Skip to main content

NANODIAGNOSTICO RENTABLE E INTELIGENTE INTEGRADO

MAT2017-87202-P

•
Funding agency name Agencia Estatal de Investigación
Funding agency acronym AEI
Program Programa Estatal de Fomento de la Investigación Científica y Técnica de Excelencia
Subprogram Subprograma Estatal de Generación de Conocimiento
Call Proyectos de I+D (Excelencia / Generación de Conocimiento)
Call year 2017
State Plan 2017-2020 Plan Estatal de Investigación Científica y Técnica y de Innovación
Beneficiary centre FUNDACIÓ INSTITUT CATALÀ DE NANOCIÈNCIA I NANOTECNOLOGIA

Resultados relacionados

Resultados totales (Incluyendo duplicados): 55
Encontrada(s) 1 página(s)

DIGITAL.CSIC. Repositorio Institucional del CSIC
Publication Artículo científico (JournalArticle)

Optical-based (bio) sensing systems using magnetic nanoparticles

  • Üzek, Recep
  • Sari, Esma
  • Merkoçi, Arben
This article belongs to the Special Issue Magnetic Nanoparticles., In recent years, various reports related to sensing application research have suggested that combining the synergistic impacts of optical, electrical or magnetic properties in a single technique can lead to a new multitasking platform. Owing to their unique features of the magnetic moment, biocompatibility, ease of surface modification, chemical stability, high surface area, high mass transference, magnetic nanoparticles have found a wide range of applications in various fields, especially in sensing systems. The present review is comprehensive information about magnetic nanoparticles utilized in the optical sensing platform, broadly categorized into four types: surface plasmon resonance (SPR), surface-enhanced Raman spectroscopy (SERS), fluorescence spectroscopy and near-infrared spectroscopy and imaging (NIRS) that are commonly used in various (bio) analytical applications. The review also includes some conclusions on the state of the art in this field and future aspects., The ICN2 is funded by the CERCA Programme / Generalitat de Catalunya. The ICN2 is supported by the Severo Ochoa program of the Spanish Ministry of Economy, Industry and Competitiveness (MINECO, grant No. SEV-2017-0706). Financial support was obtained under MINECO project MAT2017-87202-P., Peer reviewed
DIGITAL.CSIC. Repositorio Institucional del CSIC
Publication Artículo científico (JournalArticle)

Design and fabrication of printed paper‐based hybrid micro‐supercapacitor by using graphene and redox‐active electrolyte

  • Nagar, Bhawna
  • Dubal, Deepak P.
  • Pires, Luis
  • Merkoçi, Arben
  • Gómez-Romero, P.
Inspired by future needs of flexible, simple, and low-cost energy storage devices, smart graphene-based micro-supercapacitors on conventional Xerox paper substrates were developed. The use of redox-active species (iodine redox couple) was explored to further improve the paper device's performance. The device based on printed graphene paper itself already had a remarkable maximum volumetric capacitance of 29.6 mF cm-3 (volume of whole device) at 6.5 mA cm-3 . The performance of the hybrid electrode with redox-active potassium iodide at the graphene surface was tested. Remarkably, the hybrid device showed improved volumetric capacitance of 130 mF cm-3 . The maximum energy density for a graphene+KI device in H2 SO4 electrolyte was estimated to be 0.026 mWh cm-3 . Thus, this work offers a new simple, and lightweight micro-supercapacitor based on low-cost printed graphene paper, which will have great applications in portable electronics., Partial funding from MINECO (grants no. MAT2015-68394-R, and MAT2017-87202-P MINECO/FEDER) and recognition from AGAUR (2017 SGR 870) are acknowledged. The ICN2 is supported by the Severo Ochoa program of the Spanish Ministry of Economy, Industry, and Competitiveness (MINECO, grant no. SEV-2013-0295) and funded by the CERCA program/ Generalitat de Catalunya., Peer reviewed
DIGITAL.CSIC. Repositorio Institucional del CSIC
Publication Artículo científico (JournalArticle)

Microorganism-decorated nanocellulose for efficient diuron removal

  • Liu, Jie
  • Morales-Narváez, Eden
  • Vicent, Teresa
  • Merkoçi, Arben
  • Zhong, Guohua
The environmental impacts of diuron have generated growing interest in remediation methods to prevent the potential threat of diuron to ecosystem integrity and human beings. Here, a simple and effective nanocellulose-based biocomposite coupled with Arthrobacter globiformis D47 as a herbicide degrader is presented for the rapid elimination of diuron. First, bacterium D47 was immobilized on the fiber networks of the nanocellulose, forming a bacteria-decorated nanocellulose (BDN) that outperformed direct utilization of bacterial suspensions for diuron decomposition. More importantly, the advantageous features of BDN could remarkably broaden its applicability since the bio-hybrid material rapidly degraded diuron and its major metabolite 3,4-dichloroaniline at low concentrations (1–10 mg L−1). In addition, the morphology of BDN revealed the excellent biocompatibility of nanocellulose as cell scaffolding for bacterial proliferation. Then, the adsorption capacity of the nanocellulose and the enzymatic metabolism of the bacteria were validated as a joint mechanism of the BDN biocomposites in the removal of diuron. In addition, the wide applicability of BDN was further verified by the degradation of diuron in environmental matrices and other phenylurea herbicide targets. Therefore, the novel microorganism-immobilized nanocellulose composites provide a promising alternative material combining functional microorganisms with emerging nanomaterials, which may facilitate the bioremediation of organic xenobiotic pollution in complex environments., This work was supported by the National Natural Science Foundation of China (No. 31371960) and the Guangdong Province Science and Technology Plan Project (No. 2015B020207003). ICN2 is funded by the CERCA Programme/Generalitat de Catalunya, and we acknowledge the support from the Severo Ochoa Program (MINECO, Grant SEV-2013-0295) and the Spanish MINECO under project MAT2017-87202-P. EMN acknowledges the financial support from CONACYT (Mexico, Grant 293523)., Peer reviewed
DIGITAL.CSIC. Repositorio Institucional del CSIC
Publication Artículo científico (JournalArticle)

Uranium (VI) detection in groundwater using a gold nanoparticle/paper-based lateral fow device

  • Quesada-González, Daniel
  • Jairo, Grace A.
  • Blake II, Robert C.
  • Blake, Diane A.
  • Merkoçi, Arben
The contamination in groundwater due to the presence of uranium is nowadays a subject of concern due to the severe health problems associated with renal failure, genotoxicity and cancer. The standard methods to detect uranium require time-consuming processes and expensive non-portable equipment, so these measurements are rarely performed in-field, which increases the time until water samples are analysed. Furthermore, the few portable methods available do not allow quantitative analysis and the detection limit is often not low enough to reach the recommendations for drinking water (30 ppb or 126 nM of uranium). For the first time, we propose a portable, fast, inexpensive and sensitive paper-based biosensor able to detect in situ U(VI) in water samples: U(VI) selective gold nanoparticle-based lateral flow strips. Antibody-coated gold nanoparticles are used as labels in the proposed lateral flow system because of their biocompatibility; in addition, these nanoparticles provide high sensitivity due to their intense plasmonic effect. The antibody used in the assay recognizes soluble U(VI) complexed to the chelator, 2,9-dicarboxyl-1,10-phenanthroline (DCP). Because of the small size of the U(VI)-DCP complex, this assay employs a competitive format that reaches a limit of detection of 36.38 nM, lower than the action level (126 nM) established by the World Health Organization and the U.S. Environmental Protection Agency for drinking waters., We acknowledge Ministerio de Economía, Industria y Competitividad (MINECO), Agencia Estatal de Investigación (AEI) and Fondo Europeo de Desarrollo Regional (FEDER) for the project MAT2017-87202-P. Te ICN2 is funded by the CERCA Programme/Generalitat de Catalunya. Te ICN2 is supported by the Severo Ochoa program of the Spanish Ministry of Economy, Industry and Competitiveness (MINECO, grant No. SEV2013-0295). Additional support was provided by a grant from the US National Science Foundation to D.A. Blake (OISE‐1253272)., Peer reviewed
DIGITAL.CSIC. Repositorio Institucional del CSIC
Publication Artículo científico (JournalArticle)

A nitrocellulose paper strip for fluorometric determination of bisphenol A using molecularly imprinted nanoparticles

  • Üzek, Recep
  • Sari, Esma
  • Şenel, Serap
  • Denizli, Adil
  • Merkoçi, Arben
The authors describe a test stripe for fluorometric determination of the endocrine disruptor bisphenol A (BPA). Graphene quantum dots (GQDs) were immobilized on molecularly imprinted nanoparticles which then were placed on nitrocellulose paper. The GQDs display blue fluorescence (with excitation/emission peaks at 350/440 nm) which is reduced in the presence of BPA. The test stripe has a 43.9 ± 0.8 μg·L−1 limit of detection in case of water samples. The stripe was applied to the determination of BPA in (spiked) tap water and sea water, and the LODs were found to be 1.8 ± 0.2 μg·L−1 and 4.2 ± 0.5 μg·L−1, respectively. Structural analogs of BPA, such as aminophenol, phenol, hydroquinone and naphthol were found not to interfere., Recep Üzek thanks to TUBITAK for the given scholarship. We acknowledge support from MINECO, Spain for MAT2017-87202-P and Graphene Flagship Core Project 2 (Ref: 785219). ICN2 is supported by the Severo Ochoa program from Spanish MINECO (Grant No. SEV-2017-0706). This work is also funded by the CERCA Programme / Generalitat de Catalunya., Peer reviewed
DIGITAL.CSIC. Repositorio Institucional del CSIC
Publication Artículo científico (JournalArticle)

In situ plant virus nucleic acid isothermal amplification detection on gold nanoparticle-modified electrodes

  • Khater, Mohga
  • Escosura-Muñiz, Alfredo de la
  • Altet, Laura
  • Merkoçi, Arben
Solid-phase isothermal recombinase polymerase amplification (RPA) offers many benefits over the standard RPA in homogeneous phase in terms of sensitivity, portability, and versatility. However, RPA devices reported to date are limited by the need for heating sources to reach sensitive detection. With the aim of overcoming such limitation, we propose here a label-free highly integrated in situ RPA amplification/detection approach at room temperature that takes advantage of the high sensitivity offered by gold nanoparticle (AuNP)-modified sensing substrates and electrochemical impedance spectroscopic (EIS) detection. Plant disease (Citrus tristeza virus (CTV)) diagnostics was selected as a relevant target for demonstration of the proof-of-concept. RPA assay for amplification of the P20 gene (387-bp) characteristic of CTV was first designed/optimized and tested by standard gel electrophoresis analysis. The optimized RPA conditions were then transferred to the AuNP-modified electrode surface, previously modified with a thiolated forward primer. The in situ-amplified CTV target was investigated by EIS in a Fe(CN6)4–/Fe(CN6)3– red–ox system, being able to quantitatively detect 1000 fg μL–1 of nucleic acid. High selectivity against nonspecific gene sequences characteristic of potential interfering species such as Citrus psorosis virus (CPsV) and Citrus caxicia viroid (CCaV) was demonstrated. Good reproducibility (RSD of 8%) and long-term stability (up to 3 weeks) of the system were also obtained. Overall, with regard to sensitivity, cost, and portability, our approach exhibits better performance than RPA in homogeneous phase, also without the need of heating sources required in other solid-phase approaches., The ICN2 is funded by the CERCA programme/Generalitat de Catalunya. ICN2 acknowledges the support of the Spanish MINECO for the Project MAT2017-87202-P and the Severo Ochoa Centers of Excellence Program under Grant SEV2201320295. M.K. thanks Autonomous University of Barcelona for the opportunity of performing this work inside the framework of Biotechnology PhD Programme., Peer reviewed
DIGITAL.CSIC. Repositorio Institucional del CSIC
Publication Artículo científico (JournalArticle)

