Skip to main content

Resultados relacionados

Resultados totales (Incluyendo duplicados): 6
Encontrada(s) 1 página(s)

DIGITAL.CSIC. Repositorio Institucional del CSIC
Publication Artículo científico (JournalArticle)

Label-free and reagentless electrochemical genosensor based on graphene acid for meat adulteration detection

  • Flauzino, José M. R.
  • Nguyen, Emily P.
  • Yang, Qiuyue
  • Rosati, Giulio
  • Panáček, David
  • Brito-Madurro, Ana G.
  • Madurro, João M.
  • Bakandritsos, Aristides
  • Otyepka, Michal
  • Merkoçi, Arben
With the increased demand for beef in emerging markets, the development of quality-control diagnostics that are fast, cheap and easy to handle is essential. Especially where beef must be free from pork residues, due to religious, cultural or allergic reasons, the availability of such diagnostic tools is crucial. In this work, we report a label-free impedimetric genosensor for the sensitive detection of pork residues in meat, by leveraging the biosensing capabilities of graphene acid - a densely and selectively functionalized graphene derivative. A single stranded DNA probe, specific for the pork mitochondrial genome, was immobilized onto carbon screen-printed electrodes modified with graphene acid. It was demonstrated that graphene acid improved the charge transport properties of the electrode, following a simple and rapid electrode modification and detection protocol. Using non-faradaic electrochemical impedance spectroscopy, which does not require any electrochemical indicators or redox pairs, the detection of pork residues in beef was achieved in less than 45 min (including sample preparation), with a limit of detection of 9% w/w pork content in beef samples. Importantly, the sample did not need to be purified or amplified, and the biosensor retained its performance properties unchanged for at least 4 weeks. This set of features places the present pork DNA sensor among the most attractive for further development and commercialization. Furthermore, it paves the way for the development of sensitive and selective point-of-need sensing devices for label-free, fast, simple and reliable monitoring of meat purity., We acknowledge funding from the European Union Horizon2020 Programme under Grant No. 881603 (Graphene Flagship Core 3). This article reflects only the author's view, and the European Commission is not responsible for any use that may be made of the information it contains. ICN2 is funded by the CERCA programme, Generalitat de Catalunya. The ICN2 is supported by the Severo Ochoa Centres of Excellence programme, funded by the Spanish Research Agency (AEI, grant no. SEV-2017-0706). J. M. R. Flauzino is grateful for the Coordenação de Aperfeiçoamento de Pessoal de Nível Superior scholarship (CAPES-PRINT, Brazil, Grant number: 88887.371591/2019–00). D. Panáček acknowledges the Internal Student Grant Agency of the Palacký University in Olomouc, (IGA_PrF_2021_031). A. G. Brito-Madurro acknowledges the funding from Conselho Nacional de Desenvolvimento Científico e Tecnológico - CNPq (310782/2018–0). J. M. Madurro acknowledges the funding from Fundação de Amparo à Pesquisa do Estado de Minas Gerais – FAPEMIG (CEX-APQ-02902-17) and Conselho Nacional de Desenvolvimento Científico e Tecnológico – CNPq (311737/2018–8). A. Bakandritsos acknowledges the funding from the Czech Science Foundation, (project GA CR – EXPRO, 19–27454X). M. Otyepka acknowledges the ERC grand 2D-CHEM (No 683024 from H202). The work was supported also by the ERDF/ESF project “Nano4Future” (No.CZ.02.1.01/0.0/0.0/16_019/0000754).
DIGITAL.CSIC. Repositorio Institucional del CSIC
Publication Artículo científico (JournalArticle)

Graphene Nanobeacons with High-Affinity Pockets for Combined, Selective, and Effective Decontamination and Reagentless Detection of Heavy Metals

