Skip to main content

Resultados relacionados

Resultados totales (Incluyendo duplicados): 17
Encontrada(s) 1 página(s)

DIGITAL.CSIC. Repositorio Institucional del CSIC
Publication Artículo científico (JournalArticle)

Simple on-plastic/paper inkjet-printed solid-state Ag/AgCl pseudoreference electrode

  • Miserere, Sandrine
  • Merkoçi, Arben
A miniaturized, disposable, and low cost Ag/AgCl pseudoreference electrode based on inkjet printing has been developed. Silver ink was printed and chlorinated with bleach solution. The reference electrodes obtained in this work showed good reproducibility and stability during at least 30 min continuous measurement and even after 30 days storage without special care. Moreover, the strategy used in this work can be useful for large scale production of a solid-state Ag/AgCl pseudoreference electrode with different designs and sizes, facilitating the coupling with different electrical/electrochemical microsensors and biosensors., This work was supported by EU through FP7 “SMS” project (contract number 613844) and the National Council for Scientific and Technological Development, CNPq−Brazil., Peer Reviewed
DIGITAL.CSIC. Repositorio Institucional del CSIC
Publication Artículo científico (JournalArticle)

Annexin-V/quantum dot probes for multimodal apoptosis monitoring in living cells: improving bioanalysis using electrochemistry

  • Montón, Helena
  • Parolo, Claudio
  • Aranda-Ramos, Antonio
  • Merkoçi, Arben
  • Nogués, Carme
There is a great demand to develop novel techniques that allow useful and complete monitoring of apoptosis, which is a key factor of several diseases and a target for drug development. Here, we present the use of a novel dual electrochemical/optical label for the detection and study of apoptosis. We combined the specificity of Annexin-V for phosphatidylserine, a phospholipid expressed in the outer membrane of apoptotic cells, with the optical and electrochemical properties of quantum dots to create a more efficient label. Using this conjugate we addressed three important issues: (i) we made the labeling of apoptotic cells faster (30 min) and easier; (ii) we fully characterized the samples by common cell biological techniques (confocal laser scanning microscopy, scanning electron microscopy and flow cytometry); and (III) we developed a fast, cheap and quantitative electrochemical detection method for apoptotic cells with results in full agreement with those obtained by flow cytometry., The authors thank MICINN (project MAT2011-25870 and TEC2011-29140-C03-03), SMS (EU FP7 project) and the Generalitat de Catalunya (project 2014SGR-524) for supporting this project., Peer Reviewed
DIGITAL.CSIC. Repositorio Institucional del CSIC
Publication Artículo científico (JournalArticle)

In situ production of biofunctionalized few-layer defect-free microsheets of graphene

  • Gravagnuolo, Alfredo M.
  • Morales-Narváez, Eden
  • Silva, Everson T. da
  • Merkoçi, Arben
Biological interfacing of graphene has become crucial to improve its biocompatibility, dispersability, and selectivity. However, biofunctionalization of graphene without yielding defects in its sp2-carbon lattice is a major challenge. Here, a process is set out for biofunctionalized defect-free graphene synthesis through the liquid phase ultrasonic exfoliation of raw graphitic material assisted by the self-assembling fungal hydrophobin Vmh2. This protein (extracted from the edible fungus Pleurotus ostreatus) is endowed with peculiar physicochemical properties, exceptional stability, and versatility. The unique properties of Vmh2 and, above all, its superior hydrophobicity, and stability allow to obtain a highly concentrated (≈440–510 μg mL−1) and stable exfoliated material (ζ-potential, +40/+70 mV). In addition controlled centrifugation enables the selection of biofunctionalized few-layer defect-free micrographene flakes, as assessed by Raman spectroscopy, atomic force microscopy, scanning electron microscopy, and electrophoretic mobility. This biofunctionalized product represents a high value added material for the emerging applications of graphene in the biotechnological field such as sensing, nanomedicine, and bioelectronics technologies., This work was supported by The European Commission Program, FP7-OCEAN (613844) and MINECO (Spain; BIO2013–49464-EXP and RTC-2014–2619–7); Ministero dell’Università e della Ricerca Scientifica (Italy)—Industrial Research Project PON01_01966 EnerbioChem, funded in the frame of Operative National Programme Research and Competitiveness 2007–2013 D. D. Prot. n. 01/Ric. 18.1.2010; P.O.R. Campania FSE 2007–2013, Project CREMe. ICN2 acknowledges support from the Severo Ochoa Program (MINECO, Grant SEV-2013–0295)., Peer Reviewed
DIGITAL.CSIC. Repositorio Institucional del CSIC
Publication Artículo científico (JournalArticle)