Iridium oxide (IV) nanoparticle-based lateral flow immunoassay

  • Quesada-González, Daniel
  • Sena-Torralba, Amadeo
  • Prio Wicaksono, Wiyogo
  • Escosura-Muñiz, Alfredo de la
  • Ivandini, Tribidasari A.
  • Merkoçi, Arben
Lateral flow biosensors are paper-based devices that allow the detection of different types of analytes with quickness, robustness and selectivity, without leaving behind paper sensors benefits as low-cost, recyclability and sustainability. Nanomaterials have been widely reported in lateral flow biosensors, offering new sensing strategies based on optical or electrical detection techniques. Looking for other advantageous nanomaterials, we propose for the first time the use of iridium oxide (IV) nanoparticles in lateral flow assays for the detection of human immunoglobulin as a model protein. These nanoparticles can be easily prepared and conjugated with biomarkers. Their dark blue color gives a high contrast against the white background of the strips being in this way excellent labels., We acknowledge support from MINECO (Spain) MAT2017-87202-P and project PCIN-2016-066 (program Euronanomed 2). This work is also funded by the CERCA Programme / Generalitat de Catalunya. ICN2 is supported by the Severo Ochoa program from Spanish MINECO (Grant No. SEV-2017-0706). Daniel Quesada-González and Amadeo Sena-Torralba acknowledge Autonomous University of Barcelona (UAB) for the possibility of performing this work inside the framework of Chemistry and Biotechnology Ph.D. Programmes, respectively., Peer reviewed
DIGITAL.CSIC. Repositorio Institucional del CSIC
Publication Artículo científico (JournalArticle)

Nanomaterial‐based sensors for the study of DNA interaction with drugs

  • Cruz Morales, K. de la
  • Alarcon-Angeles, Georgina
  • Merkoçi, Arben
The interaction of drugs with DNA has been searched thoroughly giving rise to an endless number of findings of undoubted importance, such as a prompt alert to harmful substances, ability to explain most of the biological mechanisms, or provision of important clues in targeted development of novel chemotherapeutics. The existence of some drugs that induce oxidative damage is an increasing point of concern as they can cause cellular death, aging, and are closely related to the development of many diseases. Because of a direct correlation between the response, strength/ nature of the interaction and the pharmaceutical action of DNA‐targeted drugs, the electrochemical analysis is based on the signals of DNA before and after the interaction with the DNA‐targeted drug. Nowadays, nanoscale materials are used extensively for offering fascinating characteristics that can be used in designing new strategies for drug‐DNA interaction detection. This work presents a review of nanomaterials (NMs) for the study of drug‐nucleic acid interaction. We summarize types of drug‐DNA interactions, electroanalytical techniques for evidencing these interactions and quantification of drug and/or DNA monitoring., The ICN2 is funded by the CERCA programme/Generalitat de Catalunya. ICN2 acknowledges the support of the Spanish MINECO for the Project MAT2017‐87202‐P and through the Severo Ochoa Centers of Excellence Program under Grant SEV2201320295. KDCM thank the CONACyT for the support through the scholarship #817447., Peer reviewed
DIGITAL.CSIC. Repositorio Institucional del CSIC
Publication Artículo científico (JournalArticle)

Production and printing of graphene oxide foam ink for electrocatalytic applications

  • Baptista-Pires, Luis
  • Escosura-Muñiz, Alfredo de la
  • Balsells, Marc
  • Zuaznabar-Gardona, Julio C.
  • Merkoçi, Arben
A graphene-based ink printed as a foam-like structure with open pores is reported. The production of the ink is easier and faster than using existing methods and the obtained product is stable in water suspension. Electrocatalytic applications of 3D structured electrodes printed onto plastic substrates were explored., We acknowledge support from MINECO, Spain, for MAT2017-87202-P, the Severo Ochoa program (Grant No. SEV-2013-0295) and Graphene Flagship Core Project 2 (Ref: 785219). This work is also funded by the CERCA Programme/Generalitat de Catalunya., Peer reviewed
DIGITAL.CSIC. Repositorio Institucional del CSIC
Publication Artículo científico (JournalArticle)

Paper based photoluminescent sensing platform with recognition sites for tributyltin

  • Sari, Esma
  • Üzek, Recep
  • Merkoçi, Arben
In this study, a novel photoluminescence material for the detection of tributyltin (TBT) was developed by using a paper-based nanocomposite system. For this purpose, molecularly imprinted polymeric nanoparticles (MIN) were synthesized with mini-emulsion polymerization technique. Graphene quantum dots obtained by the hydrothermal pyrolysis were immobilized to the nanoparticle surface via EDC-NHS coupling. The fabrication of sensing platform for TBT can be divided into two steps that are the preparation of nanocomposite and the applying the nanocomposite onto nitrocellulose membrane. The selectivity constant and association kinetics were calculated to analyze the interaction of TBT with immobilized MINs. The results proved that the developed nanosensor is promising for the determination of TBT with high selectivity and sensitivity reaching a detection limit of 0.23 ppt in seawater. This novel photoluminescent nanosensor has the potential to pave the way for further studies and applications., Recep Üzek thanks to TUBITAK for the given scholarship. We acknowledge the support from European Commission through the Graphene Flagship Core 2 project and from Ministerio de Economıa, Industria y Competitividad (MINECO), Agencia Estatal de Investigacion (AEI) for the project MAT2017-87202-P. The ICN2 is funded by the CERCA Programme/Generalitat de Catalunya. ICN2 is supported by the Severo Ochoa program from Spanish MINECO (Grant No. SEV2017-0706)., Peer reviewed
DIGITAL.CSIC. Repositorio Institucional del CSIC
Publication Artículo científico (JournalArticle)

Signal enhancement on gold nanoparticle-based lateral flow tests using cellulose nanofibers

  • Quesada-González, Daniel
  • Stefani, Christina
  • González, Israel
  • Escosura-Muñiz, Alfredo de la
  • Domingo, Neus
  • Mutjé, Pere
  • Merkoçi, Arben
Lateral flow paper-based biosensors merge as powerful tools in point-of-care diagnostics since they are cheap, portable, robust, selective, fast and easy to use. However, the sensitivity of this type of biosensors is not always as high as required, often not permitting a clear quantification. To improve the colorimetric response of standard lateral flow strips (LFs), we have applied a new enhancement strategy that increases the sensitivity of LFs based on the use of cellulose nanofibers (CNF). CNF penetrate inside the pores of LFs nitrocellulose paper, compacting the pore size only in the test line, particularly near the surface of the strip. This modification retains the bioreceptors (antibodies) close to the surface of the strips, and thus further increasing the density of selectively attached gold nanoparticles (AuNPs) in the top part of the membrane, in the test line area, only when the sample is positive. This effect boosts in average a 36.6% the sensitivity of the LFs. The optical measurements of the LFs were carried out with a mobile phone camera whose imaging resolution was improved by attaching microscopic lens on the camera objective. The characterization of CNF into paper and their effect was analyzed using atomic force microscope (AFM) and scanning electron microscope (SEM) imaging techniques., The ICN2 is funded by the CERCA Programme / Generalitat de Catalunya. The ICN2 is supported by the Severo Ochoa program of the Spanish Ministry of Economy, Industry and Competitiveness (MINECO, grant No. SEV-2017-0706). Financial support was obtained under MAT2017-87202-P, funded by Agencia Estatal de Investigación and Fondo Europeo de Desarrollo Regional, and MINECO project FIS2015-73932-JIN. This work was partially funded by 2017-SGR-579 project from the Generalitat de Catalunya. D.Q.G. acknowledges Universitat Autònoma de Barcelona for the possibility of carrying out this work inside the framework of its PhD Programme in Chemistry. Ch.S. thanks the BIST for a preBIST Grant (No. 754558)., Peer reviewed
DIGITAL.CSIC. Repositorio Institucional del CSIC
Publication Artículo científico (JournalArticle)

Nano-lantern on paper for smartphone-based ATP detection

  • Calabretta, Maria Maddalena
  • Álvarez-Diduk, Ruslan
  • Michelini, Elisa
  • Roda, Aldo
  • Merkoçi, Arben
ATP-driven bioluminescence relying on the D-luciferin-luciferase reaction is widely employed for several biosensing applications where bacterial ATP detection allows to verify microbial contamination for hygiene monitoring in hospitals, food processing and in general for cell viability studies. Several ATP kit assays are already commercially available but an user-friendly ATP biosensor characterized by low-cost, portability, and adequate sensitivity would be highly valuable for rapid and facile on site screening. Thanks to an innovative freeze-drying procedure, we developed a user-friendly, ready-to-use and stable ATP sensing paper biosensor that can be combined with smartphone detection. The ATP sensing paper includes a lyophilized “nano-lantern” with reaction components being rapidly reconstituted by 10 μL sample addition, enabling detection of 10−14 mol of ATP within 10 min. We analysed urinary microbial ATP as a biomarker of urinary tract infection (UTI), confirming the capability of the ATP sensing paper to detect the threshold for positivity corresponding to 105 colony-forming units of bacteria per mL of urin, This research was sponsored in part by PRIN 2015 “Multifunctional nanotools for advanced cancer diagnostics” (Prot. 2015TWP83Z) and the NATO Science for Peace and Security Programme under Grant No. 985042. The ICN2 is funded by the CERCA Programme/Generalitat de Catalunya and also supported by the Severo Ochoa program of the Spanish Ministry of Economy, Industry and Competitiveness (MINECO, grants No. SEV-2017-0706 and MAT2017-87202-P)., Peer reviewed
DIGITAL.CSIC. Repositorio Institucional del CSIC
Publication Artículo científico (JournalArticle)

Smart chip for visual detection of bacteria using the electrochromic properties of polyaniline

  • Ranjbar, Saba
  • Farahmand Nejad, Mohammad Amin
  • Parolo, Claudio
  • Shahrokhian, Saeed
  • Merkoçi, Arben
Finding fast and reliable ways to detect pathogenic bacteria is crucial for addressing serious public health issues in clinical, environmental, and food settings. Here, we present a novel assay based on the conversion of an electrochemical signal into a more convenient optical readout for the visual detection of Escherichia coli. Electropolymerizing polyaniline (PANI) on an indium tin oxide screen-printed electrode (ITO SPE), we achieved not only the desired electrochromic behavior but also a convenient way to modify the electrode surface with antibodies (taking advantage of the many amine groups of PANI). Applying a constant potential to the PANI-modified ITO SPE induces a change in their oxidation state, which in turn generates a color change on the electrode surface. The presence of E. coli on the electrode surface increases the resistance in the circuit affecting the PANI oxidation states, producing a different electrochromic response. Using this electrochromic sensor, we could measure concentrations of E. coli spanning 4 orders of magnitude with a limit of detection of 102 colony forming unit per 1 mL (CFU mL–1) by the naked eye and 101 CFU mL–1 using ImageJ software. In this work we show that merging the sensitivity of electrochemistry with the user-friendliness of an optical readout can generate a new and powerful class of biosensors, with potentially unlimited applications in a variety of fields., The ICN2 is funded by the CERCA Programme/Generalitat de Catalunya. The ICN2 is supported by the Severo Ochoa program of the Spanish Ministry of Economy, Industry and Competitiveness (MINECO, Grant SEV-2017-0706 and MAT2017-87202-P). C.P. acknowledges Marie Skłodowska-Curie Actions Individual Fellowship (Funding scheme, MSCA-IF-EF-RI; proposal number, 795635). The Iranian authors gratefully acknowledge the Research Council and the Center of Excellence for Nanostructures of the Sharif University of Technology, Tehran, Iran., Peer reviewed
DIGITAL.CSIC. Repositorio Institucional del CSIC
Publication Artículo científico (JournalArticle)

Lateral flow assay modified with time-delay wax barriers as a sensitivity and signal enhancement strategy

