DIGITAL.CSIC. Repositorio Institucional del CSIC
Publicación
Artículo científico (JournalArticle)
Comparative evaluation of the performance of electrochemical immunosensors using magnetic microparticles and nanoparticles. Application to the determination of tyrosine kinase receptor AXL
Electrochemical sandwich immunoassay strategies involving the use of carboxyl-functionalized magnetic microbeads (cMBs) and magnetic nanoparticles (cMNPs) have been evaluated and compared. The proteolytically cleaved soluble tyrosine kinase receptor sAXL was used as the target analyte. Antibodies against AXL were covalently immobilized on cMBs or cMNPs. Immunobinding of AXL was detected by means of a secondary biotinylated antibody and a streptavidin-horseradish peroxidase conjugate. The electrochemical transduction was accomplished by capturing the cMBs or cMNPs bearing the immunoconjugates onto screen-printed carbon electrodes (SPCEs) by using a small magnet. The amperometric response was measured at −0.20 V (vs the silver pseudo-reference electrode of the SPCE) upon the addition of H2O2 in the presence of hydroquinone as the redox mediator. The calibration plots for AXL extended up to 7.5 ng mL−1 when cMBs were used for the preparation of the immunosensor and up to 40 ng mL−1 in the case of using cMNPs. The respective slope values were 158 (cMBs) and 43 nA mL ng−1 (cMNPs), while the achieved LODs were 74 (cMBs) and 75 pg mL−1 (cMNPs). Although the immunosensors prepared with cMBs provided a shorter range of linearity, they exhibited a 3.7-times larger sensitivity than those constructed with cMNPs. The successful application of the new strategies was demonstrated for the determination of the endogenous content of sAXL in real human serum samples (a cut-off value of 71 ng mL−1 have been established for patients with risk of heart failure). The immunosensors constructed using cMBs or cMNPs can be advanta geously compared, in terms of sensitivity and fabrication time, with the only immunosensor for AXL previously reported. In addition, these new immunosensors took approximately half time than ELISA to perform the assay., The financial support of projects: Retos
Colaboración RTC-2015-4184-1 (cofinanced by the Ministry of
Economy and Competitivity and FEDER Buna manera de hacer
Europa^), CTQ2015-70023-R and CTQ2015-64402-C2-1-R (Spanish
Ministry of Economy and Competitivity Research Projects) and S2013/
MT-3029 (NANOAVANSENS Program from the Comunidad de Madrid)
are gratefully acknowledged. R.M. Torrente-Rodríguez acknowledges a
predoctoral contract from the Spanish Ministry of Economy and
Competitivity, Peer reviewed
Proyecto:
MINECO / Plan Estatal de Investigación Científica y Técnica y de Innovación 2013-2016 RTC-2015-4184-1
,
MINECO / Plan Estatal de Investigación Científica y Técnica y de Innovación 2013-2016 CTQ2015-70023-R
,
MINECO / Plan Estatal de Investigación Científica y Técnica y de Innovación 2013-2016 CTQ2015-64402-C2-1-R