  • Panáček, David
  • Zdražil, Lukáš
  • Langer, Michal
  • Šedajová, Veronika
  • Baďura, Zdeněk
  • Zoppellaro, Giorgio
  • Yang, Qiuyue
  • Nguyen, Emily P.
  • Álvarez-Diduk, Ruslan
  • Hrubý, Vítězslav
  • Kolařík, Jan
  • Chalmpes, Nikolaos
  • Bourlinos, Athanasios B.
  • Zboril, Radek
  • Merkoçi, Arben
  • Bakandritsos, Aristides
  • Otyepka, Michal
Access to clean water for drinking, sanitation, and irrigation is a major sustainable development goal of the United Nations. Thus, technologies for cleaning water and quality-monitoring must become widely accessible and of low-cost, while being effective, selective, sustainable, and eco-friendly. To meet this challenge, hetero-bifunctional nanographene fluorescent beacons with high-affinity pockets for heavy metals are developed, offering top-rated and selective adsorption for cadmium and lead, reaching 870 and 450 mg g, respectively. The heterobifunctional and multidentate pockets also operate as selective gates for fluorescence signal regulation with sub-nanomolar sensitivity (0.1 and 0.2 nm for Pb and Cd, respectively), due to binding affinities as low as those of antigen-antibody interactions. Importantly, the acid-proof nanographenes can be fully regenerated and reused. Their broad visible-light absorption offers an additional mode for water-quality monitoring based on ultra-low cost and user-friendly reagentless paper detection with the naked-eye at a limit of detection of 1 and 10 ppb for Pb and Cd ions, respectively. This work shows that photoactive nanomaterials, densely-functionalized with strong, yet selective ligands for targeted contaminants, can successfully combine features such as excellent adsorption, reusability, and sensing capabilities, in a way to extend the material's applicability, its life-cycle, and value-for-money., The work was supported by the ERDF/ESF project “Nano4Future” (No. CZ.02.1.01/0.0/0.0/16_019/0000754). R.Z. and A.B. acknowledge the funding from the Czech Science Foundation, GA CR–EXPRO, 19-27454X. D.P., L.Z., V.Š., M.L., and V.H. thank the Internal Student Grant Agency of the Palacký University in Olomouc, Czech Republic (IGA_PrF_2022_019). M.O. acknowledges the ERC grant 2D-CHEM, No 683024 from H2020. Operation of XPS and TEM facilities was partly funded by the Research Infrastructure NanoEnviCz, supported by the Ministry of Education, Youth and Sports of the Czech Republic under Project No. LM2018124. N.C. gratefully acknowledges the IKY foundation for the financial support. N.C. and A.B.B. also thank the European Social Fund-ESF (co-financed by Greece and the European Union) through the Operational Programme “Human Resources Development, Education and Lifelong Learning” in the context of the project “Strengthening Human Resources Research Potential via Doctorate Research” (MIS-5000432), implemented by the State Scholarships Foundation (IKY). Computational resources were supplied by the project “e-Infrastruktura CZ” (e-INFRA CZ LM2018140) supported by the Ministry of Education, Youth, and Sports of the Czech Republic. This work was supported by the Ministry of Education, Youth, and Sports of the Czech Republic through the e-INFRA CZ (ID:90140). ICN2 is funded by CERCA programme, Generalit de Catalunya. Grant SEV-2017-0706 by MCIN/AEI/10.13039/501100011033. The authors also acknowledge the project MAT2017-87202-P funded by MCIN/AEI/10.13039/501100011033 and FEDER Una manera de hacer Europa. R.A.-D. acknowledges funding from the European Union Horizon 2020 Programme under Grant No. 881603 (Graphene Flagship Core 3).
DIGITAL.CSIC. Repositorio Institucional del CSIC
Publication Artículo científico (JournalArticle)

Metal-free cysteamine-functionalized graphene alleviates mutual interferences in heavy metal electrochemical detection