  • Sena-Torralba, Amadeo
  • Ngo, Duy Ba
  • Parolo, Claudio
  • Hu, Liming
  • Álvarez-Diduk, Ruslan
  • Bergua, José Francisco
  • Rosati, Giulio
  • Surareungchai, Werasak
  • Merkoçi, Arben
The ease of use, low cost and quick operation of lateral flow assays (LFA) have made them some of the most common point of care biosensors in a variety of fields. However, their generally low sensitivity has limited their use for more challenging applications, where the detection of low analytic concentrations is required. Here we propose the use of soluble wax barriers to selectively and temporarily accumulate the target and label nanoparticles on top of the test line (TL). This extended internal incubation step promotes the formation of the immune-complex, generating a 51.7-fold sensitivity enhancement, considering the limit of quantification, and up to 96% signal enhancement compared to the conventional LFA for Human IgG (H-IgG) detection., We acknowledge financial support from NACANCELL project PCIN-2016-066 (program Euronanomed 2). This work is also funded by the CERCA Program/Generalitat de Catalunya. The ICN2 is funded by the CERCA programme/Generalitat de Catalunya. ICN2 acknowledges the support of the Spanish MINECO for the Project MAT 2017-87202-P and through the Severo Ochoa Centres of Excellence Program under Grant SEV2201320295. Amadeo Sena-Torralba acknowledge Autonomous University of Barcelona (UAB) for the possibility of performing this work inside the framework of Biotechnology Ph.D. Programme. Duy Ba Ngo gratefully acknowledges Petchra Pra Jom Klao Doctoral, King Mongkut's University of Technology Thonburi (KMUTT) in Thailand and Sensor Technology, School of Bioresources and Technology, KMUTT, Thailand., Peer reviewed
DIGITAL.CSIC. Repositorio Institucional del CSIC
Publication Artículo científico (JournalArticle)

Recent advancement in biomedical applications on the surface of two-dimensional materials: from biosensing to tissue engineering

  • Nguyen, Emily P.
  • Castro Silva, Cecilia de Carvalho
  • Merkoçi, Arben
As biosensors and biomedical devices have become increasingly important to everyday diagnostics and monitoring, there are tremendous, and constant efforts towards developing and improving the reliability and versatility of such technology. As they offer high surface area-to-volume ratios and a diverse range of properties, from electronic to optical, two dimensional (2D) materials have proven to be very promising candidates for biological applications and technologies. Due to the dimensionality, 2D materials facilitate many interfacial phenomena that have shown to significantly improve the performance of biosensors, while recent advances in synthesis techniques and surface engineering methods also enable the realization of future biomedical devices. This short review aims to highlight the influence of 2D material surfaces and the properties that arise due to their 2D structure. Using recent (within the last few years) examples of biosensors and biomedical applications, we emphasize the important role of 2D materials in advancing developments and research for biosensing and healthcare., We acknowledge the financial support from the EU Graphene Flagship Core 3 Project (No. 881603), from the Spanish MINECO under project MAT2017-87202-P. ICN2 is supported by the Severo Ochoa program from Spanish MINECO (grant no. SEV-2013-0295) and by the CERCA Programme/Generalitat de Catalunya. E. P. N. acknowledges funding through the EU's Horizon 2020 research and innovation programme under the Marie Skłodowska-Curie grant agreement no. 754510. C. C. C. S acknowledges funding through CAPES – PRINT (Programa Institucional de Internacionalização; grant # 88887.310281/2018-00 and 88887.467442/2019-00)., Peer reviewed
DIGITAL.CSIC. Repositorio Institucional del CSIC
Publication Artículo científico (JournalArticle)

Chitin nanofiber paper toward optical (bio)sensing applications

  • Naghdi, Tina
  • Golmohammadi, H.
  • Yousefi, Hossein
  • Hosseinifard, Mohammad
  • Kostiv, Uliana
  • Horák, Daniel
  • Merkoçi, Arben
Because of numerous inherent and unrivaled features of nanofibers made of chitin, the second most plentiful natural-based polymer (after cellulose), including affordability, abundant nature, biodegradability, biocompatibility, commercial availability, flexibility, transparency, and extraordinary mechanical and physicochemical properties, chitin nanofibers (ChNFs) are being applied as one of the most appealing bionanomaterials in a myriad of fields. Herein, we exploited the beneficial properties offered by the ChNF paper to fabricate transparent, efficient, biocompatible, flexible, and miniaturized optical sensing bioplatforms via embedding/immobilizing various plasmonic nanoparticles (silver and gold nanoparticles), photoluminescent nanoparticles (CdTe quantum dots, carbon dots, and NaYF4:Yb3+@Er3+&SiO2 upconversion nanoparticles) along with colorimetric reagents (curcumin, dithizone, etc.) in the 3D nanonetwork scaffold of the ChNF paper. Several configurations, including 2D multi-wall and 2D cuvette patterns with hydrophobic barriers/walls and hydrophilic test zones/channels, were easily printed using laser printing technology or punched as spot patterns on the dried ChNF paper-based nanocomposites to fabricate the (bio)sensing platforms. A variety of (bio)chemicals as model analytes were used to confirm the efficiency and applicability of the fabricated ChNF paper-based sensing bioplatforms. The developed (bio)sensors were also coupled with smartphone technology to take the advantages of smartphone-based monitoring/sensing devices along with the Internet of Nano Things (IoNT)/the Internet of Medical Things (IoMT) concepts for easy-to-use sensing applications. Building upon the unrivaled and inherent features of ChNF as a very promising bionanomaterial, we foresee that the ChNF paper-based sensing bioplatforms will emerge new opportunities for the development of innovative strategies to fabricate cost-effective, simple, smart, transparent, biodegradable, miniaturized, flexible, portable, and easy-to-use (bio)sensing/monitoring devices., Financial support from the Chemistry & Chemical Engineering Research Centre of Iran (Tehran, Iran), Iran’s National Elites Foundation (INEF), Nano Novin Polymer Co. (Iran), and the Nano Match program of Iran Nanotechnology Initiative Council (INIC) are gratefully acknowledged. The ICN2 is funded by the CERCA Programme/Generalitat de Catalunya. The ICN2 is supported by the Severo Ochoa program of the Spanish Ministry of Economy, Industry and Competitiveness (MINECO; grant nos. SEV-2017-0706 and MAT2017-87202-P). The financial support of “the Czech Science Foundation (No. 19-00676S)” is also greatly appreciated., Peer reviewed
DIGITAL.CSIC. Repositorio Institucional del CSIC
Publication Artículo científico (JournalArticle)

Integrating gold nanoclusters, folic acid and reduced graphene oxide for nanosensing of glutathione based on “turn-off” fluorescence

  • Wong, Xin Yi
  • Quesada-González, Daniel
  • Manickam, Sivakumar
  • New, Siu Yee
  • Muthoosamy, Kasturi
  • Merkoçi, Arben
Glutathione (GSH) is a useful biomarker in the development, diagnosis and treatment of cancer. However, most of the reported GSH biosensors are expensive, time-consuming and often require complex sample treatment, which limit its biological applications. Herein, a nanobiosensor for the detection of GSH using folic acid-functionalized reduced graphene oxide-modified BSA gold nanoclusters (FA-rGO-BSA/AuNCs) based on the fluorescence quenching interactions is presented. Firstly, a facile and optimized protocol for the fabrication of BSA/AuNCs is developed. Functionalization of rGO with folic acid is performed using EDC/NHS cross-linking reagents, and their interaction after loading with BSA/AuNCs is demonstrated. The formation of FA-rGO, BSA/AuNCs and FA-rGO-BSA/AuNCs are confirmed by the state-of-art characterization techniques. Finally, a fluorescence turn-off sensing strategy is developed using the as-synthesized FA-rGO-BSA/AuNCs for the detection of GSH. The nanobiosensor revealed an excellent sensing performance for the detection of GSH with high sensitivity and desirable selectivity over other potential interfering species. The fluorescence quenching is linearly proportional to the concentration of GSH between 0 and 1.75 µM, with a limit of detection of 0.1 µM under the physiological pH conditions (pH 7.4). Such a sensitive nanobiosensor paves the way to fabricate a “turn-on” or “turn-off” fluorescent sensor for important biomarkers in cancer cells, presenting potential nanotheranostic applications in biological detection and clinical diagnosis., This work was supported by the Fundamental Research Grant Scheme (FRGS), Ministry of Higher Education (MOHE), Malaysia [FRGS/1/2016/STG07/UNIM/02/1] and by the CERCA Programme/Generalitat de Catalunya. ICN2 is supported by the Severo Ochoa Centres of Excellence programme, funded by the Spanish Research Agency (AEI, Grant no. SEV-2017-0706). We acknowledge support from Ministerio de Economía, Industria y Competitividad (MINECO), Agencia Estatal de Investigación (AEI) and Fondo Europeo de Desarrollo Regional (FEDER) for funding the project MAT2017-87202-P. Authors acknowledge the European Union’s Horizon 2020 research and innovation programme under Grant Agreement No. 881603 (Graphene Flagship Core 3)., Peer reviewed
DIGITAL.CSIC. Repositorio Institucional del CSIC
Publication Artículo científico (JournalArticle)

Wearable and fully printed microfluidic nanosensor for sweat rate, conductivity, and copper detection with healthcare applications

  • Yang, Qiuyue
  • Rosati, Giulio
  • Abarintos, Vernalyn
  • Aroca, Miguel Ángel
  • Osma, J.
  • Merkoçi, Arben
Título del postprint: Wearable and fully printed microfluidic nanosensor for sweat rate, conductivity, and copper detection for diseases prevention, Wearables are becoming pervasive in our society, but they are still mainly based on physical sensors with just few optical and electrochemical exceptions. Sweat, amongst other body fluids, is easily and non-invasively accessible, abundant, and relatively poor of interfering species. The biomarkers of interest in sweat space from ions and small molecules to whole organisms. Heavy metals have been found being biomarkers of several diseases and pathological conditions. Copper in particular is correlated to Wilson's disease and liver cirrhosis among others. Nevertheless, several issues such as sampling conditions, sweat rate normalization, reliable continuous monitoring, and typically expensive fabrication methods still needs to be addressed in sweat analysis with wearables. Herein, we propose a fully printed wearable microfluidic nanosensor with an integrated wireless smartphone-based readout. Our system can easily be applied on the skin and actively stimulate perspiration, normalizing the heavy metals concentration with respect to the volume of the sample and the sweat rate. The system has a limit of detection of 396 ppb, a linear range up to 2500 ppb and a sensitivity of 2.3 nA/ppb., Grant MAT 2017-87202-P funded by MCIN/AEI/10.13039/501100011033 and by “ERDF A way of making Europe”. ICN2 is funded by CERCA programme, Generalitat de Catalunya. Grant SEV-2017-0706 funded by MCIN/AEI/10.13039/501100011033., Peer reviewed
DIGITAL.CSIC. Repositorio Institucional del CSIC
Publication Artículo científico (JournalArticle)

A novel ratiometric fluorescent approach for the modulation of the dynamic range of lateral flow immunoassays

  • Sena-Torralba, Amadeo
  • Torné Morató, Helena
  • Parolo, Claudio
  • Ranjbar, Saba
  • Farahmand Nejad, Mohammad Amin
  • Álvarez-Diduk, Ruslan
  • Idili, Andrea
  • Hormozi-Nezhad, Mohammad Reza
  • Merkoçi, Arben
The majority of lateral flow assays (LFAs) use single-color optical labels to provide a qualitative naked-eye detection, however this detection method displays two important limitations. First, the use of a single-color label makes the LFA prone to results misinterpretation. Second, it does not allow the precise modulation of the sensitivity and dynamic range of the test. To overcome these limitations, a ratiometric approach is developed. In particular, using anti-HIgG functionalized red-fluorescent quantum dots on the conjugate pad (as target dependent labels) and blue-fluorescent nanoparticles fixed on the test line (as target independent reporters), it is possible to generate a wide color palette (blue, purple, pink, red) on the test line. It is believed that this strategy will facilitate the development of LFAs by easily adjusting their analytical properties to the needs required by the specific application., The authors acknowledge financial support from NACANCELL project PCIN-2016-066 (program Euronanomed 2). This work was also funded by the CERCA Program/Generalitat de Catalunya. The ICN2 was funded by the CERCA program/Generalitat de Catalunya. ICN2 acknowledges the support of the Spanish MINECO for the Project MAT2017-87202-P and through the Severo Ochoa Centres of Excellence Program under Grant SEV2201320295. A.I. was supported by PROBIST postdoctoral fellowship funded by European Research Council (Marie Sklodowska Curie) grant agreement No. 754510). C.P. acknowledges support from the Spanish Ministry of Science and Innovation and State Research Agency through the “Centro de Excelencia Severo Ochoa 2019-2023” Program (CEX2018-000806-S), and support from the Generalitat de Catalunya through the CERCA Program., Peer reviewed
DIGITAL.CSIC. Repositorio Institucional del CSIC
Publication Artículo científico (JournalArticle)

