Pasar al contenido principal

Resultados relacionados

Resultados totales (Incluyendo duplicados): 5
Encontrada(s) 1 página(s)

e-Archivo. Repositorio Institucional de la Universidad Carlos III de Madrid
Publicación Contribución de congreso (ConferenceOutput)

Automatic Cardiac Gating of Small-animal PET from List-mode Data

  • Herraiz, J. L.
  • Udías, José Manuel
  • Vaquero López, Juan José
  • Cusso Mula, Lorena
  • Desco Menéndez, Manuel
Proceedings of: 11th International Meeting on Fully Three-Dimensional Image Reconstruction in Radiology and Nuclear Medicine (Fully 3D 2011). 11-15 July, 2011, Potsdam, Germany., This work presents a method to obtain automatically the cardiac gating signal in a PET study of rats, by employing the variation with time of the counts in the cardiac region, that can be extracted from list-mode data. In an initial step, the cardiac region is identified in the image space by backward-projecting a small fraction of the acquired data and studying the variation with time of the counts in each voxel inside said region, with frequencies within 2 and 8 Hz. The region obtained corresponds accurately to the left-ventricle of the heart of the rat. In a second step, the lines-of-response (LORs) connected with this region are found by forward-projecting this region. The time variation of the number of counts in these LORs contains the cardiac motion information that we want to extract. This variation of counts with time is band-pass filtered to reduce noise, and the time signal so obtained is used to create the gating signal. The result was compared with a cardiac gating signal obtained from an ECG acquired simultaneously to the PET study. Reconstructed gated images obtained from both gating information are similar. The method proposed demonstrates that valid cardiac gating signals can be obtained for rats from PET list-mode data., This work was supported in part by AMIT Project funded by CDTI (CENIT Programme), UCM (Grupos UCM, 910059), CPAN (Consolider-Ingenio 2010, CSPD-2007-00042), RECAVA-RETIC network, Comunidad de Madrid (ARTEMIS S2009/DPI-1802), Ministerio de Ciencia e Innovación, Spanish Government (ENTEPRASE grant, PSE-300000-2009-5 and TEC2007-64731/TCM) and European Regional funds, Publicado
e-Archivo. Repositorio Institucional de la Universidad Carlos III de Madrid
Publicación Artículo científico (JournalArticle)

GPU-based fast iterative reconstruction of fully 3-D PET sinograms

  • Herraiz, J. L.
  • España, Samuel
  • Cabido, R.
  • Montemayor, A. S.
  • Desco Menéndez, Manuel
  • Vaquero López, Juan José
  • Udías, José Manuel
This work presents a graphics processing unit (GPU)-based implementation of a fully 3-D PET iterative reconstruction code, FIRST (Fast Iterative Reconstruction Software for [PET] Tomography), which was developed by our group. We describe the main steps followed to convert the FIRST code (which can run on several CPUs using the message passing interface [MPI] protocol) into a code where the main time-consuming parts of the reconstruction process (forward and backward projection) are massively parallelized on a GPU. Our objective was to obtain significant acceleration of the reconstruction without compromising the image quality or the flexibility of the CPU implementation. Therefore, we implemented a GPU version using an abstraction layer for the GPU, namely, CUDA C. The code reconstructs images from sinogram data, and with the same System Response Matrix obtained from Monte Carlo simulations than the CPU version. The use of memory was optimized to ensure good performance in the GPU. The code was adapted for the VrPET small-animal PET scanner. The CUDA version is more than 70 times faster than the original code running in a single core of a high-end CPU, with no loss of accuracy., This work was supported in part by AMIT Project funded by CDTI (CENIT Programme), UCM (Grupos UCM, 910059), CPAN (Consolider-Ingenio 2010, CSPD-2007-00042), RECAVA- RETIC network, Comunidad de Madrid (ARTEMIS S2009/DPI-1802), Ministerio de Ciencia e Innovación, Spanish Government (ENTEPRASE grant, PSE-300000-2009-5 and TEC2007-64731/TCM), and European Regional funds., Publicado
e-Archivo. Repositorio Institucional de la Universidad Carlos III de Madrid
Publicación Contribución de congreso (ConferenceOutput)

Validation of peneloPET simulations of the Biograph PET/CT scanner with TOF capabilities

