Skip to main content

Resultados relacionados

Resultados totales (Incluyendo duplicados): 5
Encontrada(s) 1 página(s)

RiuNet. Repositorio Institucional de la Universitat Politécnica de Valéncia
Publication Artículo científico (JournalArticle)

Low-cost plastic optical fiber integrated with smartphone for human physiological monitoring

  • Kuang, Renfei
  • Ye, Yifan
  • Chen, Ziyan
  • He, Rungie
  • Savovic, Isadora
  • Djordjevic, Alexander
  • Savovic, Svetislav
  • Marques, Carlos
  • Li, Xiaoli
  • Min, Rui
  • Ortega Tamarit, Beatriz|||0000-0003-1196-4756
[EN] Human physiological signal monitoring is a key factor in diagnosing health conditions, such as monitoring heart rate and respiration. To meet the increasing monitoring requirements, such as safety, economy, and equipment miniaturization, it is necessary to optimize and improve the monitoring device. Polymer optical fiber sensor has great potential in human physiological monitoring because of their inherent safety, compactness, electrical isolation, and flexibility. In this paper, we report the integration of low-cost plastic optical fibers in smartphones for the measurement of respiratory rate and heart rate in human physiological monitoring. The performance of the plastic optical fiber (POF) sensor with different sensitivity zone is analyzed. With three sensitivity zones, the respiratory rate and heart rate can be displayed in the power spectral density simultaneously. For improving the POF sensor performance, the shutter speed of the smartphone is also optimized to 30 s(-1). Finally, the POF sensor is tested under different motion states indicate that the sensor can monitor the heart rate and breathing rate under different postures (running, walking, standing, squatting and lying), where the spectral energy is 2.8 +/- 0.11 x 10(8) pt during running and is 1.4 +/- 0.55 x 107 pt in the supine state. And it also can be used to assess the dynamic posture, which is important for some potential sensory applications in clinical and home settings., This research was funded by National Natural Science Foundation of China (62003046, 6211101138); Special Funds for the Cultivation of Guangdong College Students' Scientific and Technological Innovation ("Climbing Program" Special Funds) (pdjh2022a0684); Guangdong Provincial Department of Science and Technology (2021A1313030055); The Innovation Team Project of Guangdong Provincial Department of Education (2021KCXTD014); Special project in key field of Guangdong Provincial Department of Education (2021ZDZX1050); Guangdong Basic and Applied Basic Research Foundation (2021A1515011997).C. Marques acknowledges Fundac ~ao para a Ci <^>encia e a Tecnologia (FCT) through the CEECIND/00034/2018 (iFish project), PTDC/EEI-EEE/0415/2021 (DigiAqua) and this work was developed within the scope of the project i3N, UIDB/50025/2020 & UIDP/50025/2020, financed by national funds through the FCT/MEC.
RiuNet. Repositorio Institucional de la Universitat Politécnica de Valéncia
Publication Artículo científico (JournalArticle)

Chirped POF Bragg grating production utilizing UV cure adhesive coating for multiparameter sensing

  • Min, Rui
  • Pereira, Luis
  • Paixao, Tiago
  • Woyessa, Getinet
  • Hu, Xuehao
  • Antunes, Paulo
  • André, Paulo
  • Bang, Ole
  • Pinto, João
  • Marques, Carlos
  • Ortega Tamarit, Beatriz|||0000-0003-1196-4756
[EN] In this work, we obtained chirped Bragg gratings by post-coating uniform poly (methylmethacrylate) (PMMA) microstructured polymer optical fiber Bragg gratings (POFBGs) with an UV cure adhesive. The main advantage of the proposed method consists on being a cost-effective and simple solution, since no special phase mask, addi tional etching or gradient thermal annealing are required. A comparison between the fabricated chirped Bragg grating¿s performance and previous reported methods in the literature is presented. As a compact sensor with two different active areas (adhesive coated and uncoated sections of the POFBG), the developed sensing device can be used for multiparameter sensing, namely for strain, humidity and temperature monitoring. Allying the proposed flexible and low-cost fabrication technique with the intrinsic characteristics of POFs, one may conclude that the developed sensor has high potential for multiparameter sensing in possible future engineering and biomedical applications., National Natural Science Foundation of China (62003046) ; The Spanish Ministerio de Ciencia, Innovacion y Universidades RTI2018-101658-B-I00 FOCAL Project; Guangdong Basic and Applied Basic Research Foundation (2021A1515011997) ; Guangdong Recruitment Program of Foreign Experts (2020A1414010393) ; C. Marques ac-knowledges Fundacao para a Ciencia e a Tecnologia (FCT) through the CEECIND/00034/2018 (iFish project) and this work was developed within the scope of the project i3N, UIDB/50025/2020 &UIDP/50025/2020, financed by national funds through the FCT/MEC. Luis Pereira and Tiago Paixao also acknowledge FCT for the grant with references SFRH/BD/146295/2019 and PD/BD/128265/2016, respectively.
RiuNet. Repositorio Institucional de la Universitat Politécnica de Valéncia
Publication Artículo científico (JournalArticle)

Low-cost plastic optical fiber sensor embedded in mattress for sleep performance monitoring