Graphene Nanobeacons with High-Affinity Pockets for Combined, Selective, and Effective Decontamination and Reagentless Detection of Heavy Metals

  • Panáček, David
  • Zdražil, Lukáš
  • Langer, Michal
  • Šedajová, Veronika
  • Baďura, Zdeněk
  • Zoppellaro, Giorgio
  • Yang, Qiuyue
  • Nguyen, Emily P.
  • Álvarez-Diduk, Ruslan
  • Hrubý, Vítězslav
  • Kolařík, Jan
  • Chalmpes, Nikolaos
  • Bourlinos, Athanasios B.
  • Zboril, Radek
  • Merkoçi, Arben
  • Bakandritsos, Aristides
  • Otyepka, Michal
Access to clean water for drinking, sanitation, and irrigation is a major sustainable development goal of the United Nations. Thus, technologies for cleaning water and quality-monitoring must become widely accessible and of low-cost, while being effective, selective, sustainable, and eco-friendly. To meet this challenge, hetero-bifunctional nanographene fluorescent beacons with high-affinity pockets for heavy metals are developed, offering top-rated and selective adsorption for cadmium and lead, reaching 870 and 450 mg g, respectively. The heterobifunctional and multidentate pockets also operate as selective gates for fluorescence signal regulation with sub-nanomolar sensitivity (0.1 and 0.2 nm for Pb and Cd, respectively), due to binding affinities as low as those of antigen-antibody interactions. Importantly, the acid-proof nanographenes can be fully regenerated and reused. Their broad visible-light absorption offers an additional mode for water-quality monitoring based on ultra-low cost and user-friendly reagentless paper detection with the naked-eye at a limit of detection of 1 and 10 ppb for Pb and Cd ions, respectively. This work shows that photoactive nanomaterials, densely-functionalized with strong, yet selective ligands for targeted contaminants, can successfully combine features such as excellent adsorption, reusability, and sensing capabilities, in a way to extend the material's applicability, its life-cycle, and value-for-money., The work was supported by the ERDF/ESF project “Nano4Future” (No. CZ.02.1.01/0.0/0.0/16_019/0000754). R.Z. and A.B. acknowledge the funding from the Czech Science Foundation, GA CR–EXPRO, 19-27454X. D.P., L.Z., V.Š., M.L., and V.H. thank the Internal Student Grant Agency of the Palacký University in Olomouc, Czech Republic (IGA_PrF_2022_019). M.O. acknowledges the ERC grant 2D-CHEM, No 683024 from H2020. Operation of XPS and TEM facilities was partly funded by the Research Infrastructure NanoEnviCz, supported by the Ministry of Education, Youth and Sports of the Czech Republic under Project No. LM2018124. N.C. gratefully acknowledges the IKY foundation for the financial support. N.C. and A.B.B. also thank the European Social Fund-ESF (co-financed by Greece and the European Union) through the Operational Programme “Human Resources Development, Education and Lifelong Learning” in the context of the project “Strengthening Human Resources Research Potential via Doctorate Research” (MIS-5000432), implemented by the State Scholarships Foundation (IKY). Computational resources were supplied by the project “e-Infrastruktura CZ” (e-INFRA CZ LM2018140) supported by the Ministry of Education, Youth, and Sports of the Czech Republic. This work was supported by the Ministry of Education, Youth, and Sports of the Czech Republic through the e-INFRA CZ (ID:90140). ICN2 is funded by CERCA programme, Generalit de Catalunya. Grant SEV-2017-0706 by MCIN/AEI/10.13039/501100011033. The authors also acknowledge the project MAT2017-87202-P funded by MCIN/AEI/10.13039/501100011033 and FEDER Una manera de hacer Europa. R.A.-D. acknowledges funding from the European Union Horizon 2020 Programme under Grant No. 881603 (Graphene Flagship Core 3).
DIGITAL.CSIC. Repositorio Institucional del CSIC
Publication Artículo científico (JournalArticle)

Low-Cost, User-Friendly, All-Integrated Smartphone-Based Microplate Reader for Optical-Based Biological and Chemical Analyses

  • Bergua, José Francisco
  • Álvarez-Diduk, Ruslan
  • Idili, Andrea
  • Parolo, Claudio
  • Maymó i Camós, Marc
  • Hu, Liming
  • Merkoçi, Arben
The quantitative detection of different molecular targets is of utmost importance for a variety of human activities, ranging from healthcare to environmental studies. Bioanalytical methods have been developed to solve this and to achieve the quantification of multiple targets from small volume samples. Generally, they can be divided into two different classes: point of care (PoC) and laboratory-based approaches. The former is rapid, low-cost, and user-friendly; however, the majority of the tests are semiquantitative, lacking in specificity and sensitivity. On the contrary, laboratory-based approaches provide high sensitivity and specificity, but the bulkiness of experimental instruments and complicated protocols hamper their use in resource-limited settings. In response, here we propose a smartphone-based device able to support laboratory-based optical techniques directly at the point of care. Specifically, we designed and fabricated a portable microplate reader that supports colorimetric, fluorescence, luminescence, and turbidity analyses. To demonstrate the potential of the device, we characterized its analytical performance by detecting a variety of relevant molecular targets (ranging from antibodies, toxins, drugs, and classic fluorophore dyes) and we showed how the estimated results are comparable to those obtained from a commercial microplate reader. Thanks to its low cost (<$300), portability (27 cm [length] × 18 cm [width] × 7 cm [height]), commercially available components, and open-source-based system, we believe it represents a valid approach to bring high-precision laboratory-based analysis at the point of care., ICN2 is funded by CERCA programme, Generalitat de Catalunya. Grant SEV-2017-0706 funded by MCIN/AEI/10.13039/501100011033. The authors acknowledge Consejo Superior de Investigaciones Científicas (CSIC) for the project “COVID19-122” granted in the call “Nuevas ayudas extraordinarias a proyectos de investigación en el marco de las medidas urgentes extraordinarias para hacer frente al impacto económico y social del COVID-19 (Ayudas CSIC-COVID-19)” and the research project INTCATCH 2020, Development and application of novel, integrated tools for monitoring and managing catchments supported by the European Union’s Horizon 2020 research and innovation program (Grant 689341). The authors also acknowledge the project MAT2017-87202-P funded by MCIN/AEI/10.13039/501100011033/and FEDER Una manera de hacer Europa. R.A.-D. acknowledges funding from the European Union Horizon2020 Programme under Grant No. 881603 (Graphene Flagship Core 3). A.I. was supported by PROBIST postdoctoral fellowship funded by the European Research Council (Marie Skłodowska-Curie grant agreement no. 754510).
DIGITAL.CSIC. Repositorio Institucional del CSIC
Publication Otros (Other)

Optical smartphone-based sensing: diagnostic of biomarkers

  • Hu, Liming
  • Idili, Andrea
  • Parolo, Claudio
  • Álvarez-Diduk, Ruslan
  • Calucho, Enric
  • Merkoçi, Arben
Biomarkers are nucleic acids, peptides, proteins, lipids metabolites, or other small molecules in human tissues or biological fluids whose accurate detection contributes to the prediction and determination of diseases and their status. In recent years, platforms that allow the detection of important biomarkers at the point-of-care (PoC) are moving the field of diagnostics towards personalized medicine. In order to comply with the REASSURED criteria stated by the WHO, the most efficient solution is to integrate PoC devices with smartphones. Without a doubt the smartphone camera is a “smart detector,” and almost all the optical-based methods have been integrated, including absorbance, fluorescence, microscopic bio-imaging, surface plasmon resonance, chemiluminescence, bioluminescence, and photoluminescence. In this chapter, we explain how smartphones can be used as smart detectors in diagnostic devices and we will provide an overview of recent developments of smartphone-based optical PoC devices., A.M. acknowledge FEDER/Ministerio de Ciencia, Innovación y Universidades - Agencia Estatal de Investigación/_Project MAT2017-87202-P. A.M. also acknowledge ICN2 which is funded by the CERCA programme/Generalitat de Catalunya and supported by the Severo Ochoa Centres of Excellence programme that is funded by the Spanish Research Agency (AEI, grant no. SEV-2017-0706). A.M, L.H., A.I., C.P., R.A. and E.C. acknowledge Autonomous University of Barcelona (UAB) for their support. E.C. acknowledges Ministerio de Ciencia e Innovación of Spain and Fondo Social Europeo for the Fellowship PRE2018–084856 under the framework of “Plan Estatal de Investigación Científica y Técnica y de Innovación 2017–2020. L. H. acknowledges China Scholarship Council which is a non-profit institute affiliated with the Ministry of Education of the P. R. China. A.I. was supported by PROBIST postdoctoral fellowship funded by European Research Council (Marie Skłodowska-Curie grant agreement No. 754510)., Peer reviewed
DIGITAL.CSIC. Repositorio Institucional del CSIC
Publication Artículo científico (JournalArticle)

Metal-free cysteamine-functionalized graphene alleviates mutual interferences in heavy metal electrochemical detection

  • Yang, Qiuyue
  • Nguyen, Emily P.
  • Panáček, David
  • Šedajová, Veronika
  • Hrubý, Vítězslav
  • Rosati, Giulio
  • Castro Silva, Cecilia de Carvalho
  • Bakandritsos, Aristides
  • Otyepka, Michal
  • Merkoçi, Arben
Heavy metal pollutants are of great concern to environmental monitoring due to their potent toxicity. Electrochemical detection, one of the main techniques, is hindered by the mutual interferences of various heavy metal ions in practical use. In particular, the sensitivity of carbon electrodes to Cd2+ ions (one of the most toxic heavy metals) is often overshadowed by some heavy metals (e.g. Pb2+ and Cu2+). To mitigate interference, metallic particles/films (e.g. Hg, Au, Bi, and Sn) typically need to be embedded in the carbon electrodes. However, these additional metallic materials may face issues of secondary pollution and unsustainability. In this study, a metal-free and sustainable nanomaterial, namely cysteamine covalently functionalized graphene (GSH), was found to lead to a 6-fold boost in the Cd2+ sensitivity of the screen-printed carbon electrode (SPCE), while the sensitivities to Pb2+ and Cu2+ were not influenced in simultaneous detection. The selective enhancement could be attributed to the grafted thiols on GSH sheets with good affinity to Cd2+ ions based on Pearson's hard and soft acid and base principle. More intriguingly, the GSH-modified SPCE (GSH-SPCE) featured high reusability with extended cycling times (23 times), surpassing the state-of-art SPCEs modified by non-covalently functionalized graphene derivatives. Last, the GSH-SPCE was validated in tap water., Grant MAT2017-87202-P funded by MCIN/AEI/ 10.13039/501100011033. ICN2 is funded by CERCA programme, Generalitat de Catalunya. Grant SEV-2017-0706 funded by MCIN/AEI/ 10.13039/501100011033. Q. Y. thanks the funding of the Chinese scholarship council. D. P., V. Š. and V. H. thank the Internal Student Grant Agency of the Palacký University (IGA_PrF_2022_019). C.C.C.S. acknowledges funding through CAPES – PRINT (Programa Institucional de Internacionalização; grant #88887.310281/2018-00 and 88887.467442/2019-00) and Mackpesquisa-UPM. A. B. and M. O. acknowledge support by the project Nano4Future (no. CZ.02.1.01/0.0/0.0/16_019/0000754) financed from the ERDF and ESF. M. O. acknowledges the ERC grant 2D-CHEM, No 683024 from H2020., Peer reviewed
Dipòsit Digital de Documents de la UAB
Publication Artículo científico (JournalArticle)

Production and printing of graphene oxide foam ink for electrocatalytic applications

  • Baptista Pires, Luis Miguel|||0000-0002-2290-6386
  • De La Escosura-Muñiz, Alfredo|||0000-0002-9600-0253
  • Balsells, Marc|||0000-0001-6475-1514
  • Zuaznabar Gardona, Julio César
  • Merkoçi, Arben|||0000-0003-2486-8085
A graphene-based ink printed as a foam-like structure with open pores is reported. The production of the ink is easier and faster than using existing methods and the obtained product is stable in water suspension. Electrocatalytic applications of 3D structured electrodes printed onto plastic substrates were explored.
Dipòsit Digital de Documents de la UAB
Publication Artículo científico (JournalArticle)

