Pasar al contenido principal

Resultados relacionados

Resultados totales (Incluyendo duplicados): 4
Encontrada(s) 1 página(s)

RiuNet. Repositorio Institucional de la Universitat Politécnica de Valéncia
Publicación Artículo científico (JournalArticle)

A survey on communication with in-body medical devices

  • Ambroziak, Slawomir J.
  • Korostynska, Olga
  • Bagheri, Nila
  • Skoric, Tamara
  • Sergiou, Charalampos
  • Katzis, Konstantinos
  • Kulakowski, Pawel
  • Garcia-Pardo, Concepcion|||0000-0002-2774-980X
  • Castelló-Palacios, Sergio|||0000-0003-4689-652X
[EN] Advancements in biotechnology, biomedical engineering, and microelectronics have paved the way for the era of the Internet of Medical Things, where in-body medical devices, such as implants, pacemakers, and biosensors, play a pivotal role in health monitoring and functional support for specific organs or tissues. This survey explores the feasibility of communication with in-body medical devices, addressing critical aspects including device architecture, communication capabilities, operational challenges within the human body, and the safety and security considerations of such systems. Initially, we present the implantable and ingestible medical devices, focusing on their capabilities for health monitoring as it pertains to personalized medicine. Then, we present a complete architecture of the personalized healthcare system, along with possible scenarios of communication between the system components. The next sections deal with frequency bands, wireless links, and antennas suitable for these types of communication. Then, signal processing techniques for in-body communication are described, focusing on power consumption and data rates, followed by a discussion of security issues for in-body networks. In the next section, we address the influence of the electromagnetic field on human tissues, together with the safety guidelines that in-body devices must exhibit. Finally, current standardization efforts related to in-body communications are reviewed. The paper concludes by highlighting the lessons learned and perspectives in the discussed areas., This work was supported in part by the COST Action INTERACT under Grant CA20120. It was also partially supported by the Provincial Secretariat for Science and Technological Development of the Autonomous Province of Vojvodina through the project 003076930 2024 09418 003 000 000 001 04 003 and the Ministry of Science, Technological Development and Innovations of the Republic of Serbia. Also, it was co-financed by a Fundacao para a Ciencia e a Tecnologia, I.P. (Portuguese Foundation for Science and Technology) through the Carnegie Mellon Portugal Program under the fellowship PRT/BD/154686/2023, FCT/MECI through national funds and, when applicable, co-funded by EU funds under UID/50008: Instituto de Telecomunicacoes and BID UBI-Santander Totta fellowship 2022/2023. Nila Bagheri would also like to thank Professor Fernando Jose Velez for his constructive comments.
RiuNet. Repositorio Institucional de la Universitat Politécnica de Valéncia
Publicación Artículo científico (JournalArticle)

CHEMONO: A Cherenkov-Only Monolithic Detector for PGI in Proton Range Verification

  • Rebolo, Leonor
  • Heller, Ryan
  • Correia, Pedro
  • Silva, Ana Luisa
  • James, Sara St.
  • Cates, Joshua W.
  • Arino-Estrada, Gerard
  • Freire-López-Fando, Marta
  • González Martínez, Antonio Javier
[EN] Proton range verification (PRV) in proton therapy is an unmet clinical need. Prompt-gamma imaging (PGI) using thick collimators is a PRV modality that has obtained the most success to-date. The gamma detectors in such approach consist of scintillation crystals coupled to photodetectors. In this work, we report the development and use of detectors made of monolithic pure Cherenkov emitter crystals for the same purpose. We demonstrate for the first time the ability of such detector configuration to provide spatial resolution information in one direction using measurements from a collimated slit. The detector consisted of a PbF2 crystal with dimensions 25 x 25 x 10 mm(3) coupled to a S13361-3050AE-08 array of 8 x 8 SiPMs from Hamamatsu. The SiPM array was connected to a row-column readout, with 8+8 channels, and triggered on the sum of the columns. Three different event reconstruction algorithms were tested: center of gravity (CoG), rise to the power (RTP), and neural network (NN). The NN yielded the best spatial resolution, with 3.7 +/- 0.9 mm full width half maximum (FWHM) in average for all positions. CoG and RTP also showed a consistent shift with the change of position of the slit, although with more modest results, between 4 and 7 mm in average for all positions. This is the first characterization of monolithic pure Cherenkov emitters for Multi-MeV gamma imaging. Results are promising for this detector concept, showing that it can offer an alternative for collimated PGI in PRV with potential of sustaining high count rates, with effective background rejection, and low production costs based on the cost of primary components of the crystals., This work was supported in part by the National Institutes of Health under Grant R01 EB029533 (PI Arino-Estrada), and in part by the i3N Portuguese National Funds through the FCT/MEC under Grant UIDB/50025/2020, Grant UIDP/50025/2020, and Grant LA/P/0037/2020. The work of Leonor Rebolo was supported by the Prototera financed by National Funds through the FCT/MEC under Grant PRT/BD/154945/2023.
DIGITAL.CSIC. Repositorio Institucional del CSIC
Publicación Artículo científico (JournalArticle)