  • Abushab, K. M.
  • Herraiz, J. L.
  • España, Samuel
  • Udías, José Manuel
  • Vaquero López, Juan José
  • Vicente, Esther
Actas de: XXVIII Congreso Anual de la Sociedad Española de Ingeniería Biomédica (CASEIB 2010). Madrid, 24-26 de noviembre de 2010., Monte Carlo simulations are currently widely used in positron emission tomography (PET) imaging for optimizing detector design and acquisition protocols, and for developing and assessing corrections and reconstruction methods. PeneloPET is a Monte Carlo code for PET simulations with basic components of detector geometry, acquisition electronics and material and source definitions. The purpose of the present study was to validate the simulations of the Siemens Biograph PET/CT scanner with TOF capabilities performed with peneloPET. The scanner components incorporate four rings of 48 detector blocks. Each block comprises 13 × 13 matrix of 4 × 4 × 20 mm3. Results were compared with experimental data obtained in accordance with the NEMA-2007 performance measurement protocol done by Jakoby, et al., This work has been supported by MEC (FPA2007-62216), UCM (Grupos UCM, 910059), CPAN (Consolider-Ingenio 2010) CSPD-2007-00042, the RECAVA-RETIC network, ARTEMIS S2009/DPI-1802, European Regional Development, ENTEPRASE grant, PSE-300000-2009-5 and TEC2008-0675-C02-01, Ministerio de Ciencia e Innovación. Spanish Government., Publicado
e-Archivo. Repositorio Institucional de la Universidad Carlos III de Madrid
Publicación Contribución de congreso (ConferenceOutput)

Corrección de atenuación de imágenes PET usando datos de TAC en el escáner para animales pequeños Argus PET/CT

  • Vicente, Esther
  • Udías, Ángel
  • López Herraiz, Joaquín
  • Udías, José Manuel
  • Desco Menéndez, Manuel
  • Vaquero López, Juan José
Actas de: XXVIII Congreso Anual de la Sociedad Española de Ingeniería Biomédica (CASEIB 2010). Madrid, 24-26 de noviembre de 2010., Existen diversos efectos físicos que degradan la calidad de la imagen PET, como por ejemplo la atenuación que sufren los fotones al atravesar el cuerpo en estudio. Este efecto reduce el número de fotones detectados, pero puede corregirse si se dispone de información anatómica del objeto. En este trabajo se describe la corrección de atenuación basada en una imagen TAC para el escáner de animales pequeños Argus PET/CT con imágenes PET reconstruidas con el algoritmo iterativo 3DOSEM., Este trabajo ha sido financiado en parte por el MEC (FPA2007-62216), la UCM (Grupos UCM, 910059), el CPAN (Consolider-Ingenio 2010, CSPD-2007-00042), la red RECAVA-RETIC el proyecto ARTEMIS (S2009/DPI-1802, Fondo Europeo de Desarrollo Regional), el proyecto ENTEPRASE (PSE-300000-2009-5, MICINN. España), por los proyectos del Ministerio de Ciencia e Innovación, TEC2007-64731, TEC 2008-06715-C02-1, la RETIC-RECAVA del Ministerio de Sanidad y Consumo, y el proyecto EU FP7 FMT-XCT-201792., Publicado
e-Archivo. Repositorio Institucional de la Universidad Carlos III de Madrid
Publicación Artículo científico (JournalArticle)

Automatic Cardiac Self-Gating of Small-Animal PET Data

  • Herraiz, J. L.
  • Herranz, Elena
  • Cal González, Jacobo
  • Vaquero López, Juan José
  • Desco Menéndez, Manuel
  • Cusso Mula, Lorena
  • Udías, José Manuel
Purpose: The cardiac gating signal (CGS) in positron emission tomography (PET) studies is usually obtained from an electrocardiography (ECG) monitor. In this work, we propose a method to obtain the CGS in small-animal PET using the acquired list-mode data without using any hardware or end-user input. Procedures: The CGS was obtained from the number of coincidences over time acquired in the lines-of-response connected with the cardiac region. This region is identified in the image as its value changes with frequencies in the range of 3 to 12 Hz. The procedure was tested in a study with 29 Wistar rats and 6 mice injected with 2-deoxy-2-[18F]fluoro-D-glucose, which underwent a 45-min single-bed list-mode PET scan of the heart syncronized with an ECG. The estimated signals and the reconstructed images using eight-gated frames were compared with the ones obtained using the ECG signal from the monitor. Results: The differences of the PET-based CGS with respect to the ECG relative to the duration of the heartbeats were 5.6 % in rats and 11.0 % in mice. The reconstructed gated images obtained from the proposed method do not differ qualitatively with respect to the ones obtained with the ECG. The quantitative analysis of both set of images were performed measuring the volume of the left ventricle (LV) of the rats in the end-of-systole and end-of-diastole phase. The differences found in these parameters between both methods were below 12.1 % in the ESV and 9.3 % in the EDV with a 95 % confidence interval, which are comparable to the accuracy (7 %) of the method used for segmenting the LV. Conclusion: The proposed method is able to provide a valid and accurate CGS in small-animal PET list-mode data. the ones obtained using the ECG signal from the monitor., This work was supported in part by Consejería de Educación, Juventud y Deporte de la Comunidad de Madrid (Spain) through the Madrid-MIT M+Visión Consortium, Comunidad de Madrid (S2013/MIT-3024 TOPUS-CM), UCM (Grupos UCM, 910059), CPAN (Consolider-Ingenio 2010, CSPD-2007-00042), RIC-RETIC network, Spanish MINECO (RD12/0042/0057),Ministerio de Ciencia e Innovación, Spanish Government (ENTEPRASE grant, PSE-300000-2009-5 and TEC2007-64731/TCM), and European Regional funds.