Graphene-based Janus micromotors for the dynamic removal of pollutants

  • Orozco, Jahir
  • Mercante, Luiza A.
  • Pol, Roberto
  • Merkoçi, Arben
Persistent organic pollutants (POPs) are ubiquitous in the environment as a result of modern industrial processes. We present an effective POPs decontamination strategy based on their dynamic adsorption at the surface of reduced graphene oxide (rGO)-coated silica (SiO)-Pt Janus magnetic micromotors for their appropriate final disposition. While the motors rapidly move in a contaminated solution, the adsorption of POPs efficiently takes place in a very short time. Characterization of the micromotors both from the materials and from the motion point of view was performed. Polybrominated diphenyl ethers (PBDEs) and 5-chloro-2-(2,4-dichlorophenoxy) phenol (triclosan) were chosen as model POPs and the removal of the contaminants was efficiently achieved. The rGO-coated micromotors demonstrated superior adsorbent properties with respect to their concomitant GO-coated micromotors, static rGO-coated particles and dynamic silica micromotors counterparts. The extent of decontamination was studied over the number of micromotors, whose magnetic properties were used for their collection from environmental samples. The adsorption properties were maintained for 4 cycles of micromotors reuse. The new rGO-coated SiO functional material-based micromotors showed outstanding capabilities towards the removal of POPs and their further disposition, opening up new possibilities for efficient environmental remediation of these hazardous compounds., This study was supported by the European Commission Program, FP7-OCEAN, SMS Project (613844). ICN2 acknowledges support from the Severo Ochoa Program (MINECO, Grant SEV-2013-0295). The Nanobiosensors and Bioelectronics Group acknowledges the support from the Generalitat de Cataluña (Grant 2014 SGR 260). L. A. M. acknowledges the financial support from the FAPESP-BEPE (2014/26088-4) project., Peer Reviewed
DIGITAL.CSIC. Repositorio Institucional del CSIC
Publication Artículo científico (JournalArticle)

Molecularly imprinted polymer-decorated magnetite nanoparticles for selective sulfonamide detection

  • Zamora-Gálvez, Alejandro
  • Ait-Lahcen, Abdellatif
  • Mercante, Luiza A.
  • Morales-Narváez, Eden
  • Amine, Aziz
  • Merkoçi, Arben
Sulfonamides are known not only to be antimicrobial drugs that lead to antimicrobial resistance but also to be chemotherapeutic agents that may be allergenic and potentially carcinogenic, which represents a potentially hazardous compound once present in soil or water. Herein, a hybrid material based on molecularly imprinted polymer (MIP)-decorated magnetite nanoparticles for specific and label-free sulfonamide detection is reported. The composite has been characterized using different spectroscopic and imaging techniques. The magnetic properties of the composite are used to separate, preconcentrate, and manipulate the analyte which is selectively captured by the MIP onto the surface of the composite. Screen printed electrodes have been employed to monitor the impedance levels of the whole material, which is related to the amount of the captured analyte, via electrochemical impedance spectroscopy. This composite-based sensing system exhibits an extraordinary limit of detection of 1 × 10 mol L (2.8 × 10 ppb) (S/N = 3), which is close to those obtained with liquid chromatography and mass spectrometry, and it was demonstrated to screen sulfamethoxazole in a complex matrix such as seawater, where according to the literature sulfonamides content is minimum compared with other environmental samples., This work was supported by The European Commission Program, FP7-OCEAN, SMS Project (613844). ICN2 acknowledges support from the Severo Ochoa Program (MINECO, Grant SEV-2013-0295). Nanobiosensors and Bioelectronics Group acknowledges Supramolecular NanoChemistry and Materials group (Dr. Carlos Carbonell and Prof. Daniel Maspoch at ICN2) for BET measurements, and the support from Secretaria d’Universitats i Recerca del Departament d’Economia i Coneixement de la Generalitat de Catalunya (2014 SGR 260). L.A.M acknowledges financial support from FAPESP-BEPE (2014/26088-4) project., Peer Reviewed
DIGITAL.CSIC. Repositorio Institucional del CSIC
Publication Artículo científico (JournalArticle)