  • Yang, Qiuyue
  • Nguyen, Emily P.
  • Panáček, David
  • Šedajová, Veronika
  • Hrubý, Vítězslav
  • Rosati, Giulio
  • Castro Silva, Cecilia de Carvalho
  • Bakandritsos, Aristides
  • Otyepka, Michal
  • Merkoçi, Arben
Heavy metal pollutants are of great concern to environmental monitoring due to their potent toxicity. Electrochemical detection, one of the main techniques, is hindered by the mutual interferences of various heavy metal ions in practical use. In particular, the sensitivity of carbon electrodes to Cd2+ ions (one of the most toxic heavy metals) is often overshadowed by some heavy metals (e.g. Pb2+ and Cu2+). To mitigate interference, metallic particles/films (e.g. Hg, Au, Bi, and Sn) typically need to be embedded in the carbon electrodes. However, these additional metallic materials may face issues of secondary pollution and unsustainability. In this study, a metal-free and sustainable nanomaterial, namely cysteamine covalently functionalized graphene (GSH), was found to lead to a 6-fold boost in the Cd2+ sensitivity of the screen-printed carbon electrode (SPCE), while the sensitivities to Pb2+ and Cu2+ were not influenced in simultaneous detection. The selective enhancement could be attributed to the grafted thiols on GSH sheets with good affinity to Cd2+ ions based on Pearson's hard and soft acid and base principle. More intriguingly, the GSH-modified SPCE (GSH-SPCE) featured high reusability with extended cycling times (23 times), surpassing the state-of-art SPCEs modified by non-covalently functionalized graphene derivatives. Last, the GSH-SPCE was validated in tap water., Grant MAT2017-87202-P funded by MCIN/AEI/ 10.13039/501100011033. ICN2 is funded by CERCA programme, Generalitat de Catalunya. Grant SEV-2017-0706 funded by MCIN/AEI/ 10.13039/501100011033. Q. Y. thanks the funding of the Chinese scholarship council. D. P., V. Š. and V. H. thank the Internal Student Grant Agency of the Palacký University (IGA_PrF_2022_019). C.C.C.S. acknowledges funding through CAPES – PRINT (Programa Institucional de Internacionalização; grant #88887.310281/2018-00 and 88887.467442/2019-00) and Mackpesquisa-UPM. A. B. and M. O. acknowledge support by the project Nano4Future (no. CZ.02.1.01/0.0/0.0/16_019/0000754) financed from the ERDF and ESF. M. O. acknowledges the ERC grant 2D-CHEM, No 683024 from H2020., Peer reviewed
Dipòsit Digital de Documents de la UAB
Publication Artículo científico (JournalArticle)

Graphene nanobeacons with high-affinity pockets for combined, selective, and effective decontamination and reagentless detection of heavy metals

  • Panáček, David
  • Zdražil, Lukáš
  • Langer, Michal
  • Šedajová, Veronika|||0000-0002-1635-1206
  • Baďura, Zdeněk
  • Zoppellaro, Georgio
  • Yang, Qiuyue|||0000-0002-7693-6679
  • Nguyen, Emily P.|||0000-0003-4299-2055
  • Álvarez Diduk, Ruslan|||0000-0002-9876-1574
  • Hrubý, Vítězslav
  • Kolařík, Jan
  • Chalmpes, Nikolaos
  • Bourlinos, Athanasios B.
  • Zboril, Radek|||0000-0002-3147-2196
  • Merkoçi, Arben|||0000-0003-2486-8085
  • Bakandritsos, Aristides|||0000-0003-4411-9348
  • Otyepka, Michal|||0000-0002-1066-5677
Access to clean water for drinking, sanitation, and irrigation is a major sustainable development goal of the United Nations. Thus, technologies for cleaning water and quality-monitoring must become widely accessible and of low-cost, while being effective, selective, sustainable, and eco-friendly. To meet this challenge, hetero-bifunctional nanographene fluorescent beacons with high-affinity pockets for heavy metals are developed, offering top-rated and selective adsorption for cadmium and lead, reaching 870 and 450 mg g, respectively. The heterobifunctional and multidentate pockets also operate as selective gates for fluorescence signal regulation with sub-nanomolar sensitivity (0.1 and 0.2 nm for Pb and Cd, respectively), due to binding affinities as low as those of antigen-antibody interactions. Importantly, the acid-proof nanographenes can be fully regenerated and reused. Their broad visible-light absorption offers an additional mode for water-quality monitoring based on ultra-low cost and user-friendly reagentless paper detection with the naked-eye at a limit of detection of 1 and 10 ppb for Pb and Cd ions, respectively. This work shows that photoactive nanomaterials, densely-functionalized with strong, yet selective ligands for targeted contaminants, can successfully combine features such as excellent adsorption, reusability, and sensing capabilities, in a way to extend the material's applicability, its life-cycle, and value-for-money.
Dipòsit Digital de Documents de la UAB
Publication Artículo científico (JournalArticle)

