through the simulation and experimental results of different microscopic objects: glass microspheres, a micrometric reticle, and a resolution test chart USAF 1951. The obtained results provide that the combination of magnification relations with methods for hologram propagation and optimal focused image identification is effective for object position determination. This approach could be useful for 3D microparticle localization and monitoring with optimized magnification within real-time applications.