DIGITAL.CSIC. Repositorio Institucional del CSIC
Publicación Artículo científico (JournalArticle)

Comparative evaluation of the performance of electrochemical immunosensors using magnetic microparticles and nanoparticles. Application to the determination of tyrosine kinase receptor AXL

  • Serafín, Verónica
  • Batlle, M.
  • García de Frutos, Pablo
  • Campuzano, Susana
  • Yáñez-Sedeño, Pilar
Electrochemical sandwich immunoassay strategies involving the use of carboxyl-functionalized magnetic microbeads (cMBs) and magnetic nanoparticles (cMNPs) have been evaluated and compared. The proteolytically cleaved soluble tyrosine kinase receptor sAXL was used as the target analyte. Antibodies against AXL were covalently immobilized on cMBs or cMNPs. Immunobinding of AXL was detected by means of a secondary biotinylated antibody and a streptavidin-horseradish peroxidase conjugate. The electrochemical transduction was accomplished by capturing the cMBs or cMNPs bearing the immunoconjugates onto screen-printed carbon electrodes (SPCEs) by using a small magnet. The amperometric response was measured at −0.20 V (vs the silver pseudo-reference electrode of the SPCE) upon the addition of H2O2 in the presence of hydroquinone as the redox mediator. The calibration plots for AXL extended up to 7.5 ng mL−1 when cMBs were used for the preparation of the immunosensor and up to 40 ng mL−1 in the case of using cMNPs. The respective slope values were 158 (cMBs) and 43 nA mL ng−1 (cMNPs), while the achieved LODs were 74 (cMBs) and 75 pg mL−1 (cMNPs). Although the immunosensors prepared with cMBs provided a shorter range of linearity, they exhibited a 3.7-times larger sensitivity than those constructed with cMNPs. The successful application of the new strategies was demonstrated for the determination of the endogenous content of sAXL in real human serum samples (a cut-off value of 71 ng mL−1 have been established for patients with risk of heart failure). The immunosensors constructed using cMBs or cMNPs can be advanta geously compared, in terms of sensitivity and fabrication time, with the only immunosensor for AXL previously reported. In addition, these new immunosensors took approximately half time than ELISA to perform the assay., The financial support of projects: Retos Colaboración RTC-2015-4184-1 (cofinanced by the Ministry of Economy and Competitivity and FEDER Buna manera de hacer Europa^), CTQ2015-70023-R and CTQ2015-64402-C2-1-R (Spanish Ministry of Economy and Competitivity Research Projects) and S2013/ MT-3029 (NANOAVANSENS Program from the Comunidad de Madrid) are gratefully acknowledged. R.M. Torrente-Rodríguez acknowledges a predoctoral contract from the Spanish Ministry of Economy and Competitivity, Peer reviewed
DIGITAL.CSIC. Repositorio Institucional del CSIC
Publicación Artículo científico (JournalArticle)

Electrochemical immunosensor for receptor tyrosine kinase AXL using poly(pyrrolepropionic acid)-modified disposable electrodes

  • Serafín, Verónica
  • Torrente-Rodríguez, Rebeca M.
  • Batlle, Montserrat
  • García de Frutos, Pablo
  • Campuzano, Susana
  • Yáñez-Sedeño, Pilar
  • Pingarrón, José Manuel
A sensitive and rapid method for the determination of the clinically relevant biomarker receptor tyrosine kinase AXL in serum involving amperometric disposable immunosensors is reported. The target protein was sandwiched between a specific capture antibody covalently immobilized on screen-printed carbon electrodes modified with electropolymerized poly(pyrrolepropionic acid) and a biotinylated detector antibody labeled with a streptavidin-horseradish peroxidase conjugate. The amperometric responses were measured at −0.20 V vs the Ag pseudo-reference electrode of the SPCE upon the addition of H2O2 in the presence of hydroquinone (HQ) as mediator. This integrated immunosensing platform showed a low limit of detection (337 pg mL−1), a good selectivity against other non-target serum proteins, and provided results statistically in agreement with those obtained by using a commercial ELISA kit. These attractive features together with the simplicity and easy automation and miniaturization of the required instrumentation make the developed methodology a promising alternative in the development of devices for on-site clinical analysis., The financial support of projects: Retos Colaboración RTC2015-4184-1 (cofinanced by the Ministry of Economy and Competitivity and FEDER), CTQ2015-70023-R and CTQ2015- 64402-C2-1-R (Spanish Ministry of Economy and Competitivity Research Projects) and S2013/MT-3029 (NANOAVANSENS Program from the Comunidad de Madrid) are gratefully acknowledged. R.M. Torrente-Rodríguez acknowledges a predoctoral contract from the Spanish Ministerio de Economía y Competitividad., Peer reviewed
DIGITAL.CSIC. Repositorio Institucional del CSIC
Publicación Artículo científico (JournalArticle)