Nanochannels for electrical biosensing

  • Escosura-Muñiz, Alfredo de la
  • Merkoçi, Arben
This review shows the recent trends on the use of both single and array nanochannels for electrical biosensing applications. Some general considerations on the principles of the stochastic sensing, together with an overview about the common routes for nanochannels preparation before focusing on the applications for DNA, protein, virus, toxin and other analytes detection are given. Emerging materials used to obtain nanochannels, such as graphene and its analogues as well as novel systems based on the use of nanoparticles in combination with nanochannels are discussed. Aspects related to the analytical performance of the developed devices are also discussed. Finally prospects for future improvements and applications of this technology are included., We acknowledge the support of the Spanish MINECO under Project MAT2014-52485-P and through the Severo Ochoa Centers of Excellence Program under Grant SEV-2013-0295. The support from Secretaria d'Universitats i Recerca del Departament d'Economia i Coneixement de la Generalitat de Catalunya (Grant 2014 SGR 260) and from the E.C. under FP7-OCEAN 2013.1 contract number 613844 “SMS” are also acknowledged., Peer Reviewed
DIGITAL.CSIC. Repositorio Institucional del CSIC
Publication Artículo científico (JournalArticle)

Water activated graphene oxide transfer using wax printed membranes for fast patterning of a touch sensitive device

  • Baptista-Pires, Luis
  • Mayorga-Martínez, Carmen C.
  • Medina-Sánchez, Mariana
  • Montón, Helena
  • Merkoçi, Arben
We demonstrate a graphene oxide printing technology using wax printed membranes for the fast patterning and water activation transfer using pressure based mechanisms. The wax printed membranes have 50 μm resolution, longtime stability and infinite shaping capability. The use of these membranes complemented with the vacuum filtration of graphene oxide provides the control over the thickness. Our demonstration provides a solvent free methodology for printing graphene oxide devices in all shapes and all substrates using the roll-toroll automatized mechanism present in the wax printing machine. Graphene oxide was transferred over a wide variety of substrates as textile or PET in between others. Finally, we developed a touch switch sensing device integrated in a LED electronic circuit., This work was supported by The European Commission Program, FP7-OCEAN, SMS Project (613844). ICN2 acknowledges support from the Severo Ochoa Program (MINECO, Grant SEV-2013-0295). Nanobiosensors and Bioelectronics Group acknowledges Generalitat de Cataluña for SGR support and the authors would like to acknowledge MICINN for funding this project (grant MAT2014-52485-P; grant MAT2011-25870 for BES-2012-056022)., Peer Reviewed
DIGITAL.CSIC. Repositorio Institucional del CSIC
Publication Artículo científico (JournalArticle)

