PREPARACION ASEQUIBLE DE MUESTRA EN ANALISIS DE DROGAS: DISEÑANDO HERRAMIENTAS MAS SIMPLES PARA RESOLVER UN PROBLEMA GLOBAL

PID2023-146313OB-I00

•
Nombre agencia financiadora Agencia Estatal de Investigación
Acrónimo agencia financiadora AEI
Programa Programa Estatal para Impulsar la Investigación Científico-Técnica y su Transferencia
Subprograma Subprograma Estatal de Generación de Conocimiento
Convocatoria Proyectos de I+D+i (Generación de Conocimiento y Retos Investigación)
Año convocatoria 2023
Plan Estatal 2021-2023 Plan Estatal de Investigación Científica y Técnica y de Innovación
Centro beneficiario UNIVERSIDAD DE CORDOBA

Resultados relacionados

Resultados totales (Incluyendo duplicados): 11
Encontrada(s) 1 página(s)

Repositori Institucional UIB
Publicación Artículo científico (JournalArticle)

3D-printed pipette-tip device for the efficient extraction of opioids from oral fluids using particulate-coated adhesive tapes as sorptive phases

  • Millán-Santiago, Jaime
  • Calero-Cañuelo, Carlos
  • Carrasco-Correa, Enrique Javier
  • Casado-Carmona, Francisco Antonio
  • Lucena, Rafael
  • Miró, Manuel
  • Cárdenas, Soledad
[eng] Background: Integrating planar sorptive phases into pipette tips enables easier sample handling with disposable units, which is especially relevant in bioanalysis. However, the flat shape of these phases does not fit well with the tip’s geometry. Consequently, the majority of the sample does not come into contact with the sorbent, thus reducing the extraction efficiency. In such conditions, the samples need to be aspirated several times to accomplish an acceptable extraction efficiency of the target compounds. This shortcoming makes the extraction tedious and slow. Results: In this article, a new 3D-printed pipette tip was developed to enable full exposure of the planar sorptive phase to the sample. To prove the potential of this approach, the determination of opioids in oral fluids was selected as a case of study. With the new platform, the extraction of the analytes is enhanced by a factor ranging from 3.3 to 5.1 compared to using a commercial pipette tip. The analytical performance showed competitive sensitivity, permitting the determination of the drugs in saliva. The intra-day and inter-day precision at the limit of quantification, expressed as relative standard deviation, were always better than 10.8 % and 24.7 %, respectively. In addition, the trueness (relative recovery) ranged from 87 % to 115 % for all target compounds. Notably, the use of isotopically labeled surrogates as internal standards for each compound significantly improved the analytical results. Significance and novelty: This study deepens the potential of 3D printing for designing functional extraction devices. In this case, the extraction kinetics are positively affected by changing the geometry of the planar sorptive phase holder. The new design allows proper exposure of the sorptive material, a particle-coated adhesive tape, to the bulk sample.
Helvia. Repositorio Institucional de la Universidad de Córdoba
Publicación Artículo científico (JournalArticle)

Silica microparticles as guiding substrates for the fabrication of polyamide-coated stainless-steel sheets by dip-coating technique: Application to the determination of opioids in saliva samples by direct infusion mass spectrometry

  • Pedraza-Soto, Ana M.
  • Lucena, Rafael
  • Cárdenas, Soledad
Background Dip-coating is a simple and cost-effective technique for synthesizing thin film sorptive phases in microextraction. The success of the coating (amount and homogeneity) relies dramatically on the wettability of the substrate, thus making the covering of smooth-surface substrates challenging. In these cases, prior to the slurry (particles and binder) deposition, the smooth-surface substrate typically requires an aggressive etching step (e.g., treating the surface with strong acids or bases) to increase the roughness of the metallic substrate. This strategy has a clear environmental and operational safety impact and increases the associated costs. Results In this article, we explored the use of amorphous silica gel particles as a cost-effective guiding substrate to improve the wettability and increase the superficial area of the final coating. For this purpose, a double-sided adhesive tape is used to immobilize the silica particles over stainless-steel sheets, thus creating a porous substrate where a thin layer of polymer is finally deposited by dip-coating. The resulting nylon-silica gel sheets (NSG-sheet) have been evaluated for the extraction of some opioids (codeine, methadone, oxycodone, and tramadol) from saliva samples and their direct infusion mass spectrometry analysis. The developed method allows the determination of the analytes at the low μg L−1 range with levels with intra- and inter-day precision, expressed as relative standard deviation, better than 9.5 and 13.7 %, respectively. Significance and novelty This research deepens the potential of adhesive tapes for designing novel sorptive phases. It also provides a straightforward approach to synthesizing thin film microextraction devices using affordable and sustainable materials and procedures. The resulting analytical method has been thoroughly validated, and it has been demonstrated to be competitive with existing methods. Also, the potential of the devices in on-site extraction procedures has been preliminarily explored.
Helvia. Repositorio Institucional de la Universidad de Córdoba
Publicación Artículo científico (JournalArticle)

