Skip to main content

Resultados relacionados

Resultados totales (Incluyendo duplicados): 2
Encontrada(s) 1 página(s)

RiuNet. Repositorio Institucional de la Universitat Politécnica de Valéncia
Publication Artículo científico (JournalArticle)

Wearable photonic smart wristband for cardiorespiratory function assessment and biometric identification

  • Li, Wenbo
  • Long, Yukun
  • Yan, Yingyin
  • Xiao, Kun
  • Wang, Zhuo
  • Zheng, Di
  • Leal-Junior, Arnaldo
  • Kumar, Santosh
  • Marques, Carlos
  • Li, Xiaoli
  • Min, Rui
  • Ortega Tamarit, Beatriz|||0000-0003-1196-4756
[EN] Personalized health services are of paramount importance for the treatment and prevention of cardiorespiratory diseases, such as hypertension. The assessment of cardiorespiratory function and biometric identification (ID) is crucial for the effectiveness of such personalized health services. To effectively and accurately monitor pulse wave signals, thus achieving the assessment of cardiorespiratory function, a wearable photonic smart wristband based on an all-polymer sensing unit (All-PSU) is proposed. The smart wristband enables the assessment of cardiorespiratory function by continuously monitoring respiratory rate (RR), heart rate (HR), and blood pressure (BP). Furthermore, it can be utilized for biometric ID purposes. Through the analysis of pulse wave signals using power spectral density (PSD), accurate monitoring of RR and HR is achieved. Additionally, utilizing peak detection algorithms for feature extraction from pulse signals and subsequently employing a variety of machine learning methods, accurate BP monitoring and biometric ID have been realized. For biometric ID, the accuracy rate is 98.55%. Aiming to monitor RR, HR, BP, and ID, our solution demonstrates advantages in integration, functionality, and monitoring precision. These enhancements may contribute to the development of personalized health services aimed at the treatment and prevention of cardiorespiratory diseases., This research funded by the National Key R&D Program of China (2022YFE0140400) ; the National Natural Science Foundation of China (62405027, 62111530238, 62003046) ; Supporting project of major scientific research projects of Beijing Normal University at Zhuhai (ZHPT2023007) ; The work of R.Min was supported by the Tang Scholar of Beijing Normal University.The research was co-funded by the financial support of the European Union under the REFRESH-Research Excellence For REgion Sustainability and High-tech Industries project number CZ.10.03.01/00/22003/0000048 via the Operational Programme Just Transition. This work was developed within the scope of the projects CICECOAveiro Institute of Materials, UIDB/50011/2020 (DOI 10.54499/UIDB/50011/2020) , UIDP/50011/2020 (DOI 10.54499/UIDP/50011/2020) & LA/P/0006/2020 (DOI 10.54499/LA/P/0006/2020) financed by national funds through the FCT/MCTES (PIDDAC) .
RiuNet. Repositorio Institucional de la Universitat Politécnica de Valéncia
Publication Artículo científico (JournalArticle)

Wearable cardiorespiratory monitoring with stretchable elastomer optical fiber

  • Zha, B.
  • Wang, Z.
  • Li, L.
  • Hu, X.
  • Li, X.
  • Min, R.
  • Ortega Tamarit, Beatriz|||0000-0003-1196-4756
[EN] This work presents a stretchable elastomer optical fiber sensor incorporated into a belt for respiratory rate (RR) and heart rate (HR) monitoring. Different materials and shapes of prototypes designed were tested in terms of performance and the best choice was identified. The optimal sensor was tested by 10 volunteers to evaluate the performance. The proposed elastomer optical fiber sensor can achieve simultaneous measurement of RR and HR in different body positions, and also ballistocardiography (BCG) signal measurement in the lying position. The sensor has good accuracy and stability, with maximum errors of 1 bpm and 3 bpm for RR and HR, respectively, and average weighted mean absolute percentage error (MAPE) of 5.25% and root mean square error (RMSE) of 1.28 bpm. Moreover, the results of the Bland-Altman method showed good agreement of the sensor with manual counting of RR and with electrocardiogram (ECG) measurements of HR.(c) 2023 Optica Publishing Group under the terms of the Optica Open Access Publishing Agreement, National Key Research and Development Program of China (2022YFE0140400) ; National Natural Science Foundation of China (62003046, 62111530238) ; Basic and Applied Basic Research Foundation of Guangdong Province (2021A1515011997) ; Special project in key field of Guangdong Provincial Department of Education (2021ZDZX1050) ; The Innovation Team Project of Guangdong Provincial Department of Education (2021KCXTD014) .