Graphene-encapsulated materials: Synthesis, applications and trends

  • Morales-Narváez, Eden
  • Sgobbi, Lívia Florio
  • Spinola Machado, Sergio Antonio
  • Merkoçi, Arben
Graphene-based materials (GBM) are an exceptional type of materials that offer unprecedented application capabilities to the scientific and technologic community. The encapsulation of different materials such as drugs, nanoparticles, polymers, oxides and cells by GBM is leading to outstanding hybrid materials with unprecedented behaviours promising a myriad of advantageous applications, including micro/nanomotors, biosensing platforms, bio/imaging agents, drug delivery systems, potential tumour treatment alternatives, environmental remediation platforms, advanced batteries and novel supercapacitors. We present an overview on graphene-encapsulated materials and their most important synthesis pathways. In addition, we explore the synergistic functionalities provided by these composites and highlight the state-of-the-art related to energy, environmental and bio-applications, among others. Finally, we discuss their challenges and future outlooks., This work was supported by: The European Commission Program, FP7-OCEAN, SMS Project (613844) and MINECO (Spain, MAT2014-52485-P, BIO2013-49464-EXP, RTC-2014-2619-7). ICN2 acknowledges support from the Severo Ochoa Program (MINECO, Grant SEV-2013-0295). Nanobiosensors and Bioelectronics Group acknowledges the support from Secretaria d’Universitats i Recerca del Departament d’Economia i Coneixement de la Generalitat de Catalunya (2014 SGR 260). The author SASM thanks FAPESP (Proc. No. 2013/17053-0) and CNPq (Proc. No. 302762/2013-2) for the financial support. The author LFS thanks FAPESP (Proc. No. 2012/08750-6 and 2013/20701-3)., Peer Reviewed
DIGITAL.CSIC. Repositorio Institucional del CSIC
Publication Artículo científico (JournalArticle)

Toward integrated detection and graphene-based removal of contaminants in a lab-on-a-chip platform

  • Chalupniak, Andrzej
  • Merkoçi, Arben
A novel, miniaturized microfluidic platform was developed for the simultaneous detection and removal of polybrominated diphenyl ethers (PBDEs). The platform consists of a polydimethylsiloxane (PDMS) microfluidic chip for an immunoreaction step, a PDMS chip with an integrated screen-printed electrode (SPCE) for detection, and a PDMS-reduced graphene oxide (rGO) chip for physical adsorption and subsequent removal of PBDE residues. The detection was based on competitive immunoassay-linked binding between PBDE and PBDE modified with horseradish peroxidase (HRP-PBDE) followed by the monitoring of enzymatic oxidation of o-aminophenol (o-AP) using square wave anodic stripping voltammetry (SW-ASV). PBDE was detected with good sensitivity and a limit of detection similar to that obtained with a commercial colorimetric test (0.018 ppb), but with the advantage of using lower reagent volumes and a reduced analysis time. The use of microfluidic chips also provides improved linearity and a better reproducibility in comparison to those obtained with batch-based measurements using screen-printed electrodes. In order to design a detection system suitable for toxic compounds such as PBDEs, a reduced graphene oxide–PDMS composite was developed and optimized to obtain increased adsorption (based on both the hydrophobicity and π–π stacking between rGO and PBDE molecules) compared to those of non-modified PDMS. To the best of our knowledge, this is the first demonstration of electrochemical detection of flame retardants and a novel application of the rGO-PDMS composite in a biosensing system. This system can be easily applied to detect any analyte using the appropriate immunoassay and it supports operation in complex matrices such as seawater., We acknowledge FP7 EU Project “SMS” (No. 613844). ICN2 acknowledges support from the Severo Ochoa Program (MINECO, No. SEV-2013-0295) and Secretaria d’Universitats i Recerca del Departament d′Economia i Coneixement de la Generalitat de Catalunya (2014 SGR 260)., Peer Reviewed
DIGITAL.CSIC. Repositorio Institucional del CSIC
Publication Artículo científico (JournalArticle)

