Pasar al contenido principal

DISPOSITIVOS MINIATURIZADOS Y FLUIDICOS AVANZADOS PARA ANALISIS DE EXPOSOMICA DE ALTO RENDIMIENTO ENFOCADA A CONTAMINANTES DE PREOCUPACION EMERGENTE

PID2024-156804OB-C33

•
Nombre agencia financiadora Agencia Estatal de Investigación
Acrónimo agencia financiadora AEI
Programa Programa Estatal para la Investigación y el Desarrollo Experimental
Subprograma Subprograma Estatal de Generación de Conocimiento Científico-Técnico y Desarrollo Experimental
Convocatoria Proyectos de I+D+i (Generación de Conocimiento y Retos Investigación)
Año convocatoria 2024
Plan Estatal 2024-2027 Plan Estatal de Investigación Científica y Técnica y de Innovación
Centro beneficiario UNIVERSIDAD DE LAS ISLAS BALEARES

Resultados relacionados

Resultados totales (Incluyendo duplicados): 5
Encontrada(s) 1 página(s)

Repositori Institucional UIB
Publicación Artículo científico (JournalArticle)

Automatic flow-through oral bioaccessibility method for real-time monitoring of zinc leachability from bio-based food packaging edible films

  • Montefusco, Antonica V.
  • Oliver, Miquel
  • Pons, Magdalena
  • Izzi, Margherita
  • Sportelli, Maria Chiara
  • Cioffi, Nicola
  • Picca, Rosaria Anna
  • Miró, Manuel
[eng] Recent trends in food packaging for reducing the use of petroleum-based plastics and waste focus on the development of sustainable protecting films based on metal nanostructure embedded biopolymers. However, the safety of such bionanocomposites if human ingested has been poorly explored so far. In this work, crosslinked alginate films embedding ZnO nanostructures (Alg/ZnO) were prepared and analyzed as a case study. A dynamic flow-through approach mimicking human digestion by simulated gastric fluid (SGF) extraction was assembled. It consisted of an automatic sequential injection analysis (SIA) setup that enabled evaluating the zinc oral bioaccessibility from the as-prepared composites. The temporal release of Zn<sup>2+</sup> from 50 mg of Alg/ZnO films was monitored on-line by pumping SGF across film fragments in a flow-through container. Under fluidized-bed conditions, a quantitative retrieval of overall bioaccessible Zn<sup>2+</sup> was achieved using only 12 mL of extractant (6 cycles of 2 mL SGF each), resulting in a cumulative extraction time of 30 min. For every extraction cycle, 50 μL aliquot of the gastric extract was automatically aspirated and mixed on-line with buffered Zincon colorimetric reagent for the on-line spectrophotometric detection of bioaccessible Zn<sup>2+</sup>. The gastric bioaccessible zinc fraction from Alg/ZnO films was about 70%. In the event of ingestion of 0.4 g of high-content Alg/ZnO films, a human daily intake of 0.52 mg Zn was estimated. This value is significantly lower than the maximum tolerable daily intake of 40 mg/day for adults. The proposed approach represents an interesting solution for the assessment of metal ion human bioaccessibility in antimicrobial-containing packaging without using cell tests.
Repositori Institucional UIB
Publicación Artículo científico (JournalArticle)

3D-printed pipette-tip device for the efficient extraction of opioids from oral fluids using particulate-coated adhesive tapes as sorptive phases

  • Millán-Santiago, Jaime
  • Calero-Cañuelo, Carlos
  • Carrasco-Correa, Enrique Javier
  • Casado-Carmona, Francisco Antonio
  • Lucena, Rafael
  • Miró, Manuel
  • Cárdenas, Soledad
[eng] Background: Integrating planar sorptive phases into pipette tips enables easier sample handling with disposable units, which is especially relevant in bioanalysis. However, the flat shape of these phases does not fit well with the tip’s geometry. Consequently, the majority of the sample does not come into contact with the sorbent, thus reducing the extraction efficiency. In such conditions, the samples need to be aspirated several times to accomplish an acceptable extraction efficiency of the target compounds. This shortcoming makes the extraction tedious and slow. Results: In this article, a new 3D-printed pipette tip was developed to enable full exposure of the planar sorptive phase to the sample. To prove the potential of this approach, the determination of opioids in oral fluids was selected as a case of study. With the new platform, the extraction of the analytes is enhanced by a factor ranging from 3.3 to 5.1 compared to using a commercial pipette tip. The analytical performance showed competitive sensitivity, permitting the determination of the drugs in saliva. The intra-day and inter-day precision at the limit of quantification, expressed as relative standard deviation, were always better than 10.8 % and 24.7 %, respectively. In addition, the trueness (relative recovery) ranged from 87 % to 115 % for all target compounds. Notably, the use of isotopically labeled surrogates as internal standards for each compound significantly improved the analytical results. Significance and novelty: This study deepens the potential of 3D printing for designing functional extraction devices. In this case, the extraction kinetics are positively affected by changing the geometry of the planar sorptive phase holder. The new design allows proper exposure of the sorptive material, a particle-coated adhesive tape, to the bulk sample.
Repositori Institucional UIB
Publicación Artículo científico (JournalArticle)

Can we determine superoxide ion reliably? - Automatic flow system for the measurement of the superoxide lifetime in varied aqueous media