Microorganism-decorated nanocellulose for efficient diuron removal

  • Liu, Jie
  • Morales-Narváez, Eden|||0000-0002-1536-825X
  • Vicent i Huguet, Teresa|||0000-0002-6547-7358
  • Merkoçi, Arben|||0000-0003-2486-8085
  • Zhong, Guohua
The environmental impacts of diuron have generated growing interest in remediation methods to prevent the potential threat of diuron to ecosystem integrity and human beings. Here, a simple and effective nanocellulose-based biocomposite coupled with Arthrobacter globiformis D47 as a herbicide degrader is presented for the rapid elimination of diuron. First, bacterium D47 was immobilized on the fiber networks of the nanocellulose, forming a bacteria-decorated nanocellulose (BDN) that outperformed direct utilization of bacterial suspensions for diuron decomposition. More importantly, the advantageous features of BDN could remarkably broaden its applicability since the bio-hybrid material rapidly degraded diuron and its major metabolite 3,4-dichloroaniline at low concentrations (1-10 mg ⁻¹). In addition, the morphology of BDN revealed the excellent biocompatibility of nanocellulose as cell scaffolding for bacterial proliferation. Then, the adsorption capacity of the nanocellulose and the enzymatic metabolism of the bacteria were validated as a joint mechanism of the BDN biocomposites in the removal of diuron. In addition, the wide applicability of BDN was further verified by the degradation of diuron in environmental matrices and other phenylurea herbicide targets. Therefore, the novel microorganism-immobilized nanocellulose composites provide a promising alternative material combining functional microorganisms with emerging nanomaterials, which may facilitate the bioremediation of organic xenobiotic pollution in complex environments.
Dipòsit Digital de Documents de la UAB
Publication Artículo científico (JournalArticle)

Iridium oxide (IV) nanoparticle-based electrocatalytic detection of PBDE

  • Quesada-González, Daniel|||0000-0003-3064-2146
  • Baiocco, Alessandra
  • Martos, Andrea A.
  • De La Escosura-Muñiz, Alfredo|||0000-0002-9600-0253
  • Palleschi, Giuseppe
  • Merkoçi, Arben|||0000-0003-2486-8085
Polybrominated diphenyl ethers (PBDEs) are a type of flame retardants which are currently banned in EU and USA due their hazardousness for humans and mammals. However, these compounds were highly used during more than 30 years and still persist in the environment since they are resistant to degradation. Herein we present a biosensor for the detection of PBDEs using screen printed carbon electrodes (SPCEs) based on the electrochemical monitoring of water oxidation reaction (WOR) catalyzed by iridium oxide (IV) nanoparticles (IrO NPs). Our assay shows a limit of detection of 21.5 ppb of PBDE in distilled water. We believe that such an IrO NPs-based electrocatalytic sensing system can lead to a rapid, sensitive, low cost and miniaturizable device for the detection of PBDEs.
Dipòsit Digital de Documents de la UAB
Publication Artículo científico (JournalArticle)

Fully printed one-step biosensing device using graphene/AuNPs composite

  • Nagar, Bhawna|||0000-0003-2363-9758
  • Balsells, Marc|||0000-0001-6475-1514
  • De La Escosura-Muñiz, Alfredo|||0000-0002-9600-0253
  • Gómez-Romero, Pedro|||0000-0002-6208-5340
  • Merkoçi, Arben|||0000-0003-2486-8085
Driven by the growing need of simple, cost efficient and flexible sensing systems, we have designed here a fully printed Reduced Graphene Oxide (rGO) based impedimetric sensor for one step sensing of DNA. The DNA sensor was fabricated by stamping of layered rGO and rGO/gold nanoparticles/single stranded DNA (rGO/AuNPs/ssDNA) composites over PET substrates using wax-printing technique. rGO works as an excellent working electrode, while the AuNPs create a suitable environment for ssDNA immobilization. Counter and reference electrodes were previously screen-printed on the plastic substrate, making thus a compact and highly integrated sensing platform. The change in electron transfer resistance after hybridization with a target ssDNA specific of Coxsackie B3 virus was monitored using electrochemical impedance spectroscopy (EIS), finding a linear response in the range of concentrations 0.01-20 µM. The novel, simple and straightforward one-step printing process for fabrication of a biosensing device developed keeps in mind the growing need of large scale device manufacturing. The successful proof-of-concept for the detection of DNA hybridization can be extended to other affinity biosensors, taking advantage of the integration of the bioreceptor on the sensor surface. Such ready-to-use biosensor would lead to a one-step electrochemical detection.
Dipòsit Digital de Documents de la UAB
Publication Artículo científico (JournalArticle)

In Situ Plant Virus Nucleic Acid Isothermal Amplification Detection on Gold Nanoparticle-Modified Electrodes

  • Khater, Mohga
  • De La Escosura-Muñiz, Alfredo|||0000-0002-9600-0253
  • Altet Sanahujes, Laura
  • Merkoçi, Arben|||0000-0003-2486-8085
Solid-phase isothermal recombinase polymerase amplification (RPA) offers many benefits over the standard RPA in homogeneous phase in terms of sensitivity, portability, and versatility. However, RPA devices reported to date are limited by the need for heating sources to reach sensitive detection. With the aim of overcoming such limitation, we propose here a label-free highly integrated in situ RPA amplification/detection approach at room temperature that takes advantage of the high sensitivity offered by gold nanoparticle (AuNP)-modified sensing substrates and electrochemical impedance spectroscopic (EIS) detection. Plant disease (Citrus tristeza virus (CTV)) diagnostics was selected as a relevant target for demonstration of the proof-of-concept. RPA assay for amplification of the P20 gene (387-bp) characteristic of CTV was first designed/optimized and tested by standard gel electrophoresis analysis. The optimized RPA conditions were then transferred to the AuNP-modified electrode surface, previously modified with a thiolated forward primer. The in situ-amplified CTV target was investigated by EIS in a Fe(CN ) /Fe(CN ) red-ox system, being able to quantitatively detect 1000 fg μL of nucleic acid. High selectivity against nonspecific gene sequences characteristic of potential interfering species such as Citrus psorosis virus (CPsV) and Citrus caxicia viroid (CCaV) was demonstrated. Good reproducibility (RSD of 8%) and long-term stability (up to 3 weeks) of the system were also obtained. Overall, with regard to sensitivity, cost, and portability, our approach exhibits better performance than RPA in homogeneous phase, also without the need of heating sources required in other solid-phase approaches.
Dipòsit Digital de Documents de la UAB
Publication Artículo científico (JournalArticle)

Signal enhancement on gold nanoparticle-based lateral flow tests using cellulose nanofibers

  • Quesada-González, Daniel|||0000-0003-3064-2146
  • Stefani, Christina|||0000-0002-8818-075X
  • González Tovar, Israel|||0000-0002-3031-4516
  • De La Escosura-Muñiz, Alfredo|||0000-0002-9600-0253
  • Domingo Marimon, Neus|||0000-0002-5229-6638
  • Mutjé, Pere|||0000-0001-8211-4949
  • Merkoçi, Arben|||0000-0003-2486-8085
Lateral flow paper-based biosensors merge as powerful tools in point-of-care diagnostics since they are cheap, portable, robust, selective, fast and easy to use. However, the sensitivity of this type of biosensors is not always as high as required, often not permitting a clear quantification. To improve the colorimetric response of standard lateral flow strips (LFs), we have applied a new enhancement strategy that increases the sensitivity of LFs based on the use of cellulose nanofibers (CNF). CNF penetrate inside the pores of LFs nitrocellulose paper, compacting the pore size only in the test line, particularly near the surface of the strip. This modification retains the bioreceptors (antibodies) close to the surface of the strips, and thus further increasing the density of selectively attached gold nanoparticles (AuNPs) in the top part of the membrane, in the test line area, only when the sample is positive. This effect boosts in average a 36.6% the sensitivity of the LFs. The optical measurements of the LFs were carried out with a mobile phone camera whose imaging resolution was improved by attaching microscopic lens on the camera objective. The characterization of CNF into paper and their effect was analyzed using atomic force microscope (AFM) and scanning electron microscope (SEM) imaging techniques.
Dipòsit Digital de Documents de la UAB
Publication Artículo científico (JournalArticle)

Iridium oxide (IV) nanoparticle-based lateral flow immunoassay

  • Quesada-González, Daniel|||0000-0003-3064-2146
  • Sena-Torralba, Amadeo|||0000-0003-1340-1383
  • Wicaksono, Wiyogo Prio
  • De La Escosura-Muñiz, Alfredo|||0000-0002-9600-0253
  • Ivandini, Tribidasari A.
  • Merkoçi, Arben|||0000-0003-2486-8085
Lateral flow biosensors are paper-based devices that allow the detection of different types of analytes with quickness, robustness and selectivity, without leaving behind paper sensors benefits as low-cost, recyclability and sustainability. Nanomaterials have been widely reported in lateral flow biosensors, offering new sensing strategies based on optical or electrical detection techniques. Looking for other advantageous nanomaterials, we propose for the first time the use of iridium oxide (IV) nanoparticles in lateral flow assays for the detection of human immunoglobulin as a model protein. These nanoparticles can be easily prepared and conjugated with biomarkers. Their dark blue color gives a high contrast against the white background of the strips being in this way excellent labels.
Dipòsit Digital de Documents de la UAB
Publication Artículo científico (JournalArticle)

Nanomaterial-based Sensors for the Study of DNA Interaction with Drugs

  • De la Cruz Morales, K.
  • Alarcón Angeles, Georgina|||0000-0003-3275-423X
  • Merkoçi, Arben|||0000-0003-2486-8085
The interaction of drugs with DNA has been searched thoroughly giving rise to an endless number of findings of undoubted importance, such as a prompt alert to harmful substances, ability to explain most of the biological mechanisms, or provision of important clues in targeted development of novel chemotherapeutics. The existence of some drugs that induce oxidative damage is an increasing point of concern as they can cause cellular death, aging, and are closely related to the development of many diseases. Because of a direct correlation between the response, strength/ nature of the interaction and the pharmaceutical action of DNA-targeted drugs, the electrochemical analysis is based on the signals of DNA before and after the interaction with the DNA-targeted drug. Nowadays, nanoscale materials are used extensively for offering fascinating characteristics that can be used in designing new strategies for drug-DNA interaction detection. This work presents a review of nanomaterials (NMs) for the study of drug-nucleic acid interaction. We summarize types of drug-DNA interactions, electroanalytical techniques for evidencing these interactions and quantification of drug and/or DNA monitoring.
Dipòsit Digital de Documents de la UAB
Publication Artículo científico (JournalArticle)

Design and Fabrication of Printed Paper-Based Hybrid Micro-Supercapacitor by using Graphene and Redox-Active Electrolyte

  • Nagar, Bhawna|||0000-0003-2363-9758
  • Dubal, Deepak P.|||0000-0002-2337-676X
  • Baptista Pires, Luis Miguel|||0000-0002-2290-6386
  • Merkoçi, Arben|||0000-0003-2486-8085
  • Gómez-Romero, Pedro|||0000-0002-6208-5340
Inspired by future needs of flexible, simple, and low-cost energy storage devices, smart graphene-based micro-supercapacitors on conventional Xerox paper substrates were developed. The use of redox-active species (iodine redox couple) was explored to further improve the paper device's performance. The device based on printed graphene paper itself already had a remarkable maximum volumetric capacitance of 29.6 mF cm (volume of whole device) at 6.5 mA cm. The performance of the hybrid electrode with redox-active potassium iodide at the graphene surface was tested. Remarkably, the hybrid device showed improved volumetric capacitance of 130 mF cm. The maximum energy density for a graphene+KI device in HSO electrolyte was estimated to be 0.026 mWh cm. Thus, this work offers a new simple, and lightweight micro-supercapacitor based on low-cost printed graphene paper, which will have great applications in portable electronics.
Dipòsit Digital de Documents de la UAB
Publication Artículo científico (JournalArticle)

Uranium (VI) detection in groundwater using a gold nanoparticle/paper-based lateral flow device