Quantitative determination of drug residues in surfaces, analyzing cotton-swabs by on/off thermal desorption-plasma based ionization-mass spectrometry

  • Cárdenas, Soledad
  • Calero-Cañuelo, Carlos
  • Lucena, Rafael
  • Cárdenas, Soledad
Background The determination of drug residues in surfaces is a relevant analytical problem in forensic sciences. Ambient ionization mass spectrometry (AIMS) has revolutionized this field, providing high sensitivity and selectivity levels at shorter analysis times, thus permitting quick decision-making. Those surfaces that cannot be directly measured require their previous sampling with an appropriate swab that can finally be analyzed by AIMS. In this field, dielectric barrier discharge ionization is a great alternative for analyzing swabs after surface sampling in a quick and easy way. Results In this work, we propose sampling the surface with a cotton swab wet with an internal standard (IS) for better precision and easier quantification. After sampling, the swab is placed in a dedicated interface where an on/off thermal desorption takes place in front of the low-temperature plasma ionization source. The method was applied to the determination of three drugs in different surfaces, providing limits of detections as low as 0.01 ng/cm2. The intra-day and inter-day precision at the limit of quantification, expressed as relative standard deviation, were better than 10.8 and 15.2 %, respectively. The accuracy, expressed as relative recovery, was in the range of 81.6–124.5 %. Finally, the effect of the swab type on the analytical performance was evaluated. The use of a commercial swab is highly recommended. Significance and novelty This research succeeded in developing a simple methodology for the analysis of drugs on surfaces using cotton swabs. For this purpose, a methanolic solution containing the ISs facilitated sample collection and allowed the quantitative analysis. Also, a rapid analysis of the samples was carried out in an interface built with simple elements, making the whole process affordable and simple. The approach can be considered almost solventless (20 μL per sample), thus reducing the environmental impact.
Helvia. Repositorio Institucional de la Universidad de Córdoba
Publicación Artículo científico (JournalArticle)

Microbeads from recycled polystyrene yogurt cups for the in-syringe micro solid-phase extraction of four opioids from environmental and biological sample

  • Antonelli, Lorenzo
  • López-Lorente, A.I.
  • Gentili, Alessandra
  • Lucena, Rafael
  • Cárdenas, Soledad
A novel procedure for the extraction and determination of four opioids from environmental and biological fluids is presented. The main goal of this study is to introduce an innovative method for recycling plastic waste (i.e., polystyrene), aiming to achieve a consistent and dependable microstructure. Polystyrene microbeads, deposited on a rounded piece of paper, have been used as a sorbent material in an in-syringe extraction device. For the preparation of the polymeric sorbent, an emulsion solidification technique was optimized, achieving a regular micro material, obtained from second-hand regenerated polystyrene polymer from yogurt cups. This work presents, for the first time, the use of recycled polystyrene as micro-sorbent integrated into a paper-based support, combining waste valorization with effective analyte extraction. Under the optimum conditions, methadone, tramadol, codeine, and morphine were determined by direct injection mass spectrometry in environmental water as well as biofluids as saliva and urine. Limits of detection lower than 8 μg L−1 and precision better than 14.9 % have been obtained for all the analytes in saliva and environmental water samples. The interference of the endogenous compounds of urine prevents the determination of morphine and codeine in this matrix. The trueness, expressed as relative recovery (RR), ranged from 85 % to 114 %. The extraction device has proved to be a valid and sustainable alternative to traditional sorbents, offering good analytical standards and being transversal for the application to different matrices. The simplicity and environmental friendliness of this approach make it highly adaptable across various research and industrial domains.
Helvia. Repositorio Institucional de la Universidad de Córdoba
Publicación Artículo científico (JournalArticle)