  • Han, Pengfei
  • Li, Linqing
  • Zhang, Hao
  • Guan, Longzhou
  • Marques, Carlos
  • Savovic, Svetislav
  • Min, Rui
  • Li, Xiaoli
  • Ortega Tamarit, Beatriz|||0000-0003-1196-4756
[EN] In this study, we investigated plastic optical fiber (POF) pressure sensors embedded in mattresses to measure respiration and heart rate for sleep performance monitoring. The signal is amplified in the circuit using a two stage amplification scheme to collect weak respiration and heart rate signals while an algorithm was designed to obtain respiration and heart rate. We also propose a good reliability cutting-POF technology which can be used to improve pressure sensitivity. The experimental results indicate that the mattress can distinguish four behavioral states related to sleep (on bed, lying, moving and leaving bed) and can detect respiration and heart rate values in different positions and postures. Validation experiments on 10 participants showed that absolute error was less than one breath per minute and two beats per minute, making our approach suitable for household sleeping monitoring., National Natural Science Foundation of China (62003046) ; National Defense Basic Scientific Research Program of China (JCKY2018110B011) ; The Spanish Ministerio de Ciencia, Innovacion y Universidades RTI2018-101658-B-I00 FOCAL Project; Guangdong Recruitment Program of Foreign Experts (2020A1414010393) ; Guangdong Basic and Applied Basic Research Foundation (2021A1515011997) ; C. Marques acknowledges Fundacao para a Ciencia e a Tecnologia (FCT) through the CEECIND/00034/2018 (iFish project) and this work was developed within the scope of the project i3N, UIDB/50025/2020 &UIDP/50025/2020, financed by national funds through the FCT/MEC.
RiuNet. Repositorio Institucional de la Universitat Politécnica de Valéncia
Publication Artículo científico (JournalArticle)

Wearable photonic smart wristband for cardiorespiratory function assessment and biometric identification

  • Li, Wenbo
  • Long, Yukun
  • Yan, Yingyin
  • Xiao, Kun
  • Wang, Zhuo
  • Zheng, Di
  • Leal-Junior, Arnaldo
  • Kumar, Santosh
  • Marques, Carlos
  • Li, Xiaoli
  • Min, Rui
  • Ortega Tamarit, Beatriz|||0000-0003-1196-4756
[EN] Personalized health services are of paramount importance for the treatment and prevention of cardiorespiratory diseases, such as hypertension. The assessment of cardiorespiratory function and biometric identification (ID) is crucial for the effectiveness of such personalized health services. To effectively and accurately monitor pulse wave signals, thus achieving the assessment of cardiorespiratory function, a wearable photonic smart wristband based on an all-polymer sensing unit (All-PSU) is proposed. The smart wristband enables the assessment of cardiorespiratory function by continuously monitoring respiratory rate (RR), heart rate (HR), and blood pressure (BP). Furthermore, it can be utilized for biometric ID purposes. Through the analysis of pulse wave signals using power spectral density (PSD), accurate monitoring of RR and HR is achieved. Additionally, utilizing peak detection algorithms for feature extraction from pulse signals and subsequently employing a variety of machine learning methods, accurate BP monitoring and biometric ID have been realized. For biometric ID, the accuracy rate is 98.55%. Aiming to monitor RR, HR, BP, and ID, our solution demonstrates advantages in integration, functionality, and monitoring precision. These enhancements may contribute to the development of personalized health services aimed at the treatment and prevention of cardiorespiratory diseases., This research funded by the National Key R&D Program of China (2022YFE0140400) ; the National Natural Science Foundation of China (62405027, 62111530238, 62003046) ; Supporting project of major scientific research projects of Beijing Normal University at Zhuhai (ZHPT2023007) ; The work of R.Min was supported by the Tang Scholar of Beijing Normal University.The research was co-funded by the financial support of the European Union under the REFRESH-Research Excellence For REgion Sustainability and High-tech Industries project number CZ.10.03.01/00/22003/0000048 via the Operational Programme Just Transition. This work was developed within the scope of the projects CICECOAveiro Institute of Materials, UIDB/50011/2020 (DOI 10.54499/UIDB/50011/2020) , UIDP/50011/2020 (DOI 10.54499/UIDP/50011/2020) & LA/P/0006/2020 (DOI 10.54499/LA/P/0006/2020) financed by national funds through the FCT/MCTES (PIDDAC) .
RiuNet. Repositorio Institucional de la Universitat Politécnica de Valéncia
Publication Artículo científico (JournalArticle)

Wearable cardiorespiratory monitoring with stretchable elastomer optical fiber

  • Zha, B.
  • Wang, Z.
  • Li, L.
  • Hu, X.
  • Li, X.
  • Min, R.
  • Ortega Tamarit, Beatriz|||0000-0003-1196-4756
[EN] This work presents a stretchable elastomer optical fiber sensor incorporated into a belt for respiratory rate (RR) and heart rate (HR) monitoring. Different materials and shapes of prototypes designed were tested in terms of performance and the best choice was identified. The optimal sensor was tested by 10 volunteers to evaluate the performance. The proposed elastomer optical fiber sensor can achieve simultaneous measurement of RR and HR in different body positions, and also ballistocardiography (BCG) signal measurement in the lying position. The sensor has good accuracy and stability, with maximum errors of 1 bpm and 3 bpm for RR and HR, respectively, and average weighted mean absolute percentage error (MAPE) of 5.25% and root mean square error (RMSE) of 1.28 bpm. Moreover, the results of the Bland-Altman method showed good agreement of the sensor with manual counting of RR and with electrocardiogram (ECG) measurements of HR.(c) 2023 Optica Publishing Group under the terms of the Optica Open Access Publishing Agreement, National Key Research and Development Program of China (2022YFE0140400) ; National Natural Science Foundation of China (62003046, 62111530238) ; Basic and Applied Basic Research Foundation of Guangdong Province (2021A1515011997) ; Special project in key field of Guangdong Provincial Department of Education (2021ZDZX1050) ; The Innovation Team Project of Guangdong Provincial Department of Education (2021KCXTD014) .