  • Galián-Salas, Miquel
  • Garcia-Moll, Llucía
  • Oliver, Miquel
  • Carrasco-Correa, Enrique Javier
  • Casado-Carmona, Francisco Antonio
  • Miró, Manuel
[eng] There is a quest of advanced analytical methodologies for reliable determination of trace level concentrations of superoxide anion radical in biological and environmental matrices, yet the validity of the current calibration approaches is questionable on account of the extremely short lifetime of the radical in aqueous media. To address this limitation, an automatic flow system using potassium superoxide dissolved in dimethylsulfoxide (DMSO) is herein proposed as a reliable calibration source. In DMSO, the superoxide stability was significantly ameliorated as compared to that in aqueous matrices with a half-life (t1/2) of 29.6 ± 1.5 min following first-order decay kinetics. The flow setup capitalizes on a visible-light chemiluminescent 'Cypridina luciferin'  analog MCLA for highly sensitive detection of the target, obtaining a limit of detection (LOD) of 126 fmol·L-1 and a linearity up to 6.4 nmol·L-1 with cross-validated recoveries ranging from 88 to 108 %.Reliable kinetic measurements of the superoxide radical generated via the xanthine/xanthine oxidase system were performed in different aqueous matrices, including marine culture medium, groundwater, seawater and HEPES buffer. The aim behind is to calculate t1/2 in every matrix as a crucial parameter for the determination of superoxide in water media. The calculated t1/2 values ranged from 2.2 s in seawater to 8.3 s in the marine culture medium, with variations attributed to differences in ionic strength and trace metal content. This work provides invaluable data on superoxide decay kinetics in environmental and biological aqueous systems, serving as an unrivalled calibration benchmark for accurate quantification of superoxide in real-world scenarios.
Repositori Institucional UIB
Publicación Artículo científico (JournalArticle)

Can we determine superoxide ion reliably? - Automatic flow system for the measurement of the superoxide lifetime in varied aqueous media

  • Galián Salas, Miquel
  • García Moll, Llucia
  • Oliver, Miquel
  • Carrasco Correa, Enrique Javier
  • Casado Carmona, Francisco Antonio
  • Miró, Manuel
[eng] There is a quest of advanced analytical methodologies for reliable determination of trace level concentrations of superoxide anion radical in biological and environmental matrices, yet the validity of the current calibration approaches is questionable on account of the extremely short lifetime of the radical in aqueous media. To address this limitation, an automatic flow system using potassium superoxide dissolved in dimethylsulfoxide (DMSO) is herein proposed as a reliable calibration source. In DMSO, the superoxide stability was significantly ameliorated as compared to that in aqueous matrices with a half-life (t 1/2) of 29.6 ± 1.5 min following first-order decay kinetics. The flow setup capitalizes on a visible-light chemiluminescent 'Cypridina luciferin' analog MCLA for highly sensitive detection of the target, obtaining a limit of detection (LOD) of 126 fmol L−1 and a linearity up to 6.4 nmol L−1 with cross-validated recoveries ranging from 88 to 108%. Reliable kinetic measurements of the superoxide radical generated via the xanthine/xanthine oxidase system were performed in different aqueous matrices, including marine culture medium, groundwater, seawater and HEPES buffer. The aim behind this is to calculate t 1/2 in every matrix as a crucial parameter for the determination of superoxide in water media. The calculated t 1/2 values ranged from 2.2 s in seawater to 8.3 s in the marine culture medium, with variations attributed to differences in ionic strength and trace metal content. This work provides invaluable data on superoxide decay kinetics in environmental and biological aqueous systems, serving as an unrivalled calibration benchmark for accurate quantification of superoxide in real-world scenarios.
Helvia. Repositorio Institucional de la Universidad de Córdoba
Publicación Artículo científico (JournalArticle)

3D-printed pipette-tip device for the efficient extraction of opioids from oral fluids using particulate-coated adhesive tapes as sorptive phases

  • Millán-Santiago, Jaime
  • Calero-Cañuelo, Carlos
  • Carrasco-Correa, Enrique Javier
  • Casado-Carmona, Francisco Antonio
  • Lucena, Rafael
  • Miró, Manuel
  • Cárdenas, Soledad
Background Integrating planar sorptive phases into pipette tips enables easier sample handling with disposable units, which is especially relevant in bioanalysis. However, the flat shape of these phases does not fit well with the tip's geometry. Consequently, the majority of the sample does not come into contact with the sorbent, thus reducing the extraction efficiency. In such conditions, the samples need to be aspirated several times to accomplish an acceptable extraction efficiency of the target compounds. This shortcoming makes the extraction tedious and slow. Results In this article, a new 3D-printed pipette tip was developed to enable full exposure of the planar sorptive phase to the sample. To prove the potential of this approach, the determination of opioids in oral fluids was selected as a case of study. With the new platform, the extraction of the analytes is enhanced by a factor ranging from 3.3 to 5.1 compared to using a commercial pipette tip. The analytical performance showed competitive sensitivity, permitting the determination of the drugs in saliva. The intra-day and inter-day precision at the limit of quantification, expressed as relative standard deviation, were always better than 10.8 % and 24.7 %, respectively. In addition, the trueness (relative recovery) ranged from 87 % to 115 % for all target compounds. Notably, the use of isotopically labeled surrogates as internal standards for each compound significantly improved the analytical results. Significance and novelty This study deepens the potential of 3D printing for designing functional extraction devices. In this case, the extraction kinetics are positively affected by changing the geometry of the planar sorptive phase holder. The new design allows proper exposure of the sorptive material, a particle-coated adhesive tape, to the bulk sample.