Polyester-coated stainless-steel sheets using silica gel microparticles as surface pre-modifiers: a novel approach to determine selective serotonin reuptake inhibitors in saliva samples by direct infusion tandem mass spectrometry

  • Pedraza-Soto, Ana M.
  • Lucena, Rafael
  • Cárdenas, Soledad
Stainless-steel substrates have grown in importance in the development of planar sorptive phases. However, the reduced wettability of polished sheets makes difficult their functionalization. This limitation can be solved by using amorphous silica gel microparticles as superficial guides. These particles increase both the wettability and the surface area of the final sorptive phases, which has a key influence on the extraction kinetics. In this article, double-sided thermal-resistant adhesive tape was used as the binder to pre-immobilize the silica particles over the stainless-steel surface, thus avoiding aggressive etching procedures. A linear polyester (synthesized by conventional free melt polycondensation from 1,4-butanediol and phenylsuccinic acid) was deposited onto the particulate area by the drop-casting technique. The resulting polyester-silica gel sheets (PSG-sheets) have been evaluated for the extraction of four selective serotonin reuptake inhibitors (SSRI) (fluoxetine, paroxetine, sertraline, and venlafaxine) in saliva samples, followed by direct infusion mass spectrometry analysis. The method allows the determination of the target compounds at the low µg·L−1 range, and it was successfully applied to analyze a saliva sample from a patient under paroxetine treatment. The method also fulfills the typical validation criteria in terms of precision (intrer-day precision better than 16.5% at the limit of quantification) and accuracy (relative recoveries in the interval 87–123% at the limit of quantification), both parameters having been evaluated at four concentration levels.
Helvia. Repositorio Institucional de la Universidad de Córdoba
Publicación Artículo científico (JournalArticle)

A flower-shaped recycled polymeric-coated cellulose paper for the isolation of organic contaminants from waters

  • Samkampang, Khwanchanok
  • Soriano, M. Laura
  • Lucena, Rafael
  • Thammakhet-Buranachai, Chongdee
  • Cárdenas, Soledad
Polymeric waste, often discarded from everyday activities, poses environmental risks. An eco-sustainable thin-film microextraction approach (TFME) utilizing flower-like filter paper coated with waste polymers as the sorptive phase is presented herein for isolating volatile organic compounds (VOCs) from water samples. This particular phase configuration allows an efficient stirring with minimal resource consumption. The sorptive phase is prepared by dip-coating, which offers simplicity and enables simple polymer reusability. Low-density polyethylene (LDPE) and expanded polystyrene (PS) residues were evaluated as polymeric coatings, the latter providing a more efficient isolation of the analytes in shorter times. The effect of the main variables involved in the synthesis (paper size, polymer selection, concentration of the polymeric precursor, and the number of dips) and extraction process (extraction and elution parameters) was thoroughly evaluated. Working under the optimum conditions and using gas chromatography-mass spectrometry (GC–MS) as the instrumental technique, quantification limits in the range of 9–10 µg L-1 were obtained for toluene, o- and p-xylene, ethylbenzene and styrene. Intra-day and inter-day precision (expressed as relative standard deviation) better than 7.6 %, and accuracy (expressed as relative recoveries) in the 92–110 % range were also obtained. The developed method was applied successfully to varied drinking water samples, revealing pollutants across diverse packaging materials. In tap waters, laboratory levels of styrene were noted (18 ± 3 µg L-1). Mineral water in biobased cartons exhibited styrene, toluene (15.2 ± 0.3 µg L-1), o-xylene (5.5 ± 0.2 µg L-1), along with detected styrene and toluene in polyethylene terephthalate (PET) bottles.
Helvia. Repositorio Institucional de la Universidad de Córdoba
Publicación Artículo científico (JournalArticle)

Adhesive tapes as sampling probes and thermal desorption substrates, in search of direct analysis of particulate solid samples using Soft Ionization by Chemical Reaction In Transfer mass spectrometry