An electrochemical immunosensor for brain natriuretic peptide prepared with screen-printed carbon electrodes nanostructured with gold nanoparticles grafted through aryl diazonium salt chemistry

  • Serafín, Verónica
  • Torrente-Rodríguez, Rebeca M.
  • González-Cortés, Araceli
  • García de Frutos, Pablo
  • Sabaté, Manel
  • Campuzano, Susana
  • Yáñez-Sedeño, Pilar
  • Pingarrón, José Manuel
A sensitive amperometric immunosensor has been prepared by immobilization of capture antibodies onto gold nanoparticles (AuNPs) grafted on a screen-printed carbon electrode (SPCE) through aryl diazonium salt chemistry using 4-aminothiophenol (AuNPs-S-Phe-SPCE). The immunosensor was designed for the accurate determination of clinically relevant levels of B-type natriuretic peptide (BNP) in human serum samples. The nanostructured electrochemical platform resulted in an ordered layer of AuNPs onto SPCEs which combined the advantages of high conductivity and improved stability of immobilized biomolecules. The resulting disposable immunosensor used a sandwich type immunoassay involving a peroxidase-labeled detector antibody. The amperometric transduction was carried out at −0.20 V (vs the Ag pseudo-reference electrode) upon the addition of hydroquinone (HQ) as electron transfer mediator and H2O2 as the enzyme substrate. The nanostructured immunosensors show a storage stability of at least 25 days, a linear range between 0.014 and 15 ng mL−1, and a LOD of 4 pg mL−1, which is 100 times lower than the established cut-off value for heart failure (HF) diagnosis. The performance of the immunosensor is advantageously compared with that provided with immunosensors prepared by grafting SPCE with p-phenylendiamine (H2N-Phe-SPCE) and attaching AuNPs by immersion into an AuNPs suspension or by electrochemical deposition, as well as with immunosensors constructed using commercial AuNPs-modified SPCEs. The developed immunosensor was applied to the successful analysis of human serum from heart failure (HF) patients upon just a 10-times dilution as sample treatment., The financial support of projects: RetosColaboración RTC-2015- 4184-1 (cofinanced by the Ministry of Economy and Competitivity and FEDER “una manera de hacer Europa”), CTQ2015-70023-R and CTQ2015-64402-C2-1-R (Spanish Ministry of Economy and Competitivity Research Projects) and S2013/MT-3029 (NANOAVANSENS Program from the Comunidad de Madrid) are gratefully acknowledged. R.M. Torrente-Rodríguez acknowledges a predoctoral contract from the Spanish Ministerio de Economía y Competitividad., Peer reviewed
DIGITAL.CSIC. Repositorio Institucional del CSIC
Publicación Contribución de congreso (ConferenceOutput)

Detection of B-type natriuretic peptide (BNP) at screen printed carbon electrodes modified with gold nanoparticles grafted through aryl diazonium salt chemistry

