Skip to main content

Resultados relacionados

Resultados totales (Incluyendo duplicados): 9
Encontrada(s) 1 página(s)

RUA. Repositorio Institucional de la Universidad de Alicante
Publication Otros (Other)

How Reproducible are Surface Areas Calculated from the BET Equation?

  • Osterrieth, Johannes W. M.
  • Rampersad, James
  • Madden, David G.
  • Rampal, Nakul
  • Skoric, Luka
  • Connolly, Bethany M.
  • Allendorf, Mark D.
  • Stavila, Vitalie
  • Snider, Jonathan L.
  • Ameloot, Rob
  • Marreiros, João
  • Coudert, François-Xavier
  • Cui, Yong
  • Hou, Bang
  • D'Alessandro, Deanna M.
  • Doheny, Patrick W.
  • Dincă, Mircea
  • Sun, Chenyue
  • Doonan, Christian
  • Huxley, Michael Thomas
  • Evans, Jack D.
  • Bara, Dominic
  • Falcaro, Paolo
  • Ricco, Raffaele
  • Farha, Omar
  • Idrees, Karam B.
  • Islamoglu, Timur
  • Feng, Pingyun
  • Yang, Huajun
  • Forgan, Ross S.
  • Furukawa, Shuhei
  • Sanchez, Eli
  • Gascon, Jorge
  • Telalović, Selvedin
  • Ghosh, Sujit K.
  • Mukherjee, Soumya
  • Hill, Matthew R.
  • Sadiq, Muhammed Munir
  • Horcajada, Patricia
  • DeWitt, Stephen J. A.
  • Salcedo-Abraira, Pablo
  • Kaneko, Katsumi
  • Kukobat, Radovan
  • Kenvin, Jeff
  • Keskin, Seda
  • Kitagawa, Susumu
  • Otake, Ken-ichi
  • Lively, Ryan P.
  • Llewellyn, Phillip L.
  • Lotsch, Bettina V.
  • Emmerling, Sebastian T.
  • Pütz, Alexander M.
  • Martí-Gastaldo, Carlos
  • Padial, Natalia M.
  • Garcia-Martinez, Javier
  • Linares, Noemi
  • Maspoch, Daniel
  • Rosseinsky, Matthew J.
  • Suárez del Pino, Jose A.
  • Moghadam, Peyman Z.
  • Oktavian, Rama
  • Morris, Russel E.
  • Wheatley, Paul S.
  • Navarro, Jorge
  • Petit, Camille
  • Danaci, David
  • Katsoulidis, Alexandros P.
  • Schröder, Martin
  • Han, Xue
  • Yang, Sihai
  • Serre, Christian
  • Mouchaham, Georges
  • Sholl, David S.
  • Thyagarajan, Raghuram
  • Siderius, Daniel
  • van der Veen, Monique A.
  • Snurr, Randall Q.
  • Goncalves, Rebecca B.
  • Telfer, Shane
  • Lee, Seok J.
  • Ting, Valeska P.
  • Rowlandson, Jemma L.
  • Uemura, Takashi
  • Iiyuka, Tomoya
  • Rega, Davide
  • Van Speybroeck, Veronique
  • Rogge, Sven M.J.
  • Lamaire, Aran
  • Walton, Krista S.
  • Bingel, Lukas W.
  • Wuttke, Stefan
  • Andreo, Jacopo
  • Yaghi, Omar
  • Ania, Conchi O.
  • Zhang, Bing
  • Yavuz, Cafer T.
  • Nguyen, Thien S.
  • Zamora, Félix
  • Montoro, Carmen
  • Zhou, Hongcai
  • Kirchon, Angelo
  • Fairen-Jimenez, David
  • Azevedo, Diana
  • Vilarrasa-García, Enrique
  • Santos, Bianca F.
  • Bu, Xian-He
  • Chang, Ze
  • Bunzen, Hana
  • Champness, Neil R.
  • Griffin, Sarah L.
  • Chen, Banglin
  • Lin, Rui-Biao
  • Coasne, Benoit
  • Cohen, Seth
  • Moreton, Jessica C.
  • Colón, Yamil J.
  • Chen, Linjiang
  • Clowes, Rob
  • Garcia-Martinez, Javier|||/items/421c2466-c63a-45d7-b799-c59d51faf1bc
  • Linares, Noemi|||/items/b74614e6-be98-4729-84e5-256605124c99
Porosity and surface area analysis play a prominent role in modern materials science. At the heart of this sits the Brunauer–Emmett–Teller (BET) theory, which has been a remarkably successful contribution to the field of materials science. The BET method was developed in the 1930s for open surfaces but is now the most widely used metric for the estimation of surface areas of micro- and mesoporous materials. Despite its widespread use, the calculation of BET surface areas causes a spread in reported areas, resulting in reproducibility problems in both academia and industry. To prove this, for this analysis, 18 already-measured raw adsorption isotherms were provided to sixty-one labs, who were asked to calculate the corresponding BET areas. This round-robin exercise resulted in a wide range of values. Here, the reproducibility of BET area determination from identical isotherms is demonstrated to be a largely ignored issue, raising critical concerns over the reliability of reported BET areas. To solve this major issue, a new computational approach to accurately and systematically determine the BET area of nanoporous materials is developed. The software, called “BET surface identification” (BETSI), expands on the well-known Rouquerol criteria and makes an unambiguous BET area assignment possible.
DIGITAL.CSIC. Repositorio Institucional del CSIC
Publication Otros (Other)