  • Calero-Cañuelo, Carlos
  • Lucena, Rafael
  • Cárdenas, Soledad
Direct analysis by mass spectrometry (MS) has emerged as a promising strategy for analyzing a broad range of samples. Among the different ionization techniques, plasma-based sources are simple alternatives that can be used to ionize a wide range of analytes, thus providing high analytical versatility. This article describes the design of a simple and cost-effective interface that uses adhesive tapes as both sampling probes and thermal desorption substrates. The particulate solid sample is adhered to the tape in a single and quick step, avoiding particle losses and protecting the interface from clogging. The probe is thermally desorbed in a dedicated chamber, built using commercial elements, in front of the MS inlet. The desorbed analytes are driven by the vacuum system (any supplementary carrier gas is not required), passing through the plasma-based source (Soft Ionization by Chemical Reaction In Transfer, SICRIT®), where they are ionized before being introduced in the spectrometer. The determination of caffeine in coffee has been evaluated as a proof of concept since the complexity of the matrix and the semivolatile character of the analyte can challenge the performance, allowing to check the potential of the new approach. The type of adhesive tape, the parameters related to the desorption and sample dilution have been studied in depth. Working under optimum conditions, LOD was settled down at 0.18 mg g−1. The intra-day and inter-day precision, expressed as relative standard deviation and calculated at three different concentration levels, were better than 12.5 and 13.7 %, respectively. Finally, the accuracy of this method was calculated by analyzing five different coffee samples and comparing the results with those provided by a reference method. The accuracy was in the range of 82.3–105.5 %. This interface is presented as a promising, simple, solvent-free approach for the direct analysis of solid samples. The interface has been finally applied to the analysis of drug mixtures to demonstrate its versatility.
Helvia. Repositorio Institucional de la Universidad de Córdoba
Publicación Artículo científico (JournalArticle)

Strategies for the electrochemical determination of drugs in biofluids: The role of sample preparation in sensitivity and selectivity enhancement

  • Bascón-Humanes, Marina
  • Soriano, M. Laura
  • Lucena, Rafael
  • Cárdenas, Soledad
The presence of drugs in different matrices is a growing concern that must be addressed to ensure prompt and accurate responses. They constitute a heterogeneous group of compounds and their low concentrations, as well as the potential presence of metabolites, make analytical determination more complex. In this context, sample preparation is a valuable tool for achieving the sensitivity and selectivity required for drug determination. This review discusses the role of this analytical process in combination with electrochemical detection for determining drugs in biofluids, compiling the scarce early examples that emerged before 2020 and critically evaluating the advances reported until 2025. The modification of electrodes and the introduction of extraction techniques have been critically discussed. Integrating sample preparation with electrochemical detection is identified as one of the most powerful approaches.
Helvia. Repositorio Institucional de la Universidad de Córdoba
Publicación Artículo científico (JournalArticle)

Venlafaxine as a dummy template for the synthesis of molecularly imprinted polymers for tramadol determination

  • Mansilla-Cejas, Teresa
  • Fresco-Cala, B.
  • Cárdenas, Soledad
A dummy-template molecularly imprinted polymer (MIP) for tramadol selective extraction was synthesized for the first time. The MIP, consisting of methacrylic acid (MAA) and ethylene glycol dimethacrylate (EDMA), was prepared on a filter paper support by photopolymerization. Venlafaxine was used as a dummy template because of its structural and chemical similarity to tramadol. This innovative strategy not only avoids template leakage but also overcomes the significant regulatory and economic limitations associated with using tramadol —a controlled and potentially abused substance— as a template. Furthermore, the paper-based photopolymerization approach enables the rapid synthesis of a surface-imprinted MIP layer on the support, which enhances accessibility to binding sites, improves mass transfer kinetics, and facilitates faster analyte recognition compared to conventional bulk MIPs. To achieve this purpose, the paper was pre-activated with benzophenone (BP) and EDMA, and incubated with the venlafaxine before the polymerization step. Non-molecular imprinted polymers (NIPs) were prepared using the same procedure without the template incubation step. The optimization of the synthesis variables, including the EDMA/MAA ratio, polymerization time, type of porogen, and concentration of venlafaxine, was carried out to find the best imprinting conditions. The final MIPs and corresponding NIPs were characterized by SEM. Moreover, the variables affecting the extraction procedure were optimized in order to improve the polymer sorbent capacity. HPLC-UV was employed for venlafaxine and tramadol identification and quantification. After optimization, MIPs presented an imprinting factor (IF) of 4.80 for venlafaxine (dummy template) and 4.70 for tramadol (target analyte), and a limit of detection (LOD) and a limit of quantification (LOQ) of 0.006 and 0.018 mg/L, respectively. The MIPs did not show a specific interaction with other drugs. The precision of the method, expressed as RSD (%), varied from 9.0 to 10.8 % (intra- and inter-day). MIPs were applied for tramadol extraction from human urine samples, obtaining recovery values of 95.0–95.7 %.
Helvia. Repositorio Institucional de la Universidad de Córdoba
Publicación Artículo científico (JournalArticle)