Iridium oxide (IV) nanoparticle-based electrocatalytic detection of PBDE

  • Quesada-González, Daniel
  • Baiocco, Alessandra
  • Martos, Andrea A.
  • Escosura-Muñiz, Alfredo de la
  • Palleschi, Giuseppe
  • Merkoçi, Arben
Polybrominated diphenyl ethers (PBDEs) are a type of flame retardants which are currently banned in EU and USA due their hazardousness for humans and mammals. However, these compounds were highly used during more than 30 years and still persist in the environment since they are resistant to degradation. Herein we present a biosensor for the detection of PBDEs using screen printed carbon electrodes (SPCEs) based on the electrochemical monitoring of water oxidation reaction (WOR) catalyzed by iridium oxide (IV) nanoparticles (IrO2 NPs). Our assay shows a limit of detection of 21.5 ppb of PBDE in distilled water. We believe that such an IrO2 NPs-based electrocatalytic sensing system can lead to a rapid, sensitive, low cost and miniaturizable device for the detection of PBDEs., We acknowledge support from EU (FP7, SMS project) and MINECO (Spain) MAT2017-87202-P. This work is also funded by the CERCA Programme/Generalitat de Catalunya. ICN2 is supported by the Severo Ochoa program from Spanish MINECO (Grant no. SEV-2013-0295). Daniel Quesada-González also acknowledges Autonomous University of Barcelona (UAB) for the possibility of performing this work inside the framework of Chemistry PhD Programme., Peer reviewed
Dipòsit Digital de Documents de la UAB
Publication Artículo científico (JournalArticle)

Nanochannels for electrical biosensing

  • De La Escosura-Muñiz, Alfredo|||0000-0002-9600-0253
  • Merkoçi, Arben|||0000-0003-2486-8085
This review shows the recent trends on the use of both single and array nanochannels for electrical biosensing applications. Some general considerations on the principles of the stochastic sensing, together with an overview about the common routes for nanochannels preparation before focusing on the applications for DNA, protein, virus, toxin and other analytes detection are given. Emerging materials used to obtain nanochannels, such as graphene and its analogues as well as novel systems based on the use of nanoparticles in combination with nanochannels are discussed. Aspects related to the analytical performance of the developed devices are also discussed. Finally prospects for future improvements and applications of this technology are included.
Dipòsit Digital de Documents de la UAB
Publication Artículo científico (JournalArticle)

Graphene-based Janus micromotors for the dynamic removal of pollutants

  • Orozco, Jahir|||0000-0001-6249-8092
  • Mercante, Luiza A.
  • Pol, Roberto|||0000-0002-4387-4061
  • Merkoçi, Arben|||0000-0003-2486-8085
Persistent organic pollutants (POPs) are ubiquitous in the environment as a result of modern industrial processes. We present an effective POPs decontamination strategy based on their dynamic adsorption at the surface of reduced graphene oxide (rGO)-coated silica (SiO)-Pt Janus magnetic micromotors for their appropriate final disposition. While the motors rapidly move in a contaminated solution, the adsorption of POPs efficiently takes place in a very short time. Characterization of the micromotors both from the materials and from the motion point of view was performed. Polybrominated diphenyl ethers (PBDEs) and 5-chloro-2-(2,4-dichlorophenoxy) phenol (triclosan) were chosen as model POPs and the removal of the contaminants was efficiently achieved. The rGO-coated micromotors demonstrated superior adsorbent properties with respect to their concomitant GO-coated micromotors, static rGO-coated particles and dynamic silica micromotors counterparts. The extent of decontamination was studied over the number of micromotors, whose magnetic properties were used for their collection from environmental samples. The adsorption properties were maintained for 4 cycles of micromotors reuse. The new rGO-coated SiO functional material-based micromotors showed outstanding capabilities towards the removal of POPs and their further disposition, opening up new possibilities for efficient environmental remediation of these hazardous compounds.
Dipòsit Digital de Documents de la UAB
Publication Artículo científico (JournalArticle)