Label-free plasmonic biosensor for rapid, quantitative, and highly sensitive COVID-19 serology: implementation and clinical validation

  • Calvo-Lozano, Olalla
  • Sierra, Miquel
  • Soler, María
  • Estévez, M. Carmen
  • Chiscano- Camón, Luis
  • Ruiz-Sanmartín, Adolfo
  • Ruiz-Rodriguez, Juan Carlos
  • Ferrer, Ricard
  • González-López, Juan José
  • Esperalba, Juliana
  • Fernández-Nava, Candela
  • Bueno, Leticia
  • López-Aladid, Rubén
  • Torres, Antoni
  • Fernández-Barat, Laia
  • Attoumani, Sarah
  • Charrel, Remi
  • Coutard, Bruno
  • Lechuga, Laura M.
Serological tests are essential for the control and management of COVID-19 pandemic, not only for current and historical diagnostics but especially for surveillance, epidemiological, and acquired immunity studies. Clinical COVID-19 serology is routinely performed by enzymatic or chemiluminescence immunoassays (i.e., ELISA or CLIA), which provide good sensitivities at the expense of relatively long turnaround times and specialized laboratory settings. Rapid serological tests, based on lateral flow assays, have also been developed and widely commercialized, but they suffer from limited reliability due to relatively low sensitivity and specificity. We have developed and validated a direct serological biosensor assay employing proprietary technology based on Surface Plasmon Resonance (SPR). The biosensor offers a rapid -less than 15 min- identification and quantification of SARS-CoV-2 antibodies directly in clinical samples, without the need of any signal amplification. The portable plasmonic biosensor device employs a custom-designed multi-antigen sensor biochip, combining the two main viral antigens (RBD peptide and N protein), for simultaneous detection of human antibodies targeting both antigens. The SPR serology assay reaches detection limits in the low ng mL-1 range employing polyclonal antibodies as standard, which are well below the commonly detected antibody levels in COVID-19 patients. The assay has also been implemented employing the first WHO approved anti-SARS-CoV-2 immunoglobulin standard. We have carried out a clinical validation with COVID-19 positive and negative samples (n=120) that demonstrates the excellent diagnostic sensitivity (99%) and specificity (100%). This positions our biosensor device as an accurate, robust, and easy-to-use diagnostics tool for rapid and reliable COVID-19 serology to be employed both at laboratory and decentralized settings for the management of COVID-19 patients and for the evaluation of immunological status during vaccination, treatment or in front of emerging variants., H2020 Research and Innovation Programme of the European Commission Project, No. 101003544 Spanish Research Agency (AEI, grant no. SEV-2017-0706AEI, grant no. SEV-2017-0706) Spanish Ministry of Science and Innovation and the Spanish Research Agency and the European Social Fund (ESF)BES-2017-080527 GENCAT-DGRIS COVID EU H2020 Programme (644956) Plan Nacional de I+D+i 2013-2016 ISCIII- Ministerio de Ciencia e Innovación, Vall d’Hebron University Hospital Biobank PT17/0015/0047 European Virus Archive GLOBAL (EVA-GLOBAL) EU Horizon 2020 (grant agreement No. 871029) Fundació Glòria Soler for COVIDBANK collection Spanish Network for Research in Infectious Diseases (REIPI RD16/0016/0003), No
DIGITAL.CSIC. Repositorio Institucional del CSIC
Publication Otros (Other)