  • Quesada-González, Daniel|||0000-0003-3064-2146
  • Jairo, Grace A.
  • Blake, Robert C.
  • Blake, Diane A.
  • Merkoçi, Arben|||0000-0003-2486-8085
The contamination in groundwater due to the presence of uranium is nowadays a subject of concern due to the severe health problems associated with renal failure, genotoxicity and cancer. The standard methods to detect uranium require time-consuming processes and expensive non-portable equipment, so these measurements are rarely performed in-field, which increases the time until water samples are analysed. Furthermore, the few portable methods available do not allow quantitative analysis and the detection limit is often not low enough to reach the recommendations for drinking water (30 ppb or 126 nM of uranium). For the first time, we propose a portable, fast, inexpensive and sensitive paper-based biosensor able to detect in situ U(VI) in water samples: U(VI) selective gold nanoparticle-based lateral flow strips. Antibody-coated gold nanoparticles are used as labels in the proposed lateral flow system because of their biocompatibility; in addition, these nanoparticles provide high sensitivity due to their intense plasmonic effect. The antibody used in the assay recognizes soluble U(VI) complexed to the chelator, 2,9-dicarboxyl-1,10-phenanthroline (DCP). Because of the small size of the U(VI)-DCP complex, this assay employs a competitive format that reaches a limit of detection of 36.38 nM, lower than the action level (126 nM) established by the World Health Organization and the U.S. Environmental Protection Agency for drinking waters.
Dipòsit Digital de Documents de la UAB
Publication Artículo científico (JournalArticle)

Chitin nanofiber paper toward optical (bio)sensing applications

  • Naghdi, Tina|||0000-0003-2932-2698
  • Golmohammadi, Hamed|||0000-0001-5271-2438
  • Yousefi, Hossein
  • Hosseinifard, Mohammad
  • Kostiv, Uliana
  • Horák, Daniel|||0000-0002-6907-9701
  • Merkoçi, Arben|||0000-0003-2486-8085
Because of numerous inherent and unrivaled features of nanofibers made of chitin, the second most plentiful natural-based polymer (after cellulose), including affordability, abundant nature, biodegradability, biocompatibility, commercial availability, flexibility, transparency, and extraordinary mechanical and physicochemical properties, chitin nanofibers (ChNFs) are being applied as one of the most appealing bionanomaterials in a myriad of fields. Herein, we exploited the beneficial properties offered by the ChNF paper to fabricate transparent, efficient, biocompatible, flexible, and miniaturized optical sensing bioplatforms via embedding/immobilizing various plasmonic nanoparticles (silver and gold nanoparticles), photoluminescent nanoparticles (CdTe quantum dots, carbon dots, and NaYF:Yb@Er&SiO upconversion nanoparticles) along with colorimetric reagents (curcumin, dithizone, etc.) in the 3D nanonetwork scaffold of the ChNF paper. Several configurations, including 2D multi-wall and 2D cuvette patterns with hydrophobic barriers/walls and hydrophilic test zones/channels, were easily printed using laser printing technology or punched as spot patterns on the dried ChNF paper-based nanocomposites to fabricate the (bio)sensing platforms. A variety of (bio)chemicals as model analytes were used to confirm the efficiency and applicability of the fabricated ChNF paper-based sensing bioplatforms. The developed (bio)sensors were also coupled with smartphone technology to take the advantages of smartphone-based monitoring/sensing devices along with the Internet of Nano Things (IoNT)/the Internet of Medical Things (IoMT) concepts for easy-to-use sensing applications. Building upon the unrivaled and inherent features of ChNF as a very promising bionanomaterial, we foresee that the ChNF paper-based sensing bioplatforms will emerge new opportunities for the development of innovative strategies to fabricate cost-effective, simple, smart, transparent, biodegradable, miniaturized, flexible, portable, and easy-to-use (bio)sensing/monitoring devices.
Dipòsit Digital de Documents de la UAB
Publication Artículo científico (JournalArticle)

Lab in a tube, point-of-care detection of Escherichia coli

  • Amin, Niloufar|||0000-0001-9743-0418
  • Sena-Torralba, Amadeo|||0000-0003-1340-1383
  • Álvarez Diduk, Ruslan|||0000-0002-9876-1574
  • Afkhami, Abbas|||0000-0002-3559-2080
  • Merkoçi, Arben|||0000-0003-2486-8085
Significant levels of infectious diseases caused by pathogenic bacteria are nowadays a worldwide matter, carrying considerable public health care challenges and huge economic concerns. Because of the rapid transmission of these biothreat agents and the outbreak of diseases, a rapid detection of pathogens in early stages is crucial, particularly in low-resources settings. To this aim, we developed for the first time a new sensing approach carried out in a single step for Escherichia coli O157:H7 detection. The detection principle is based on Förster resonance energy transfer using gold nanoclusters as a signal reporter and gold nanoparticles conjugated with antibodies as a quencher. The sensing platform includes an ultraviolet-light-emitting diode to provide the proper excitation and consists of a microtube containing two pieces of fiber glass; one of them is embedded with label-free gold nanoclusters and the other one with gold nanoparticles conjugated with antibodies. Upon the addition of the sample containing bacteria, the florescence of gold nanoclusters is recovered. The assay was evaluated by the naked eye (on/off) and quantitatively with use of a smartphone camera. The biosensor proved to be highly specific and sensitive, achieving a limit of detection as low as 4.0 cfu mL. Additionally, recoveries of 110% and 95% were obtained when the platforms in spiked river and tap water, respectively, were evaluated.
Dipòsit Digital de Documents de la UAB
Publication Artículo científico (JournalArticle)

Nano-lantern on paper for smartphone-based ATP detection

  • Calabretta, Maria Maddalena|||0000-0002-5673-3073
  • Álvarez Diduk, Ruslan|||0000-0002-9876-1574
  • Michelini, Elisa
  • Roda, Aldo
  • Merkoçi, Arben|||0000-0003-2486-8085
ATP-driven bioluminescence relying on the D-luciferin-luciferase reaction is widely employed for several biosensing applications where bacterial ATP detection allows to verify microbial contamination for hygiene monitoring in hospitals, food processing and in general for cell viability studies. Several ATP kit assays are already commercially available but an user-friendly ATP biosensor characterized by low-cost, portability, and adequate sensitivity would be highly valuable for rapid and facile on site screening. Thanks to an innovative freeze-drying procedure, we developed a user-friendly, ready-to-use and stable ATP sensing paper biosensor that can be combined with smartphone detection. The ATP sensing paper includes a lyophilized "nano-lantern" with reaction components being rapidly reconstituted by 10 μL sample addition, enabling detection of 10 mol of ATP within 10 min. We analysed urinary microbial ATP as a biomarker of urinary tract infection (UTI), confirming the capability of the ATP sensing paper to detect the threshold for positivity corresponding to 10 colony-forming units of bacteria per mL of urine.
Dipòsit Digital de Documents de la UAB
Publication Artículo científico (JournalArticle)

Inkjet-printed electrochemically reduced graphene oxide microelectrode as a platform for HT-2 mycotoxin immunoenzymatic biosensing

  • Kudr, Jiri|||0000-0002-2058-4563
  • Zhao, Lei|||0000-0003-0291-2655
  • Nguyen, Emily P.|||0000-0003-4299-2055
  • Arola, Henri
  • Nevanen, Tarja K.
  • Adam, Vojtech
  • Zitka, Ondrej
  • Merkoçi, Arben|||0000-0003-2486-8085
The design and application of an inkjet-printed electrochemically reduced graphene oxide microelectrode for HT-2 mycotoxin immunoenzymatic biosensing is reported. A water-based graphene oxide ink was first formulated and single-drop line working microelectrodes were inkjet-printed onto poly(ethylene 2,6-naphthalate) substrates, with dimensions of 78 μm in width and 30 nm in height after solvent evaporation. The printed graphene oxide microelectrodes were electrochemically reduced and characterized by Raman and X-ray photoelectron spectroscopies in addition to microscopies. Through optimization of the electrochemical reduction parameters, differential pulse voltammetry were performed to examine the sensing of 1-naphthol (1-N), where it was revealed that reduction times had significant effects on electrode performance. The developed microelectrodes were then used as an immunoenzymatic biosensor for the detection of HT-2 mycotoxin based on carbodiimide linking of the microelectrode surface and HT-2 toxin antigen binding fragment of antibody (anti-HT2 (10) Fab). The HT-2 toxin and anti-HT2 (10) Fab reaction was reported by anti-HT2 immune complex single-chain variable fragment of antibody fused with alkaline phosphatase (anti-IC-HT2 scFv-ALP) which is able to produce an electroactive reporter - 1-N. The biosensor showed detection limit of 1.6 ng ∙ mL¯¹ and a linear dynamic range of 6.3 - 100.0 ng ∙ mL¯¹ within a 5 min incubation with 1-naphthyl phosphate (1-NP) substrate.
Dipòsit Digital de Documents de la UAB
Publication Artículo científico (JournalArticle)

Recent advancement in biomedical applications on the surface of two-dimensional materials, from biosensing to tissue engineering

  • Nguyen, Emily P.|||0000-0003-4299-2055
  • De Carvalho Castro Silva, Cecilia|||0000-0003-3933-1838
  • Merkoçi, Arben|||0000-0003-2486-8085
As biosensors and biomedical devices have become increasingly important to everyday diagnostics and monitoring, there are tremendous, and constant efforts towards developing and improving the reliability and versatility of such technology. As they offer high surface area-to-volume ratios and a diverse range of properties, from electronic to optical, two dimensional (2D) materials have proven to be very promising candidates for biological applications and technologies. Due to the dimensionality, 2D materials facilitate many interfacial phenomena that have shown to significantly improve the performance of biosensors, while recent advances in synthesis techniques and surface engineering methods also enable the realization of future biomedical devices. This short review aims to highlight the influence of 2D material surfaces and the properties that arise due to their 2D structure. Using recent (within the last few years) examples of biosensors and biomedical applications, we emphasize the important role of 2D materials in advancing developments and research for biosensing and healthcare.
Dipòsit Digital de Documents de la UAB
Publication Artículo científico (JournalArticle)

Organic-based field effect transistors for protein detection fabricated by inkjet-printing

  • Martinez Domingo, Carme|||0000-0002-1897-5362
  • Conti, Silvia
  • De La Escosura-Muñiz, Alfredo|||0000-0002-9600-0253
  • Terés, Lluís
  • Merkoçi, Arben|||0000-0003-2486-8085
  • Ramon, Eloi|||0000-0001-9974-8112
Biosensors based on Organic Field-Effect Transistors (OFETs) have attracted increasing attention due to the possibility of rapid, label-free, and inexpensive detection. Among all the different possibilities, inkjet-printed top-gate organic Field Effect Transistors-Based Biosensors (BioFETs) using a polymeric gate insulator have been seldom reported. In this work, a systematic investigation in terms of topographical and electrical characterization was carried out in order to find the optimal fabrication process for obtaining a reliable polymer insulator. Previous studies have demonstrated that the best electrical performance arises from the use of the perfluoropolymer Cytop™[12,13,14]. Consequently, a simple immobilization protocol was used to ensure the proper attachment of a model biomolecule onto the Cytop's hydrophobic surface whilst keeping its remarkable insulating properties with gate current in the range of dozens of pico-amperes. The top-gate inkjet-printed BioFETs presented in this study operate at threshold voltages in the range of 1-2 V and show durability even when exposed to oxygen plasma, wet amine functionalization treatments, and aqueous media. As a preliminary application, the inkjet-printed top-gate BioFETs is used for monitoring an immunoreaction by measuring changes in the drain current, paving the way for further use of this device in the immunosensing field.
Dipòsit Digital de Documents de la UAB
Publication Artículo científico (JournalArticle)

Nanomaterials for nanotheranostics, tuning their properties according to disease needs