Microextraction of selective serotonin reuptake inhibitors from urine using poly(ethylene-co-vinyl acetate) coated paper-based sorptive phase: giving a new use to conventional materials

  • Hammadi, Saloua
  • Millán-Santiago, Jaime
  • Latrous, Latifa
  • Lucena, Rafael
  • Cárdenas, Soledad
Reusing polymer residues for synthesizing new sorptive phases is a relevant research topic in sample preparation that is in line with sustainability and affordability concepts. It allows giving an alternative use to chemical residues and permits the preparation of cost-effective sorbents. In this article, poly(ethylene-co-vinyl acetate) residues are employed for preparing a paper-based sorptive phase by the dip coating technique. The PSP is used to extract selective serotonin reuptake inhibitors (namely, sertraline, paroxetine, and fluoxetine) from urine samples using liquid chromatography coupled with mass spectrometry for the final determination. The different variables affecting the synthesis (polymer concentration and number of dips) and the extraction (pH, ionic strength, sample volume, and extraction time) have been evaluated using blank urine samples spiked with the analytes. The proposed method has been validated, obtaining limits of detection lower than 0.3 μg L−1, linear range from 1 to 600 μg L−1 (R2 > 0.999), intra-day and inter-day precision better than 8.4 and 19.0 %, respectively, and intra-day and inter-day accuracy values ranging from 88.8 to101.1 and from 96.3 to 108.1 %. Three different urine samples from patients under paroxetine and fluoxetine treatment were analyzed, obtaining concentrations within the linear range in all cases.
Helvia. Repositorio Institucional de la Universidad de Córdoba
Publicación Artículo científico (JournalArticle)

3D-printed pipette-tip device for the efficient extraction of opioids from oral fluids using particulate-coated adhesive tapes as sorptive phases

  • Millán-Santiago, Jaime
  • Calero-Cañuelo, Carlos
  • Carrasco-Correa, Enrique Javier
  • Casado-Carmona, Francisco Antonio
  • Lucena, Rafael
  • Miró, Manuel
  • Cárdenas, Soledad
Background Integrating planar sorptive phases into pipette tips enables easier sample handling with disposable units, which is especially relevant in bioanalysis. However, the flat shape of these phases does not fit well with the tip's geometry. Consequently, the majority of the sample does not come into contact with the sorbent, thus reducing the extraction efficiency. In such conditions, the samples need to be aspirated several times to accomplish an acceptable extraction efficiency of the target compounds. This shortcoming makes the extraction tedious and slow. Results In this article, a new 3D-printed pipette tip was developed to enable full exposure of the planar sorptive phase to the sample. To prove the potential of this approach, the determination of opioids in oral fluids was selected as a case of study. With the new platform, the extraction of the analytes is enhanced by a factor ranging from 3.3 to 5.1 compared to using a commercial pipette tip. The analytical performance showed competitive sensitivity, permitting the determination of the drugs in saliva. The intra-day and inter-day precision at the limit of quantification, expressed as relative standard deviation, were always better than 10.8 % and 24.7 %, respectively. In addition, the trueness (relative recovery) ranged from 87 % to 115 % for all target compounds. Notably, the use of isotopically labeled surrogates as internal standards for each compound significantly improved the analytical results. Significance and novelty This study deepens the potential of 3D printing for designing functional extraction devices. In this case, the extraction kinetics are positively affected by changing the geometry of the planar sorptive phase holder. The new design allows proper exposure of the sorptive material, a particle-coated adhesive tape, to the bulk sample.