Electrical control of spin-polarized topological currents in monolayer WTe2

  • Garcia, Jose H.
  • You, Jinxuan
  • García-Mota, Mónica
  • Koval, Peter
  • Ordejón, Pablo
  • Cuadrado, Ramón
  • Verstraete, Matthieu J.
  • Zanolli, Zeila
  • Roche, Stephan
We evidence the possibility for coherent electrical manipulation of the spin orientation of topologically protected edge states in a low-symmetry quantum spin Hall insulator. By using a combination of ab initio simulations, symmetry-based modeling, and large-scale calculations of the spin Hall conductivity, it is shown that small electric fields can efficiently vary the spin textures of edge currents in monolayer 1T'-WTe2 by up to a 90-degree spin rotation, without jeopardizing their topological character. These findings suggest a new kind of gate-controllable spin-based device, topologically protected against disorder and of relevance for the development of topological spintronics., Supported by the EU H2020 Programme under Grants No. 881603 (Graphene Flagship), No 824140 (TOCHA, H2020-FETPROACT-01-2018), and No. 824143 (MaX Materials Design at the Exascale CoE) and by Sgrants PGC2018- 096955-B-C43 funded by MCIN/AEI/ 10.13039/501100011033 and by ERDF A way of making Europe and PCI2018-093120 funded by MCIN/AEI/ 10.13039/501100011033. Z.Z. acknowledges financial support by the by the Ramon y Cajal program RYC-2016-19344 (MINECO/AEI/FSE, UE), Netherlands Sector Plan program 20192023 and the NWO Gravitation programme “Materials for the Quantum Age” (QuMat) funded by the Ministry of Education, Culture and Science of the government of the Netherlands. R.C. acknowledges the funding from the EU H2020 Programme under the Marie Sklodoswka–Curie Grant No. 665919. J.Y., P.K., M.G.M., and Z.Z. acknowledge the computer resources at MareNostrum and the technical support provided by the Barcelona Supercomputing Center through Red Española de Supercomputación (Grants No. RES-FI-2020-1-0018, No. RES-FI-2020-1-0014, and No. RES-FI-2020-2-0039). M.J.V. acknowledges the Fonds de la Recherche Scientifique (FRS-FNRS Belgium) for PdR Grant No. T.0103.19 - ALPS, and ARC project DREAMS (G.A. 21/25-11) funded by Fedeŕation Wallonie Bruxelles and ULieǵe. ICN2 is funded by the Generalitat de Catalunya (CERCA Programme and Grants No. 2017SGR1506 and No. 2017SGR692), and is supported by the Severo Ochoa Centers of Excellence Program from Spanish MINECO under Grant No. SEV-2017-0706. We acknowledge a PRACE award granting access to MareNostrum4 at Barcelona Supercomputing Center (BSC), Spain (OptoSpin project id. 2020225411)., Peer reviewed
DIGITAL.CSIC. Repositorio Institucional del CSIC
Publication Otros (Other)

