Pasar al contenido principal

PROTECCION ACTIVA Y FABRICACION ADITIVA DE ALEACIONES LIGERAS

RTI2018-096391-B-C33

•
Nombre agencia financiadora Agencia Estatal de Investigación
Acrónimo agencia financiadora AEI
Programa Programa Estatal de I+D+i Orientado a los Retos de la Sociedad
Convocatoria Proyectos I+D+i Retos de Investigación
Año convocatoria 2018
Plan Estatal 2017-2020 Plan Estatal de Investigación Científica y Técnica y de Innovación
Centro beneficiario UNIVERSIDAD COMPLUTENSE DE MADRID

Resultados relacionados

Resultados totales (Incluyendo duplicados): 5
Encontrada(s) 1 página(s)

DIGITAL.CSIC. Repositorio Institucional del CSIC
Publicación Artículo científico (JournalArticle)

Hybrid functionalized coatings on Metallic Biomaterials for Tissue Engineering

  • Santos-Coquillat, A.
  • Martínez-Campos, Enrique
  • Mora Sánchez, H.
  • Moreno Capellán, Laura
  • Arrabal, R.
  • Mohedano, M.
  • Gallardo Ruiz, Alberto
  • Rodríguez-Hernández, Juan
  • Matykina, E.
The review encompasses state-of-the-art strategies for design and fabrication of smart biomaterials for tissue engineering. The focus of the work is mainly put on metallic biomaterials with hybrid coatings consisting of bioceramic and polymeric layers with hierarchical organization and drug-eluting capacity. Key technologies and steps to design hybrid smart and multifunctional coatings on metallic cores for bone regeneration implants and cardiovascular stents are outlined, including additive manufacturing of titanium and magnesium alloys for permanent and temporary implant applications. Three levels of hierarchical surface functionalization are described: i) in situ modification of the core material, incorporating bioactive inorganic species and phases by means of ceramic coatings via anodic electrochemical treatments; ii) post-treatment application of polymer layers, monolithic or with specific porous breath figure topography; and iii) application of a cellular therapy component (single cell or cell sheet). Recent progress in incorporation of drug-eluting functionality into such materials via direct or nanocarrier-assisted loading is also highlighted., The authors gratefully acknowledge the support of the RTI2018- 096391-B-C33 (MCIU/AEI/FEDER, UE) and ADITIMAT-CM (S2018/ NMT-4411) projects. M. Mohedano and H. Mora-S ́anchez are grateful for the support of RYC-2017 21843 and PEJD-2019-POST/IND-16119, respectively. A. Santos-Coquillat is grateful for financial support from Ministerio de Ciencia e Innovación, Instituto de Salud Carlos III Sara Borrell Fellowship CD19/00136. Equally, this work was financially supported by the Ministerio de Ciencia e Innovación (RTI2018-096328- B-I00).
DIGITAL.CSIC. Repositorio Institucional del CSIC
Publicación Artículo científico (JournalArticle)

Review of plasma electrolytic oxidation of titanium substrates: Mechanism, properties, applications and limitations

  • Aliofkhazraei, M.
  • Macdonald, D. D.
  • Matykina, E.
  • Parfenov, E. V.
  • Egorkin, V. S.
  • Curran, J. A.
  • Troughton, S. C.
  • Sinebryukhov, S. L.
  • Gnedenkov, S. V.
  • Lampke, T.
  • Simchen, F.
  • Nabavi, H. F.
The plasma electrolytic oxidation is an innovative method for the surface treatment of titanium and its alloys. This review provides an overview of the historical development of the process and summarizes the current state of the art. The chemical as well as the electro- and plasma-chemical basics of the layer forming mechanisms, which comprises the substrate/electrolyte interface before discharge initiation and the different types and stages of plasma electrolytic discharge phenomena are explained within the context of titanium-based materials. How these phenomena can be influenced by the use of suitable electrolytes and controlled by the electrical regime is described. Subsequently, the microstructures and composition of the layers are described in detail, and the properties for specific applications are then discussed. The resistance of a PEO coating to corrosive environments, tribological factors, and alternating mechanical stress is viewed critically, and the extensive functional properties such as physiological compatibility, photocatalytic activity, and decorative properties are revealed. Finally, examples of various practical applications in the medical engineering, aviation, automotive, and environmental technology fields, as well as other branches of industry, are presented., M. Aliofkhazraei acknowledges comments received from Prof. A. Yerokhin during intial steps of preparation of this review paper. D.D. Macdonald gratefully acknowledges the support of the FUTURE (Fundamental Understanding of Transport Under Reactor Extremes), an Energy Frontier Research Center funded by the U.S. Department of En- ergy (DOE), Office of Science, Basic Energy Sciences (BES). E. Matykina would like to thank the support of the RTI2018-096391-B-C33 (MCIU/ AEI/FEDER, UE) and S2018/NMT-4411 (Regional Government of Madrid and EU Structural and Social Funds). S.V. Gnedenkov ac- knowledges the support of the Russian Science Foundation (No. 20-13- 00130).
DIGITAL.CSIC. Repositorio Institucional del CSIC
Publicación Artículo científico (JournalArticle)

Anticorrosion and Cytocompatibility Assessment of Graphene-Doped Hybrid Silica and Plasma Electrolytic Oxidation Coatings for Biomedical Applications