Label-free and reagentless electrochemical genosensor based on graphene acid for meat adulteration detection

  • Flauzino, J. M. R.
  • Nguyen, Emily P.|||0000-0003-4299-2055
  • Yang, Qiuyue|||0000-0002-7693-6679
  • Rosati, Giulio|||0000-0002-0227-4561
  • Panáček, David
  • Brito-Madurro, Ana G.
  • Madurro, João M.
  • Bakandritsos, Aristides|||0000-0003-4411-9348
  • Otyepka, Michal|||0000-0002-1066-5677
  • Merkoçi, Arben|||0000-0003-2486-8085
With the increased demand for beef in emerging markets, the development of quality-control diagnostics that are fast, cheap and easy to handle is essential. Especially where beef must be free from pork residues, due to religious, cultural or allergic reasons, the availability of such diagnostic tools is crucial. In this work, we report a label-free impedimetric genosensor for the sensitive detection of pork residues in meat, by leveraging the biosensing capabilities of graphene acid - a densely and selectively functionalized graphene derivative. A single stranded DNA probe, specific for the pork mitochondrial genome, was immobilized onto carbon screen-printed electrodes modified with graphene acid. It was demonstrated that graphene acid improved the charge transport properties of the electrode, following a simple and rapid electrode modification and detection protocol. Using non-faradaic electrochemical impedance spectroscopy, which does not require any electrochemical indicators or redox pairs, the detection of pork residues in beef was achieved in less than 45 min (including sample preparation), with a limit of detection of 9% w/w pork content in beef samples. Importantly, the sample did not need to be purified or amplified, and the biosensor retained its performance properties unchanged for at least 4 weeks. This set of features places the present pork DNA sensor among the most attractive for further development and commercialization. Furthermore, it paves the way for the development of sensitive and selective point-of-need sensing devices for label-free, fast, simple and reliable monitoring of meat purity.
Dipòsit Digital de Documents de la UAB
Publication Artículo científico (JournalArticle)

Metal-free cysteamine-functionalized graphene alleviates mutual interferences in heavy metal electrochemical detection

  • Yang, Qiuyue|||0000-0002-7693-6679
  • Nguyen, Emily P.|||0000-0003-4299-2055
  • Panáček, David
  • Šedajová, Veronika|||0000-0002-1635-1206
  • Hrubý, Vítězslav
  • Rosati, Giulio|||0000-0002-0227-4561
  • De Carvalho Castro Silva, Cecilia|||0000-0003-3933-1838
  • Bakandritsos, Aristides|||0000-0003-4411-9348
  • Otyepka, Michal|||0000-0002-1066-5677
  • Merkoçi, Arben|||0000-0003-2486-8085
Heavy metal pollutants are of great concern to environmental monitoring due to their potent toxicity. Electrochemical detection, one of the main techniques, is hindered by the mutual interferences of various heavy metal ions in practical use. In particular, the sensitivity of carbon electrodes to Cd 2+ ions (one of the most toxic heavy metals) is often overshadowed by some heavy metals (e.g. Pb 2+ and Cu 2+). To mitigate interference, metallic particles/films (e.g. Hg, Au, Bi, and Sn) typically need to be embedded in the carbon electrodes. However, these additional metallic materials may face issues of secondary pollution and unsustainability. In this study, a metal-free and sustainable nanomaterial, namely cysteamine covalently functionalized graphene (GSH), was found to lead to a 6-fold boost in the Cd 2+ sensitivity of the screen-printed carbon electrode (SPCE), while the sensitivities to Pb 2+ and Cu 2+ were not influenced in simultaneous detection. The selective enhancement could be attributed to the grafted thiols on GSH sheets with good affinity to Cd 2+ ions based on Pearson's hard and soft acid and base principle. More intriguingly, the GSH-modified SPCE (GSH-SPCE) featured high reusability with extended cycling times (23 times), surpassing the state-of-art SPCEs modified by non-covalently functionalized graphene derivatives. Last, the GSH-SPCE was validated in tap water. A metal-free thiol-modified graphene derivative introduces a reusable approach to alleviate mutual interference in electrochemical heavy metal detection.