ATP Sensing Paper with Smartphone Bioluminescence-Based Detection

  • Calabretta, Maria Maddalena
  • Álvarez-Diduk, Ruslan
  • Michelini, Elisa
  • Merkoçi, Arben
Adenosine-5'-triphosphate (ATP) is the primary energy carrier in all living organisms, and its detection in living cells represents a well-established approach. ATP-driven bioluminescence (BL) relying on the D-luciferin-luciferase reaction is a bioanalytical tool widely employed for monitoring hygiene and microbial contamination of foods.Here, we report a straightforward method for ATP BL detection using an ATP sensing paper fabricated with an alternative freeze-dry procedure. The assay can be easily implemented in laboratories equipped with (i) freeze-drying, wax printing, and 3D printing technologies and (ii) instrumentation for BL detection such as benchtop luminometers and portable light detectors including a smartphone camera without the need for additional equipment., Elisa Michelini acknowledges support by MIUR and Prima (Partnership for Research and Innovation in the Mediterranean Area) with FEDKITO project. ICN2 is funded by CERCA programme, Generalitat de Catalunya. Grant SEV-2017-0706 funded by MCIN/AEI/10.13039/501100011033., Peer reviewed
DIGITAL.CSIC. Repositorio Institucional del CSIC
Publication Otros (Other)

Optical smartphone-based sensing: diagnostic of biomarkers

  • Hu, Liming
  • Idili, Andrea
  • Parolo, Claudio
  • Álvarez-Diduk, Ruslan
  • Calucho, Enric
  • Merkoçi, Arben
Biomarkers are nucleic acids, peptides, proteins, lipids metabolites, or other small molecules in human tissues or biological fluids whose accurate detection contributes to the prediction and determination of diseases and their status. In recent years, platforms that allow the detection of important biomarkers at the point-of-care (PoC) are moving the field of diagnostics towards personalized medicine. In order to comply with the REASSURED criteria stated by the WHO, the most efficient solution is to integrate PoC devices with smartphones. Without a doubt the smartphone camera is a “smart detector,” and almost all the optical-based methods have been integrated, including absorbance, fluorescence, microscopic bio-imaging, surface plasmon resonance, chemiluminescence, bioluminescence, and photoluminescence. In this chapter, we explain how smartphones can be used as smart detectors in diagnostic devices and we will provide an overview of recent developments of smartphone-based optical PoC devices., A.M. acknowledge FEDER/Ministerio de Ciencia, Innovación y Universidades - Agencia Estatal de Investigación/_Project MAT2017-87202-P. A.M. also acknowledge ICN2 which is funded by the CERCA programme/Generalitat de Catalunya and supported by the Severo Ochoa Centres of Excellence programme that is funded by the Spanish Research Agency (AEI, grant no. SEV-2017-0706). A.M, L.H., A.I., C.P., R.A. and E.C. acknowledge Autonomous University of Barcelona (UAB) for their support. E.C. acknowledges Ministerio de Ciencia e Innovación of Spain and Fondo Social Europeo for the Fellowship PRE2018–084856 under the framework of “Plan Estatal de Investigación Científica y Técnica y de Innovación 2017–2020. L. H. acknowledges China Scholarship Council which is a non-profit institute affiliated with the Ministry of Education of the P. R. China. A.I. was supported by PROBIST postdoctoral fellowship funded by European Research Council (Marie Skłodowska-Curie grant agreement No. 754510)., Peer reviewed
DIGITAL.CSIC. Repositorio Institucional del CSIC
Publication Otros (Other)

Ultrasensitive Label-Free Nucleic-Acid Biosensors Based on Bimodal Waveguide Interferometers