  • Fernández-Hernán, J. P.
  • López, A. J.
  • Torres, Belén
  • Martínez-Campos, Enrique
  • Matykina, E.
  • Rams, J.
Magnesium AZ31 alloy substrates were coated with different coatings, including sol-gel silica-reinforced with graphene nanoplatelets, sol-gel silica, plasma electrolytic oxidation (PEO), and combinations of them, to improve cytocompatibility and control the corrosion rate. Electrochemical corrosion tests, as well as hydrogen evolution tests, were carried out using Hanks' solution as the electrolyte to assess the anticorrosion behavior of the different coating systems in a simulated body fluid. Preliminary cytocompatibility assessment of the different coating systems was carried out by measuring the metabolic activity, deoxyribonucleic acid quantification, and the cell growth of premyoblastic C2C12-GFP cell cultures on the surface of the different coating systems. Anticorrosion behavior and cytocompatibility were improved with the application of the different coating systems. The use of combined PEO + SG and PEO + SG/GNP coatings significantly decreased the degradation of the specimens. The monolayer sol-gel coatings, with and without GNPs, presented the best cytocompatibility improvement., The authors would like to acknowledge the financial support from the Ministerio de Ciencia e Innovación for the FPI grant (MAT2015-66334-C3-1-R), Agencia Estatal de Investigación (project RTI2018-096391-B-C31 and RTI2018-096391-B-C33), and the Comunidad de Madrid (project ADITIMAT-CM S2018/NMT-4411).
DIGITAL.CSIC. Repositorio Institucional del CSIC
Publicación Artículo científico (JournalArticle)

Quasi-in vivo corrosion behavior of AZ31B Mg alloy with hybrid MWCNTs-PEO/PCL based coatings

  • Daavari, Morteza
  • Atapour, Masoud
  • Mohedano, Marta
  • Mora Sánchez, Hugo
  • Rodríguez-Hernández, Juan
  • Matykina, Endzhe
  • Arrabal, Raúl
  • Taherizadeh, Aboozar
This study investigated the effects of multi-walled carbon nanotubes (MWCNTs) and polycaprolactone (PCL) on the quasi-in vivo corrosion behavior of AZ31B Mg alloy treated by plasma electrolytic oxidation (PEO). Thin (∼2 µm, PCTPCL4) and thick (∼60 µm, PCTPCL6) PCL layers were applied only onto the MWCNTs-PEO coating (PCT) as it showed better corrosion performance. Findings reveal that incorporation of MWCNTs induced several structural and functional modifications in the PEO coating, such as increased roughness, a thicker inner barrier layer, and reduced hydrophilicity. Quasi-in vivo corrosion testing was carried out under controlled temperature, pH, and fluid flow in simulated body fluid (SBF) by electrochemical impedance spectroscopy (EIS) and hydrogen evolution experiments. EIS results revealed that, after 48 h immersion, a diffusion process controlled hydration of the ceramic coatings. Comparison of the collected hydrogen after 15 days of immersion in the quasi-in vivo environment revealed that the PEO and PCT ceramic coatings decreased hydrogen generation by up to 74% and 91%, respectively, compared to non-coated alloy. PCTPCL6 coating exhibited the lowest amount of collected hydrogen (0.2 mL/cm). The thick PCL layer delayed the onset of substrate corrosion for at least 120 h, reducing the corrosion rate by 85% compared with the PCT., The authors gratefully acknowledge the financial support of the Iran National Science Foundation INSF (Grant No. 97014179). This work was also supported by RTI2018–096391-B-C33 (MCIU/AEI/FEDER, UE) and S2018/NMT-4411 (Regional government of Madrid and EU Structural and Social Funds). M. Mohedano is grateful for the support of RYC-2017–21843. We also gratefully acknowledge financial support from the Spanish National Science Foundation (CSIC) and the Ministerio de Ciencia, Innovación y Universidades (MINECO) grant number RTI2018–096328-B-I00. The technical support from Dr. Mariona Cabero during the preparation of TEM cross-section specimens is gratefully acknowledged.
DIGITAL.CSIC. Repositorio Institucional del CSIC
Publicación Otros (Other)

New Trends in the Design of Biomaterials for 3D and 4D Printing

  • Olmo, Rubén del
  • Martínez-Campos, Enrique
  • Relinque, José Javier
  • Gallardo, Alberto
  • Juan Rodríguez-Hernández
  • Endzhe Matykina
  • Ana Santos-Coquillat
Additive manufacturing (AM), also known as 3D printing, is today a widely used technology in the fabrication of complex-shaped biomaterials from Digital computer-aided (CAD) designs. In this context, 3D fabrication responds to the increasing demand for new scaffolds with tailor-made architectures with the potential for tissue regeneration, including structures specially designed for the vasculariza tion of scaffolds. This chapter aims to provide an overview of the state-of-the-art, current, and future perspectives in the field of biomaterials AM with their actual technological limitations and biovalidation strategies, i.e., from the manufacturing process technology to the direct biomedical applications. Up until now, AM can also improve prosthetics with biometric characteristics with patient-specific anatomical data or facilitate the creation of a new organ (liver, lymphoid organs). Another appli cation is in vitro drug testing (liberation studies, etc.) with 3D-printed models of anatomical parts. So far, the latest advances reveal that material selection and AM printing technology are the most critical factors in achieving the most clinical success rate according to the patient’s needs. Moreover, AM of composite materials stands., The funding of the ADITIMAT-CM project (S2018/NMT-4411, Regional Government of Madrid and EU Structural and Social Funds), CSIC (PIE 202060E096, and 202060E239) and RTI2018-096391-B-C33 (MCIU/AEI/FEDER, UE) are gratefully acknowl edged. J. J. Relinque acknowledges the Spanish Ministry of Universities for his Margarita Salas Universidad de Cádiz 2021 Postdoctoral Fellowship. R. del Olmo acknowledges Marie Skłodowska Curie Postdoctoral Fellowship (MSCA-PF), grant ID 101066947; EU651 project. A. Santos Coquillat is grateful for financial support from Fonds de la Recherche Scientifique (F.R.S.-FNRS) as Chargée de recherches., Peer reviewed