Skip to main content

Resultados relacionados

Resultados totales (Incluyendo duplicados): 2
Encontrada(s) 1 página(s)

RiuNet. Repositorio Institucional de la Universitat Politécnica de Valéncia
Publication Artículo científico (JournalArticle)

Low-cost plastic optical fiber integrated with smartphone for human physiological monitoring

  • Kuang, Renfei
  • Ye, Yifan
  • Chen, Ziyan
  • He, Rungie
  • Savovic, Isadora
  • Djordjevic, Alexander
  • Savovic, Svetislav
  • Marques, Carlos
  • Li, Xiaoli
  • Min, Rui
  • Ortega Tamarit, Beatriz|||0000-0003-1196-4756
[EN] Human physiological signal monitoring is a key factor in diagnosing health conditions, such as monitoring heart rate and respiration. To meet the increasing monitoring requirements, such as safety, economy, and equipment miniaturization, it is necessary to optimize and improve the monitoring device. Polymer optical fiber sensor has great potential in human physiological monitoring because of their inherent safety, compactness, electrical isolation, and flexibility. In this paper, we report the integration of low-cost plastic optical fibers in smartphones for the measurement of respiratory rate and heart rate in human physiological monitoring. The performance of the plastic optical fiber (POF) sensor with different sensitivity zone is analyzed. With three sensitivity zones, the respiratory rate and heart rate can be displayed in the power spectral density simultaneously. For improving the POF sensor performance, the shutter speed of the smartphone is also optimized to 30 s(-1). Finally, the POF sensor is tested under different motion states indicate that the sensor can monitor the heart rate and breathing rate under different postures (running, walking, standing, squatting and lying), where the spectral energy is 2.8 +/- 0.11 x 10(8) pt during running and is 1.4 +/- 0.55 x 107 pt in the supine state. And it also can be used to assess the dynamic posture, which is important for some potential sensory applications in clinical and home settings., This research was funded by National Natural Science Foundation of China (62003046, 6211101138); Special Funds for the Cultivation of Guangdong College Students' Scientific and Technological Innovation ("Climbing Program" Special Funds) (pdjh2022a0684); Guangdong Provincial Department of Science and Technology (2021A1313030055); The Innovation Team Project of Guangdong Provincial Department of Education (2021KCXTD014); Special project in key field of Guangdong Provincial Department of Education (2021ZDZX1050); Guangdong Basic and Applied Basic Research Foundation (2021A1515011997).C. Marques acknowledges Fundac ~ao para a Ci <^>encia e a Tecnologia (FCT) through the CEECIND/00034/2018 (iFish project), PTDC/EEI-EEE/0415/2021 (DigiAqua) and this work was developed within the scope of the project i3N, UIDB/50025/2020 & UIDP/50025/2020, financed by national funds through the FCT/MEC.
RiuNet. Repositorio Institucional de la Universitat Politécnica de Valéncia
Publication Artículo científico (JournalArticle)

Wearable cardiorespiratory monitoring with stretchable elastomer optical fiber

  • Zha, B.
  • Wang, Z.
  • Li, L.
  • Hu, X.
  • Li, X.
  • Min, R.
  • Ortega Tamarit, Beatriz|||0000-0003-1196-4756
[EN] This work presents a stretchable elastomer optical fiber sensor incorporated into a belt for respiratory rate (RR) and heart rate (HR) monitoring. Different materials and shapes of prototypes designed were tested in terms of performance and the best choice was identified. The optimal sensor was tested by 10 volunteers to evaluate the performance. The proposed elastomer optical fiber sensor can achieve simultaneous measurement of RR and HR in different body positions, and also ballistocardiography (BCG) signal measurement in the lying position. The sensor has good accuracy and stability, with maximum errors of 1 bpm and 3 bpm for RR and HR, respectively, and average weighted mean absolute percentage error (MAPE) of 5.25% and root mean square error (RMSE) of 1.28 bpm. Moreover, the results of the Bland-Altman method showed good agreement of the sensor with manual counting of RR and with electrocardiogram (ECG) measurements of HR.(c) 2023 Optica Publishing Group under the terms of the Optica Open Access Publishing Agreement, National Key Research and Development Program of China (2022YFE0140400) ; National Natural Science Foundation of China (62003046, 62111530238) ; Basic and Applied Basic Research Foundation of Guangdong Province (2021A1515011997) ; Special project in key field of Guangdong Provincial Department of Education (2021ZDZX1050) ; The Innovation Team Project of Guangdong Provincial Department of Education (2021KCXTD014) .