  • Huertas, César S.
  • Lechuga, Laura M.
The bimodal waveguide (BiMW) biosensor is an innovative common path interferometric sensor based on the evanescent field detection principle. This biosensor allows for the direct detection of virtually any biomolecular interaction in a label-free scheme by using specific biorecognition elements. Due to its inherent ultrasensitivity, it has been employed for the monitoring of relevant nucleic-acid sequences such as mRNA transcripts or microRNAs present at the attomolar-femtomolar concentration level in human samples. The application of the BiMW biosensor to detect these nucleic acids can be a powerful analytical tool for diagnosis and prognosis of complex illnesses, such as cancer, where these biomarkers play a major role. The BiMW sensor is fabricated using standard silicon-based microelectronics technology, which allows its miniaturization and cost-effective production, meeting the requirements of portability and disposability for the development of point-of-care (PoC) sensing platforms. In this chapter, we describe the working principle of the BiMW biosensor as well as its application for the analysis of nucleic acids. Concretely, we show a detailed description of DNA functionalization procedures and the complete analysis of two different RNA biomarkers for cancer diagnosis: (1) the analysis of mRNA transcripts generated by alternative splicing of Fas gene, and (2) the detection of miRNA 181a from urine liquid biopsies, for the early diagnosis of bladder cancer. The biosensing detection is performed by a direct assay in real time, by monitoring the changes in the intensity pattern of the light propagating through the BiMW biosensor, due to the hybridization of the target with the specific DNA probe previously functionalized on the BiMW sensor surface., ICN2 is supported by the “Severo Ochoa Centers of Excellence” Program from the Spanish Ministry of Science (MINECO) (Grant No. SEV-2017-0706). Dr. Cesar S. Huertas is a recipient of an RMIT Vice Chancellor’s Postdoctoral Fellowship., Peer reviewed
DIGITAL.CSIC. Repositorio Institucional del CSIC
Publication Otros (Other)

Signal enhancement strategies

  • Yang, Qiuyue
  • Nguyen, Emily P.
  • Castro Silva, Cecilia de Carvalho
  • Rosati, Giulio
  • Merkoçi, Arben
As modern society progresses, advancements in digital and personalized healthcare have evolved from the more analogues ways to an inherent need for point-of-care devices. Besides, the evolution of miniaturized electronics or silicon-based technology, microfluidics has also been instrumental to the development these flexible and wearable devices and has amassed intense interest over the last few decades. In this chapter, the use of microfluidics for sample collection (sampling) in wearables is discussed, with a brief description of the approaches for microfluidic device fabrication, as well as the various types of sample matrices (bodily fluids) that can be collected. Then signal-amplification strategies for wearables are presented, focusing on the unique characteristics and integration of novel nanomaterials., ICN2 is funded by the CERCA program/Generalitat de Catalunya. The ICN2 is supported by the Severo Ochoa Centres of Excellence program, funded by the Spanish Research Agency (AEI, grant no. SEV-2017-0706). EPN acknowledges funding through the EU’s Horizon 2020 research and innovation program under the Marie Skłodowska-Curie grant agreement No. 754510. CCCS acknowledges funding through CAPES—PRINT (Programa Institucional de Internacionalização; Grant # 88887.310281/2018-00 and 88887.467442/2019-00)., Peer reviewed
DIGITAL.CSIC. Repositorio Institucional del CSIC
Publication Otros (Other)