Annexin-V/quantum dot probes for multimodal apoptosis monitoring in living cells, Improving bioanalysis using electrochemistry

  • Montón i Domingo, Helena
  • Parolo, Claudio|||0000-0001-9481-4408
  • Aranda-Ramos, Antonio|||0000-0003-3476-7026
  • Merkoçi, Arben|||0000-0003-2486-8085
  • Nogués, Carme|||0000-0002-6361-8559
There is a great demand to develop novel techniques that allow useful and complete monitoring of apoptosis, which is a key factor of several diseases and a target for drug development. Here, we present the use of a novel dual electrochemical/optical label for the detection and study of apoptosis. We combined the specificity of Annexin-V for phosphatidylserine, a phospholipid expressed in the outer membrane of apoptotic cells, with the optical and electrochemical properties of quantum dots to create a more efficient label. Using this conjugate we addressed three important issues: (i) we made the labeling of apoptotic cells faster (30 min) and easier; (ii) we fully characterized the samples by common cell biological techniques (confocal laser scanning microscopy, scanning electron microscopy and flow cytometry); and (III) we developed a fast, cheap and quantitative electrochemical detection method for apoptotic cells with results in full agreement with those obtained by flow cytometry.
Dipòsit Digital de Documents de la UAB
Publication Artículo científico (JournalArticle)

Toward integrated detection and graphene-based removal of contaminants in a lab-on-a-chip platform

  • Chałupniak, Andrzej
  • Merkoçi, Arben|||0000-0003-2486-8085
A novel, miniaturized microfluidic platform was developed for the simultaneous detection and removal of polybrominated diphenyl ethers (PBDEs). The platform consists of a polydimethylsiloxane (PDMS) microfluidic chip for an immunoreaction step, a PDMS chip with an integrated screen-printed electrode (SPCE) for detection, and a PDMS-reduced graphene oxide (rGO) chip for physical adsorption and subsequent removal of PBDE residues. The detection was based on competitive immunoassay-linked binding between PBDE and PBDE modified with horseradish peroxidase (HRP-PBDE) followed by the monitoring of enzymatic oxidation of o-aminophenol (o-AP) using square wave anodic stripping voltammetry (SW-ASV). PBDE was detected with good sensitivity and a limit of detection similar to that obtained with a commercial colorimetric test (0.018 ppb), but with the advantage of using lower reagent volumes and a reduced analysis time. The use of microfluidic chips also provides improved linearity and a better reproducibility in comparison to those obtained with batch-based measurements using screen-printed electrodes. In order to design a detection system suitable for toxic compounds such as PBDEs, a reduced graphene oxide-PDMS composite was developed and optimized to obtain increased adsorption (based on both the hydrophobicity and π-π stacking between rGO and PBDE molecules) compared to those of non-modified PDMS. To the best of our knowledge, this is the first demonstration of electrochemical detection of flame retardants and a novel application of the rGO-PDMS composite in a biosensing system. This system can be easily applied to detect any analyte using the appropriate immunoassay and it supports operation in complex matrices such as seawater.
Dipòsit Digital de Documents de la UAB
Publication Artículo científico (JournalArticle)

Magnetic nanoparticle-molecular imprinted polymer, a new impedimetric sensor for tributyltin detection