  • Serafín, Verónica
  • Torrente-Rodríguez, Rebeca M.
  • Batlle, Montserrat
  • García de Frutos, Pablo
  • Campuzano, Susana
  • Yáñez-Sedeño, Pilar
  • Pingarrón, José Manuel
Trabajo presentado en la XXI Reunión de la Sociedad Española de Química Analítica, celebrada en Valencia, del 5 al 7 de septiembre de 2017, A key step in the proper functioning of an electrochemical biosensor is the surface architecture connecting the biological sample to the transducer. The type of materials involved, its geometry and size strongly affect the response of the biosensor. Furthermore, gold nanoparticles (AuNPs) have a strong capacity for biomolecules adsorption without losing of biological activity and facilitate the electron transfer between redox biomaterial and the electrode surface. Thus, immobilization of AuNPs on bulk electrodes using covalently attached organic layers containing thiol groups and amino groups on their distal end offers a simple, fast, and versatile approach for preparing nanoparticle electrode arrays with low background capacitance. On the order hand, since the signs and symptoms of heart failure (HF) are not very specific and the availability of echocardiography is limited, a very interesting alternative approach to diagnosis HF is to determine accurately the blood concentration of natriuretic peptides (NPs). Between them, the B-type natriuretic peptide (BNP) is a 32-amino acid polypeptide secreted by the ventricles of the heart in response to excessive stretching of heart muscle cells. Interestingly, it has been found that BNP concentration in serum is elevated in HF patients compared to controls, establishing a cut-off value of 400 pg mL-1 . With the purpose to develop a competitive electrochemical strategy for the accurate determination of clinically relevant levels of BNP in serum samples, in this work, we have prepared a sensitive electrochemical immunosensor for this polypeptide determination based on the immobilization of capture antibodies onto gold nanoparticles grafted through aryl diazonium salt chemistry onto screen-printed carbon electrodes (SPCEs) by means of a sandwich type immunoassay involving a peroxidase-labeled detector antibody. This novel nanostructured platform resulted in an ordered layer of gold nanoparticles adsorbed onto 4-aminothiophenol which combines the advantages of the high conductivity and the stability of immobilized biomolecules. To monitor the extension of the affinity reactions the amperometric transduction at disposable screen-printed carbon electrodes was performed at -200 mV (vs the Ag pseudo-reference electrode) upon addition of hydroquinone (HQ) as electron transfer mediator and H2O2 as the enzyme substrate. After optimizing all the experimental variables affecting the operation and response of this immunosensing approach its analytical performance was characterized and their practical applicability successfully demonstrated by analysis of real human serum samples. The promising analytical performance exhibited by this new amperometric immunosensor of simple operation, disposable SPCE format and possibility to use pocket-size electrochemical transducers makes it very attractive alternative to commonly used ELISAs for the development of automated POC systems for on-site determination of this powerful biomarker associated with HF., The financial support of projects: Retos Colaboración RTC-2015-4184-1 (cofinanced by the Ministry of Economy and Competitivity and FEDER “una manera de hacer Europa”), CTQ2015-70023-R and CTQ2015-64402-C2-1-R (MINECO Research Projects) and S2013/MT-3029 (NANOAVANSENS Program from the Comunidad de Madrid) are gratefully acknowledged., Peer reviewed
DIGITAL.CSIC. Repositorio Institucional del CSIC
Publicación Artículo científico (JournalArticle)

Easily Multiplexable Immunoplatform to Assist Heart Failure Diagnosis through Amperometric Determination of Galectin‐3