Conductive properties of triphenylene porous coordination polymers

  • Contreras-Pereda, Noemí
  • Ruiz Molina, Daniel
Triphenylene (TP)-based materials have been greatly exploited lately. The compelling optoelectronic characteristics of TP derivatives as a consequence of the aromaticity of moiety allowed the expansion of functional two-dimensional (2D) porous coordination polymers (PCPs). The properties of these materials and performance of their derived functional devices strongly depend on their synthetic approach, defining their morphology, crystallinity, and orientation, among others. Thus in this chapter we will summarize the different synthetic procedures to obtain TP-based 2D PCPs, detailing the morphological characteristics as crystalline domain and orientation obtained with each methodology. We also present a vast range of 2D TP-based PCP structures focusing on their electronic properties as well as emphasizing the effects of intralayer (in-plane) and interlayer (out-of-plane) charge transport on the electrical conductivity of each chemical and crystalline structure. Finally, we will introduce the principal and diverse applications of functional devices including these materials present in the literature., This work was supported by grant RTI2018–098027-B-C21 from the Spanish Government funds and by the European Regional Development Fund (ERDF). The ICN2 is funded by the CERCA Programme/Generalitat de Catalunya. The ICN2 is supported by the Severo Ochoa Centres of Excellence Programme and funded by the Spanish Research Agency (AEI, Grant No. SEV-2017–0706). N. C.-P. acknowledges the support of fellowship from “laCaixa” Foundation (ID 100010434). The fellowship code is LCF/BQ/ES17/11600012., With funding from the Spanish government through the "Severo Ochoa Centre of Excelence" accreditation (SEV-2017–0706), Peer reviewed
DIGITAL.CSIC. Repositorio Institucional del CSIC
Publication Otros (Other)

Strain in Halide Perovskites and Solar Cell Stability: Accelerated Stress Tests under Bias Voltage

  • Baumann, Fanny
  • Karimipour, Masoud
  • Padilla-Pantoja, Jessica
  • Chávez-Angel, Emigdio
  • Caicedo, José Manuel
  • Pouteaux, Rémy
  • Alcalá Ibarra, Alex
  • Raga, Sonia R.
  • Santiso, José
  • Lira-Cantú, Mónica
The lifespan of halide perovskite solar cells (PSCs) is currently a major concern for the implementation and commercialization of the technology. Tensile and compressive strain alters the halide perovskite (HP) lattice under operando conditions, affecting PSC stability. However, the mechanisms governing strain responses are still unknown. In this work, we monitored the evolution of strain in PSCs during accelerated stability tests under continuous light irradiation and bias-voltage. Additive engineering led to a compression of the HP lattice, improving PSC stability. The temporal evolution of the HP lattice, together with the electrical response of devices employing modified and reference HP, was tracked by in situ X-ray diffraction, photoluminescence, and quasi in situ electrochemical impedance spectroscopy. Our results demonstrate a good correlation between lattice expansion (strain) and the device's current decay and stability. Additionally, and contrary to the current understanding, we observed that lattice compression in HP was not sufficient to ensure protection against degradation., We thank Prof. Anita Ho-Baillie and Dr. Jae Sung Yun for constructive comments on electrode fabrication. This work was supported by the Spanish Ministry of Science and Innovation (MCIN) and the AEI under the Project No. PID2022-143344OB-I00. This work constitutes part of the Materials Science Ph.D. Program for F.B. at the Universitat Autonoma de Barcelona (UAB, Spain), and the authors acknowledge the Spanish Ministry of Science and Innovation for providing the predoctoral contract to F.B. with reference No. PRE2020-092669 of the Project No. SEV-2017-0706-20-3. S.R.R. acknowledges the support from “la Caixa” Foundation (ID 100010434) with fellowship LCF/BQ/PI20/11760024 and Grant PID2021-122349OAI00 funded by MCIN/AEI/10.13039/501100011033 and “ERDF A way of making Europe. ICN2, including the postdoctoral contract to M.K., was supported by the Severo Ochoa program from Spanish MINECO (grant no. SEV-2017-0706) and is funded by the CERCA Programme/Generalitat de Catalunya. Thanks are extended to Agencia de Gestio d’Ajuts Universitaris i de Recerca for Grant No. SGR 01617 and the Xarxa d’ R + D + I Energy for Society. The ICN2 is supported by the Severo Ochoa Centres of Excellence programme, Grant CEX2021-001214-S, funded by MCIN/AEI/10.13039.501100011033. E.C.A. acknowledges support from MCIN with funding from European Union NextGenerationEU (PRTR-C17.I1) and Generalitat de Catalunya. We would like to thank Dámaso Torres for his assistance with graphical design., With funding from the Spanish government through the "Severo Ochoa Centre of Excelence" accreditation (CEX2021-001214-S), Peer reviewed