  • Wong, Xin Yi
  • Sena-Torralba, Amadeo|||0000-0003-1340-1383
  • Álvarez Diduk, Ruslan|||0000-0002-9876-1574
  • Muthoosamy, Kasturi
  • Merkoçi, Arben|||0000-0003-2486-8085
Nanotheranostics is one of the biggest scientific breakthroughs in nanomedicine. Most of the currently available diagnosis and therapies are invasive, time-consuming, and associated with severe toxic side effects. Nanotheranostics, on the other hand, has the potential to bridge this gap by harnessing the capabilities of nanotechnology and nanomaterials for combined therapeutics and diagnostics with markedly enhanced efficacy. However, nanomaterial applications in nanotheranostics are still in its infancy. This is due to the fact that each disease has a particular microenvironment with well-defined characteristics, which promotes deeper selection criteria of nanomaterials to meet the disease needs. In this review, we have outlined how nanomaterials are designed and tailored for nanotheranostics of cancer and other diseases such as neurodegenerative, autoimmune (particularly on rheumatoid arthritis), and cardiovascular diseases. The penetrability and retention of a nanomaterial in the biological system, the therapeutic strategy used, and the imaging mode selected are some of the aspects discussed for each disease. The specific properties of the nanomaterials in terms of feasibility, physicochemical challenges, progress in clinical trials, its toxicity, and their future application on translational medicine are addressed. Our review meticulously and critically examines the applications of nanotheranostics with various nanomaterials, including graphene, across several diseases, offering a broader perspective of this emerging field.
Dipòsit Digital de Documents de la UAB
Publication Artículo científico (JournalArticle)

Lateral flow assay modified with time-delay wax barriers as a sensitivity and signal enhancement strategy

  • Sena-Torralba, Amadeo|||0000-0003-1340-1383
  • Ngo, Duy Ba
  • Parolo, Claudio|||0000-0001-9481-4408
  • Hu, Liming|||0000-0002-8666-9287
  • Álvarez Diduk, Ruslan|||0000-0002-9876-1574
  • Bergua Canudo, José Francisco|||0000-0002-5969-193X
  • Rosati, Giulio|||0000-0002-0227-4561
  • Surareungchai, Werasak
  • Merkoçi, Arben|||0000-0003-2486-8085
The ease of use, low cost and quick operation of lateral flow assays (LFA) have made them some of the most common point of care biosensors in a variety of fields. However, their generally low sensitivity has limited their use for more challenging applications, where the detection of low analytic concentrations is required. Here we propose the use of soluble wax barriers to selectively and temporarily accumulate the target and label nanoparticles on top of the test line (TL). This extended internal incubation step promotes the formation of the immune-complex, generating a 51.7-fold sensitivity enhancement, considering the limit of quantification, and up to 96% signal enhancement compared to the conventional LFA for Human IgG (H-IgG) detection.
Dipòsit Digital de Documents de la UAB
Publication Artículo científico (JournalArticle)

Experimental comparison in sensing breast cancer mutations by signal on and signal off paper-based electroanalytical strips

  • Cinti, Stefano|||0000-0002-8274-7452
  • Cinotti, Giulia
  • Parolo, Claudio|||0000-0001-9481-4408
  • Nguyen, Emily P.|||0000-0003-4299-2055
  • Caratelli, Veronica
  • Moscone, Danila
  • Arduini, Fabiana
  • Merkoçi, Arben|||0000-0003-2486-8085
The development of paper-based electroanalytical strips as powerful diagnostic tools has gained a lot of attention within the sensor community. In particular, the detection of nucleic acids in complex matrices represents a trending topic, especially when focused toward the development of emerging technologies, such as liquid biopsy. DNA-based biosensors have been largely applied in this direction, and currently, there are two main approaches based on target/probe hybridization reported in the literature, namely Signal ON and Signal OFF. In this technical note, the two approaches are evaluated in combination with paper-based electrodes, using a single strand DNA relative to H1047R (A3140G) missense mutation in exon 20 in breast cancer as the model target. A detailed comparison among the analytical performances, detection protocol, and cost associated with the two systems is provided, highlighting the advantages and drawbacks depending on the application. The present work is aimed to a wide audience, particularly for those in the field of point-of-care, and it is intended to provide the know-how to manage with the design and development stages, and to optimize the platform for the sensing of nucleic acids using a paper-based detection method.
Dipòsit Digital de Documents de la UAB
Publication Artículo científico (JournalArticle)

Smart chip for visual detection of bacteria using the electrochromic properties of polyaniline

  • Ranjbar, Saba|||0000-0003-4746-3099
  • Nejad, Mohammad Amin Farahmand
  • Parolo, Claudio|||0000-0001-9481-4408
  • Shahrokhian, Saeed|||0000-0003-3138-6578
  • Merkoçi, Arben|||0000-0003-2486-8085
Finding fast and reliable ways to detect pathogenic bacteria is crucial for addressing serious public health issues in clinical, environmental, and food settings. Here, we present a novel assay based on the conversion of an electrochemical signal into a more convenient optical readout for the visual detection of Escherichia coli. Electropolymerizing polyaniline (PANI) on an indium tin oxide screen-printed electrode (ITO SPE), we achieved not only the desired electrochromic behavior but also a convenient way to modify the electrode surface with antibodies (taking advantage of the many amine groups of PANI). Applying a constant potential to the PANI-modified ITO SPE induces a change in their oxidation state, which in turn generates a color change on the electrode surface. The presence of E. coli on the electrode surface increases the resistance in the circuit affecting the PANI oxidation states, producing a different electrochromic response. Using this electrochromic sensor, we could measure concentrations of E. coli spanning 4 orders of magnitude with a limit of detection of 10 colony forming unit per 1 mL (CFU mL) by the naked eye and 10 CFU mL using ImageJ software. In this work we show that merging the sensitivity of electrochemistry with the user-friendliness of an optical readout can generate a new and powerful class of biosensors, with potentially unlimited applications in a variety of fields.
Dipòsit Digital de Documents de la UAB
Publication Artículo científico (JournalArticle)

A nitrocellulose paper strip for fluorometric determination of bisphenol A using molecularly imprinted nanoparticles

  • Üzek, Recep|||0000-0002-7566-7817
  • Sari, Esma
  • Şenel, Serap
  • Denizli, Adil
  • Merkoçi, Arben|||0000-0003-2486-8085
The authors describe a test stripe for fluorometric determination of the endocrine disruptor bisphenol A (BPA). Graphene quantum dots (GQDs) were immobilized on molecularly imprinted nanoparticles which then were placed on nitrocellulose paper. The GQDs display blue fluorescence (with excitation/emission peaks at 350/440 nm) which is reduced in the presence of BPA. The test stripe has a 43.9 ± 0.8 μg.L¯¹ limit of detection in case of water samples. The stripe was applied to the determination of BPA in (spiked) tap water and sea water, and the LODs were found to be 1.8 ± 0.2 μg·L¯¹ and 4.2 ± 0.5 μg·L¯¹ , respectively. Structural analogs of BPA, such as aminophenol, phenol, hydroquinone and naphthol were found not to interfere.
Dipòsit Digital de Documents de la UAB
Publication Artículo científico (JournalArticle)

Optical-based (Bio) sensing systems using magnetic nanoparticles

  • Üzek, Recep|||0000-0002-7566-7817
  • Sari, Esma
  • Merkoçi, Arben|||0000-0003-2486-8085
In recent years, various reports related to sensing application research have suggested that combining the synergistic impacts of optical, electrical or magnetic properties in a single technique can lead to a new multitasking platform. Owing to their unique features of the magnetic moment, biocompatibility, ease of surface modification, chemical stability, high surface area, high mass transference, magnetic nanoparticles have found a wide range of applications in various fields, especially in sensing systems. The present review is comprehensive information about magnetic nanoparticles utilized in the optical sensing platform, broadly categorized into four types: surface plasmon resonance (SPR), surface-enhanced Raman spectroscopy (SERS), fluorescence spectroscopy and near-infrared spectroscopy and imaging (NIRS) that are commonly used in various (bio) analytical applications. The review also includes some conclusions on the state of the art in this field and future aspects.
Dipòsit Digital de Documents de la UAB
Publication Artículo científico (JournalArticle)

Paper-based electrophoretic bioassay, biosensing in whole blood operating via smartphone

  • Sena-Torralba, Amadeo|||0000-0003-1340-1383
  • Álvarez Diduk, Ruslan|||0000-0002-9876-1574
  • Parolo, Claudio|||0000-0001-9481-4408
  • Torné-Morató, Helena
  • Müller, Alexander
  • Merkoçi, Arben|||0000-0003-2486-8085
Point-of-care (PoC) tests are practical and effective diagnostic solutions for major clinical problems, ranging from the monitoring of a pandemic to recurrent or simple measurements. Although, in recent years, a great improvement in the analytical performance of such sensors has been observed, there is still a major issue that has not been properly solved: The ability to perform adequate sample treatments. The main reason is that normally sample treatments require complicated or long procedures not adequate for deployment at the PoC. In response, a sensing platform, called paperbased electrophoretic bioassay (PEB), that combines the key characteristics of a lateral flow assay (LFA) with the sample treatment capabilities of electrophoresis is developed. In particular, the ability of PEB to separate different types of particles and to detect human antibodies in untreated spiked whole blood is demonstrated. Finally, to make the platform suitable for PoC, PEB is coupled with a smartphone that controls the electrophoresis and reads the optical signal generated. It is believed that the PEB platform represents a much-needed solution for the detection of low target concentrations in complex media, solving one of the major limitations of LFA and opening opportunities for point-of-care sensors.
Dipòsit Digital de Documents de la UAB
Publication Artículo científico (JournalArticle)

Nanodiagnostics to face SARS-CoV-2 and future pandemics, from an idea to the market and beyond

  • Rosati, Giulio|||0000-0002-0227-4561
  • Idili, Andrea|||0000-0002-6004-270X
  • Parolo, Claudio|||0000-0001-9481-4408
  • Fuentes-Chust, Celia|||0000-0002-8945-8514
  • Calucho, Enric|||0000-0002-6024-765X
  • Hu, Liming|||0000-0002-8666-9287
  • De Carvalho Castro Silva, Cecilia|||0000-0003-3933-1838
  • Rivas, Lourdes|||0000-0002-1510-5927
  • Nguyen, Emily P.|||0000-0003-4299-2055
  • Bergua Canudo, José Francisco|||0000-0002-5969-193X
  • Álvarez Diduk, Ruslan|||0000-0002-9876-1574
  • Muñoz, Jose|||0000-0001-9529-6980
  • Junot, Christophe
  • Penon, Oriol|||0000-0003-0811-9631
  • Monferrer, Dominique
  • Delamarche, Emmanuel|||0000-0002-8753-8895
  • Merkoçi, Arben|||0000-0003-2486-8085
The COVID-19 pandemic made clear how our society requires quickly available tools to address emerging healthcare issues. Diagnostic assays and devices are used every day to screen for COVID-19 positive patients, with the aim to decide the appropriate treatment and containment measures. In this context, we would have expected to see the use of the most recent diagnostic technologies worldwide, including the advanced ones such as nano-biosensors capable to provide faster, more sensitive, cheaper, and high-throughput results than the standard polymerase chain reaction and lateral flow assays. Here we discuss why that has not been the case and why all the exciting diagnostic strategies published on a daily basis in peer-reviewed journals are not yet successful in reaching the market and being implemented in the clinical practice.
Dipòsit Digital de Documents de la UAB
Publication Artículo científico (JournalArticle)

Integrating gold nanoclusters, folic acid and reduced graphene oxide for nanosensing of glutathione based on "turn-off" fluorescence

  • Wong, Xin Yi
  • Quesada-González, Daniel|||0000-0003-3064-2146
  • Manickam, Sivakumar
  • New, Siu Yee
  • Muthoosamy, Kasturi
  • Merkoçi, Arben|||0000-0003-2486-8085
Glutathione (GSH) is a useful biomarker in the development, diagnosis and treatment of cancer. However, most of the reported GSH biosensors are expensive, time-consuming and often require complex sample treatment, which limit its biological applications. Herein, a nanobiosensor for the detection of GSH using folic acid-functionalized reduced graphene oxide-modified BSA gold nanoclusters (FA-rGO-BSA/AuNCs) based on the fluorescence quenching interactions is presented. Firstly, a facile and optimized protocol for the fabrication of BSA/AuNCs is developed. Functionalization of rGO with folic acid is performed using EDC/NHS cross-linking reagents, and their interaction after loading with BSA/AuNCs is demonstrated. The formation of FA-rGO, BSA/AuNCs and FA-rGO-BSA/AuNCs are confirmed by the state-of-art characterization techniques. Finally, a fluorescence turn-off sensing strategy is developed using the as-synthesized FA-rGO-BSA/AuNCs for the detection of GSH. The nanobiosensor revealed an excellent sensing performance for the detection of GSH with high sensitivity and desirable selectivity over other potential interfering species. The fluorescence quenching is linearly proportional to the concentration of GSH between 0 and 1.75 µM, with a limit of detection of 0.1 µM under the physiological pH conditions (pH 7.4). Such a sensitive nanobiosensor paves the way to fabricate a "turn-on" or "turn-off" fluorescent sensor for important biomarkers in cancer cells, presenting potential nanotheranostic applications in biological detection and clinical diagnosis.
Dipòsit Digital de Documents de la UAB
Publication Artículo científico (JournalArticle)