  • Piguillem, Sofía V.
  • Gamella, María
  • García de Frutos, Pablo
  • Batlle, Montserrat
  • Yáñez-Sedeño, Paloma
  • Messina, Germán A.
  • Fernández‐Baldo, Martín A.
  • Campuzano, Susana
  • Pedrero, María
  • Pingarrón, José Manuel
his work reports the first electrochemicalimmunoassay involving magnetic microbeads (MBs) forthe determination of galectin-3 (Gal-3), a -galactosidase-binding lectin that acts as mediator of heart failure (HF).MBs-captured sandwich-type immune complexes andamperometric detection at disposable screen-printed car-bon electrodes were used. The immunoplatform showed adetection limit of 8.3 pgmL 1, good reproducibility, andexcellent selectivity. The endogenous concentration ofGal-3 in human plasma from HF patients was determinedwith results in agreement with those obtained usingELISA. The multiplexing feasibility of the developedimmunoplatform was demonstrated for the simultaneousdetermination of Gal-3 and N-terminal pro-brain natriu-retic peptide (NT-proBNP), This work is part of the POSITION-II project funded bythe ECSEL Joint Undertaking under grant number Ecsel-783132-Position-II-2017-IA; www.position-2.eu, andPID2019-103899RB-I00 (Ministerio de Ciencia e Innova-ción), and of the NANOCARDIOFLEX Project (RetosColaboración RTC-2015-4184-1, cofinanced by the Minis-terio de Economía y Competitividad and FEDER “unamanera de hacer Europa”). The financial support of theRTI2018-096135-B-I00 (Ministerio de Ciencia, Innovacióny Universidades) and PID2019-103899RB-I00 (Ministeriode Ciencia e Innovación) and Research Projects and theTRANSNANOAVANSENS-CM Program from the Co-munidad de Madrid (Grant S2018/NMT-4349) are alsogratefully acknowledged. S.V.P acknowledges the doctor-al fellowship from the Fundación Carolina, Peer reviewed
DIGITAL.CSIC. Repositorio Institucional del CSIC
Publicación Artículo científico (JournalArticle)

Data on clinical characteristics of a heart failure patients' cohort with reduced ejection fraction and analysis of the circulating values of five different heart failure biomarkers; high sensitivity troponin T, galectin-3, C-terminal propeptide of type I procollagen, soluble AXL and BNP

  • Batlle, Montserrat
  • Campos, Begoña
  • Farrero, Marta
  • Cardona, Montserrat
  • González, Beatriz
  • Castel, M. Ángeles
  • Ortiz-Pérez, José T.
  • Roig, Eulalia
  • Pulgarín, M. J.
  • Ramírez, J.
  • Bedini, J. L.
  • Sabaté, Manel
  • García de Frutos, Pablo
  • Pérez-Villa, F.
In this article, the full description of a heart failure with reduced ejection fraction (HF_REF) cohort of 192 patients is provided. Tables with the baseline demographic, prior history, ECG parameters, echocardiographic parameters, laboratory values and pharmacological treatment of these patients are included. Also, the quartile values of the analyzed circulating biomarkers: high sensitivity Troponin T (hs-TnT), galectin-3 (Gal-3), C-terminal propeptide of type I procollagen (CICP), soluble AXL (sAXL) and Brain Natriuretic Peptide (BNP) are given. The main demographic and clinical features of the patients' subgroups that have hs-TnT, Gal-3, CICP or BNP above the third quartile are described. Tables with Pearson correlation analysis of the HF_REF patients' biomarker levels are included. And Pearson correlation analysis of the HF_REF patients' hs-TnT, Gal-3, CICP levels with patients' biochemical parameters, blood count and inflammation parameters are also described. These data are related to the research articles (AXL receptor tyrosine kinase is increased in patients with heart failure (M. Batlle, P. Recarte-Pelz, E. Roig, M.A. Castel, M. Cardona, M. Farrero, et al., 2014) [1] and Use of serum levels of high sensitivity troponin T, galectin-3 and C-terminal propeptide of type I procollagen at long term follow-up in Heart Failure patients with reduced ejection fraction: comparison with soluble AXL and BNP (M. Batlle, B. Campos, M. Farrero, M. Cardona, B. González, M.A. Castel, et al., 2016) [2]., This work was supported by grants from Fundació la Marató de TV3 2008 [project 081010, project 080121]. From Spanish Network on Heart Failure REDINSCOR [V-2006-RET0308-O] and Red de Investigaciones Cardiovasculares RIC [RD12/0042] by Instituto de Salud Carlos III, Ministerio de Sanidad y Consumo and by Fondo Europeo de Desarrollo Regional (FEDER[RD12/0042]) and by a Retos-Colaboración 2015 grant [RTC-2015–4184-1] from Ministerio de Economía y Competitividad., Peer reviewed
Dipòsit Digital de Documents de la UAB
Publicación Artículo científico (JournalArticle)