  • Zamora Gálvez, Alejandro
  • Mayorga-Martinez, Carmen C.|||0000-0003-3687-0035
  • Parolo, Claudio|||0000-0001-9481-4408
  • Pons Picart, Josefina|||0000-0003-1834-9326
  • Merkoçi, Arben|||0000-0003-2486-8085
Recently, molecular imprinted polymers (MIPs) were extensively used for separation and identification of specific molecules, replacing expensive and unstable biological receptors. Nonetheless, their application in electrochemical sensors has not been sufficiently explored. Here we report the use of a MIP as a specific receptor in a new highly sensitive tributyltin (TBT) electrochemical sensor. The sensor combines the specificity, pre-concentration capability and robustness of molecular imprinted polymer attached onto magnetic nanoparticles with the quantitative outputs of impedimetric measurements. The proposed device detects TBT in a concentration range of 5 pM to 5 μM with a low limit of detection (5.37 pM), which is lower than the one recommended for TBT in sea water by the US Environmental Protection Agency (EPA). We believe that this new electrochemical sensor can play an important role in the monitoring of the quality of sea and fresh waters worldwide.
Dipòsit Digital de Documents de la UAB
Publication Artículo científico (JournalArticle)

Graphene Oxide-Poly(dimethylsiloxane)-Based Lab-on-a-Chip Platform for Heavy-Metals Preconcentration and Electrochemical Detection

  • Chałupniak, Andrzej
  • Merkoçi, Arben|||0000-0003-2486-8085
Herein, we present the application of a novel graphene oxide-poly(dimethylsiloxane) (GO-PDMS) composite in reversible adsorption/desorption, including detection of heavy metals. GO-PDMS was fabricated by simple blending of GO with silicon monomer in the presence of tetrahydrofuran, followed by polymerization initiated upon the addition of curing agent. We found GO concentration, curing agent concentration, pH, and contact time among the most important factors affecting the adsorption of Pb(II) used as a model heavy metal. The mechanism of adsorption is based on surface complexation, where oxygen active groups of negative charge can bind with bivalent metal ions Me(II). To demonstrate a practical application of this material, we fabricated microfluidic lab-on-a-chip platform for heavy-metals preconcentration and detection. This device consists of a screen-printed carbon electrode, a PDMS chip, and a GO-PDMS chip. The use of GO-PDMS preconcentration platform significantly improves the sensitivity of electrochemical detection of heavy metals (an increase of current up to 30× was observed), without the need of modifying electrodes or special reagents addition. Therefore, samples being so far below the limit of detection (0.5 ppb) were successfully detected. This approach is compatible also with real samples (seawater) as ionic strength was found as indifferent for the adsorption process. To the best of our knowledge, GO-PDMS was used for the first time in sensing application. Moreover, due to mechanical resistance and outstanding durability, it can be used multiple times unlike other GO-based platforms for heavy-metals adsorption.
Dipòsit Digital de Documents de la UAB
Publication Artículo científico (JournalArticle)

Molecularly imprinted polymer-decorated magnetite nanoparticles for selective sulfonamide detection

  • Zamora Gálvez, Alejandro
  • Ait-Lahcen, Abdellatif
  • Mercante, Luiza A.
  • Morales-Narváez, Eden|||0000-0002-1536-825X
  • Amine, Aziz
  • Merkoçi, Arben|||0000-0003-2486-8085
Sulfonamides are known not only to be antimicrobial drugs that lead to antimicrobial resistance but also to be chemotherapeutic agents that may be allergenic and potentially carcinogenic, which represents a potentially hazardous compound once present in soil or water. Herein, a hybrid material based on molecularly imprinted polymer (MIP)-decorated magnetite nanoparticles for specific and label-free sulfonamide detection is reported. The composite has been characterized using different spectroscopic and imaging techniques. The magnetic properties of the composite are used to separate, preconcentrate, and manipulate the analyte which is selectively captured by the MIP onto the surface of the composite. Screen printed electrodes have been employed to monitor the impedance levels of the whole material, which is related to the amount of the captured analyte, via electrochemical impedance spectroscopy. This composite-based sensing system exhibits an extraordinary limit of detection of 1 × 10 mol L (2.8 × 10 ppb) (S/N = 3), which is close to those obtained with liquid chromatography and mass spectrometry, and it was demonstrated to screen sulfamethoxazole in a complex matrix such as seawater, where according to the literature sulfonamides content is minimum compared with other environmental samples.