Recent land use and land cover pressures on Iberian peatlands

  • Fernandes, Raquel
  • Geraldes, Miguel
  • Marchante, Elizabete
  • Durán, Jorge
  • Capinha, César
10 páginas, 6 figuras, 3 tablas, Iberian peatlands have been severely affected by land use and land cover (LULC) changes. Despite these pressures, some peatlands persist in the region, although their susceptibility to LULC change remains poorly understood. This study presents the most detailed and extensive distribution data for Iberian peatlands to date and analyzes the dynamics and drivers of LULC in Iberian peatlands and their surrounding areas. We compiled peatland records from various sources and used Corine Land Cover Change layers to determine LULC shifts in their surrounding areas for 1990, 2000, 2006, 2012, and 2018. Environmental and socioeconomic variables were used to create Boosted Regression Tree models explaining spatial variations in the mean percentage of changed area. Analysis of 270 peatland locations in the Iberian Peninsula revealed that forests and seminatural areas constituted over 80% of the peatland's surroundings. Agricultural areas expanded the most, except between 2006 and 2012 when the artificial areas showed more gains. While most surrounding areas experienced an average change of 0%-9.51% of the total area, between 1990 and 2018, lowland peatlands (littoral and sublittoral) suffered more intense changes (9.51% to 38.43%). Our models showed that only elevation and agricultural area density were relevant predictors of the spatial distribution of changes. Upland Iberian peatlands showed lower susceptibility to LULC change, while lowland peatlands underwent remarkable transformations. This study substantially expands previous knowledge about the distribution and conservation needs of these ecosystems in the Iberian Peninsula, especially those in littoral and sublittoral lowlands., Raquel Fernandes was supported by a grant (PRT/BD/153505/2021) financed by the Portuguese Foundation for Science and Technology (FCT) under MIT Portugal Program, Portugal. César Capinha, Miguel Geraldes, and Raquel Fernandes were also supported by FCT through Portuguese national funds to the CEG/IGOT Research Unit (UIDB/00295/2020 and UIDP/00295/2020). Elizabete Marchante was supported by grants LA/P/0092/2020 and UIDB/04004/2020. The field surveys were partially funded by the FCT project PTDC/AAC-AMB/111349/2009., Peer reviewed
Docta Complutense
Publicación Artículo científico (JournalArticle)

Development and characterisation of a radiobiology proton beamline using radiochromic film dosimetry

  • Marques Coelho, Carina
  • de la Fuente Fernández, Pablo
  • Bononad, Paula
  • Viñals, Sílvia
  • Tavares de Sousa, Célia
  • Galaviz, Daniel
  • Herrera, Federico
  • del Monte-García, Inés
  • Sánchez Parcerisa, Daniel
  • Cortés-Llanos, Belén
Objective. To develop and optimise a dedicated low-energy proton beamline at the Centre for Micro-Analysis of Materials (CMAM, Madrid, Spain) for radiobiological applications. Approach. An automated irradiation system was implemented, integrating Gafchromic EBT3 radiochromic film dosimetry corrected for linear energy transfer dependent quenching and post-irradiation darkening. Dosimetric calibration was performed using multichannel analysis, and beam performance was systematically evaluated as a function of distance, raster scanning area, beam intensity and reproducibility. Main results. Optimal operating conditions were identified at moderate beam currents (⩽1nA) and scanning areas of 40 × 40 to 50 × 50mm2, yielding homogeneous dose distributions with reproducibility better than 8%. The dosimetric protocol demonstrated linearity across clinically relevant dose ranges and allowed a reliable correlation between irradiation parameters and absorbed dose. Proof-of-concept experiments on U-87 MG glioblastoma cells confirmed the system’s ability to deliver controlled and biologically effective proton exposures, as demonstrated by clonogenic survival assays. Significance. These results establish the CMAM implantation beamline as a robust and versatile platform for preclinical proton radiobiology, providing accurate dosimetric control and supporting investigations of relative biological efficacy. The system facilitates translational advances in proton radiobiology, bridging physical and biological studies in low-energy proton irradiation.