Data on clinical characteristics of a heart failure patients' cohort with reduced ejection fraction and analysis of the circulating values of five different heart failure biomarkers, high sensitivity troponin T, galectin-3, C-terminal propeptide of type I procollagen, soluble AXL and BNP

  • Batlle, Montserrat|||0000-0002-3034-2023
  • Campos, B.
  • Farrero, Marta|||0000-0002-2404-8821
  • Cardona, Montserrat
  • González, Beatriz
  • Castel, M. A.
  • Ortiz, Joana|||0000-0002-2236-154X
  • Roig, Eulàlia|||0000-0002-3421-4985
  • Pulgarín, M. J.
  • Ramírez, J.
  • Bedini, Josep L.
  • Sabaté Gallego, Mònica|||0000-0001-6206-1085
  • de Frutos, P. García
  • Pérez-Villa, Félix|||0000-0001-9244-938X
In this article, the full description of a heart failure with reduced ejection fraction (HF_REF) cohort of 192 patients is provided. Tables with the baseline demographic, prior history, ECG parameters, echocardiographic parameters, laboratory values and pharmacological treatment of these patients are included. Also, the quartile values of the analyzed circulating biomarkers: high sensitivity Troponin T (hs-TnT), galectin-3 (Gal-3), C-terminal propeptide of type I procollagen (CICP), soluble AXL (sAXL) and Brain Natriuretic Peptide (BNP) are given. The main demographic and clinical features of the patients' subgroups that have hs-TnT, Gal-3, CICP or BNP above the third quartile are described. Tables with Pearson correlation analysis of the HF_REF patients' biomarker levels are included. And Pearson correlation analysis of the HF_REF patients' hs-TnT, Gal-3, CICP levels with patients' biochemical parameters, blood count and inflammation parameters are also described. These data are related to the research articles (AXL receptor tyrosine kinase is increased in patients with heart failure (M. Batlle, P. Recarte-Pelz, E. Roig, M.A. Castel, M. Cardona, M. Farrero, et al., 2014) [1] and Use of serum levels of high sensitivity troponin T, galectin-3 and C-terminal propeptide of type I procollagen at long term follow-up in Heart Failure patients with reduced ejection fraction: comparison with soluble AXL and BNP (M. Batlle, B. Campos, M. Farrero, M. Cardona, B. González, M.A. Castel, et al., 2016) [2].
Dipòsit Digital de Documents de la UAB
Publicación Artículo científico (JournalArticle)

Organic-based field effect transistors for protein detection fabricated by inkjet-printing

  • Martinez Domingo, Carme|||0000-0002-1897-5362
  • Conti, Silvia
  • De La Escosura-Muñiz, Alfredo|||0000-0002-9600-0253
  • Terés, Lluís
  • Merkoçi, Arben|||0000-0003-2486-8085
  • Ramon, Eloi|||0000-0001-9974-8112
Biosensors based on Organic Field-Effect Transistors (OFETs) have attracted increasing attention due to the possibility of rapid, label-free, and inexpensive detection. Among all the different possibilities, inkjet-printed top-gate organic Field Effect Transistors-Based Biosensors (BioFETs) using a polymeric gate insulator have been seldom reported. In this work, a systematic investigation in terms of topographical and electrical characterization was carried out in order to find the optimal fabrication process for obtaining a reliable polymer insulator. Previous studies have demonstrated that the best electrical performance arises from the use of the perfluoropolymer Cytop™[12,13,14]. Consequently, a simple immobilization protocol was used to ensure the proper attachment of a model biomolecule onto the Cytop's hydrophobic surface whilst keeping its remarkable insulating properties with gate current in the range of dozens of pico-amperes. The top-gate inkjet-printed BioFETs presented in this study operate at threshold voltages in the range of 1-2 V and show durability even when exposed to oxygen plasma, wet amine functionalization treatments, and aqueous media. As a preliminary application, the inkjet-printed top-gate BioFETs is used for monitoring an immunoreaction by measuring changes in the drain current, paving the way for further use of this device in the immunosensing field.