Graphene nanobeacons with high-affinity pockets for combined, selective, and effective decontamination and reagentless detection of heavy metals

  • Panáček, David
  • Zdražil, Lukáš
  • Langer, Michal
  • Šedajová, Veronika|||0000-0002-1635-1206
  • Baďura, Zdeněk
  • Zoppellaro, Georgio
  • Yang, Qiuyue|||0000-0002-7693-6679
  • Nguyen, Emily P.|||0000-0003-4299-2055
  • Álvarez Diduk, Ruslan|||0000-0002-9876-1574
  • Hrubý, Vítězslav
  • Kolařík, Jan
  • Chalmpes, Nikolaos
  • Bourlinos, Athanasios B.
  • Zboril, Radek|||0000-0002-3147-2196
  • Merkoçi, Arben|||0000-0003-2486-8085
  • Bakandritsos, Aristides|||0000-0003-4411-9348
  • Otyepka, Michal|||0000-0002-1066-5677
Access to clean water for drinking, sanitation, and irrigation is a major sustainable development goal of the United Nations. Thus, technologies for cleaning water and quality-monitoring must become widely accessible and of low-cost, while being effective, selective, sustainable, and eco-friendly. To meet this challenge, hetero-bifunctional nanographene fluorescent beacons with high-affinity pockets for heavy metals are developed, offering top-rated and selective adsorption for cadmium and lead, reaching 870 and 450 mg g, respectively. The heterobifunctional and multidentate pockets also operate as selective gates for fluorescence signal regulation with sub-nanomolar sensitivity (0.1 and 0.2 nm for Pb and Cd, respectively), due to binding affinities as low as those of antigen-antibody interactions. Importantly, the acid-proof nanographenes can be fully regenerated and reused. Their broad visible-light absorption offers an additional mode for water-quality monitoring based on ultra-low cost and user-friendly reagentless paper detection with the naked-eye at a limit of detection of 1 and 10 ppb for Pb and Cd ions, respectively. This work shows that photoactive nanomaterials, densely-functionalized with strong, yet selective ligands for targeted contaminants, can successfully combine features such as excellent adsorption, reusability, and sensing capabilities, in a way to extend the material's applicability, its life-cycle, and value-for-money.
Dipòsit Digital de Documents de la UAB
Publication Artículo científico (JournalArticle)

Low-Cost, User-Friendly, All-Integrated Smartphone-Based Microplate Reader for Optical-Based Biological and Chemical Analyses

  • Bergua Canudo, José Francisco|||0000-0002-5969-193X
  • Álvarez Diduk, Ruslan|||0000-0002-9876-1574
  • Idili, Andrea|||0000-0002-6004-270X
  • Parolo, Claudio|||0000-0001-9481-4408
  • Maymó, M.
  • Hu, Liming|||0000-0002-8666-9287
  • Merkoçi, Arben|||0000-0003-2486-8085
The quantitative detection of different molecular targets is of utmost importance for a variety of human activities, ranging from healthcare to environmental studies. Bioanalytical methods have been developed to solve this and to achieve the quantification of multiple targets from small volume samples. Generally, they can be divided into two different classes: point of care (PoC) and laboratory-based approaches. The former is rapid, low-cost, and user-friendly; however, the majority of the tests are semiquantitative, lacking in specificity and sensitivity. On the contrary, laboratory-based approaches provide high sensitivity and specificity, but the bulkiness of experimental instruments and complicated protocols hamper their use in resource-limited settings. In response, here we propose a smartphone-based device able to support laboratory-based optical techniques directly at the point of care. Specifically, we designed and fabricated a portable microplate reader that supports colorimetric, fluorescence, luminescence, and turbidity analyses. To demonstrate the potential of the device, we characterized its analytical performance by detecting a variety of relevant molecular targets (ranging from antibodies, toxins, drugs, and classic fluorophore dyes) and we showed how the estimated results are comparable to those obtained from a commercial microplate reader. Thanks to its low cost (<
Dipòsit Digital de Documents de la UAB
Publication Artículo científico (JournalArticle)

Integrated devices for non-invasive diagnostics

  • Ates, Hatice Ceren|||0000-0001-7882-4745
  • Brunauer, Anna
  • von Stetten, Felix
  • Urban, Gerald Anton
  • Güder, Firat|||0000-0001-5454-0609
  • Merkoçi, Arben|||0000-0003-2486-8085
  • Früh, Susanna Maria
  • Dincer, Can|||0000-0003-3301-1198
"Sample-in-answer-out" type integrated diagnostic devices have been widely recognized as the ultimate solution to simplify testing across healthcare systems. Such systems are equipped with advanced fluidic, mechanical, chemical, biological, and electronic components to handle patient samples without any manual steps therefore have the potential to accelerate intervention and improve patient outcomes. In this regard, the combination of integrated devices and non-invasive sampling has gained a substantial interest to further improve the comfort and safety of patients. In this Review, the pioneering developments in integrated diagnostics are covered and their potential in non-invasive sampling is discussed. The key properties of possible sample types are highlighted by addressing their relevance for the clinical practice. Last, the factors affecting the transition of integrated devices from academia to the market are identified by analyzing the technology readiness levels of selected examples and alternative remedies are explored to increase the rate of survival during this transition.
Dipòsit Digital de Documents de la UAB
Publication Artículo científico (JournalArticle)

Wearable and fully printed microfluidic nanosensor for sweat rate, conductivity, and copper detection with healthcare applications

  • Yang, Qiuyue|||0000-0002-7693-6679
  • Rosati, Giulio|||0000-0002-0227-4561
  • Abarintos, Vernalyn|||0000-0002-3218-0937
  • Aroca, Miguel A.|||0000-0003-3097-9048
  • Osma, Johann F.|||0000-0003-2928-3406
  • Merkoçi, Arben|||0000-0003-2486-8085
Wearables are becoming pervasive in our society, but they are still mainly based on physical sensors with just few optical and electrochemical exceptions. Sweat, amongst other body fluids, is easily and non-invasively accessible, abundant, and relatively poor of interfering species. The biomarkers of interest in sweat space from ions and small molecules to whole organisms. Heavy metals have been found being biomarkers of several diseases and pathological conditions. Copper in particular is correlated to Wilson's disease and liver cirrhosis among others. Nevertheless, several issues such as sampling conditions, sweat rate normalization, reliable continuous monitoring, and typically expensive fabrication methods still needs to be addressed in sweat analysis with wearables. Herein, we propose a fully printed wearable microfluidic nanosensor with an integrated wireless smartphone-based readout. Our system can easily be applied on the skin and actively stimulate perspiration, normalizing the heavy metals concentration with respect to the volume of the sample and the sweat rate. The system has a limit of detection of 396 ppb, a linear range up to 2500 ppb and a sensitivity of 2.3 nA/ppb.
Dipòsit Digital de Documents de la UAB
Publication Artículo científico (JournalArticle)

A novel ratiometric fluorescent approach for the modulation of the ydnamic range of lateral flow immunoassays

  • Sena-Torralba, Amadeo|||0000-0003-1340-1383
  • Torné-Morató, Helena
  • Parolo, Claudio|||0000-0001-9481-4408
  • Ranjbar, Saba|||0000-0003-4746-3099
  • Nejad, Mohammad Amin Farahmand
  • Álvarez Diduk, Ruslan|||0000-0002-9876-1574
  • Idili, Andrea|||0000-0002-6004-270X
  • Hormozi-Nezhad, M.R.
  • Merkoçi, Arben|||0000-0003-2486-8085
The majority of lateral flow assays (LFAs) use single-color optical labels to provide a qualitative naked-eye detection, however this detection method displays two important limitations. First, the use of a single-color label makes the LFA prone to results misinterpretation. Second, it does not allow the precise modulation of the sensitivity and dynamic range of the test. To overcome these limitations, a ratiometric approach is developed. In particular, using anti-HIgG functionalized red-fluorescent quantum dots on the conjugate pad (as target dependent labels) and blue-fluorescent nanoparticles fixed on the test line (as target independent reporters), it is possible to generate a wide color palette (blue, purple, pink, red) on the test line. It is believed that this strategy will facilitate the development of LFAs by easily adjusting their analytical properties to the needs required by the specific application.
Dipòsit Digital de Documents de la UAB
Publication Artículo científico (JournalArticle)

Paper-based biosensors for cancer diagnostics

  • Pereira, Claudia
  • Parolo, Claudio|||0000-0001-9481-4408
  • Idili, Andrea|||0000-0002-6004-270X
  • Gomis, Roger R..|||0000-0001-6473-2858
  • Rodrigues, Lígia
  • Sales, Goreti
  • Merkoçi, Arben|||0000-0003-2486-8085
The implementation of a wide diagnostic campaign to diagnose cancer early could save millions of lives and billions of dollars every year. Unfortunately, cancer diagnosis is extremely complicated and current approaches rely on the use of expensive equipment and specialized personnel, which hamper their deployment in low- and middle-income settings. Here, we analyze the technical challenges that must be overcome to achieve precise cancer diagnostics and we describe how such hurdles have limited the development of point-of-care (PoC) sensors. Then, we explain why we believe recent achievements in the field of paper-based sensors could allow their use as widely available sensing platforms for cancer detection. Finally, we present our vision of what should be done in order to make paper-based sensors widely used diagnostics platforms for cancer.
Dipòsit Digital de Documents de la UAB
Publication Artículo científico (JournalArticle)

Metal-free cysteamine-functionalized graphene alleviates mutual interferences in heavy metal electrochemical detection

  • Yang, Qiuyue|||0000-0002-7693-6679
  • Nguyen, Emily P.|||0000-0003-4299-2055
  • Panáček, David
  • Šedajová, Veronika|||0000-0002-1635-1206
  • Hrubý, Vítězslav
  • Rosati, Giulio|||0000-0002-0227-4561
  • De Carvalho Castro Silva, Cecilia|||0000-0003-3933-1838
  • Bakandritsos, Aristides|||0000-0003-4411-9348
  • Otyepka, Michal|||0000-0002-1066-5677
  • Merkoçi, Arben|||0000-0003-2486-8085
Heavy metal pollutants are of great concern to environmental monitoring due to their potent toxicity. Electrochemical detection, one of the main techniques, is hindered by the mutual interferences of various heavy metal ions in practical use. In particular, the sensitivity of carbon electrodes to Cd 2+ ions (one of the most toxic heavy metals) is often overshadowed by some heavy metals (e.g. Pb 2+ and Cu 2+). To mitigate interference, metallic particles/films (e.g. Hg, Au, Bi, and Sn) typically need to be embedded in the carbon electrodes. However, these additional metallic materials may face issues of secondary pollution and unsustainability. In this study, a metal-free and sustainable nanomaterial, namely cysteamine covalently functionalized graphene (GSH), was found to lead to a 6-fold boost in the Cd 2+ sensitivity of the screen-printed carbon electrode (SPCE), while the sensitivities to Pb 2+ and Cu 2+ were not influenced in simultaneous detection. The selective enhancement could be attributed to the grafted thiols on GSH sheets with good affinity to Cd 2+ ions based on Pearson's hard and soft acid and base principle. More intriguingly, the GSH-modified SPCE (GSH-SPCE) featured high reusability with extended cycling times (23 times), surpassing the state-of-art SPCEs modified by non-covalently functionalized graphene derivatives. Last, the GSH-SPCE was validated in tap water. A metal-free thiol-modified graphene derivative introduces a reusable approach to alleviate mutual interference in electrochemical heavy metal detection.